847 resultados para Cut-off operation
Resumo:
Smelt populations have been recorded since the 18th Century from at least 15 rivers in Scotland, but over the last Century the species has suffered a severe decline and has disappeared from all its former sites except the rivers Cree, Forth and Tay. These populations must now be regarded as having high conservation importance. There are probably several different reasons for this decline. In some rivers, such as the Clyde and the Stinchar, pollution in the lower reaches has prevented successful migration and reproduction. In other rivers, high weirs and barriers have completely cut off access to spawning grounds. In some estuaries and rivers, such as the Solway Firth, overfishing is believed to have been responsible for eliminating local stocks. A Species Action Plan for the smelt has been prepared and it is hoped that this will be the basis of a future conservation strategy for this species in Scotland.
Resumo:
Além de muito freqüente, a desnutrição associa-se a morbi/mortalidade em pacientes com doenças hepáticas crônicas. A avaliação do estado nutricional em hepatopatas é difícil pela sobrecarga hídrica e pela alteração na síntese protéica, fatores que alteram os parâmetros tradicionalmente usados na avaliação nutricional. Os objetivos são:a)avaliar o estado nutricional, através da AGS, antropometria, do escore de Mendenhall e da combinação de todos os instrumentos, em pacientes com doença hepática crônica; b)correlacionar o estado nutricional com a gravidade de doença hepática crônica; c)determinar a contribuição da dinamometria do aperto de mão para a avaliação do estado nutricional. Foram incluídos 305 pacientes portadores de doenças hepáticas crônicas, com idade de 18-80 anos, atendidos no ambulatório de doenças hepatobiliares do Hospital Universitátio Pedro Ernesto. A gravidade da doença hepática foi avaliada pela classificação de Child-Pugh e escore de Meld. Foram aferidos parâmetros antropométricos (peso, altura, índice de massa corporal, prega cutânea triciptal, circunferência do braço, circunferência muscular do braço), parâmetros bioquímicos (albumina e contagem total de linfócitos), Avaliação Global Subjetiva, escore de Mendenhall e força do aperto de mão pela dinamometria. Os valores da porcentagem de adequação dos parâmetros foram utilizados para a classificação da desnutrição. Consideramos todos os pacientes com porcentagens de adequação abaixo de 90% como desnutridos. Foi criado o escore risco de desnutrição que se caracterizou pela alteração em qualquer um dos parâmetros da avaliação nutricional. Cerca de 53% dos pacientes eram do sexo masculino, 43% portadores de cirrose hepática, 80% com etiologia viral e média de idade de 54 12 anos. Houve relação estatisticamente significativa entre a classificação funcional da doença hepática e a AGS, o escore de Mendenhall e o de risco de desnutrição. A avaliação isolada da antropometria não se correlacionou com a classificação funcional. Segundo a AGS, a prevalência de desnutrição foi de 10% na hepatopatia não cirrótica, 16% na cirrose compensada e 94% na cirrose descompensada. Segundo o escore de Mendenhall, as cifras foram de 31%, 38% e 56%, respectivamente. Segundo o novo escore, as cifras foram de 52%, 60% e 96%, respectivamente. Embora tenha havido uma redução estatisticamente significativa da força muscular com o agravamento do estado nutricional, não foi possível estabelecer um ponto de corte para os valores da dinamometria. A análise do desempenho do percentual de adequação da força muscular como critério diagnóstico de pacientes sob risco de desnutrição revelou provavelmente 56% de falso-positivos e 24% de falso-negativos. A grande variação na prevalência de desnutrição em pacientes com doença hepática depende do instrumento de avaliação nutricional usado e da classificação funcional da doença hepática. Não surpreendentemente, os escores combinados detectaram as maiores taxas de prevalência de desnutrição. Houve associação significativa entre o estado nutricional e a gravidade da doença hepática. O aumento das taxas de prevalência de desnutrição trazido pela dinamometria ocorreu às custas de resultados falso-positivos.
Resumo:
We propose a simple single-layer magnetic microtrap configuration which can trap an array of magnetically-trapped Bose-Einstein condensate. The configuration consists of two series of parallel wires perpendicular to each other and all of the crossing points are cut off for maintaining the uniformity of the current. We analyse the trapping potential, the position of trapping centres and the uniformity of the array of the traps. The trapping depth and trapping frequency with different parameters are also calculated. Lastly, the effect of the cut-off crossing points, dissipate power, chip production are introduced concisely.
Resumo:
O objetivo do presente estudo clínico é verificar a reprodutibilidade intra e interexaminadores de um critério de diagnóstico de cárie dentária (Nyvad et al. 1999) aplicado na dentição decídua, e avaliar o tempo médio necessário para a realização do exame clínico utilizando o referido critério. O mesmo é baseado na combinação de métodos visuais e táteis e propõe a diferenciação entre lesões ativas e inativas, tanto para lesões cavitadas quanto para não cavitadas. A amostra total consistiu de 80 crianças de três a sete anos de idade, de ambos os sexos, estudantes do Centro Educacional Terra Santa (Petrópolis/ RJ). Os responsáveis assinaram um termo de consentimento livre e esclarecido e o trabalho foi aprovado pelo Comitê de Ética em Pesquisa do HUPE-UERJ. Os exames foram realizados após escovação supervisionada, em consultório odontológico sob iluminação artificial, após 3-5s de secagem com ar comprimido, por dois examinadores treinados pelas autoras do índice e calibrados. As concordâncias intra e interexaminadores foram avaliadas pelo percentual de concordância (%) e pelo teste kappa (k), considerando a superfície dentária como unidade de análise e os seguintes pontos de corte: 1) hígida versus cariada; 2) ativa versus inativa; 3) descontinuidade versus hígida; e 4) cavitada versus hígida. O % e o valor de k para confiabilidade interexaminadores para cada ponto de corte foram: 1) % = 0,97 e k = 0,82 (IC: 0,80 - 0,85); 2) % = 0,98 e k = 0,80 (IC: 0,76 - 0,83); 3) % = 0,99 e k = 0,90 (IC: 0,88 - 0,93); 4) % = 99,0 e k = 0,95 (IC: 0,92 - 0,97). O % e o valor de k para confiabilidade intraexaminador para cada ponto de corte foram: 1) % = 0,98 e k = 0,86 (IC: 0,84 - 0,86); 2) % = 0,99 e k = 0,86 (IC: 0,83 - 0,89); 3) % = 0,99 e k = 0,94 (IC: 0,92 - 0,96); 4) % = 0,99 e k = 0,98 (IC: 0,96 - 0,99). O maior % de discordância (65,3% - 158/242) concentrou-se na diferenciação entre supefícies hígidas e lesões não cavitadas: 33,5% (81/242) entre superfície hígida e lesão não cavitada inativa; 26,0% (63/242), entre superfície hígida e lesão não cavitada ativa; e 5,8% (14/242), entre lesão não cavitada ativa e lesão não cavitada inativa. O tempo necessário para realização do exame clínico foi em média 226,5s (128,53). Conclui-se que o índice apresentou reprodutibilidade variando de substancial à quase perfeita e um tempo de exame viável, mostrando-se consistente e reproduzível para a realização de estudos clínicos de cárie dentária na dentição decídua.
Resumo:
This thesis aims at a simple one-parameter macroscopic model of distributed damage and fracture of polymers that is amenable to a straightforward and efficient numerical implementation. The failure model is motivated by post-mortem fractographic observations of void nucleation, growth and coalescence in polyurea stretched to failure, and accounts for the specific fracture energy per unit area attendant to rupture of the material.
Furthermore, it is shown that the macroscopic model can be rigorously derived, in the sense of optimal scaling, from a micromechanical model of chain elasticity and failure regularized by means of fractional strain-gradient elasticity. Optimal scaling laws that supply a link between the single parameter of the macroscopic model, namely the critical energy-release rate of the material, and micromechanical parameters pertaining to the elasticity and strength of the polymer chains, and to the strain-gradient elasticity regularization, are derived. Based on optimal scaling laws, it is shown how the critical energy-release rate of specific materials can be determined from test data. In addition, the scope and fidelity of the model is demonstrated by means of an example of application, namely Taylor-impact experiments of polyurea rods. Hereby, optimal transportation meshfree approximation schemes using maximum-entropy interpolation functions are employed.
Finally, a different crazing model using full derivatives of the deformation gradient and a core cut-off is presented, along with a numerical non-local regularization model. The numerical model takes into account higher-order deformation gradients in a finite element framework. It is shown how the introduction of non-locality into the model stabilizes the effect of strain localization to small volumes in materials undergoing softening. From an investigation of craze formation in the limit of large deformations, convergence studies verifying scaling properties of both local- and non-local energy contributions are presented.
Resumo:
[ES]Este trabajo pretende analizar la influencia que tiene la longitud de corte elegida y el filtro empleado en la medida de la rugosidad. Se realizan medidas de rugosidad en tres probetas que han sido sometidas a diferentes procesos de fabricación (fresado, rectificado y electroerosión). Además, se utilizan tres instrumentos diferentes para la medición. Tras realizar las medidas, se comparan los resultados y se extraen las conclusiones
Resumo:
研究了一种侧面抽运双包层光纤的方法,从被剥除了外包层、端面为350μm×400μm的D型双包层光纤内包层上切下长度为3mm的一段柱体,并胶合在相同的双包层光纤内包层的侧面上,构成了柱体-光纤侧面耦合器。半导体激光器的抽运光从该柱体的一端入射并通过它耦合进入双包层光纤的内包层,实验测得耦合器最大耦合效率为85%。该方法适用于输出功率为数瓦的光纤激光器和放大器的侧面抽运。
Resumo:
Novel GeS2-Ga2S3-AgCl chalcohalide glasses had been prepared by melt-quenching technique, and the glass-forming region was determined by XRD, which indicated that the maximum of dissolvable AgCl was up to 65 mol%. Thermal and optical properties of the glasses were studied by differential scanning calorimetry (DSC) and Visible-IR transmission, which showed that most of GeS2-Ga2S3-AgCl glasses had strong glass-forming ability and broad region of transmission (about 0.45-12.5 mu m). With the addition of AgCl, the glass transition temperature, Tg decreases distinctly, and the short-wavelength cut-off edge (lambda(vis)) of the glasses also shifts to the long wavelength gradually. However, the glass-forming ability of the glass has a complicated evolutional trend depended on the compositional change. In addition, the values of the Vickers microhardness, H (v) , which decrease with the addition of AgCl, are high enough for the practical applications. These excellent properties of GeS2-Ga2S3-AgCl glasses make them potentially applied in the optoelectronic field, such as all-optical switch, etc.
Resumo:
The Er3+/Yb3+ co-doped glasses with compositions of xBi(2)O(3)-(65-x)P2O5-4Yb(2)O(3)-11Al(2)O(3)-5BaO-15Na(2)O (where x = 0, 2.5, 5, 7.5 and 10 mol%) were prepared using the normal melt quench technique. The optical absorption spectra of the glasses were recorded in the wavelength range 300-1700 nm. The effect of Bi2O3 content on the thermal stability and absorption spectra of glasses was investigated. In addition, the Judd-Ofelt parameters and oscillator strengths were calculated by employing Judd-Ofelt theory. It was observed that the positions of the fundamental absorption edge and cut-off wavelength shifted towards red as the content of Bi2O3 increased. However, there were no red shifts found both in the peak wavelength and in the center of mass wavelength of all absorption bands with Bi2O3 content increasing. The results of Judd-Ofelt theory analysis showed that Judd-Ofelt parameters Omega(t), (t = 2, 4, 6) changed sharply when Bi2O3 concentration exceeded 5 mol%. The variation trends of experimental oscillator strength were similar with those of Judd-Ofelt parameters as function of Bi2O3 concentrations. Moreover, differential scanning calorimetry experiments showed that the increases of Bi2O3 content weakened the network structure and then lowered the thermal stability of the glasses. The spontaneous emission probability A(rad), branching ratio beta and the radiative lifetime tau(rad) were also calculated and analyzed. The stimulated emission cross-section of Er3+ was calculated according to the McCumber theory. It was found that the stimulated emission cross-section of Er3+ was monotonically increases with Bi2O3 content increasing. (C) 2006 Elsevier B.V. All rights reserved.
Resumo:
制备了一种新型的氧卤碲酸盐玻璃:(80-x)TeO2—15ZnCl2-xBaO-5NaF(x=30、20、10、0mol%),对玻璃的机械强度、热稳定性、拉曼光谱、紫外吸收光谱、红外透过光谱等特性进行了研究.通过拉曼光谱分析研究了玻璃组分含量的变化对玻璃结构和红外透过性能的影响.结果表明,随着BaO含量的增加,玻璃在红外波段透过率显著增加,并且红外透过截止波长向长波方向移动,本文对这一实验结果进行了机理性的研究探讨.同时,通过在熔制过程中通入高纯O2,以及引入适量的卤化物有效地除去玻璃中的[OH]基团,使
Resumo:
A adoção do plano dietético Dietary Approaches to Stop Hypertension (DASH) tem sido enfatizado na população hipertensa como uma importante estratégia no controle dos níveis pressóricos elevados. O objetivo deste estudo foi analisar o consumo alimentar de macro e micronutrientes em pacientes hipertensos, em especial do sódio, cálcio, potássio e magnésio, e comparar com as recomendações dietéticas contidas no plano DASH. Estudo transversal envolvendo uma amostra de conveniência composta por 113 hipertensos entre 40 e 69 anos. A medida da pressão arterial (PA) foi determinada com aparelho eletrônico devidamente calibrado e a avaliação dietética obtida pelo questionário de freqüência do consumo alimentar. Os alimentos ingeridos foram convertidos em porções e distribuídos em diferentes grupos alimentares. A faixa de porções recomendadas pelo plano DASH foi determinada com base na média das necessidades energéticas desta amostra permitindo assim uma posterior comparação com o hábito alimentar dos hipertensos, utilizando um escore de pontos com pontuação máxima de 9 pontos. A amostra foi dividida em três grupos: grupo B que obteve 2,5 a 4,0 pontos (n=34; 30%), grupo M entre 4,5 a 5,0 pontos (n=43; 38%) e grupo A que obteve 5,5 a 8,0 pontos (n=36; 32%). Não foram observadas diferenças significativas na média da PA sistólica (14024 vs 13823 vs 13515 mmHg) e diastólica (8617 vs 8813 vs 8410 mmHg). Apesar do grupo A consumir mais proteínas e gordura monoinsaturada, foi detectado um excesso pronunciado na ingestão de gordura saturada, colesterol e das calorias totais, por este grupo de pacientes. No que tange a ingestão dos micronutrientes, o grupo A apresentou consumo significativamente maior de cálcio, potássio e magnésio, refletido pela maior ingestão de vegetais e frutas em comparação aos grupos B e M. A média de ingestão do sódio intrínseco foi significativamente maior no grupo A (4,12,0 vs 3,11,1 vs 2,71,1 g/dia). Foram detectadas, apenas no grupo A, correlações entre PA sistólica e o percentual de proteína (r = -0,5; p=0,002) e PA sistólica e o percentual de carboidrato (r = 0,4; p=0,02). Apenas um terço dos hipertensos avaliados apresentaram padrão alimentar mais concordante com o plano DASH e com maior ingestão de proteínas, gordura monoinsaturada, fibras, cálcio, potássio e magnésio. Entretanto, o consumo mais elevado de sódio, gordura saturada, colesterol e das calorias totais por este grupo de pacientes poderia restringir uma maior queda dos níveis pressóricos elevados.
Resumo:
The authors give a picture of the average seasonal hydrographic situations over the Ivorian continental shelf using data provided by 26 cruises carried out from July 1969 to January 1972. They study meteorological conditions and the mechanism of setting of different types of hydrographic seasons defined as follows: a cold period related to an upwelling created by winds July to earlier October and a warm period divided in 2 parts in relation with haline variations: a low salinity period in November and December, and a high salinity period from January to May; this one sometimes cut off by short-timed drops in the temperature. Then precisions are given about seasonal and geographical variations using space-time diagrams: last, depth and intensity of the thermocline are examined.
Resumo:
The effects of post-deposited annealing on structure and optical properties of electron-beam evaporated Al2O3 single layers were investigated. The films were annealed in air for 1.5 h at different temperatures from 250 to 400 degrees C. The optical constants and cut-off wavelength were deduced. Microstructure of the samples was characterized by X-ray diffraction (XRD). Profile and surface roughness measurement instrument was used to determine the rms surface roughness. It was found that the cut-off wavelength shifted to short wavelength as the annealing temperature increased and the total optical loss decreased. The film structure remained amorphous even after annealing at 400 degrees C temperature and the samples annealed at higher temperature had the higher rms surface roughness. The decreasing total optical loss with annealing temperature was attributed to the reduction of absorption owing to oxidation of the film by annealing. Guidance to reduce the optical loss of excimer laser mirrors was given. (c) 2004 Elsevier B.V. All rights reserved.
Resumo:
abstract {LaF3 single-layer coatings were prepared by thermal boat evaporation at the deposition temperatures of 189, 255, 277 and 321°C respectively. The crystal structures of the coatings were characterized by X-ray diffraction (XRD). A spectrophotometer was employed to measure its transmittance. Moreover, refractive index, extinction coefficient and cut-off wavelength were obtained from the measured transmittance spectral curve. The residual stress was evaluated by the Stoney's equation and optical interferometer. Laser induce damage threshold (LIDT) was performed by a tripled Nd:YAG laser system. The results show that the crystallization status becomes better with the deposition temperature increasing. Correspondingly, the grain size also gets larger. Meanwhile, the coatings become more compact and the refractive index increases. However, the absorption of coatings seriously rises and the cut-off wavelength drifts to the long wave. In addition, the residual stress also increases and the intrinsic stress plays a determinant role in the coating. The LIDT of the coating also enhances at high temperature.}
Resumo:
研究了沉积温度对热舟蒸发氟化镧薄膜结构和光学性能的影响,沉积温度从200℃上升到350℃,间隔为50℃.采用分光光度计测量了样品的透射率和反射率光谱曲线,并在此基础上进行了光学损耗、光学常数以及带隙和截止波长的计算.采用表面轮廓仪进行了表面形貌和表面粗糙度的标定,采用X射线衍射(XRD)方法测量了不同沉积温度下样品的微结构.发现在短波长波段,随着沉积温度的升高,光学损耗增加,晶粒尺寸增大,表面粗糙度略有增加.不过散射损耗在光学损耗中所占比例均很小,光学损耗的增加主要由吸收损耗引起.随着沉积温度的升高,折射率与消光系数增大,带隙变小,相对应的截止波长向长波方向移动.