926 resultados para Crassostrea rhizophorae, anterior-posterior shell length


Relevância:

100.00% 100.00%

Publicador:

Resumo:

[EN]Three chemical methods for induction of relaxation in H. tuberculata coccinea (50-80mm shell length) were tested: sodium pentobarbital (60mg/l), 2-phenoxyethanol (2ml/l) and clove oil at three concentrations (0.02, 0.05 and 0,5ml/l). The time taken for animals to release from aquaria walls and recover from the anaesthetics was recorded. No mortality was observed after one week from experiment. All anaesthetics made animals release from container walls within 10-30 min, but they were ineffective as muscle relaxants, leaving the foot hard and contracted. The most effective concentration tested for clove oil was 0,5ml/l at 22ºC.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Die Zellgenealogie des Polychaeten Platynereis dumerilii wurde durch Farbstoffinjektion in die Blastomeren des 2-, 4- und 8-Zellstadiums, sowie die Zellen 2d, 2d112, 4d und 4d1 untersucht. Injektionen gelangen durch Aufweichung der Vitellinhülle mittels Dithioerythritol und Trypsin. Die injizierten Keime wurden zur Trochophora bzw zum dreisegmentigen Jungwurm aufgezogen, fixiert und mit dem konfokalen Rasterlichtmikroskop dreidimensional aufgenommen. Die animal-vegetale Achse des Frühkeims entspricht der antero-posterioren Achse des Jungwurms. Die Mikromeren des ersten Quartetts sind radiär um die antero-posteriore Achse angeordnet und bilden den Kopf. Die Mikromere 2d proliferiert bilateralsymmetrisch von der dorsalen Mittellinie aus und liefert das gesamte Rumpfektoderm. Indirekt ließ sich ableiten, daß die Mikromeren 2a1 bis 2c1 schmale ektodermale Streifen zwischen Kopf und Rumpf bilden und aus 2a2 und 2c2 das ektodermale Stomodaeum hervorgeht. Die Mikromeren des dritten Quartetts sowie möglicherweise 2b2 bilden 'Ektomesoderm'. 4d proliferiert ebenfalls bilateralsymmetrisch von der dorsalen Mittellinie aus zum Rumpfmesoderm und liefert vielleicht noch kleine Beiträge zum Aufbau des Darmes. Der Mitteldarm stammt von den dotterreichen Makromeren 4A bis 4D.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Osteoarticular allograft is one possible treatment in wide surgical resections with large defects. Performing best osteoarticular allograft selection is of great relevance for optimal exploitation of the bone databank, good surgery outcome and patient’s recovery. Current approaches are, however, very time consuming hindering these points in practice. We present a validation study of a software able to perform automatic bone measurements used to automatically assess the distal femur sizes across a databank. 170 distal femur surfaces were reconstructed from CT data and measured manually using a size measure protocol taking into account the transepicondyler distance (A), anterior-posterior distance in medial condyle (B) and anterior-posterior distance in lateral condyle (C). Intra- and inter-observer studies were conducted and regarded as ground truth measurements. Manual and automatic measures were compared. For the automatic measurements, the correlation coefficients between observer one and automatic method, were of 0.99 for A measure and 0.96 for B and C measures. The average time needed to perform the measurements was of 16 h for both manual measurements, and of 3 min for the automatic method. Results demonstrate the high reliability and, most importantly, high repeatability of the proposed approach, and considerable speed-up on the planning.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The effect of copper (Cu) filtration on image quality and dose in different digital X-ray systems was investigated. Two computed radiography systems and one digital radiography detector were used. Three different polymethylmethacrylate blocks simulated the pediatric body. The effect of Cu filters of 0.1, 0.2, and 0.3 mm thickness on the entrance surface dose (ESD) and the corresponding effective doses (EDs) were measured at tube voltages of 60, 66, and 73 kV. Image quality was evaluated in a contrast-detail phantom with an automated analyzer software. Cu filters of 0.1, 0.2, and 0.3 mm thickness decreased the ESD by 25-32%, 32-39%, and 40-44%, respectively, the ranges depending on the respective tube voltages. There was no consistent decline in image quality due to increasing Cu filtration. The estimated ED of anterior-posterior (AP) chest projections was reduced by up to 23%. No relevant reduction in the ED was noted in AP radiographs of the abdomen and pelvis or in posterior-anterior radiographs of the chest. Cu filtration reduces the ESD, but generally does not reduce the effective dose. Cu filters can help protect radiosensitive superficial organs, such as the mammary glands in AP chest projections.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Pelvic organ prolapse is a common condition among women with a prevalence of 11% and may affect the anterior, posterior, or apical compartment with a negative impact on sexual function.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Multiple sclerosis (MS) causes a broad range of neurological symptoms. Most common is poor balance control. However, knowledge of deficient balance control in mildly affected MS patients who are complaining of balance impairment but have normal clinical balance tests (CBT) is limited. This knowledge might provide insights into the normal and pathophysiological mechanisms underlying stance and gait. We analysed differences in trunk sway between mildly disabled MS patients with and without subjective balance impairment (SBI), all with normal CBT. The sway was measured for a battery of stance and gait balance tests (static and dynamic posturography) and compared to that of age- and sex-matched healthy subjects. Eight of 21 patients (38%) with an Expanded Disability Status Scale of 1.0-3.0 complained of SBI during daily activities. For standing on both legs with eyes closed on a normal and on a foam surface, patients in the no SBI group showed significant differences in the range of trunk roll (lateral) sway angle and velocity, compared to normal persons. Patients in the SBI group had significantly greater lateral sway than the no SBI group, and sway was also greater than normal in the pitch (anterior-posterior) direction. Sway for one-legged stance on foam was also greater in the SBI group compared to the no SBI and normal groups. We found a specific laterally directed impairment of balance in all patients, consistent with a deficit in proprioceptive processing, which was greater in the SBI group than in the no SBI group. This finding most likely explains the subjective symptoms of imbalance in patients with MS with normal CBT.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Patients with panic disorder (PD) have a bias to respond to normal stimuli in a fearful way. This may be due to the preactivation of fear-associated networks prior to stimulus perception. Based on EEG, we investigated the difference between patients with PD and normal controls in resting state activity using features of transiently stable brain states (microstates). EEGs from 18 drug-naive patients and 18 healthy controls were analyzed. Microstate analysis showed that one class of microstates (with a right-anterior to left-posterior orientation of the mapped field) displayed longer durations and covered more of the total time in the patients than controls. Another microstate class (with a symmetric, anterior-posterior orientation) was observed less frequently in the patients compared to controls. The observation that selected microstate classes differ between patients with PD and controls suggests that specific brain functions are altered already during resting condition. The altered resting state may be the starting point of the observed dysfunctional processing of phobic stimuli.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

A major unresolved question in developmental neurobiology is how the nervous system is adapted to the specific needs of the organism at different life stages. In the holometabolous insect Drosophila melanogaster, the larval ventral nervous system (VNS) is comprised of similar repeating segments, as opposed to the adult VNS, which varies greatly from segment to segment both in number and types of neurons. The adult-specific neurons of each segment are generated by 25 distinct types of neuronal progenitor cells called neuroblasts (NBs) that appear in a stereotyped array (Truman et al., 2004). Each NB divides repeatedly to produce a distinct set of daughter cells termed a lineage, which is bilaterally symmetric but present to varying degrees in each segment. These daughter cells can be distinguished by their position within the nervous system as well as by their axonal projections. Each of the 25 NBs produces neurons; if both daughter cells are present in a lineage then both sibling populations survived, whereas if only one projection is seen cell death occurred, leaving a hemilineage (half lineage). In some lineages, the same sibling type survives in all segments in which the lineage appears, but in others, the surviving sibling type varies across segments, resulting in a different morphology for the same lineage in different segments. How are these differences in survival and morphology controlled? The Hox genes provide positional information for developing structures along the anterior-posterior (AP) axis of animals. They encode transcription factors, thereby controlling the activity of genes down stream. In the postembryonic VNS, each NB lineage features its own characteristic expression pattern of Hox genes Antp and Ubx, which can vary from segment-to-segment, and can thereby cause variation in the number of neural cells and axonal projections that survive. This study defines the wild-type expression pattern of Antp and elucidates the role of Antp in gain of function studies. These studies are possible due to the MARCM (Mosaic Analysis with a Repressible Cell Marker) method, which allows the genetically manipulated cells to be specifically labeled in an otherwise normal, unlabeled organism. The results indicate that Antp is expressed in a segment-, lineage-, and hemilineage-specific manner. Antp is sufficient for both anterior and posterior transformations of particular lineages, including promotion of cell death and/or survival as well as axon guidance.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The ALX4 (aristaless-like homeobox 4) gene encodes a paired-type homeodomain transcriptional activator and plays a major role in anterior-posterior pattern formation during limb development. Here, the cloning, genomic structure and expression of the bovine ortholog of the ALX4 gene are reported. The bovine ALX4 gene consists of four exons and is located on BTA15q28-->q29 in a region syntenic to HSA11p11.2. The transcribed ALX4 mRNA encodes a 397-amino-acid protein showing a paired-type homeodomain and a C-terminal stretch of amino acids known as the OAR- or aristaless domain. The predicted protein shares 92.5% identity to human and mouse ALX4 proteins and all three species share almost complete identity in the conserved domains. ALX4 expression was detected by reverse transcriptase polymerase chain reaction in bovine fetal limb bones. The ALX4 gene was evaluated as a candidate gene for bovine syndactyly which has been mapped on the telomeric region of cattle chromosome 15. Sequencing of the four exons with flanking sequences of the bovine ALX4 gene from a panel of 14 affected animals belonging to German Holstein, German Fleckvieh and crossbreds, and 27 unaffected individuals from German Holstein revealed five silent SNPs within the coding region out of eleven SNPs in total. Four SNPs were polymorphic in the affected animals, but in comparison to the genotyped unaffected individuals the genotype distribution showed no evidence for an association to the phenotype. Therefore our data indicate that the ALX4 gene can probably be excluded as candidate gene for bovine syndactyly in the examined animals.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

OBJECTIVE: To design and evaluate a novel computer-assisted, fluoroscopy-based planning and navigation system for minimally invasive ventral spondylodesis of thoracolumbar fractures. MATERIALS AND METHODS: Instruments and an image intensifier are tracked with the SurgiGATE navigation system (Praxim-Medivision). Two fluoroscopic images, one acquired from anterior-posterior (AP) direction and the other from lateral-medial (LM) direction, are used for the complete procedure of planning and navigation. Both of them are calibrated with a custom-made software to recover their projection geometry and to co-register them to a common patient reference coordinate system, which is established by attaching an opto-electronically trackable dynamic reference base (DRB) on the operated vertebra. A bi-planar landmark reconstruction method is used to acquire deep-seated anatomical landmarks such that an intraoperative planning of graft bed can be interactively done. Finally, surgical actions such as the placement of the stabilization devices and the formation of the graft bed using a custom-made chisel are visualized to the surgeon by superimposing virtual instrument representations onto the acquired images. The distance between the instrument tip and each wall of the planned graft bed are calculated on the fly and presented to the surgeon so that the surgeon could formalize the graft bed exactly according to his/her plan. RESULTS: Laboratory studies on phantom and on 27 plastic vertebras demonstrate the high precision of the proposed navigation system. Compared with CT-based measurement, a mean error of 1.0 mm with a standard deviation of 0.1 mm was found. CONCLUSIONS: The proposed computer assisted, fluoroscopy-based planning and navigation system promises to increase the accuracy and reliability of minimally invasive ventral spondylodesis of thoracolumbar fractures.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The synchronization of dynamic multileaf collimator (DMLC) response with respiratory motion is critical to ensure the accuracy of DMLC-based four dimensional (4D) radiation delivery. In practice, however, a finite time delay (response time) between the acquisition of tumor position and multileaf collimator response necessitates predictive models of respiratory tumor motion to synchronize radiation delivery. Predicting a complex process such as respiratory motion introduces geometric errors, which have been reported in several publications. However, the dosimetric effect of such errors on 4D radiation delivery has not yet been investigated. Thus, our aim in this work was to quantify the dosimetric effects of geometric error due to prediction under several different conditions. Conformal and intensity modulated radiation therapy (IMRT) plans for a lung patient were generated for anterior-posterior/posterior-anterior (AP/PA) beam arrangements at 6 and 18 MV energies to provide planned dose distributions. Respiratory motion data was obtained from 60 diaphragm-motion fluoroscopy recordings from five patients. A linear adaptive filter was employed to predict the tumor position. The geometric error of prediction was defined as the absolute difference between predicted and actual positions at each diaphragm position. Distributions of geometric error of prediction were obtained for all of the respiratory motion data. Planned dose distributions were then convolved with distributions for the geometric error of prediction to obtain convolved dose distributions. The dosimetric effect of such geometric errors was determined as a function of several variables: response time (0-0.6 s), beam energy (6/18 MV), treatment delivery (3D/4D), treatment type (conformal/IMRT), beam direction (AP/PA), and breathing training type (free breathing/audio instruction/visual feedback). Dose difference and distance-to-agreement analysis was employed to quantify results. Based on our data, the dosimetric impact of prediction (a) increased with response time, (b) was larger for 3D radiation therapy as compared with 4D radiation therapy, (c) was relatively insensitive to change in beam energy and beam direction, (d) was greater for IMRT distributions as compared with conformal distributions, (e) was smaller than the dosimetric impact of latency, and (f) was greatest for respiration motion with audio instructions, followed by visual feedback and free breathing. Geometric errors of prediction that occur during 4D radiation delivery introduce dosimetric errors that are dependent on several factors, such as response time, treatment-delivery type, and beam energy. Even for relatively small response times of 0.6 s into the future, dosimetric errors due to prediction could approach delivery errors when respiratory motion is not accounted for at all. To reduce the dosimetric impact, better predictive models and/or shorter response times are required.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

OBJECTIVE: To evaluate quality of life and pelvic organ and sexual function before and during pessary use in patients with symptomatic pelvic organ prolapse and to determine reasons which lead to cessation of pessary use. DESIGN: Prospective observational study. SETTING: Tertiary referral center. PATIENT(S): Patients with symptomatic stage II or more prolapse of the anterior, posterior, or apical vaginal wall with or without uterus were included in this study. INTERVENTION(S): We used the Female Sexual Function Index questionnaire and the Sheffield prolapse questionnaire. For quality of life we used the King's Health Questionnaire. MAIN OUTCOME MEASURE(S): Main outcome measures were quality of life and sexual and pelvic organ function. RESULT(S): A total of 73 women participated in this study; 31 were sexually active. Desire, lubrication, and sexual satisfaction showed statistically significant improvement, and orgasm remained unchanged. Statistically significant improvement in the feeling of bulge occurred during therapy, stool outlet problems were significantly improved, overactive bladder symptoms were significantly better, and pessaries did not significantly alter incontinence. CONCLUSION(S): Pessaries have been shown to be a viable noninvasive treatment for pelvic organ prolapse improving organ and sexual function as well as general wellbeing.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Femoroacetabular impingements (FAI) are due to an anatomical disproportion between the proximal femur and the acetabulum which causes premature wear of the joint surfaces. An operation is often necessary in order to relieve symptoms such as limited movement and pain as well as to prevent or slow down the degenerative process. The result is dependent on the preoperative status of the joint with poor results for advanced arthritis of the hip joint. This explains the necessity for an accurate diagnosis in order to recognize early stages of damage to the joint. The diagnosis of FAI includes clinical examination, X-ray examination and magnetic resonance imaging (MRI). The standard X-radiological examination for FAI is carried out using two X-ray images, an anterior-posterior view of the pelvis and a lateral view of the proximal femur, such as the cross-table lateral or Lauenstein projections. It is necessary that positioning criteria are adhered to in order to avoid distortion artifacts. MRI permits an examination of the pelvis on three levels and should also include radial planned sequences for improved representation of peripheral structures, such as the labrum and peripheral cartilage. The use of contrast medium for a direct MR arthrogram has proved to be advantageous particularly for representation of labrum damage. The data with respect to cartilage imaging are still unclear. Further developments in technology, such as biochemical-sensitive MRI applications, will be able to improve the diagnosis of the pelvis in the near future.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

This paper presents a system for 3-D reconstruction of a patient-specific surface model from calibrated X-ray images. Our system requires two X-ray images of a patient with one acquired from the anterior-posterior direction and the other from the axial direction. A custom-designed cage is utilized in our system to calibrate both images. Starting from bone contours that are interactively identified from the X-ray images, our system constructs a patient-specific surface model of the proximal femur based on a statistical model based 2D/3D reconstruction algorithm. In this paper, we present the design and validation of the system with 25 bones. An average reconstruction error of 0.95 mm was observed.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

BACKGROUND: Lodox-Statscan is a whole-body, skeletal and soft-tissue, low-dose X-ray scanner Anterior-posterior and lateral thoraco-abdominal studies are obtained in 3-5 minutes with only about one-third of the radiation required for conventional radiography. Since its approval by the Food and Drug Administration (FDA) in the USA, several trauma centers have incorporated this technology into their Advanced Trauma Life Support protocols. This review provides a brief overview of the system, and describes the authors' own experience with the system. METHODS: We performed a PubMed search to retrieve all references with 'Lodox' and 'Stat-scan' used as search terms. We furthermore used the google search engine to identify existing alternatives. To the best of our knowledge, this is the only FDA-approved device of its kind currently used in trauma. RESULTS AND CONCLUSION: The intention of our review has been to sensitize the readership that such alternative devices exist. The key message is that low dosage full body radiography may be an alternative to conventional resuscitation room radiography which is usually a prelude to CT scanning (ATLS algorithm). The combination of both is radiation intensive and therefore we consider any reduction of radiation a success. But only the future will show whether LS will survive in the face of low-dose radiation CT scanners and magnetic resonance imaging devices that may eventually completely replace conventional radiography.