941 resultados para Digital mammographic images


Relevância:

30.00% 30.00%

Publicador:

Resumo:

Simultaneous neural recordings taken from multiple areas of the rodent brain are garnering growing interest due to the insight they can provide about spatially distributed neural circuitry. The promise of such recordings has inspired great progress in methods for surgically implanting large numbers of metal electrodes into intact rodent brains. However, methods for localizing the precise location of these electrodes have remained severely lacking. Traditional histological techniques that require slicing and staining of physical brain tissue are cumbersome, and become increasingly impractical as the number of implanted electrodes increases. Here we solve these problems by describing a method that registers 3-D computerized tomography (CT) images of intact rat brains implanted with metal electrode bundles to a Magnetic Resonance Imaging Histology (MRH) Atlas. Our method allows accurate visualization of each electrode bundle's trajectory and location without removing the electrodes from the brain or surgically implanting external markers. In addition, unlike physical brain slices, once the 3D images of the electrode bundles and the MRH atlas are registered, it is possible to verify electrode placements from many angles by "re-slicing" the images along different planes of view. Further, our method can be fully automated and easily scaled to applications with large numbers of specimens. Our digital imaging approach to efficiently localizing metal electrodes offers a substantial addition to currently available methods, which, in turn, may help accelerate the rate at which insights are gleaned from rodent network neuroscience.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

During the 1970’s and 1980’s, the late Dr Norman Holme undertook extensive towed sledge surveys in the English Channel and some in the Irish Sea. Only a minority of the resulting images were analysed and reported before his death in 1989 but logbooks, video and film material has been archived in the National Marine Biological Library (NMBL) in Plymouth. A scoping study was therefore commissioned by the Joint Nature Conservation Committee and as a part of the Mapping European Seabed Habitats (MESH) project to identify the value of the material archived and the procedure and cost to undertake further work. The results of the scoping study are: 1. NMBL archives hold 106 videotapes (reel-to-reel Sony HD format) and 59 video cassettes (including 15 from the Irish Sea) in VHS format together with 90 rolls of 35 mm colour transparency film (various lengths up to about 240 frames per film). These are stored in the Archive Room, either in a storage cabinet or in original film canisters. 2. Reel-to-reel material is extensive and had already been selectively copied to VHS cassettes. The cost of transferring it to an accepted ‘long-life’ medium (Betamax) would be approximately £15,000. It was not possible to view the tapes as a suitable machine was not located. The value of the tapes is uncertain but they are likely to become beyond salvation within one to two years. 3. Video cassette material is in good condition and is expected to remain so for several more years at least. Images viewed were generally of poor quality and the speed of tow often makes pictures blurred. No immediate action is required. 4. Colour transparency films are in good condition and the images are very clear. They provide the best source of information for mapping seabed biotopes. They should be scanned to digital format but inexpensive fast copying is problematic as there are no between-frame breaks between images and machines need to centre the image based on between-frame breaks. The minimum cost to scan all of the images commercially is approximately £6,000 and could be as much as £40,000 on some quotations. There is a further cost in coding and databasing each image and, all-in-all it would seem most economic to purchase a ‘continuous film’ scanner and undertake the work in-house. 5. Positional information in ships logs has been matched to films and to video tapes. Decca Chain co-ordinates recorded in the logbooks have been converted to latitude and longitude (degrees, minutes and seconds) and a further routine developed to convert to degrees and decimal degrees required for GIS mapping. However, it is unclear whether corrections to Decca positions were applied at the time the position was noted. Tow tracks have been mapped onto an electronic copy of a Hydrographic Office chart. 6. The positions of start and end of each tow were entered to a spread sheet so that they can be displayed on GIS or on a Hydrographic Office Chart backdrop. The cost of the Hydrographic Office chart backdrop at a scale of 1:75,000 for the whole area was £458 incl. VAT. 7. Viewing all of the video cassettes to note habitats and biological communities, even by an experienced marine biologist, would take at least in the order of 200 hours and is not recommended. English Channel towed sledge seabed images. Phase 1: scoping study and example analysis. 6 8. Once colour transparencies are scanned and indexed, viewing to identify seabed habitats and biological communities would probably take about 100 hours for an experienced marine biologist and is recommended. 9. It is expected that identifying biotopes along approximately 1 km lengths of each tow would be feasible although uncertainties about Decca co-ordinate corrections and exact positions of images most likely gives a ±250 m position error. More work to locate each image accurately and solve the Decca correction question would improve accuracy of image location. 10. Using codings (produced by Holme to identify different seabed types), and some viewing of video and transparency material, 10 biotopes have been identified, although more would be added as a result of full analysis. 11. Using the data available from the Holme archive, it is possible to populate various fields within the Marine Recorder database. The overall ‘survey’ will be ‘English Channel towed video sled survey’. The ‘events’ become the 104 tows. Each tow could be described as four samples, i.e. the start and end of the tow and two areas in the middle to give examples along the length of the tow. These samples would have their own latitude/longitude co-ordinates. The four samples would link to a GIS map. 12. Stills and video clips together with text information could be incorporated into a multimedia presentation, to demonstrate the range of level seabed types found along a part of the northern English Channel. More recent images taken during SCUBA diving of reef habitats in the same area as the towed sledge surveys could be added to the Holme images.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Currently new digital tools used in architecture are often at the service of a conception of architecture as a consumer society’s cultural good. Within this neoliberal cultural frame, architects’ social function is no longer seen as the production of urban facts with sense of duty, but as a part within the symbolic logic that rules the social production of cultural values as it was defined by Veblen and developed by Baudrillard. As a result, the potential given by the new digital tools used in representation has shifted from an instrument used to verify a built project to two different main models: At the one hand the development of pure virtual architectures that are exclusively configured within their symbolic value as artistic “images” easily reproducible. On the other hand the development of all those projects which -even maintaining their attention to architecture as a built fact- base their symbolic value on the author’s image and on virtual aesthetics and logics that prevail over architecture’s materiality. Architects’ sense of duty has definitely reached a turning point.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

BACKGROUND:
tissue MicroArrays (TMAs) are a valuable platform for tissue based translational research and the discovery of tissue biomarkers. The digitised TMA slides or TMA Virtual Slides, are ultra-large digital images, and can contain several hundred samples. The processing of such slides is time-consuming, bottlenecking a potentially high throughput platform.
METHODS:
a High Performance Computing (HPC) platform for the rapid analysis of TMA virtual slides is presented in this study. Using an HP high performance cluster and a centralised dynamic load balancing approach, the simultaneous analysis of multiple tissue-cores were established. This was evaluated on Non-Small Cell Lung Cancer TMAs for complex analysis of tissue pattern and immunohistochemical positivity.
RESULTS:
the automated processing of a single TMA virtual slide containing 230 patient samples can be significantly speeded up by a factor of circa 22, bringing the analysis time to one minute. Over 90 TMAs could also be analysed simultaneously, speeding up multiplex biomarker experiments enormously.
CONCLUSIONS:
the methodologies developed in this paper provide for the first time a genuine high throughput analysis platform for TMA biomarker discovery that will significantly enhance the reliability and speed for biomarker research. This will have widespread implications in translational tissue based research.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Background: Digital pathology provides a digital environment for the management and interpretation of pathological images and associated data. It is becoming increasing popular to use modern computer based tools and applications in pathological education, tissue based research and clinical diagnosis. Uptake of this new technology is stymied by its single user orientation and its prerequisite and cumbersome combination of mouse and keyboard for navigation and annotation.

Methodology: In this study we developed SurfaceSlide, a dedicated viewing platform which enables the navigation and annotation of gigapixel digitised pathological images using fingertip touch. SurfaceSlide was developed using the Microsoft Surface, a 30 inch multitouch tabletop computing platform. SurfaceSlide users can perform direct panning and zooming operations on digitised slide images. These images are downloaded onto the Microsoft Surface platform from a remote server on-demand. Users can also draw annotations and key in texts using an on-screen virtual keyboard. We also developed a smart caching protocol which caches the surrounding regions of a field of view in multi-resolutions thus providing a smooth and vivid user experience and reducing the delay for image downloading from the internet. We compared the usability of SurfaceSlide against Aperio ImageScope and PathXL online viewer.

Conclusion: SurfaceSlide is intuitive, fast and easy to use. SurfaceSlide represents the most direct, effective and intimate human–digital slide interaction experience. It is expected that SurfaceSlide will significantly enhance digital pathology tools and applications in education and clinical practice.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The aim of this study was to explore the impact of interaction (through gathering local field data and engaging in remote reciprocal presentations) on aspects of multicultural awareness. Sixty-six 11-12-year-old Scottish primary school pupils collected data in the field from their local community through questionnaires, interviews, direct observation, digital images and video. From this they distilled a multimedia presentation, delivered by videoconference to a partner school in the USA, who reciprocated. There was some evidence of pre-post project gains in the complexity of the children's perceptions of their community environment, the ethnicity of their community, their own ethnicity, and news images. The children's use of language to define ethnicity also became more complex and their attitudes toward ethnic minorities became more inclusive. The implications for practice, policy and future research were explored. © 2004 Elsevier Ltd. All rights reserved.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Eight Creative Classroom (CCR) elements are used as a framework for analysing teachers’ current attitudes towards the use of moving images as a tool for teaching digital literacy to pupils aged 11-18 years in the context of ‘Creative Classrooms’. This paper reports on the challenges being faced by innovative teachers willing to adopt moving image (as a new ICT) into their teaching, and highlights the gaps currently present in the systemic support structures in schools which need to be addressed for innovative pedagogical practices to occur in these Creative Classrooms. By ensuring educators learn from their experiences of poor ICT uptake in the past and utilise these lessons for future innovations in classrooms, it is hoped that the transition to moving image, and its associated digital literacy skills, will be smooth and beneficial to the learners.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Aim (1)
A pilot study to determine the accuracy of interpretation of whole slide digital images in a broad range of general histopathology cases of graded complexity. (2) To survey the participating histopathologists with regard to acceptability of digital pathology.

Materials and methods
Glass slides of 100 biopsies and minor resections were digitally scanned in their entirety, producing digital slides. These cases had been diagnosed by light microscopy at least 1 year previously and were subsequently reassessed by the original reporting pathologist (who was blinded to their original diagnosis) using digital pathology. The digital pathology-based diagnosis was compared with the original glass slide diagnosis and classified as concordant, slightly discordant (without clinical consequence) or discordant. The participants were surveyed at the end of the study.

Results
There was concordance between the original light microscopy diagnosis and digital pathology-based diagnosis in 95 of the 100 cases while the remaining 5 cases showed only slight discordance (with no clinical consequence). None of the cases were categorised as discordant. Participants had mixed experiences using digital pathology technology.

Conclusions
In the broad range of cases we examined, digital pathology is a safe and viable method of making a primary histopathological diagnosis.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

In this article, we discuss our experiences of using photography and video while observing contentious parades and protests in Belfast. We show how our use of these methods drew us into a series of unplanned for non-verbal interactions with other event participants who were also freely and abundantly using photographic and filming equipment to capture their own images. This interactive use of photography and video affected us emotionally and influenced what we noticed and what we omitted in our observations. In particular, it forced us to reflect upon and question our role as researchers in the events we observed and in the changing balance of power between researchers and researched.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The Copney Stone Circle Complex, Co. Tyrone, N. Ireland, is an important Bronze Age site forming part of the Mid-Ulster Stone Circle Complex. The Environment Service: Historic Monuments and Buildings (ESHMB) initiated a program of bog-clearance in August 1994 to excavate the stone circles. This work was completed by October 1994 and the excavated site was surveyed in August 1995. Almost immediately, the rate at which the stones forming the circles were breaking down was noted and a program of study initiated to make recommendations upon the conservation of this important site. Digital photogrammetric techniques were applied to aerial images of the stone circles and digital terrain models created from the images at a range of scales. These provide base data sets for comparison with identical surveys to be completed in successive years and will allow the rate of deterioration, and the areas most affected, of the circles to be determined. In addition, a 2D analysis of the stones provides an accurate analysis of the absolute 2D dimensions of the stones for rapid desktop computer analysis by researchers remote from the digital photogrammetric workstation used in the survey.

The products of this work are readily incorporated into web sites, educational packages and databases. The technique provides a rapid and user friendly method of presentation of a large body of information and measurements, and a reliable method of storage of the information from Copney should it become necessary to re-cover the site.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

O objetivo deste trabalho foi efetuar um estudo de otimização dos parâmetros de exposição do mamógrafo digital da marca GE, modelo Senographe DS instalado no Instituto Português de Oncologia de Coimbra (IPOC) baseado numa análise contraste detalhe e avaliar o impacto do resultado obtido na melhoria da capacidade de detecção clínica das estruturas da mama. O mamógrafo em estudo dispõe de um sistema de controle automático da exposição designado por sistema AOP (Automatic Optimization of Parameters) que foi otimizado pelo fabricante a partir da razão contraste ruído. O sistema AOP é usado na prática clínica na quase totalidade dos exames de mamografia realizados no IPOC. Tendo em conta o tipo de estrutura que se pretende visualizar na mamografia, nomeadamente estruturas de baixo contraste como as massas e estruturas de dimensão submilimétrica como as microcalcificações, a análise contraste detalhe poderia constituir uma abordagem mais adequada para o estudo de otimização dos parâmetros de exposição uma vez que permitiria uma avaliação conjunta do contraste, da resolução espacial e do ruído da imagem. Numa primeira fase do trabalho foi efetuada a caracterização da prática clínica realizada no mamógrafo em estudo em termos de espessura de mama comprimida “típica”, dos parâmetros técnicos de exposição e das opções de processamento das imagens aplicadas pelo sistema AOP (combinação alvo/filtro, tensão aplicada na ampola - kVp e produto corrente-tempo da ampola - mAs). Numa segunda fase foi realizado um estudo de otimização da qualidade da imagem versus dose na perspectiva dos parâmetros físicos. Para tal foi efetuada uma análise contrastedetalhe no objeto simulador de mama CDMAM e usada uma figura de mérito definida a partir do IQFinv (inverted image quality figure) e da dose glandular média. Os resultados apontaram para uma diferença entre o ponto ótimo resultante do estudo de otimização e o ponto associado aos parâmetros de exposição escolhidos pelo sistema AOP, designadamente no caso da mama pequena. Sendo a qualidade da imagem na perspectiva clínica um conceito mais complexo cujo resultado da apreciação de uma imagem de boa qualidade deve ter em conta as diferenças entre observadores, foi efetuado na última parte deste trabalho um estudo do impacto clínico da proposta de otimização da qualidade de imagem. A partir das imagens realizadas com o objeto simulador antropomórfico TOR MAM simulando uma mama pequena, seis médicos(as) radiologistas com mais de 5 anos de experiência em mamografia avaliaram as imagens “otimizadas” obtidas utilizando-se os parâmetros técnicos de exposição resultantes do estudo de otimização e a imagem resultante da escolha do sistema AOP. A análise estatística das avaliações feitas pelos médicos indica que a imagem “otimizada” da mama pequena apresenta uma melhor visualização das microcalcificações sem perda da qualidade da imagem na deteção de fibras e de massas em comparação com a imagem “standard”. Este trabalho permitiu introduzir uma nova definição da figura de mérito para o estudo de otimização da qualidade da imagem versus dose em mamografia. Permitiu também estabelecer uma metodologia consistente que pode facilmente ser aplicada a qualquer outro mamógrafo, contribuindo para a área da otimização em mamografia digital que é uma das áreas mais relevantes no que toca à proteção radiológica do paciente.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Nous proposons de construire un atlas numérique 3D contenant les caractéristiques moyennes et les variabilités de la morphologie d’un organe. Nos travaux seront appliqués particulièrement à la construction d'un atlas numérique 3D de la totalité de la cornée humaine incluant la surface antérieure et postérieure à partir des cartes topographiques fournies par le topographe Orbscan II. Nous procédons tout d'abord par normalisation de toute une population de cornées. Dans cette étape, nous nous sommes basés sur l'algorithme de recalage ICP (iterative closest point) pour aligner simultanément les surfaces antérieures et postérieures d'une population de cornée vers les surfaces antérieure et postérieure d'une cornée de référence. En effet, nous avons élaboré une variante de l'algorithme ICP adapté aux images (cartes) de cornées qui tient compte de changement d'échelle pendant le recalage et qui se base sur la recherche par voisinage via la distance euclidienne pour établir la correspondance entre les points. Après, nous avons procédé pour la construction de l'atlas cornéen par le calcul des moyennes des élévations de surfaces antérieures et postérieures recalées et leurs écarts-types associés. Une population de 100 cornées saines a été utilisée pour construire l'atlas cornéen normal. Pour visualiser l’atlas, on a eu recours à des cartes topographiques couleurs similairement à ce qu’offrent déjà les systèmes topographiques actuels. Enfin, des observations ont été réalisées sur l'atlas cornéen reflétant sa précision et permettant de développer une meilleure connaissance de l’anatomie cornéenne.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Si la manière de produire une image depuis la reproductibilité technique a toujours été profondément déterminée par la captation d’une réalité physique, le numérique (qui constitue une méthode d’inscription visuelle distincte) devrait, en théorie, modifier la relation du spectateur à ces « nouvelles images ». Toutefois, en pratique, le spectateur fait-il l’expérience des images numériques d’une manière différente de celles issues de la captation? Afin de répondre à cette question, ce mémoire analyse, à l’aide de l’approche sémio-pragmatique, comment le spectateur a conditionné son regard à travers les techniques de la captation (photographie, cinéma et vidéo). Ensuite, cette étude compare les habitudes et les attentes visuelles engendrées par ces techniques aux images numériques. Enfin, cette étude situe le problème de la rupture dans une perspective plus large que celle des techniques afin de poser le questionnement dans toute une tradition de la représentation artistique.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The wealth of information available freely on the web and medical image databases poses a major problem for the end users: how to find the information needed? Content –Based Image Retrieval is the obvious solution.A standard called MPEG-7 was evolved to address the interoperability issues of content-based search.The work presented in this thesis mainly concentrates on developing new shape descriptors and a framework for content – based retrieval of scoliosis images.New region-based and contour based shape descriptor is developed based on orthogonal Legendre polymomials.A novel system for indexing and retrieval of digital spine radiographs with scoliosis is presented.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The interface of MgO/Ag(001) has been studied with density functional theory applied to slabs. We have found that regular MgO films show a small adhesion to the silver substrate, the binding can be increased in off-stoichiometric regimes, either by the presence of O vacancies at the oxide film or by a small excess of O atoms at the interface between the ceramic to the metal. By means of theoretical methods, the scanning tunneling microscopy signatures of these films is also analyzed in some detail. For defect free deposits containing 1 or 2 ML and at low voltages, tunnelling takes place from the surface Ag substrate, and at large positive voltages Mg atoms are imaged. If defects, oxygen vacancies, are present on the surface of the oxide they introduce much easier channels for tunnelling resulting in big protrusions and controlling the shape of the image, the extra O stored at the interface can also be detected for very thin films.