248 resultados para Detectores quimicos
Resumo:
The Biosusceptometry AC (BAC) is a research tool that has been extensively explored by the group Biomagnetism IBB-UNESP for monitoring of the gastrointestinal tract, its response to a known drug or in vivo performance of solid dosage forms. During this period the BAC, which has the characteristics of high sensitivity and low cost, has been developed primarily for recording signals contraction of activity and traffic human gastrointestinal tract. With the possibility of producing images with this instrumentation, it was possible to evaluate different situations in vitro and in vivo for physiological studies and pharmaceuticals. Considering the good performance of this system to produce planar images, the first aim of the BAC system tomography (TBAC) was to evaluate the system performance of BAC to produce tomographic images of phantoms ferromagnetic for a single channel system. All these applications were only possible because of their sensitivity to materials of high magnetic suscepitibility as ferrite, which allow to produce an electrical signal proportional to the variation of the magnetic flux generated by the presence of magnetic marker next to a first-order gradiometer. Measuring this variation at various points was possible to generate planar images that recently came to be produced in systems with multiple detectors, said multi-channels. From planar images, also producing tomographic images of simulators BAC bars in a system of 13 channels using only the center channel, with good results when applied to simple objects as one and two bars. When testing the resolution of the system with more elaborate forms the quality and resolution of images reconstructed is not satisfactory, which would be solved by increasing the spatial sampling rate and hence the acquisition time. The present system works with an acquisition time of about five hours. Whereas this system will be applied for in vivo experiments, the acquisition time became a ...
Resumo:
The objective of this work was to develop a numerical method to solve boundary value problems concerning to the use of dispersion model for describing the hydraulic behavior of chemical or biological reactors employed in the wastewater treatment. The numerical method was implemented in FORTRAN language generating a computational program which was applied to solve cases involving reaction kinetics of both integer and fractional orders. The developed method was able to solve the proposed problems evidencing to be a useful tool that provides more accurate design of wastewater treatment reactors
Resumo:
In this work, it is presented a novel method for calculating some intrinsic parameters such as capture mean time, thermic emission mean time, capture probability and noise gain on quantum well infrared photodetectors. Such devices are built by depositing layers of semiconductors of different energy gap, forming quantum wells. The present method uses rate equations to describe the occupation of discrete states of the quantum wells, that together with noise gain equations given in literature, are solved self consistently. The input data of the method is experimental measurement of dark current (current measured with no relevant incident photon) versus applied bias. In order to validate this approach, the values obtained were compared with results from literature
Resumo:
Apocynin has been used as an efficient inhibitor of the multi-enzymatic complex NADPH oxidase in many experimental models involving phagocytic and nonphagocytic cells. The mechanism of inhibition has been linked with the previous activation of apocynin through the action of cellular peroxidases leading to the formation of a dimeric oxidation product, diapocynin. In this study we compared apocynin with pure diapocynin regarding their effects as scavenger of hydrogen peroxide and hypochlorous generated by glucose/glucose oxidase and myeloperoxidase respectively, and as inhibitors of the production of hydrogen peroxide and hypochlorous acid by activated neutrophils. The production of hydrogen peroxide was measured by the oxidation of the fluorescent substance Amplex Red and the production of hypochlorous acid by was measured as taurine-chloramine derivative using the chromogenic substrate 3,3’,5,5’- tetramethylbenzidine (TMB). Neutrophils (1 x106 cells/mL) were pre-incubated in PBS buffer supplemented with 1 mM calcium chloride, 0.5 mM magnesium chloride, 1 mg/mL glucose and 5 mM taurine in the presence or absence of inhibitors. The reactions were triggered by adding the soluble stimulus Forbol Miristate Acetate PMA or zymosan and incubated by additional 30 minutes. We found that pure diapocynin was not better than apocynin regarding its scavenger and inhibitory properties. These results suggest that the formation of diapocynin is not essential for the action of apocynin as inhibitor of NADPH oxidase activation
Resumo:
The biomagnetic techniques use different magnetic field detectors to measure parameters of the human physiology. Those techniques present the advantage of being noninvasive and radiation free. Among them we can show up the Superconducting Quantum Interference Device (SQUID), the Current Alternate Biosusceptometry (ACB) and, more recently, the employment of anisotropic magnetoresistive sensors. Those magnetic sensors have a low cost and good sensitivity to measure different physiological parameters using magnetic markers. The biomagnetic techniques have being used successfully through study on the characteristics of the gastrointestinal tract. Recent research, the magnetoresistors were used to evaluate the transit time and localization of magnetic sources in different parts of the gastrointestinal tract. The objective of this work is the characterization, with in vitro tests, of a biomagnetic instrumentation using two 3-axis magnetoresistors arranged in a gradiometric coplanar setup to evaluate esophageal transit time, analyze and compare the results of experimental signals and the magnetic theory, as well as evaluate the instrumentation gain with use of tri-axial sensor front to the mono-axial sensor. The instrumentation is composed by two three-axis sensing magnetometers, precision power supply and amplifier electronic circuits. The sensors fixed in a coplanar setup were separate by distance of 18 cm. The sensitivity tests had been carried through using a cylindrical magnet (ø = 4 mm and h = 4 mm) of neodymium-iron-boron (grid 35). The tests were done moving the permanent magnet on the sensors parallel axis, simulating the food transit in... (Complete abstract click electronic access below)
Resumo:
The use of physical characteristics for human identification is known as biometrics. Among the many biometrics traits available, the fingerprint is the most widely used. The fingerprint identification is based on the impression patterns, as the pattern of ridges and minutiae, characteristics of first and second levels respectively. The current identification systems use these two levels of fingerprint features due to the low cost of the sensors. However, the recent advances in sensor technology, became possible to use third level features present within the ridges, such as the perspiration pores. Recent studies show that the use of third-level features can increase security and fraud protection in biometric systems, since they are difficult to reproduce. In addition, recent researches have also focused on multibiometrics recognition due to its many advantages. The goal of this research project was to apply fusion techniques for fingerprint recognition in order to combine minutia, ridges and pore-based methods and, thus, provide more robust biometrics recognition systems, and also to develop an automated fingerprint identification system using these three methods of recognition. We evaluated isotropic-based and adaptive-based automatic pore extraction methods, and the fusion of pore-based method with the identification methods based on minutiae and ridges. The experiments were performed on the public database PolyUHRF and showed a reduction of approximately 16% in the EER compared to the best results obtained by the methods individually
Resumo:
The Boron Neutron Capture Therapy (BNCT), based on the 10B(n,α)7Li reaction, represents a promising modality for the treatment of cancers that are resistents to conventional treatments. So, it is necessary to find drugs (boron compounds) with high selectivity for each type of cancer, the neutrons source should be well characterized and the rate of 10B(n,α)7Li reaction should be measured with great accuracy as possible. This study aimed to develop a method for manufacturing thin films of boron, for measure the 10B(n,α)7Li reaction, and analyze the uniformity of the films. Five thin films of boron were manufactured with three different concentrations of boric acid, heated to transform the acid in boron, irradiated with thermic neutrons coupled to CR-39 detectors, in BNCT line at the reactor IEA-R1 IPEN/CNEN, São Paulo. After the irradiation, the detectors were chemically attacked with NaOH to reveal the tracks. The methodology presented is effective because it resulted in deposition of boron as thin film enabling the quantitative analysis of 10B(n,α)7Li reaction. The analysis of the uniformity of density of the induced tracks in CR-39 shows that, in most of the films, there is no uniformity in surface distribution of boron, but when the film is divided, we obtain some uniform sectors
Resumo:
In this work was developed a program capable of performing automatic counting of vehicles on roads. The problem of counting vehicles is using expensive techniques for its realization, techniques which often involve manual counting or degradation of the pavement. The main motivation for this work was the importance that the vehicle counting represents to the Traffic Engineer, being essential to analyze the performance of the roads, allowing to measure the need for installation of traffic lights, roundabouts, access ways, among other means capable of ensuring a continuous flow and safe for vehicles. The main objective of this work was to apply a statistical segmentation technique recently developed, based on a nonparametric linear regression model, to solve the segmentation problem of the program counter. The development program was based on the creation of three major modules, one for the segmentation, another for the tracking and another for the recognition. For the development of the segmentation module, it was applied a statistical technique combined with the segmentation by background difference, in order to optimize the process. The tracking module was developed based on the use of Kalman filters and application of simple concepts of analytical geometry. To develop the recognition module, it was used Fourier descriptors and a neural network multilayer perceptron, trained by backpropagation. Besides the development of the modules, it was also developed a control logic capable of performing the interconnection among the modules, mainly based on a data structure called state. The analysis of the results was applied to the program counter and its component modules, and the individual analysis served as a means to establish the par ameter values of techniques used. The find result was positive, since the statistical segmentation technique proved to be very useful and the developed program was able to count the vehicles belonging to the three goal..
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
Thermosetting resins are very important in the production of MDF panels. They act as an adhesive in the process of compacting and consolidating the fiberboard. Thermoset resins commonly used in this process are based resin urea formaldehyde (UF) and melamine formaldehyde (MF). The first has a higher demand due to its low cost and good performance in meeting the specifications and standards. The second has a high cost compared to MF resin, but adds greater value to the MDF panel, because it gives greater moisture resistance. The process of manufacture of MDF boards was briefly presented in this study to facilitate the understanding of the work. Samples of thermosetting resins (UF and MF) were subjected to physical-chemical seeking to relate these results to the technological performance presented by their respective samples of MDF boards. Two other samples of MDF panels were subjected to physical and mechanical tests. Results were analyzed and related to the award of their respective thermoset resin. Instruments like Dahmos Trend Manager ® and Grecon Dax 5000 and TG - DSC analysis were used in this study to assist in the analysis of the results. It was observed that the results of the analysis of thermosetting resins were within the specified. Such resins do not directly influence the technological tests provided by the MDF panels, but it has been found that the process variables such as humidity and fiber production rate interfere with the performance of the resin accelerating the reaction and therefore their influence on the physical-mechanical properties of the panels MDF. Samples of MDF panels with UF and MF met all the specifications required by the Brazilian standard with regard to the technological quality. The increased demand for UF resin market is justified by the service specifications...
Resumo:
Desde o conhecimento da radiação e seus efeitos a necessidade de mensurá-la intriga os cientistas. Os detectores de radiação mais difundidos atualmente fazem o uso de cristais semicondutores. Porém, esses detectores tem uma temperatura ótima de funcionamento que acaba sendo ultrapassada, já que o processo gera calor. Por isso, o resfriamento acaba sendo uma necessidade. O desenvolvimento de detectores de radiação com cristal semicondutor que opere a temperatura ambiente é tema de muitos estudos, já que evitaria o processo de resfriamento, trabalhoso e de alto custo. No Centro de Tecnologia das Radiações (CTR) do Instituto de Pesquisas Energéticas e Nucleares (IPEN) o sal de Brometo de Tálio (TlBr) é estudado para esta finalidade. Até ser um cristal semicondutor este sal deve passar por vários processos, entre eles o de purificação e o de cristalização. A técnica utilizada para purificar este cristal é a de Refino zonal. Após ser purificado por esta técnica o sal estará apto a ser cristalizado e consequentemente integrar um equipamento de detecção de radiação. Portanto, esta monografia teve como objetivo realizar a análise da segregação das impurezas do sal de TlBr através da técnica de espectroscopia de massa em fonte de plasma induzido (ICP-MS) e espectroscopia de emissão atômica (ICP-AES). Determinando assim se o mesmo está apto a ser cristalizado e vir a compor um detector de radiação
Resumo:
Companies that invest in current technologies maintain themselves updated, improve their business rules and anticipate themselves against rivals providing a better service to their customers. This project aims to develop an ERP - Enterprise Resource Planning module for Android which complements an existing manager system and, that attends the needs of a rental equipment business for civil building, i.e., it improves the communication channel company-client and betters the identification and control of products. During the developing of this project, it was necessary to study the company business rules, analyze the requirements and the appropriate technologies. This project was organized in two parts, contemplating e ach of these needs. It were implemented specific modules for generate budgets and pre-orders in the first part and, the use of radiofrequency tags in the second one. Thus, it was possible to assign mobility to company business rules so that a better rental service can be provided and the equipments can be better managed
Resumo:
Não possui
Resumo:
Nuclear medicine is a medical specialty related to imagery that deals with imaging techniques, diagnosis and therapy, allowing observing the physiological state of tissues noninvasively by marking the molecules participating of these physiological processes with radioactive isotopes, thus creating the called radionuclides. The image of a radionuclide is one of the most important applications of radioactivity in nuclear medicine. The equipment’s of nuclear medicine imaging use the principle of radiation detection, turning it into an electrical signal which, through specific algorithms, allows forming tomographic images that provide information about the functional status of organs. New detection systems have been developed for tomographic acquisitions using solid state detectors. These devices use crystals of cadmium zinc telluride (CdZnTe). Some of the advantages of this detector are a significant improvement of signal to noise ratio, the increased spectral and spatial resolution, which in sum, result in greater clarity of the images obtained, opening new perspectives for imaging protocols previously unattainable. In contrast, all other gamma-cameras equipped with vacuum tubes have remained relatively unchanged for nearly fifty years. In these gamma-cameras, the images are obtained using two steps significantly less efficient: the gamma rays are converted to light through a first device, and then the light is converted into an electrical signal through a second device. One of functions the Medical Physicist is related to the quality control of equipment. This control ensures that the information and images provided are true and thus credible to be used in medical reports. To perform this type of analysis the physicist must understand the performance characteristics and operation of all equipment of the department concerned; besides, in the absence of specific legislation, proposing...(Complete abstract click electronic access below)
Resumo:
Pós-graduação em Medicina Veterinária - FCAV