725 resultados para Contact Tracing,Asynchronous Contact Tracing,COVID-19
Resumo:
Rodents are the most frequently used animals in surgical experimentation. It is estimated that guinea pigs in particular are the third most commonly used species in this context. To disinfect guinea pigs’ skin, either alcohol or surgical iodine are most often used. In the context of an animal research project, a Nissen operation was performed in an adult male guinea pig. Because of accidental contamination of the operative field, a 10% povidone-iodine cutaneous solution was applied to the serosa of the anterior wall of the stomach and to the gastric fundus. The guinea pig died 12 hours after surgery due to an acute necrotizing hemorrhagic gastritis. Although there have been a few reports of povidone-iodine toxicity in the guinea pig, as far as the authors could determine, this is the first time that such a serious abdominal complication is reported. The authors believe that the possibility of a similar event should be taken into consideration when planning, executing and interpreting experiments in the guinea pig.
Resumo:
The occurrence of leprosy has decreased in the world but the perspective of its elimination has been questioned. A proposed control measure is the use of post-exposure chemoprophylaxis (PEP) among contacts, but there are still questions about its operational aspects. In this text we discuss the evidence available in literature, explain some concepts in epidemiology commonly used in the research on this topic, analyze the appropriateness of implementing PEP in the context of Brazil, and answer a set of key questions. We argue some points: (1) the number of contacts that need to receive PEP in order to prevent one additional case of disease is not easy to be generalized from the studies; (2) areas covered by the family health program are the priority settings where PEP could be implemented; (3) there is no need for a second dose; (4) risk for drug resistance seems to be very small; (5) the usefulness of a serological test to identify a higher risk group of individuals among contacts is questionable. Given that, we recommend that, if it is decided to start PEP in Brazil, it should start on a small scale and, as new evidence can be generated in terms of feasibility, sustainability and impact, it could move up a scale, or not, for a wider intervention.
Resumo:
A Work Project, presented as part of the requirements for the Award of a Masters Degree in Management from the NOVA – School of Business and Economics
Resumo:
Field lab: Consulting lab
Resumo:
Venomous animals are those that, by means of a hunting and defense mechanism, are able to inject their prey with a toxic substance produced in their bodies, directly from specialized glands (e.g., tooth, sting, spur) through which the poison passes. Millipedes are poisonous animals; they can be harmful to humans, and their effects usually manifest as erythematous, purpuric, and cyanotic lesions; local pain; and paresthesia. Here, we report a case of skin contact with a millipede for 6h resulting in skin lesions similar to blue toe syndrome.
Resumo:
INTRODUCTION : The tuberculin test is a diagnostic method for detecting latent tuberculosis (TB) infection, especially among disease contact cases. The objective of this study was to analyze the prevalence and evolution of Mycobacterium tuberculosis infection among TB contact cases. METHODS : A retrospective cohort study was performed in a reference center for TB. The study population consisted of 2,425 patients who underwent a tuberculin test from 2003 to 2010 and whose results indicated contact with individuals with TB. The data were collected from the registry book of the tuberculin tests, patient files and the Information System Records of Notification Grievance. To verify the evolution of TB, case records through September 2014 were consulted. Data were analyzed using the Statistical Package for the Social Sciences (SPSS). In all hypothesis tests, a significance level of 0.05 was used. RESULTS : From the studied sample, 435 (17.9%) contacts did not return for reading. Among the 1,990 contacts that completed the test, the prevalence of latent TB infection was 35.4%. Of these positive cases, 50.6% were referred to treatment; the dropout rate was 42.5%. Among all of the contacts, the TB prevalence was 1.8%, from which 13.2% abandoned treatment. CONCLUSIONS : The collected data indicate the need for more effective public policies to improve TB control, including administering tests that do not require a return visit for reading, enhancing contact tracing and encouraging actions that reinforce full treatment adherence.
Resumo:
This project aims to provide feasible solutions to improve customer´s Help Area at Continente Online. The goal is to increase satisfaction and loyalty by reducing the main causes that lead customers to appeal to Call Center or abandon the website. The pursued solution is the implementation of Web Self-Service and the vision taken is focused not only on providing customers basic help tools but also innovate with international best practices to sustain Sonae MC´s present and future market leader position. Customer´s feedback, costs and impact are taken in consideration to find the best fit for the company.
Resumo:
This study aimed to understand employees’ reactions to organizational politics in Contact Centers. Drawing from a sample of 187 supervisor-employee dyads, we studied the relationship between employees’ perceptions of organizational politics and supervisor-rated task performance and deviance, and mediation effects by authenticity at work and affective commitment. Results indicate that workers tend to react to workplace politics with deviant behavior and worse task performance. We found that the relationship between perceived politics and task performance was mediated by authenticity. The relationship between perceived politics and supervisor-rated deviance was mediated by affective commitment to the organization. Implications for management are discussed.
Resumo:
Dissertação de mestrado em Bioinformática
Resumo:
Purpose: To evaluate changes in anterior corneal topography and higher-order aberrations (HOA) after 14-days of rigid gas-permeable (RGP) contact lens (CL) wear in keratoconus subjects comparing two different fitting approaches. Methods: Thirty-one keratoconus subjects (50 eyes) without previous history of CL wear were recruited for the study. Subjects were randomly fitted to either an apical-touch or three-pointtouch fitting approach. The lens’ back optic zone radius (BOZR) was 0.4 mm and 0.1 mm flatter than the first definite apical clearance lens, respectively. Differences between the baseline and post-CL wear for steepest, flattest and average corneal power (ACP) readings, central corneal astigmatism (CCA), maximum tangential curvature (KTag), anterior corneal surface asphericity, anterior corneal surface HOA and thinnest corneal thickness measured with Pentacam were compared. Results: A statistically significant flattening was found over time on the flattest and steepest simulated keratometry and ACP in apical-touch group (all p < 0.01). A statistically significant reduction in KTag was found in both groups after contact lens wear (all p < 0.05). Significant reduction was found over time in CCA (p = 0.001) and anterior corneal asphericity in both groups (p < 0.001). Thickness at the thinnest corneal point increased significantly after CL wear (p < 0.0001). Coma-like and total HOA root mean square (RMS) error were significantly reduced following CL wearing in both fitting approaches (all p < 0.05). Conclusion: Short-term rigid gas-permeable CL wear flattens the anterior cornea, increases the thinnest corneal thickness and reduces anterior surface HOA in keratoconus subjects. Apicaltouch was associated with greater corneal flattening in comparison to three-point-touch lens wear.
Resumo:
Purpose. The purpose of this work was to evaluate the potential of a novel custom-designed rigid gas permeable (RGP) contact lens to modify the relative peripheral refractive error in a sample of myopic patients. Methods. Fifty-two right eyes of 52 myopic patients (mean [TSD] age, 21 [T2] years) with spherical refractive errors ranging from j0.75 to j8.00 diopters (D) and refractive astigmatism of 1.00 D or less were fitted with a novel experimental RGP (ExpRGP) lens designed to create myopic defocus in the peripheral retina. A standard RGP (StdRGP) lens was used as a control in the same eye. The relative peripheral refractive error was measured without the lens and with each of two lenses (StdRGP and ExpRGP) using an open-field autorefractometer from 30 degrees nasal to 30 degrees temporal, in 5-degree steps. The effectiveness of the lens design was evaluated as the amount of relative peripheral refractive error difference induced by the ExpRGP compared with no lens and with StdRGP conditions at 30 degrees in the nasal and temporal (averaged) peripheral visual fields. Results. Experimental RGP lens induced a significant change in relative peripheral refractive error compared with the nolens condition (baseline), beyond the 10 degrees of eccentricity to the nasal and temporal side of the visual field (p G 0.05). The maximum effect was achieved at 30 degrees. Wearing the ExpRGP lens, 60% of the eyes had peripheral myopia exceeding j1.00 D, whereas none of the eyes presented with this feature at baseline. There was no significant correlation (r = 0.04; p = 0.756) between the degree of myopia induced at 30 degrees of eccentricity of the visual field with the ExpRGP lens and the baseline refractive error. Conclusions. Custom-designed RGP contact lenses can generate a significant degree of relative peripheral myopia in myopic patients regardless of their baselin spherical equivalent refractive error.
Resumo:
Purpose: To study the relationship among the variables intensity ofthe end-of-day (EOD) dryness, corneal sensitivity and blink rate in soft contact lens (CL) wearers. Methods: Thirty-eight soft CL wearers (25 women and 13 men; mean age 27.1 ± 7.2 years) were enrolled. EOD dryness was assessed using a scale of 0–5 (0, none to 5, very intense). Mechanical and thermal (heat and cold) sensitivity were measured using a Belmonte’s gas esthesiometer. The blink rate was recorded using a video camera while subjects were wearing a hydrogel CL and watching a film for 90 min in a controlled environmental chamber. Results: A significant inverse correlation was found between EOD dryness and mechanical sensitivity (r: −0.39; p = 0.02); however, there were no significant correlations between EOD dryness and thermal sensitivity. A significant (r: 0.56; p < 0.001) correlation also was observed between EOD dryness and blink rate, but no correlations were found between blink rate and mechanical or thermal sensitivity. Conclusions: CL wearers with higher corneal sensitivity to mechanical stimulation reported more EOD dryness with habitual CL wear. Moreover, subjects reporting more EOD dryness had an increased blink rates during wear of a standard CL type. The increased blink rate could act to improve the ocular surface environment and relieve symptoms
Resumo:
Purpose: Higher myopic refractive errors are associated with serious ocular complications that can put visual function at risk. There is respective interest in slowing and if possible stopping myopia progression before it reaches a level associated with increased risk of secondary pathology. The purpose of this report was to review our understanding of the rationale(s) and success of contact lenses (CLs) used to reduce myopia progression. Methods: A review commenced by searching the PubMed database. The inclusion criteria stipulated publications of clinical trials evaluating the efficacy of CLs in regulating myopia progression based on the primary endpoint of changes in axial length measurements and published in peerreviewed journals. Other publications from conference proceedings or patents were exceptionally considered when no peer-review articles were available. Results: The mechanisms that presently support myopia regulation with CLs are based on the change of relative peripheral defocus and changing the foveal image quality signal to potentially interfere with the accommodative system. Ten clinical trials addressing myopia regulation with CLs were reviewed, including corneal refractive therapy (orthokeratology), peripheral gradient lenses, and bifocal (dual-focus) and multifocal lenses. Conclusions: CLs were reported to be well accepted, consistent, and safe methods to address myopia regulation in children. Corneal refractive therapy (orthokeratology) is so far the method with the largest demonstrated efficacy in myopia regulation across different ethnic groups. However, factors such as patient convenience, the degree of initial myopia, and non-CL treatments may also be considered. The combination of different strategies (i.e., central defocus, peripheral defocus, spectral filters, pharmaceutical delivery, and active lens-borne illumination) in a single device will present further testable hypotheses exploring how different mechanisms can reinforce or compete with each other to improve or reduce myopia regulation with CLs.
Resumo:
PURPOSE: The aim of this work was to study the central and peripheral thickness of several contact lenses (CL) with different powers and analyze how thickness variation affects CL oxygen transmissibility. METHODS: Four daily disposable and five monthly or biweekly CL were studied. The powers of each CL were: the maximum negative power of each brand; -6.00 D; -3.00 D; zero power (-0.25 D or -0.50 D), +3.00 D and +6.00 D. Central and peripheral thicknesses were measured with an electronic thickness gauge. Each lens was measured five times (central and 3mm paracentral) and the mean value was considered. Using the values of oxygen permeability given by the manufacturers and the measured thicknesses, the variation of oxygen transmissibility with lens power was determined. RESULTS: For monthly or biweekly lenses, central thickness changed between 0.061 ± 0.002 mm and 0.243 ± 0.002 mm, and peripheral thickness varied between 0.084 ± 0.002 mm and 0.231 ± 0.015 mm. Daily disposable lenses showed central values ranging between 0.056 ± 0.0016 mm and 0.205 ± 0.002 mm and peripheral values between 0.108 ± 0.05 and 0.232 ± 0.011 mm. Oxygen transmissibility (in units) of monthly or biweekly CL ranged between 39.4 ± 0.3 and 246.0 ± 14.4 and for daily disposable lenses the values range between 9.5 ± 0.5 and 178.1 ± 5.1. CONCLUSIONS: The central and peripheral thicknesses change significantly when considering the CL power and this has a significant impact on the oxygen transmissibility. Eyecare practitioners must have this fact in account when high power plus or minus lenses are fitted or when continuous wear is considered.
Resumo:
PURPOSES: To determine the level of compliance and major non-compliant behaviors in contact lens (CL) wearing medical doctors (MDs) and to compare it with age matched CL wearing normal subjects with no medical background (NS). METHODS: Thirty-nine current CL wearing MDs, who were prescribed CLs in Nepal Eye Hospital, Kathmandu, Nepal, between 2007 and 2011, were interviewed on ten modifiable compliant behaviors regarding lens care and maintenance. The level of compliance and the rate of non-compliance for each behavior were determined and compared with NS. RESULTS: Level of compliance was good, average and poor in 35.9%, 48.7% and 15.4% of MDs, respectively. There was no significant difference in compliance between MDs and NS (p=0.209). Level of compliance was not associated with age, gender and duration of lens wear (p>0.05). Compliance rate varied according to different behaviors, achieving a good compliance level of 95% for hand hygiene, avoidance of water contact and not sleeping with lenses. There was poor compliance for topping up solution (53.8%) and lens case replacement (15.4%). CONCLUSION: About one third of MDs had a good level of compliance. Level of compliance and compliance rate of different behaviors were similar in MDs and NS. Periodic lens case replacement was the most neglected behavior in CL wearers for this region.