924 resultados para Derivation principle
Resumo:
Simple analytical formulas are introduced for the grid impedance of electrically dense arrays of square patches and for the surface impedance of high-impedance surfaces based on the dense arrays of metal strips or square patches over ground planes. Emphasis is on the oblique-incidence excitation. The approach is based on the known analytical models for strip grids combined with the approximate Babinet principle for planar grids located at a dielectric interface. Analytical expressions for the surface impedance and reflection coefficient resulting from our analysis are thoroughly verified by full-wave simulations and compared with available data in open literature for particular cases. The results can be used in the design of various antennas and microwave or millimeter wave devices which use artificial impedance surfaces and artificial magnetic conductors (reflect-array antennas, tunable phase shifters, etc.), as well as for the derivation of accurate higher-order impedance boundary conditions for artificial (high-) impedance surfaces. As an example, the propagation properties of surface waves along the high-impedance surfaces are studied.
Resumo:
Recent R-matrix calculations of electron impact excitation rates in Ar IV are used to calculate the emission-line ratio: ratio diagrams (R1, R2), (R1, R3), and (R1, R4), where K1 = I(4711 Å)/I(4740 Å), R2 = I(7238 Å)/I(4711 + 4740 Å), R3 = I(7263 Å)/I(4711 + 4740 Å), and R4 = I(7171 Å)/I(4711 + 4740 Å), for a range of electron temperatures (Te = 5000-20,000 K) and electron densities (Ne = 10-106 cm-3) appropriate to gaseous nebulae. These diagrams should, in principle, allow the simultaneous determination of Te and Ne from measurements of the [Ar IV] lines in a spectrum. Plasma parameters deduced for a sample of planetary nebulae from (R1, R3) and (R1, R4), using observational date obtained with the Hamilton echelle spectrograph on the 3 m Shane Telescope at the Lick Observatory, are found to show excellent internal consistency and to be in generally good agreement with the values of Te and Ne estimated from other line ratios in the echelle spectra. These results provide observational support for the accuracy of the theoretical ratios and, hence, the atomic data adopted in their derivation. In addition, they imply that the 7171 Å line is not as seriously affected by telluric absorption as previously thought. However, the observed values of R2 are mostly larger than the theoretical high-temperature and density limit, which is due to blending of the Ar IV 7237.54 Å line with the strong C II transition at 7236 Å.
Resumo:
Hardware synthesis from dataflow graphs of signal processing systems is a growing research area as focus shifts to high level design methodologies. For data intensive systems, dataflow based synthesis can lead to an inefficient usage of memory due to the restrictive nature of synchronous dataflow and its inability to easily model data reuse. This paper explores how dataflow graph changes can be used to drive both the on-chip and off-chip memory organisation and how these memory architectures can be mapped to a hardware implementation. By exploiting the data reuse inherent to many image processing algorithms and by creating memory hierarchies, off-chip memory bandwidth can be reduced by a factor of a thousand from the original dataflow graph level specification of a motion estimation algorithm, with a minimal increase in memory size. This analysis is verified using results gathered from implementation of the motion estimation algorithm on a Xilinx Virtex-4 FPGA, where the delay between the memories and processing elements drops from 14.2 ns down to 1.878 ns through the refinement of the memory architecture. Care must be taken when modeling these algorithms however, as inefficiencies in these models can be easily translated into overuse of hardware resources.
Resumo:
Adult tissue-derived mesenchymal stem cells ( MSCs) have demonstrated therapeutic efficacy in treating diseases or repairing damaged tissues through mechanisms thought to be mediated by either cell replacement or secretion of paracrine factors. Characterized, self- renewing human ESCs could potentially be an invariable source of consistently uniform MSCs for therapeutic applications. Here we describe a clinically relevant and reproducible manner of generating identical batches of hESC- derived MSC ( hESC- MSC) cultures that circumvents exposure to virus, mouse cells, or serum. Trypsinization and propagation of HuES9 or H1 hESCs in feeder- and serum-free selection media generated three polyclonal, karyotypically stable, and phenotypically MSC-like cultures that do not express pluripotency- associated markers but displayed MSC- like surface antigens and gene expression profile. They differentiate into adipocytes, osteocytes, and chondrocytes in vitro. Gene expression and fluorescence- activated cell sorter analysis identified CD105 and CD24 as highly expressed antigens on hESC- MSCs and hESCs, respectively. CD105+, CD24- monoclonal isolates have a typical MSC gene expression profiles and were identical to each other with a highly correlated gene expression profile ( r(2) >.90). We have developed a protocol to reproducibly generate clinically compliant and identical hESC- MSC cultures.
Resumo:
A simple dry chemistry time-resolved fluorescence immunoassay (TR-FIA) method was developed for the measurement of zeranol in bovine urine samples. The samples were purified by immunoaffinity chromatography and a specificity-enhanced zeranol antibody was employed in the immunoassay. This resulted in a highly selective method, which had only negligible reactivity with Fusarium spp, toxins. The all-in-one-well dry chemistry concept made the assay very simple to use because all the assay-specific reagents were already present in the reaction wells in dry form. Only the addition of diluted sample extract was required to perform the competitive one-step TR-FIA and the results were available in less than 1 h. The analytical limit of detection (mean + 3s) for the immunoassay was 0.16 ng ml(-1) (n=12) and the functional limit of detection for the whole method, estimated by the analysis of zeranol-free samples, was 1.3 ng ml(-1) (n=20). The recovery of zeranol at the level of 2 ng ml(-1) was 99% (n=18) and the within-assay variation ranged between 4.5 and 9.0%.
Resumo:
The temporal priority principle states that all causes must precede their effects. It is widely assumed that children's causal reasoning is guided by this principle from early in development. However, the empirical studies that have examined children's use of the principle, most of which were conducted some decades ago, in fact show inconsistent findings. Some researchers have argued that 3-year-olds reliably use this principle, whereas others have suggested that it is not until 5 years that children properly grasp the inviolability of the principle. To examine this issue, 100 children, 50 three-year-olds, and 50 four-year-olds, took part in a study in which they had to judge which of two causes yielded an effect. In the task, children saw one event (A), an effect (E), and then another event (B). The events A and B involved the rolling of balls down runways, and the effect E was a Jack-in-a-box popping up. The extent to which E left a visible trace was also varied, because comparisons across previous studies suggested that this may affect performance. As a group, 3- and 4-year-olds performed at above-chance levels, but performance improved with age. The nature of the effect did not have a significant impact on performance. Although some previous studies suggested that 3-year-olds may be more likely to choose B rather than A as a cause due to a recency effect, we found no evidence of this pattern of performance in the younger group. Potential explanations of the age-related improvement in performance are discussed. © 2013 Desmet.
Resumo:
This paper proposes a calculation method to determine power system response during small load perturbations or minor disturbances. The method establishes the initial value of active power transient using traditional reduction technique on admittance matrix, which incorporates voltage variations in the determination. The method examines active power distribution among generators when several loads simultaneously change, and verifies that the superposition principle is applicable for this scenario. The theoretical derivation provided in the paper is validated by numerical simulations using a 3-generator 9-bus benchmark model. The results indicate that the inclusion of voltage variation renders an independent and precise measure of active power response during transient conditions.
Resumo:
This paper deals with the problem of estimating wave pressure loads acting on Oscillating Wave Surge Converters (OWSC) for assessment of fatigue on their components. Recent wave loading data issued from experimental testing of a 25th scale model of a box-shaped OWSC are here used to review the accuracy of the predictions made by an engineering method previously developed to derive wave pressure loads on OWSCs from experimental data. Predictions are shown underestimate wave pressure loads, and other methods subsequently developed are presented. A simplistic experimental method taking in consideration variations of the wetted surface area of the flap is shown to lead to relatively good estimates of wave pressure loads that could be used for fatigue calculations.