944 resultados para Diode array UV spectroscopy


Relevância:

100.00% 100.00%

Publicador:

Resumo:

Carbon dioxide (CO2) has been of recent interest due to the issue of greenhouse cooling in the upper atmosphere by species such as CO2 and NO. In the Earth’s upper atmosphere, between altitudes of 75 and 110 km, a collisional energy exchange occurs between CO2 and atomic oxygen, which promotes a population of ground state CO2 to the bend excited state. The relaxation of CO2 following this excitation is characterized by spontaneous emission of 15-μm. Most of this energy is emitted away from Earth. Due to the low density in the upper atmosphere, most of this energy is not reabsorbed and thus escapes into space, leading to a local cooling effect in the upper atmosphere. To determine the efficiency of the CO2- O atom collisional energy exchange, transient diode laser absorption spectroscopy was used to monitor the population of the first vibrationally excited state, 13CO2(0110) or ν2, as a function of time. The rate coefficient, kO(ν2), for the vibrational relaxation 13CO2 (ν2)-O was determined by fitting laboratory measurements using a home-written linear least squares algorithm. The rate coefficient, kO(ν2), of the vibrational relaxation of 13CO2(ν2), by atomic oxygen at room temperature was determined to be (1.6 ± 0.3 x 10-12 cm3 s-1), which is within the uncertainty of the rate coefficient previously found in this group for 12CO2(ν2) relaxation. The cold temperature kO(ν2) values were determined to be: (2.1 ± 0.8) x 10-12 cm3 s-1 at Tfinal = 274 K, (1.8 ± 0.3) x 10-12 cm3 s-1 at Tfinal = 239 K, (2 ± 1) x 10-12 cm3 s-1 at Tfinal = 208 K, and (1.7 ± 0.3) x 10-12 cm3 s-1 at Tfinal = 186 K. These data did not show a definitive negative temperature dependence comparable to that found for 12CO2 previously.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Transient Diode Laser Absorption Spectroscopy (TDLAS) was used to perform vibrational state population studies of the CO2 product from the hyperthermal reaction between C2H4 and O(3P) at room temperature using O3 as the O-atom precursor. Photodissociation of O3 using a frequency quadrupled Q-switch Nd:YAG laser pulse at 266 nm produced O(3P) atoms at high velocities which subsequently reacted with C2H4, producing several primary and secondary products including CO2. The CO2 product was detected using high-resolution TDLAS under five unique sets of reaction conditions. The vibrational distribution of the CO2 product did not follow a Boltzmann distribution at all five sets of conditions. The experiments showed a distribution in which there was a surprisingly high population in the (1000) (symmetric stretching) state compared with the other states probed, all of which contained bend excitation. In general, the CO2 population in the (1000) state was about 15-20% more populated than the Boltzmann distribution predicts. A possible explanation for this result may lie in the mechanism of CO2 evolution from the C2H4 + O(3P) reaction.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Laboratory measurements of the rate coefficient for quenching of O3(nu2) by ground-state atomic oxygen, kO(nu2), at room temperature are presented. kO(nu2) is currently not well known and is necessary for appropriate nonlocal thermodynamic equilibrium modeling of the upper mesosphere and lower thermosphere. In this work, a 266 nm laser pulse photolyzes a small amount of O3 in a slow-flowing gas mixture of O3, Xe, and Ar. This process simultaneously produces atomic oxygen and increases the temperature of the gas mixture slightly, thereby increasing the population in the O3(nu2) state. Transient diode laser absorption spectroscopy is used to monitor the populations of the O3(nu2) and ground vibrational states as the system re-equilibrates. Relaxation rates are measured over a range of quencher concentrations to extract the rate coefficient of interest. The value of kO(nu2) was determined to be (2.2 0.5) * 10(-12) cm(3) s(-1).

Relevância:

100.00% 100.00%

Publicador:

Resumo:

An HPLC-DAD method for the quantitative analysis of Δ(9)-tetrahydrocannabinol (THC), Δ(9)-tetrahydrocannabinolic acid-A (THCA-A), cannabidiol (CBD), and cannabinol (CBN) in confiscated cannabis products has been developed, fully validated and applied to analyse seized cannabis products. For determination of the THC content of plant material, this method combines quantitation of THCA-A, which is the inactive precursor of THC, and free THC. Plant material was dried, homogenized and extracted with methanol by ultrasonication. Chromatographic separation was achieved with a Waters Alliance 2695 HPLC equipped with a Merck LiChrospher 60 RP-Select B (5μm) precolumn and a Merck LiChroCart 125-4 LiChrospher 60 RP-Select B (5μm) analytical column. Analytes were detected and quantified using a Waters 2996 photo diode array detector. This method has been accepted by the public authorities of Switzerland (Bundesamt für Gesundheit, Federal Office of Public Health), and has been used to analyse 9092 samples since 2000. Since no thermal decarboxylation of THCA-A occurs, the method is highly reproducible for different cannabis materials. Two calibration ranges are used, a lower one for THC, CBN and CBD, and a higher one for THCA-A, due to its dominant presence in fresh plant material. As provider of the Swiss proficiency test, the robustness of this method has been tested over several years, and homogeneity tests even in the low calibration range (1%) show high precision (RSD≤4.3%, except CBD) and accuracy (bias≤4.1%, except CBN).

Relevância:

100.00% 100.00%

Publicador:

Resumo:

To ensure the integrity of an intensity modulated radiation therapy (IMRT) treatment, each plan must be validated through a measurement-based quality assurance (QA) procedure, known as patient specific IMRT QA. Many methods of measurement and analysis have evolved for this QA. There is not a standard among clinical institutions, and many devices and action levels are used. Since the acceptance criteria determines if the dosimetric tools’ output passes the patient plan, it is important to see how these parameters influence the performance of the QA device. While analyzing the results of IMRT QA, it is important to understand the variability in the measurements. Due to the different form factors of the many QA methods, this reproducibility can be device dependent. These questions of patient-specific IMRT QA reproducibility and performance were investigated across five dosimeter systems: a helical diode array, radiographic film, ion chamber, diode array (AP field-by-field, AP composite, and rotational composite), and an in-house designed multiple ion chamber phantom. The reproducibility was gauged for each device by comparing the coefficients of variation (CV) across six patient plans. The performance of each device was determined by comparing each one’s ability to accurately label a plan as acceptable or unacceptable compared to a gold standard. All methods demonstrated a CV of less than 4%. Film proved to have the highest variability in QA measurement, likely due to the high level of user involvement in the readout and analysis. This is further shown by how the setup contributed more variation than the readout and analysis for all of the methods, except film. When evaluated for ability to correctly label acceptable and unacceptable plans, two distinct performance groups emerged with the helical diode array, AP composite diode array, film, and ion chamber in the better group; and the rotational composite and AP field-by-field diode array in the poorer group. Additionally, optimal threshold cutoffs were determined for each of the dosimetry systems. These findings, combined with practical considerations for factors such as labor and cost, can aid a clinic in its choice of an effective and safe patient-specific IMRT QA implementation.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Introdução: Diante das mudanças nos hábitos de consumo alimentar da população brasileira, suplementos vitamínicos e alimentos enriquecidos são veículos comumente empregados para atender as necessidades de ingestão de micronutrientes. A diversidade de suplementos vitamínicos comercializados atualmente leva à necessidade de desenvolvimento de métodos analíticos de fácil execução e alta produtividade. Informações confiáveis sobre os teores de vitaminas poderão ser obtidas somente com métodos analíticos validados. Objetivos: Validar metodologias analíticas e avaliar o teor de vitaminas antioxidantes em suplementos adquiridos no comércio do município de São Paulo - Brasil, o efeito do armazenamento nestes compostos e confrontar os valores analisados com os valores declarados na rotulagem. Métodos: As metodologias analíticas para determinação de vitaminas antioxidantes por cromatografia líquida de alta eficiência com detector de arranjo de diodos (CLAE-DAD) e de vitamina C por titulação potenciométrica foram validadas para as matrizes sólidas, oleosas e líquidas de suplementos vitamínicos. A estabilidade das vitaminas foi avaliada a cada 6 meses durante 12 meses de armazenamento e a avaliação da rotulagem foi realizada de acordo com as legislações vigentes no Brasil. Resultados: Para os métodos cromatográficos, os limites de detecção (LDs) e de quantificação (LQs) variaram entre 0,3 e 4,3 µg/mL, e entre 0,5 e 14,0 µg/mL respectivamente. As recuperações dos padrões adicionados nas matrizes variaram entre 92 por cento e 109 por cento e entre 86 por cento e 108 por cento no material de referência. A repetitividade foi calculada pelo desvio padrão relativo (RSD), apresentando valores entre 0,2 por cento e 9,6 por cento . Para a determinação de vitamina C pelo método potenciométrico, o LD e o LQ foram respectivamente 1 mg e 3 mg; a recuperação no material de referência foi de 99,8 por cento e a precisão variou entre 0,4 e 3,9 por cento . Das 57 amostras avaliadas, 59 por cento e 35 por cento apresentaram teores de vitaminas A e E respectivamente, abaixo dos valores declarados no rótulo; por outro lado, 20 por cento das amostras apresentaram teores de vitamina E acima dos valores declarados. Em relação aos teores de vitamina C, 60 por cento das amostras estavam de acordo com os valores declarados. O estudo da estabilidade demonstrou degradação significativa das vitaminas A, E e C em aproximadamente 90 por cento das amostras com 12 meses de armazenamento. Na avaliação da rotulagem dos suplementos vitamínicos, 47 das amostras apresentaram uma ou mais irregularidades. Conclusão: Os métodos propostos se mostraram adequados para análise de diferentes matrizes de suplementos vitamínicos. Os resultados das análises de vitaminas nestes produtos mostraram a necessidade urgente de monitoramento em conjunto com ações de fiscalização, pois verificou-se que a maioria das amostras não atenderam a legislação, principalmente quanto aos teores declarados na informação nutricional da rotulagem. A sobredosagem de vitaminas pode ser necessária para manter os teores declarados durante o armazenamento, porém, a quantidade adicional de vitamina a ser incluída no suplemento deve estar dentro de limites seguros e depende de cada amostra, pois além da matriz, diversos fatores relacionados aos compostos e à embalagem também podem influenciar na estabilidade das vitaminas.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Tetrazolo[1,5-a] quinazoline (9) is converted to 2-azidoquinazoline (10) on sublimation at 200 degrees C and above, and the azide-tetrazole equilibrium is governed by entropy. 2-Quinazolylnitrenes 11 and 27 and/ or their ring expansion products 14 and 29 can undergo type I (ylidic) and type II (diradicaloid) ring opening. Argon matrix photolysis of 9/10 affords 2-quinazolylnitrene (11), which has been characterized by ESR, UV, and IR spectroscopy. A minor amount of a second nitrene, formed by rearrangement or ring opening, is also observed. A diradical (19) is formed rapidly by type II ring opening and characterized by ESR spectroscopy; it decays thermally at 15 K with a half-life of ca. 47 min, in agreement with its calculated facile intersystem crossing (19T -> 19OSS) followed by facile cyclization/rearrangement to 1-cyanoindazole (21) (calculated activation barrier 1- 2 kcal/mol) and N-cyanoanthranilonitrile (22). 21 and 22 are the isolated end products of photolysis. 21 is also the end product of flash vacuum thermolysis. An excellent linear correlation between the zero-field splitting parameter D (cm(-1)) and the spin density F on the nitrene N calculated at the B3LYP/EPRIII level is reported (R-2 = 0.993 for over 100 nitrenes). Matrix photolysis of 3-phenyltetrazolo[1,5-a] quinazoline (25) affords the benzotriazacycloheptatetraene 29, which can be photochemically interconverted with the type I ring opening product 2-isocyano-alpha-diazo-alpha- phenyltoluene (33) as determined by IR and UV spectroscopy. The corresponding carbene 37, obtained by photolysis of 33, was detected by matrix ESR spectroscopy.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Alpha-fetoprotein (AFP) is a commercially important polypeptide with important diagnostic. physiological and immunomodulatory functions. Previous studies into the refolding of this macromolecule are contradictory. and variously suggest that AFP denaturation may be irreversible or that refolding may be achieved by reducing denaturant concentration through dilution but not dialysis. Importantly, these same previous studies do not provide quantitative metrics by which the Success of refolding, and the potential for bioprocess development. can be assessed. Moreover, these same studies do not optimize and control refolding redox potential - an important factor considering that AFP contains 32 cysteines which form 16 disulfide bonds. In this current study, a quantitative comparison of recombinant human AFP (rhAFP) refolding by dilution and dialysis is conducted under optimized redox conditions. rhAFP refolding yields were > 35% (dialysis refolding) and > 75% (dilution refolding) as assessed by RP-HPLC and ELISA, with structural Similarity to the native state confirmed by UV spectroscopy. Dialysis refolding yield was believed to be lower because the gradual reduction in denaturant concentration allowed extended conformational searching. enabling more time for undesirable interaction with other protein molecules and/or the dialysis membrane, leading to a Sub-optimal process outcome. Significant yield sensitivity to redox environment was also observed, emphasizing the importance of physicochemical optimization. This study demonstrates that very high refolding yields can be obtained, for a physiologically relevant protein, with optimized dilution refolding. The study also highlights the quantitative metrics and macromolecular physical spectroscopic 'fingerprints' required to facilitate transition from laboratory to process scale.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Purpose: The use of PHMB as a disinfectant in contact lens multipurpose solutions has been at the centre of much debate in recent times, particularly in relation to the issue of solution induced corneal staining. Clinical studies have been carried out which suggest different effects with individual contact lens materials used in combination with specific PHMB containing care regimes. There does not appear to be, however, a reliable analytical technique that would detect and quantify with any degree of accuracy the specific levels of PHMB that are taken up and released from individual solutions by the various contact lens materials. Methods: PHMB is a mixture of positively charged polymer units of varying molecular weight that has maximum absorbance wavelength of 236 nm. On the basis of these properties a range of assays including capillary electrophoresis, HPLC, a nickelnioxime colorimetric technique, mass spectrophotometry, UV spectroscopy and ion chromatography were assessed paying particular attention to each of their constraints and detection levels. Particular interest was focused on the relative advantage of contactless conductivity compared to UV and mass spectrometry detection in capillary electrophoresis (CE). This study provides an overview of the comparative performance of these techniques. Results: The UV absorbance of PHMB solutions, ranging from 0.0625 to 50 ppm was measured at 236 nm. Within this range the calibration curve appears to be linear however, absorption values below 1 ppm (0.0001%) were extremely difficult to reproduce. The concentration of PHMB in solutions is in the range of 0.0002–0.00005% and our investigations suggest that levels of PHMB below 0.0001% (levels encountered in uptake and release studies) can not be accurately estimated, in particular when analysing complex lens care solutions which can contain competitively absorbing, and thus interfering, species in the solution. The use of separative methodologies, such as CE using UV detection alone is similarly limited. Alternative techniques including contactless conductivity detection offer greater discrimination in complex solutions together with the opportunity for dual channel detection. Preliminary results achieved by TraceDec1 contactless conductivity detection, (Gain 150%, Offset 150) in conjunction with the Agilent capillary electrophoresis system using a bare fused silica capillary (extended light path, 50 mid, total length 64.5 cm, effective length 56 cm) and a cationic buffer at pH 3.2, exhibit great potential with reproducible PHMB split peaks. Conclusions: PHMB-based solutions are commonly associated with the potential to invoke corneal staining in combination with certain contact lens materials. However this terminology ‘PHMBbased solution’ is used primarily because PHMB itself has yet to be adequately implicated as the causative agent of the staining and compromised corneal cell integrity. The lack of well characterised adequately sensitive assays, coupled with the range of additional components that characterise individual care solutions pose a major barrier to the investigation of PHMB interactions in the lenswearing eye.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The lipophilic dihydrofolate reductase (DHFR) inhibitor m-azidopyrimethamine (MZP) was investigated for suitability for development as a topical antipsoriatic agent. The clinical features and treatments for psoriasis were reviewed. High performance liquid chromatography (HPLC) was employed as the main analytical method, with UV spectroscopy being used in some cases. Reduction of the azido-group was proposed as a potential detoxification mechanism for MZP. The rates of reduction of a series of substituted phenyl azide compounds by dithiothreitol were investigated and found to depend on the substitution pattern of the aryl azide molecular, with electron deficient azides exhibiting faster rates of reduction in the system studied. The rates of reduction of MZP and analogous compounds were also studied using this model. The skin penetration of MZP was assessed using an in vitro hairless mouse skin model. The rate of permeation (flux) of MZP across hairless mouse skin was found to be dependent on the quantity of propylene glycol used as cosolvent in the vehicle and the pH. The use of a pretreatment regime of oleic acid in propylene glycol was shown to greatly increase the penetration of MZP through the hairless mouse skin as compared to application without pretreatment, or pretreatment with other penetration enhancers. The metabolism of MZP was studied in in vitro models comprising skin homogenates, SV-K14 human keratinocyte cell cultures and skin commensal bacterial cultures. No conversion of MZP to the corresponding amine was detected in any of the models. The growth inhibitory properties of MZP were investigated in an in vitro SV-K14 human keratinocyte cell culture model and compared with those of other DHFR inhibitors. [14C]-pyrimethamine was shown to be taken up by the SV-K14 keratinocytes.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

A refractive index sensing system has been demonstrated, which is based upon an in-line fibre long period grating Mach-Zehnder interferometer with a heterodyne interrogation technique. This sensing system has comparable accuracy to laboratory-based techniques used in industry such as high performance liquid chromatography and UV spectroscopy. The advantage of this system is that measurements can be made in-situ for applications in continuous process control. Compared to other refractive index sensing schemes using LPGs, this approach has two main advantages. Firstly, the system relies on a simple optical interrogation system and therefore has the real potential for being low cost, and secondly, so far as we are aware it provides the highest refractive index resolution reported for any fibre LPG device.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

A long-period grating (LPG) sensor is used to detect small variations in the concentration of an organic aromatic compound (xylene) in a paraffin (heptane) solution. A new design procedure is adopted and demonstrated to maximize the sensitivity of LPG (wavelength shift for a change in the surrounding refractive index, (dλ/dn3)) for a given application. The detection method adopted is comparable to the standard technique used in industry (high performance liquid chromatograph and UV spectroscopy) which has a relative accuracy between ∼±0.5% and 5%. The minimum detectable change in volumetric concentration is 0.04% in a binary fluid with the detection system presented. This change of concentration relates to a change in refractive index of Δn ∼ 6 × 10-5. © 2001 Elsevier Science B.V.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Hancornia speciosa Gomes (Apocynaceae), popularly known as ‘mangabeira’, has been used in folk medicine to treat inflammatory disorders, hypertension, dermatitis, diabetes, liver diseases and stomach disorders. Regarding the Hancornia speciosa fruits, the ethnobotany indicates its use especially for treating inflammation and tuberculosis. However, no study has been done so far to prove such biological activities. The objective was evaluation anti-inflammatory activity from the fruits of Hancornia speciosa Gomes (mangabeira). Aqueous extract was prepared by decoction, subsequently submitted the liquid-liquid fractionation. The secondary metabolites were identified by high performance liquid chromatography coupled with detector diode array (HPLC-DAD) and liquid chromatography diode array detector coupled with mass spectrometry (LC-DAD-MS). The anti-inflammatory properties of the aqueous extract, dichloromethane (CH2Cl2), ethyl acetate (EtOAc) and n-butanol (n-BuOH) fractions of the fruits from H. speciosa, as well as rutin and chlorogenic acid were investigated using in vitro and in vivo models. In vivo tests comprised the xylene-induced ear edema that was measured the formation of edema, carrageenan-induced peritonitis was evaluated the total leukocytes at 4h and zymosan-induced air pouch was measured the total leukocytes and differential cell count at 6, 24 and 48 hours, whereas in vitro tests were evaluated levels of cytokines IL-1β, IL-6, IL-12 and TNF-α using ELISA obtained of carrageenan-induced peritonitis model. The results showed the presence of rutin and chlorogenic acid were detected in the aqueous extract from H. speciosa fruits by HPLC-DAD and LC-DAD-ME. Furthermore, the aqueous extracts and fractions, as well as rutin and chlorogenic acid significantly inhibited the xilol-induced ear edema and reduced cell migration in the animal models such as carrageenan-induced peritonitis and zymosan-induced air pouch. In addition, reduced levels of cytokines IL-1β, IL-6, IL-12 and TNF-α were observed. This is the first study that demonstrated the anti-inflammatory effect of aqueous extract from Hancornia speciosa fruits against different inflammatory agents in animal models, suggesting that their bioactive molecules, especially rutin and chlorogenic acid contributing, at least in part, to the anti-inflammatory effect of aqueous extract. These findings support the widespread use of Hancornia speciosa in popular medicine and demonstrate that this aqueous extract has therapeutic potential for the development of a herbal drugs with anti-inflammatory properties.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

We quantified pigment biomarkers by high performance liquid chromatography (HPLC) to obtain a broad taxonomic classification of microphytobenthos (MPB) (i.e. identification of dominant taxa). Three replicate sediment cores were collected at 0, 50 and 100 m along transects 5-9 in Heron Reef lagoon (n=15) (Fig. 1). Transects 1-4 could not be processed because the means to have the samples analysed by HPLC were not available at the time of field data collection. Cores were stored frozen and scrapes taken from the top of each one and placed in cryovials immersed in dry ice. Samples were sent to the laboratory (CSIRO Marine and Atmospheric Research, Hobart, Australia) where pigments were extracted with 100% acetone during fifteen hours at 4°C after vortex mixing (30 seconds) and sonication (15 minutes). Samples were then centrifuged and filtered prior to the analysis of pigment composition with a Waters - Alliance HPLC system equipped with a photo-diode array detector. Pigments were separated using a Zorbax Eclipse XDB-C8 stainless steel 150 mm x 4.6 mm ID column with 3.5 µm particle size (Agilent Technologies) and a binary gradient system with an elevated column temperature following a modified version of the Van Heukelem and Thomas (2001) method. The separated pigments were detected at 436 nm and identified against standard spectra using Waters Empower software. Standards for HPLC system calibration were obtained from Sigma (USA) and DHI (Denmark).

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Background/Aim: Formaldehyde is classified as carcinogenic to humans, making it a major concern, particularly in occupational settings. Fat-soluble vitamins, such as vitamins A, D, and E, are documented as antigenotoxic and antimutagenic and also correlate with the cell antioxidant potential. This study investigates the influence of these vitamins on genotoxicity biomarkers of formaldehyde-exposed hospital workers. Methods: The target population were hospital workers exposed to formaldehyde (n = 55). Controls were nonexposed individuals (n = 80). The most used genotoxicity biomarkers were the cytokinesis-block micronucleus assay for lymphocytes and the micronucleus test for exfoliated buccal cells. Vitamins A and E were determined by high-performance liquid chromatography with a diode array detector (HPLC-DAD) and vitamin D receptor (VDR) polymorphisms by real-time PCR. Results: Significant correlations were found between genotoxicity biomarkers and between vitamins A and E in controls. Multiple regression showed that vitamin A was significantly associated with a higher mean of nucleoplasmic bridges (p < 0.001), and vitamin E was significantly associated with a decreased frequency of nuclear buds (p = 0.045) in the exposed group. No effect of vitamin D was observed. The VDRBsmI TT genotype carriers presented higher means of all the genotoxicity biomarkers; however, we found no significant associations. Conclusions: The study suggests that vitamin levels may modulate direct signs of genotoxicity.