965 resultados para Direct measurement


Relevância:

60.00% 60.00%

Publicador:

Resumo:

Piezoelectric actuators are widely used in positioning systems which demand high resolution such as scanning microscopy, fast mirror scanners, vibration cancellation, cell manipulation, etc. In this work a piezoelectric flextensional actuator (PFA), designed with the topology optimization method, is experimentally characterized by the measurement of its nanometric displacements using a Michelson interferometer. Because this detection process is non-linear, adequate techniques must be applied to obtain a linear relationship between an output electrical signal and the induced optical phase shift. Ideally, the bias phase shift in the interferometer should remain constant, but in practice it suffers from fading. The J1-J4 spectral analysis method provides a linear and direct measurement of dynamic phase shift in a no-feedback and no-phase bias optical homodyne interferometer. PFA application such as micromanipulation in biotechnology demands fast and precise movements. So, in order to operate with arbitrary control signals the PFA must have frequency bandwidth of several kHz. However as the natural frequencies of the PFA are low, unwanted dynamics of the structure are often a problem, especially for scanning motion, but also if trajectories have to be followed with high velocities, because of the tracking error phenomenon. So the PFA must be designed in such a manner that the first mechanical resonance occurs far beyond this band. Thus it is important to know all the PFA resonance frequencies. In this work the linearity and frequency response of the PFA are evaluated up to 50 kHz using optical interferometry and the J1-J4 method.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

The formation of sulfated zirconia films from a sol-gel derived aqueous suspension is subjected to double-optical monitoring during batch dip coating. Interpretation of interferometric patterns, previously obscured by a variable refractive index, is now made possible by addition of its direct measurement by a polarimetric technique in real time. Significant sensitivity of the resulting physical thickness and refractive index curves (uncertainties of ±7 nm and ±0.005, respectively) to temporal film evolution is shown under different withdrawal speeds. As a first contribution to quantitative understanding of temporal film formation with varying nanostructure during dip coating, detailed analysis is directed to the stage of the process dominated by mass drainage, whose simple modeling with temporal t-1/2 dependence is verified experimentally. © 2006 Elsevier B.V. All rights reserved.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Given that the total amount of losses in a distribution system is known, with a reliable methodology for the technical loss calculation, the non-technical losses can be obtained by subtraction. A usual method of calculation technical losses in the electric utilities uses two important factors: load factor and the loss factor. The load factor is usually obtained with energy and demand measurements, whereas, to compute the loss factor it is necessary the learning of demand and energy loss, which are not, in general, prone of direct measurements. In this work, a statistical analysis of this relationship using the curves of a sampling of consumers in a specific company is presented. These curves will be summarized in different bands of coefficient k. Then, it will be possible determine where each group of consumer has its major concentration of points. ©2008 IEEE.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Foram realizadas medidas em laboratório da condutividade elétrica complexa de 28 amostras de testemunhos de sondagem de três furos da área MM1-Alvo 1, Distrito dos Carajás, com o objetivo de auxiliar na interpretação de dados geofísicos de campo, obtidos com os métodos polarização induzida/resistividade e eletromagnético/AFMAG, aplicados na área. As medidas foram tomadas no intervalo de frequências de 10-3Hz a 104Hz, medindo-se a amplitude e a fase da condutância. O método empregado foi o de medida direta de impedância, utilizando-se um osciloscópio com memória, um gerador de sinais e dois pré-amplificadores diferenciais com alta impedância de entrada. O sistema de eletrodos escolhido para realizar as medidas foi o de 2 eletrodos de platina-platinizada em virtude de sua resposta de frequência ser plana no intervalo utilizado. Todas as medidas foram realizadas à temperatura constante de 24°C ± 1°C. Para interpretar as medidas de condutividade foi realizado estudo petrográfico das amostras, utilizando-se lâminas delgadas, seções polidas e difração de Raios-X. Foi determinado o teor de cobre, sob a forma de sulfeto, nas amostras utilizando-se o método de absorção atômica. Os resultados petrográficos permitiram classificar as amostras em cinco grupos distintos: granito, biotita-xisto, anfibolito, anfibólio-xisto e quartzito ferruginoso-formação ferrífera. O teor de cobre foi variável nos cinco grupos, havendo teores desde 50ppm até 6000ppm. Nas medidas de condutividade observou-se que, dentre os cinco grupos, as amostras da formação ferrífera apresentaram as maiores variações com a frequência. As amostras de granito tiveram espectro mais plano que as dos xistos e anfibolito. A conclusão a que se chegou é que as anomalias eletromagnéticas e de polarização induzida/resistividade observadas no campo próximo aos três furos (F1, F2, F3) são devidas principalmgnte a formação ferrífera magnetitica, a secundariamente à mineralização de baixo teor de calcopirita associada.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

60.00% 60.00%

Publicador:

Resumo:

The purpose of this study was to determine a shape factor to estimate area of leaflets of two peanut cultivars (IAC TATU ST, IAC RUNNER 886). Correlation studies were conducted involving real leaf area (Sf) and leaf length (C), maximum leaf width (L) and the product between C and L. For each cultivar was determined a form factor (f) by means of regression analysis between the product of the length by the width and the actual area of leaves and the correlation between leaf area estimated by the correction factor and direct measurement. All evaluated models (linear, exponential or geometric) provided good estimates of leaf area (above 87%). Linear models had the best fit, passing or not through the origin. From a practical viewpoint, it is suggested to use the linear model involving the C and L product, using a linear coefficient equal to zero, with values of factor f equal to 0.7111 and 0.7266 for IAC RUNNER 886 and IAC TATU ST, respectively. The method of dimensions is feasible for the estimation of leaf area for both peanut cultivars, for showing good r(2) values (0.97), with errors below 3%, even when used with independent data.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Pós-graduação em Enfermagem (mestrado profissional) - FMB

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Piezoelectric transducers are widely used in high-resolution positioning systems. This paper reports the experimental analysis of a novel piezoelectric flextensional actuator (PFA), which is designed by using the topology-optimization method through a low-cost homodyne Michelson interferometer. By applying the J(1) - J(4) method for signal demodulation, which provides a linear and direct measurement of dynamic optical phase shift independent of fading, the nanometric displacements of the PFA were determined. Linearity and frequency response of the PFA were evaluated up to 50 kHz. PFA calibration factor and amplification rate were determined for the PFA operating in the quasi-static regime. To confirm the observed frequencies of resonance, an impedance analyzer is also utilized to measure the magnitude and phase of the PFA admittance.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

The practice of pharmaceutical care (PC) is recent in Brazil and little is known about its impact on the health system or patients. The aim of this review was thus to identify the clinical, humanistic and economic outcomes achieved by the practice of PC in Brazil. In order to assess those outcomes, data published in studies from 1997 to 2011 were collected from Lilacs and MEDLINE databases, using the technique of content analysis. Original studies on PC that included pharmacotherapeutic follow-up were considered eligible for this descriptive review. A total of 306 articles were identified through the chosen descriptors. Of those, ten studies were eligible for this review and only two did not report significant results. The others reported increased adherence to pharmacotherapy, resolution of pharmacotherapeutic issues and control of clinical parameters of diseases (such as maintenance or reduction of blood pressure, reduction in HIV viral load and increase in lymphocyte count), promoting improvements in the general state of health and behavioral changes. However, economic impact was not assessed in any article analyzed, nor was a direct measurement of life quality performed. Although there are few studies on the outcomes of pharmaceutical care services in Brazil, it is demonstrated in this review that positive results were obtained when the pharmacist acted as a provider of optimized pharmacotherapy. This may be considered a result of the actions that followed the Brazilian Pharmaceutical Care Consensus of 2002, such as the restructuring of the curricular basis of pharmacy courses. From this point on, Brazilian researchers and pharmacists should think of a strategy to expand the offer of pharmaceutical care beyond academia and reach people in general who need this type of health care.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)

Relevância:

60.00% 60.00%

Publicador:

Resumo:

We present a direct measurement of the low-energy Li-8(p, alpha)He-5 cross section, using a radioactive Li-8 beam impinging on a thick target. With four beam energies, we cover the energy range between E-c.m. = 0.2 and 2.1 MeV. An R-matrix analysis of the data is performed and suggests the existence of two broad overlapping resonances (5/2(+) at E-c.m. = 1.69 MeV and 7/2(+) at E-c.m. = 1.76 MeV). At low energies our data are sensitive to the properties of a subthreshold state (E-x = 16.67 MeV) and of two resonances above threshold. These resonances were observed in previous experiments. The R-matrix fit confirms spin assignments, and provides partial widths. We propose a new Li-8(p, alpha)He-5 reaction rate and briefly discuss its influence in nuclear astrophysics. DOI: 10.1103/PhysRevC.86.064321