520 resultados para Containers


Relevância:

10.00% 10.00%

Publicador:

Resumo:

Existing benchmarking methods are time consuming processes as they typically benchmark the entire Virtual Machine (VM) in order to generate accurate performance data, making them less suitable for real-time analytics. The research in this paper is aimed to surmount the above challenge by presenting DocLite - Docker Container-based Lightweight benchmarking tool. DocLite explores lightweight cloud benchmarking methods for rapidly executing benchmarks in near real-time. DocLite is built on the Docker container technology, which allows a user-defined memory size and number of CPU cores of the VM to be benchmarked. The tool incorporates two benchmarking methods - the first referred to as the native method employs containers to benchmark a small portion of the VM and generate performance ranks, and the second uses historic benchmark data along with the native method as a hybrid to generate VM ranks. The proposed methods are evaluated on three use-cases and are observed to be up to 91 times faster than benchmarking the entire VM. In both methods, small containers provide the same quality of rankings as a large container. The native method generates ranks with over 90% and 86% accuracy for sequential and parallel execution of an application compared against benchmarking the whole VM. The hybrid method did not improve the quality of the rankings significantly.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

γ-Ray sources are among the most fundamental experimental tools currently available to modern physics. As well as the obvious benefits to fundamental research, an ultra-bright source of γ-rays could form the foundation of scanning of shipping containers for special nuclear materials and provide the bases for new types of cancer therapy.

However, for these applications to prove viable, γ-ray sources must become compact and relatively cheap to manufacture. In recent years, advances in laser technology have formed the cornerstone of optical sources of high energy electrons which already have been used to generate synchrotron radiation on a compact scale. Exploiting the scattering induced by a second laser, one can further enhance the energy and number of photons produced provided the problems of synchronisation and compact γ-ray detection are solved.

Here, we report on the work that has been done in developing an all-optical and hence, compact non-linear Thomson scattering source, including the new methods of synchronisation and compact γ-ray detection. We present evidence of the generation of multi-MeV (maximum 16–18 MeV) and ultra-high brilliance (exceeding 1020 photons s−1mm−2mrad−2 0.1% BW at 15 MeV) γ-ray beams. These characteristics are appealing for the paramount practical applications mentioned above.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Silver nanoparticles (AgNP) have been produced and applied in a variety of products ranging from personal care products to food package containers, clothing and medicine utilities. The antimicrobial function of AgNP makes it very useful to be applied for such purposes. Silver (Ag) is a non-essential metal for organisms, and it has been historically present in the environment at low concentrations. Those concentrations of silver increased in the last century due to the use of Ag in the photographic industry and lately are expected to increase due to the use of AgNPs in consumer products. The presence of AgNP in the aquatic environment may pose a risk for aquatic species, and the effects can vary from lethal to sublethal effects. Moreover, the contact of aquatic organisms with AgNP may not cause immediately the death of individuals but it can be accumulated inside the animals and consequently transferred within the food chain. Considering this, the objective of this work was to study the transfer of silver nanoparticles in comparison to silver ions, which was used as silver nitrate, within an aquatic food chain model. To achieve this goal, this study was divided into four steps: the toxicity assessment of AgNP and AgNO3 to aquatic test-species, the bioaccumulation assessment of AgNP and AgNO3 by Pseudokirchneriella subcapitata and Daphnia magna under different exposure scenarios, and finally the evaluation of the trophic transfer of Ag through an experimental design that included the goldfish Carassius auratus in a model trophic chain in which all the species were exposed to the worse-case scenario. We observed that the bioconcentration of Ag by P. subcapitata is mainly driven by ionic silver, and that algae cannot internalize these AgNPs, but it does internalizes dissolved Ag. Daphnia magna was exposed to AgNP and AgNO3 through different exposure routes: water, food and both water and food. The worse-case scenario for Daphnia Ag bioaccumulation was by the joint exposure of contaminated water and food, showing that Ag body burdens were higher for AgNPs than for AgNO3. Finally, by exposing C. auratus for 10 days through contaminated water and food (supplied as D. magna), with another 7 days of depuration phase, it was concluded that the 10 days of exposure were not enough for fish to reach a plateau on Ag internal concentration, and neither the 7 days of elimination were sufficient to cause total depuration of the accumulated Ag. Moreover, a higher concentration of Ag was found in the intestine of fish when compared with other organs, and the elimination rate constant of AgNP in the intestine was very low. Although a potential for trophic transfer of AgNP cannot be suggested based in the data acquired in this study, there is still a potential environmental risk for aquatic species.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

This work reports one possible way to develop new functional coatings used to increase the life time of metallic structures. The functionalities selected and attributed to model coatings in the frame of this work were corrosion protection, self-sensing and prevention of fouling (antifouling). The way used to confer those functionalities to coatings was based on the encapsulation of active compounds (corrosion inhibitors, pH indicators and biocides) in micro and nanocontainers followed by their incorporation into the coating matrices. To confer active corrosion protection, one corrosion inhibitor (2-mercaptobenzothiazole, MBT) was encapsulated in two different containers, firstly in silica nanocapsules (SiNC) and in polyurea microcapsules (PU-MC). The incorporation of both containers in different models coatings shows a significant improvement in the corrosion protection of aluminum alloy 2024 (AA2024). Following the same approach, SiNC and PU-MC were also used for the encapsulation of phenolphthalein (one well known pH indicator) to introduce sensing properties in polymeric coatings. SiNC and PU-MC containing phenolphthalein acted as corrosion sensor, showing a pink coloration due to the beginning of cathodic reaction, resulting in a pH increase identified by those capsules. Their sensing performance was proved in suspension and when integrated in coatings for aluminium alloy 2024 and magnesium alloy AZ31. In a similar way, the biocide activity (antifouling) was assigned to two polymeric matrices using SiNC for encapsulation of one biocide (Dichloro-2-octyl-2H-isothiazol-3-one, DCOIT) and also SiNC-MBT was tested as biocide. The antifouling activity of those two encapsulated compounds was assessed through inhibition and consequent decrease in the bioluminescence of modified E. coli. That effect was verified in suspension and when incorporated in coatings for AISI 1008 carbon steel. The developed micro and nanocontainers presented the desired performance, allowing the introduction of new functionalities to model coatings, showing potential to be used as functional additives in the next generation of multifunctional coatings.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Dissertação de mestrado, Aquacultura e Pescas, Faculdade de Ciências e Tecnologia, Universidade do Algarve, 2015

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The continued growth in the volume of international trade poses considerable economic and sustainability challenges, particularly as transport routes become more congested and concern grows about the role of transport movements in accelerating climate change. Rail freight plays a major role in the inland transport of containers passing through the main British container ports, and potentially could play a more significant role in the future. However, there is little detailed understanding of the nature of this particular rail market, especially in terms its current operating efficiency. This paper examines container train service provision to/from the four main ports, based on analysis of a representative survey of more than 500 container trains between February and August 2007. The extent to which the existing capacity is utilised is presented, and scenarios by which the number of containers carried could be increased without requiring additional train service provision are modelled, to identify the theoretical potential for greater rail volumes. Finally, the paper identifies the challenges involved in achieving higher load factors, emphasising the importance both of wider supply chain considerations and government policy decision-making.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

This paper examines the Producer Responsibility Obligations (Packaging Waste) Regulations introduced by the UK Government in 1997. The impact that these Regulations will have on the levels of freight transport activity associated with the collection and redistribution of packaging waste to recovery/recycling facilities is calculated. Findings indicate that the Regulations will lead to a 14% increase in freight vehicle kilometres attributable to packaging waste. The extent to which greater use of reusable containers could help to reduce packaging waste-related transport activity is also modelled. Details arc given of how businesses are responding to the Regulations and how some companies are adapting their logistics systems to incorporate the recovery and recycling of packaging waste as well as replacing disposal packaging with reusable containers. Interviews and case-study material carried out as part of the research are used to support this discussion.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Bisphenol A (BPA) is an endocrine disrupting chemical (EDC) whose migration from food packaging is recognized worldwide. However, the real overall food contamination and related consequences are yet largely unknown. Among humans, children’s exposure to BPA has been emphasized because of the immaturity of their biological systems. The main aim of this study was to assess the reproductive impact of BPA leached from commercially available plastic containers used or related to child nutrition, performing ecotoxicological tests using the biomonitoring species Daphnia magna. Acute and chronic tests, as well as single and multigenerational tests were done. Migration of BPA from several baby bottles and other plastic containers evaluated by GC-MS indicated that a broader range of foodstuff may be contaminated when packed in plastics. Ecotoxicological test results performed using defined concentrations of BPA were in agreement with literature, although a precocious maturity of daphnids was detected at 3.0 mg/L. Curiously, an increased reproductive output (neonates per female) was observed when daphnids were bred in the polycarbonate (PC) containers (145.1±4.3 % to 264.7±3.8 %), both in single as in multigenerational tests, in comparison with the negative control group (100.3±1.6 %). A strong correlated dose-dependent ecotoxicological effect was observed, providing evidence that BPA leached from plastic food packaging materials act as functional estrogen in vivo at very low concentrations. In contrast, neonate production by daphnids cultured in polypropylene and non-PC bottles was slightly but not significantly enhanced (92.5±2.0 % to 118.8±1.8 %). Multigenerational tests also revealed magnification of the adverse effects, not only on fecundity but also on mortality, which represents a worrying trend for organisms that are chronically exposed to xenoestrogens for many generations. Two plausible explanations for the observed results could be given: a non-monotonic dose–response relationship or a mixture toxicity effect.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Da necessidade de criação de habitações que se adaptem ao constante dinamismo do ser humano, surgiu a ideia da concepção de um edifício evolutivo com base na construção modular. A construção modular poderá ser entendida como sendo a principal resposta ao combate da construção de estruturas físicas e imóveis, com características inalteráveis ao longo do tempo. Com este trabalho idealizou-se uma habitação evolutiva, baseado nos conceitos da Coordenação Modular, identificando-se as suas especificações, exigências de desempenho e características funcionais. Foi considerada como medida modular base 0,10m. Os módulos foram pensados com o intuito de que o seu desempenho prático seja satisfatório. A sua base estrutural foi executada a partir do rearranjo de contentores marítimos. Previu-se ainda, o uso de coberturas verdes por serem uma solução comprovada de minorar notoriamente o efeito pernicioso que a construção tem sobre o meio ambiente, ao mesmo tempo que apresentam vantagens térmicas e acústicas. A questão do incentivo do uso da pré-fabricação em Portugal a uma maior escala, não poderia ser descurada. A apresentação de eventuais desenvolvimentos futuros é também relevante, dada a importância que é inerente ao âmbito da industrialização da construção. Do estudo realizado ficaram ainda, bem patentes, os benefícios da racionalização e da industrialização, tanto em termos económicos como em termos ambientais. É possível executar um projecto com níveis de perdas mais baixos e com índices de qualidade superiores a um menor preço.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Trabalho Final de Mestrado para obtenção do grau de Mestre em Engenharia Mecânica Manutenção e Produção

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The container loading problem (CLP) is a combinatorial optimization problem for the spatial arrangement of cargo inside containers so as to maximize the usage of space. The algorithms for this problem are of limited practical applicability if real-world constraints are not considered, one of the most important of which is deemed to be stability. This paper addresses static stability, as opposed to dynamic stability, looking at the stability of the cargo during container loading. This paper proposes two algorithms. The first is a static stability algorithm based on static mechanical equilibrium conditions that can be used as a stability evaluation function embedded in CLP algorithms (e.g. constructive heuristics, metaheuristics). The second proposed algorithm is a physical packing sequence algorithm that, given a container loading arrangement, generates the actual sequence by which each box is placed inside the container, considering static stability and loading operation efficiency constraints.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

A presente dissertação foi realizada em colaboração com o grupo empresarial Monteiro, Ribas, tendo como principal objectivo a realização de uma auditoria à gestão dos resíduos industriais produzidos pelas suas fábricas localizadas na Estrada da Circunvalação, no Porto. Para cumprir este objectivo, inicialmente foi efectuado um levantamento das obrigações legais relativas aos resíduos e foram procuradas práticas aconselhadas para a gestão interna. Para cada uma das fábricas, verificaram-se, quais os resíduos produzidos e analisaram-se os seus percursos, considerando as suas origens, os locais e modos de acondicionamento na origem, os modos de transporte interno, os locais e modos de armazenagem preliminar, e ainda, as quantidades produzidas, os transportadores, os operadores finais e as operações finais de gestão, sendo que estas quatro últimas informações são relativas ao ano 2013. De seguida procedeu-se à realização da auditoria nas diferentes unidades, verificando o cumprimento dos requisitos legais e das boas práticas em matéria de gestão de resíduos. As principais não conformidades detectadas, comuns às várias unidades fabris foram a inexistência de local/recipiente definido para acondicionamento de alguns resíduos, a falta ou insuficiente identificação de recipientes/zonas de acondicionamento, a inexistência de bacias de retenção para resíduos líquidos perigosos, o facto de no transporte interno apenas os resíduos perigosos serem cobertos e, os resíduos líquidos perigosos não serem transportados sobre bacias de retenção móveis nem com o material necessário para absorver derrames. Para cada resíduo e para cada unidade industrial foram propostas medidas correctivas e/ou de melhoria, quando aplicável. Relativamente à armazenagem preliminar, a principal inconformidade detectada foi o facto de todos os parques (quatro) possuírem resíduos perigosos no momento das auditorias, o que não é adequado. Foram propostas medidas correctivas e/ou de melhoria para cada parque. Como proposta global, tendo em conta factores económicos e de segurança, sugeriu-se que apenas o parque de resíduos perigosos possa armazenar este tipo de resíduos, pelo que os procedimentos de transporte interno devem ser melhorados, fazendo com que estes resíduos sejam transportados directamente para o parque de resíduos perigosos. Desta forma dois dos parques devem sofrer algumas remodelações, nomeadamente serem cobertos e fechados, ainda que não totalmente, e o parque de resíduos perigosos deve ser fechado, mantendo aberturas para ventilação, deve ser equipado com kit´s de contenção de derrames, fichas de segurança, procedimentos a realizar em caso de emergência, e ainda, devido ao facto do sistema de contenção de derrames ser pequeno face ao total de armazenamento, aconselha-se o uso de bacias de retenção para alguns dos recipientes de resíduos líquidos perigosos. Ao longo deste processo e em consequência da realização da auditoria, algumas situações consideradas não conformes foram sendo corrigidas. Também foram preparadas instruções de trabalho adequadas que serão posteriormente disponibilizadas. Foi ainda elaborada uma metodologia de avaliação de processos como base de trabalho para redução dos resíduos gerados. A etapa escolhida para a aplicação da mesma foi uma etapa auxiliar do processo produtivo da Monteiro, Ribas - Revestimentos, S.A - a limpeza de cubas com solventes, por forma a tentar minimizar os resíduos de solventes produzidos nesta operação. Uma vez que a fábrica já realiza a operação tendo em consideração medidas de prevenção e reutilização, a reciclagem é neste momento a única forma de tentar minimizar os resíduos de solventes. Foram então estudadas duas opções, nomeadamente a aquisição de um equipamento de regeneração de solventes e a contratação de uma operadora que proceda à regeneração dos resíduos de solventes e faça o retorno do solvente regenerado. A primeira opção poderá permitir uma redução de cerca de 95% na produção de resíduos de solventes e na aquisição de solvente puro, estimando-se uma poupança anual de cerca de **** €, com um período de recuperação do capital de cerca de 16 meses e a segunda pode conduzir a uma redução significativa na aquisição de solvente puro, cerca de 65%, e a uma poupança anual de cerca de **** €.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Dissertação de Mestrado em Gestão Integrada da Qualidade Ambiente e Segurança

Relevância:

10.00% 10.00%

Publicador:

Resumo:

For efficient planning of waste collection routing, large municipalities may be partitioned into convenient sectors. The real case under consideration is the municipality of Monção, in Portugal. Waste collection involves more than 1600 containers over an area of 220 km2 and a population of around 20,000 inhabitants. This is mostly a rural area where the population is distributed in small villages around the 33 boroughs centres (freguesia) that constitute the municipality. In most freguesias, waste collection is usually conducted 3 times a week. However, there are situations in which the same collection is done every day. The case reveals some general and specific characteristics which are not rare, but are not widely addressed in the literature. Furthermore, new methods and models to deal with sectorization and routing are introduced, which can be extended to other applications. Sectorization and routing are tackled following a three-phase approach. The first phase, which is the main concern of the presentation, introduces a new method for sectorization inspired by Electromagnetism and Coulomb’s Law. The matter is not only about territorial division, but also the frequency of waste collection, which is a critical issue in these types of applications. Special characteristics related to the number and type of deposition points were also a motivation for this work. The second phase addresses the routing problems in each sector: new Mixed Capacitated Arc Routing with Limited Multi-Landfills models will be presented. The last phase integrates Sectoring and Routing. Computational results confirm the effectiveness of the entire novel approach.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

RESUMO - A literatura disponível revela que a maioria dos erros relacionados com os exames anatomopatológicos ocorre na fase pré-analítica. Existem alguns estudos que quantificam e caracterizam estes erros mas, não foram encontrados artigos publicados sobre o tema em hospitais portugueses. Foi objetivo deste estudo determinar qual a prevalência e características dos erros pré-analíticos em amostras anatomopatológicas e as suas consequências para a segurança do doente. Analisaram-se 10574 casos de exames anatomopatológicos, de cinco hospitais da região de Lisboa e Vale do Tejo. Os serviços de anatomia patológica registaram e caracterizaram, durante vinte dias, erros detetados nas amostras anatomopatológicas com origem nos serviços requisitantes. Posteriormente os hospitais foram caracterizados quanto aos procedimentos relativos à fase pré-analítica. A prevalência de erros aferida foi de 3,1% (n=330), com um intervalo de confiança a 95% compreendido entre os valores 2,8% e 3,5%. Para além destes resultados destacam-se os seguintes pontos: i. As amostras histológicas têm 4,1% de prevalentes e as de citologia 0,9%; ii. Foram registados erros em 2,6% das requisições e em 1,5% dos contentores com as amostras; iii. A aceitação dos casos com erro é a ação mais frequente (66,9%), seguida pela devolução (24,4%) e retenção (8,7%); iv. Os hospitais com sistemas de notificação de erros e normas escritas para aceitação de amostras têm menor prevalência de erros; v. O impacte dos erros detetados na segurança dos doentes é difícil de determinar, sendo que os mais críticos relacionam-se com amostras devolvidas a fresco, meio de colheita inadequado ou com amostras danificadas. Este estudo permitiu determinar a prevalência e caracterizar os erros pré-analíticos envolvendo amostras anatomopatológicas em hospitais portugueses. Reflete a dimensão atual do problema e efetua recomendações para a sua mitigação. A prevalência de erros encontrada é inferior às publicadas em estudos semelhantes.