964 resultados para Deuteric fluids
Resumo:
Glibenclamide (GLIB), an oral antidiabetic medication of the sulphonylurea drugs family, was stoichiometrically imprinted using tetrabutylammonium methacrylate as the functional monomer, for the first time in molecular imprinting, and utilising the sulphonylurea affinity for carboxylate anions. Solution association between the drug and the novel functional monomer was studied by 1H-NMR titrations, whereby evidence of sulphonylurea deprotonation followed by the formation of “narcissistic” GLIB dimers was found when tested in CDCl3, while an affinity constant in excess of 105 L mol-1 was measured in DMSO-d6. Detailed analysis of GLIB binding on the subsequently prepared imprinted and non-imprinted polymers confirmed deactivation of binding sites by exchange of a proton between GLIB and methacrylate, followed by extraction of the tetrabutylammonium counterion from the polymer matrix, resulting in overall reduced binding capacities and affinities by the imprinted material under equilibrium conditions. An optimised MI-SPE protocol, which included a binding site re-activation step, was developed for the extraction of GLIB from blood serum, whereby recoveries of up to 92.4% were obtained with exceptional sample clean-up.
Resumo:
Os coeficientes de difusão (D 12) são propriedades fundamentais na investigação e na indústria, mas a falta de dados experimentais e a inexistência de equações que os estimem com precisão e confiança em fases comprimidas ou condensadas constituem limitações importantes. Os objetivos principais deste trabalho compreendem: i) a compilação de uma grande base de dados para valores de D 12 de sistemas gasosos, líquidos e supercríticos; ii) o desenvolvimento e validação de novos modelos de coeficientes de difusão a diluição infinita, aplicáveis em amplas gamas de temperatura e densidade, para sistemas contendo componentes muito distintos em termos de polaridade, tamanho e simetria; iii) a montagem e teste de uma instalação experimental para medir coeficientes de difusão em líquidos e fluidos supercríticos. Relativamente à modelação, uma nova expressão para coeficientes de difusão a diluição infinita de esferas rígidas foi desenvolvida e validada usando dados de dinâmica molecular (desvio relativo absoluto médio, AARD = 4.44%) Foram também estudados os coeficientes de difusão binários de sistemas reais. Para tal, foi compilada uma extensa base de dados de difusividades de sistemas reais em gases e solventes densos (622 sistemas binários num total de 9407 pontos experimentais e 358 moléculas) e a mesma foi usada na validação dos novos modelos desenvolvidos nesta tese. Um conjunto de novos modelos foi proposto para o cálculo de coeficientes de difusão a diluição infinita usando diferentes abordagens: i) dois modelos de base molecular com um parâmetro específico para cada sistema, aplicáveis em sistemas gasosos, líquidos e supercríticos, em que natureza do solvente se encontra limitada a apolar ou fracamente polar (AARDs globais na gama 4.26-4.40%); ii) dois modelos de base molecular biparamétricos, aplicáveis em todos os estados físicos, para qualquer tipo de soluto diluído em qualquer solvente (apolar, fracamente polar e polar). Ambos os modelos dão origem a erros globais entre 2.74% e 3.65%; iii) uma correlação com um parâmetro, específica para coeficientes de difusão em dióxido de carbono supercrítico (SC-CO2) e água líquida (AARD = 3.56%); iv) nove correlações empíricas e semi-empíricas que envolvem dois parâmetros, dependentes apenas da temperatura e/ou densidade do solvente e/ou viscosidade do solvente. Estes últimos modelos são muito simples e exibem excelentes resultados (AARDs entre 2.78% e 4.44%) em sistemas líquidos e supercríticos; e v) duas equações preditivas para difusividades de solutos em SC-CO2, em que os erros globais de ambas são inferiores a 6.80%. No global, deve realçar-se o facto de os novos modelos abrangerem a grande variedade de sistemas e moléculas geralmente encontrados. Os resultados obtidos são consistentemente melhores do que os obtidos com os modelos e abordagens encontrados na literatura. No caso das correlações com um ou dois parâmetros, mostrou-se que estes mesmos parâmetros podem ser ajustados usando um conjunto muito pequeno de dados, e posteriormente serem utilizados na previsão de valores de D 12 longe do conjunto original de pontos. Uma nova instalação experimental para medir coeficientes de difusão binários por técnicas cromatográficas foi montada e testada. O equipamento, o procedimento experimental e os cálculos analíticos necessários à obtenção dos valores de D 12 pelo método de abertura do pico cromatográfico, foram avaliados através da medição de difusividades de tolueno e acetona em SC-CO2. Seguidamente, foram medidos coeficientes de difusão de eucaliptol em SC-CO2 nas gamas de 202 – 252 bar e 313.15 – 333.15 K. Os resultados experimentais foram analisados através de correlações e modelos preditivos para D12.
Resumo:
First year nursing students repeatedly have difficulty recalling, understanding, and applying knowledge from the Fluids & Electrolytes (F&E) class. Although the traditional teaching method of lecturing is appropriate in a situation of knowledge acquisition, this situation refers to a broader context. An alternate teaching method is needed to increase students' understanding of the previously acquired knowledge and its application. This research concerns gaming as a tool for teaching with the focus on process as well as product. An instructional exercise, in the Jeopardy format, is designed to incorporate understanding (through problem-solving), group collaboration, and metacognition. Constructivist philosophy is combined with Instructional Design to construct an exercise that focuses not only on knowledge recall, but also emphasizes thinking, understanding, and the reflective nature of the exercise. The focus of this research is to design and evaluate an exercise as a supplemental teaching method to the lecture presentation of the F&E class.
Resumo:
Tese de doutoramento, Farmácia (Tecnologia Farmacêutica), Universidade de Lisboa, Faculdade de Farmácia, 2015
Resumo:
This study aimed to carry out experimental work to determine, for Newtonian and non-Newtonian fluids, the friction factor (fc) with simultaneous heat transfer, at constant wall temperature as boundary condition, in fully developed laminar flow inside a vertical helical coil. The Newtonian fluids studied were aqueous solutions of glycerol, 25%, 36%, 43%, 59% and 78% (w/w). The non-Newtonian fluids were aqueous solutions of carboxymethylcellulose (CMC), a polymer, with concentrations of 0.2%, 0.3%, 0.4% and 0.6% (w/w) and aqueous solutions of xanthan gum (XG), another polymer, with concentrations of 0.1% and 0.2% (w/w). According to the rheological study done, the polymer solutions had shear-thinning behavior and different values of viscoelasticity. The helical coil used has an internal diameter, curvature ratio, length and pitch, respectively: 0.00483 m, 0.0263, 5.0 m and 11.34 mm. It was concluded that the friction factors, with simultaneous heat transfer, for Newtonian fluids can be calculated using expressions from literature for isothermal flows. The friction factors for CMC and XG solutions are similar to those for Newtonian fluids when the Dean number, based in a generalized Reynolds number, is less than 80. For Dean numbers higher than 80, the friction factors of the CMC solutions are lower those of the XG solutions and of the Newtonian fluids. In this range the friction factors decrease with the increase of the viscometric component of the solution and increase for increasing elastic component. The change of behavior at Dean number 80, for Newtonian and non-Newtonian fluids, is in accordance with the study of Ali [4]. There is a change of behavior at Dean number 80, for Newtonian and non-Newtonian fluids, which is in according to previous studies. The data also showed that the use of the bulk temperature or of the film temperature to calculate the physical properties of the fluid has a residual effect in the friction factor values.
Resumo:
This study aimed to carry out experimental work to obtain, for Newtonian and non-Newtonian fluids, heat transfer coefficients, at constant wall temperature as boundary condition, in fully developed laminar flow inside a helical coil. The Newtonian fluids studied were aqueous solutions of glycerol, 25%, 36%, 43%, 59% and 78% (w/w) and the non-Newtonian fluids aqueous solutions of carboxymethylcellulose (CMC), a polymer, with concentrations 0.1%, 0.2%, 0.3%, 0.4% and 0.6% (w/w) and aqueous solutions of xanthan gum (XG), another polymer, with concentrations 0.1% and 0.2% (w/w). According to the rheological study performed, the polymer solutions had shear thinning behavior and different values of elasticity. The helical coil used has internal diameter, curvature ratio, length and pitch, respectively: 0.004575 m, 0.0263, 5.0 m and 11.34 mm. The Nusselt numbers for the CMC solutions are, on average, slightly higher than those for Newtonian fluids, for identical Prandtl and generalized Dean numbers. As outcome, the viscous component of the shear thinning polymer tends to potentiate the mixing effect of the Dean cells. The Nusselt numbers of the XG solutions are significant lower than those of the Newtonian solutions, for identical Prandtl and generalized Dean numbers. Therefore, the elastic component of the polymer tends to diminish the mixing effect of the Dean cells. A global correlation, for Nusselt number as a function of Péclet, generalized Dean and Weissenberg numbers for all Newtonian and non-Newtonian solutions studied, is presented.
Resumo:
Furosemide (FD: Lasix) is a loop diuretic which strongly increases both urine flow and electrolyte urinary excretion. Healthy volunteers were administered 40 mg orally (dissolved in water) and concentrations of FD were determined in serum and urine for up to 6 h for eight subjects, who absorbed water at a rate of 400 ml/h. Quantification was performed by HPLC with fluorescence detection (excitation at 233 nm, emission at 389 nm) with a limit of detection of 5 ng/ml for a 300-microliters sample. The elution of FD was completed within 4 min using a gradient of acetonitrile concentration rising from 30 to 50% in 0.08 M phosphoric acid. The delay to the peak serum concentration ranged from 60 to 120 min. FD was still easily measurable in the sera from all subjects 6 h after administration. In urine, the excretion rates reached their maximum between 1 and 3 h. The total amount of FD excreted in the urine averaged 11.2 mg (range 7.6-14.0 mg), with a mean urine volume of 3024 ml (range 2620-3596 ml). Moreover, the urine density was lower than 1.010 (recommended as an upper limit in doping analysis to screen diuretics) only for 2 h. An additional volunteer was administered 40 mg of FD and his urine was collected over a longer period. FD was still detectable 48 h after intake. Gas chromatography-mass spectrometry with different types of ionization was used to confirm the occurrence of FD after permethylation of the extract. Negative-ion chemical ionization, with ammonia as reactant gas, was found to be the most sensitive method of detection.
Resumo:
Tesis (Doctor en Ingeniería de Materiales) UANL, 2014.
The Inertio-Elastic Planar Entry Flow of Low-Viscosity Elastic Fluids in Micro-fabricated Geometries
Resumo:
The non-Newtonian flow of dilute aqueous polyethylene oxide (PEO) solutions through microfabricated planar abrupt contraction-expansions is investigated. The contraction geometries are fabricated from a high-resolution chrome mask and cross-linked PDMS gels using the tools of soft-lithography. The small length scales and high deformation rates in the contraction throat lead to significant extensional flow effects even with dilute polymer solutions having time constants on the order of milliseconds. The dimensionless extra pressure drop across the contraction increases by more than 200% and is accompanied by significant upstream vortex growth. Streak photography and videomicroscopy using epifluorescent particles shows that the flow ultimately becomes unstable and three-dimensional. The moderate Reynolds numbers (0.03 ⤠Re ⤠44) associated with these high Deborah number (0 ⤠De ⤠600) microfluidic flows results in the exploration of new regions of the Re-De parameter space in which the effects of both elasticity and inertia can be observed. Understanding such interactions will be increasingly important in microfluidic applications involving complex fluids and can best be interpreted in terms of the elasticity number, El = De/Re, which is independent of the flow kinematics and depends only on the fluid rheology and the characteristic size of the device.
Resumo:
Aquest projecte té com a objectiu la simulació numérica de la carrosseria d’ un vehicle de curses de muntanya de categoria CM
Resumo:
QUAGMIRE is a quasi-geostrophic numerical model for performing fast, high-resolution simulations of multi-layer rotating annulus laboratory experiments on a desktop personal computer. The model uses a hybrid finite-difference/spectral approach to numerically integrate the coupled nonlinear partial differential equations of motion in cylindrical geometry in each layer. Version 1.3 implements the special case of two fluid layers of equal resting depths. The flow is forced either by a differentially rotating lid, or by relaxation to specified streamfunction or potential vorticity fields, or both. Dissipation is achieved through Ekman layer pumping and suction at the horizontal boundaries, including the internal interface. The effects of weak interfacial tension are included, as well as the linear topographic beta-effect and the quadratic centripetal beta-effect. Stochastic forcing may optionally be activated, to represent approximately the effects of random unresolved features. A leapfrog time stepping scheme is used, with a Robert filter. Flows simulated by the model agree well with those observed in the corresponding laboratory experiments.
Resumo:
Gross cystic breast disease (GCBD) is the most common benign breast disorder, but the molecular basis of cyst formation remains to be identified. If the use of aluminium-based antiperspirant salts is involved in the etiology of gross breast cyst formation, it might be expected that aluminium would be at elevated levels in human breast cyst fluid (BCF). Aluminium was measured by ICP-MS in 48 samples of BCF, 30 samples of human blood serum and 45 samples of human breast milk at different stages of lactation (colostrum, intermediate, mature). The median level of aluminium in apocrine type I BCF (n:= 27, 150 mu g I-1) was significantly higher than in transuclative type II BCF (n = 21, 32 mu g I-1; P < 0.0001). By comparison, aluminium measurements gave a median concentration of 6 mu g I-1 in human serum and 25 mu g I-1 in human breast milk, with no difference between colostrum, intermediate and mature milk. Levels of aluminium were significantly higher in both types of BCF than in human serum (P < 0.0001). However when compared with human breast milk, aluminium levels were only significantly higher in apocrine type I BCF (P < 0.0001) and not in transudative type II BCF (P = 0.152). It remains to be identified why such high levels of aluminium were found in the apocrine type I BCF and from where the aluminium originated. However, if aluminium-based antiperspirants are found to be the source and to play any causal role in development of breast cysts, then it might become possible to prevent this common breast disorder. Copyright (C) 2008 John Wiley & Sons, Ltd.