957 resultados para Color vision Evaluation tests


Relevância:

40.00% 40.00%

Publicador:

Resumo:

After vaccination with the live PF strain of Trypanosoma cruzi, 194 blood cultures were performed in 143 mice, 9 dogs, 5 Cebus monkeys and 7 human subjects. Some of these blood cultures were simultaneously done with xenodiagnosis, subinoculation in baby mice and/or culture of viscerae. The trypanosomes isolated from the few positive cases (6,1%) were incapable of infecting baby mice were considered as cases of immunotolerance. All the other tests were negative.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

High reflective paints (cool paints) are used on flat roofs to reduce heat gains from the incidence of solar radiation and thus improve the thermal comfort and energy efficiency of buildings, especially in summer periods. Given the application potential of these paints on vertical surfaces, a research study has been developed to evaluate the thermal performance of reflective paints on walls under real exposure conditions. Accordingly, different reflective paints have been applied as the final coating of an ETICS type solution, on the facades of a full scale experimental cell built at LNEC campus. For being applied in an ETICS system a paint has to fulfill several requirements, whether aesthetic or functional (such as the adhesion between the coating layers or the durability of the insulation), essential for its efficient performance. Since this construction coating system is subject to a prolonged sun exposure, various problems may arise, such as paint degradation or deterioration of the thermal insulation properties, particularly when dark colors are applied. To evaluate the thermal performance of the chosen paints, the method of non-destructive analysis by Infrared Thermography was used. Thermography allows knowing the temperature distribution of facades by measuring the radiation emitted by their surfaces. To complement the thermographic diagnosis, thermocouples were placed between the insulation and the paint system of the experimental cell. Additional laboratory tests allowed the characterization of the optical properties (reflectance and emittance) of the different reflective paints used in this study. The comparative analysis of the thermal performance of reflective and conventional paints revealed that the reflective paint allows a reduction of the facade surface temperature, reducing the risk of loss of insulating properties of the ETICS system and thus ensuring its longevity and functionality. The color of the paint used affects, naturally, the reflective ability of the surface and may have an important role in energy balance of the building. This paper also showed the potential of infrared thermography in the evaluation of the thermal performance of reflective paints.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Introduction Since the launch of the Global Programme to Eliminate Lymphatic Filariasis, more than 70% of the endemic countries have implemented mass drug administration (MDA) to interrupt disease transmission. The monitoring of filarial infection in sentinel populations, particularly schoolchildren, is recommended to assess the impact of MDA. A key issue is choosing the appropriate tools for these initial assessments (to define the best intervention) and for monitoring transmission. Methods This study compared the pre-MDA performance of five diagnostic methods, namely, thick film test, Knott's technique, filtration, Og4C3-ELISA, and the AD12-ICT card test, in schoolchildren from Brazil. Venous and capillary blood samples were collected between 11 pm and 1 am. The microfilarial loads were analyzed with a negative binomial regression, and the prevalence and associated 95% confidence intervals were estimated for all methods. The accuracies of the AD12-ICT card and Og4C3-ELISA tests were assessed against the combination of parasitological test results. Results A total of 805 schoolchildren were examined. The overall and stratified prevalence by age group and gender detected by Og4C3-ELISA and AD12-ICT were markedly higher than the prevalence estimated by the parasitological methods. The sensitivity of the AD12-ICT card and Og4C3-ELISA tests was approximately 100%, and the positive likelihood ratios were above 6. The specificity of the Og4C3-ELISA was higher than that of the AD12-ICT at different prevalence levels. Conclusions The ICT card test should be the recommended tool for monitoring school-age populations living in areas with ongoing or completed MDA.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

The passive haemagglutination (PHA) test, enzyme-linked immunosorbent assay (ELISA) and the dot enzyme-immunosorbent assay (DOT-ELISA) were used to detect the levels of IgG antibodies against the Fraction 1 (F1) antigen of Yersinia pestis in sera of plague-infected patients from Northeast Brazil. Twenty three selected PHA-positive sera of subjects with bacteriological confirmation of plague were also positive in the DOT-ELISA but only 19 were detected by the conventional ELISA technique. Another group of 186 serum samples from subjects diagnosed as plague-infected by clinical and epidemiological parameters, but PHA-negative, were screened with DOT-ELISA and 11 gave positive results. The specificity of the assays on the serological detection of plague was confirmed in inhibition tests using purified F1 antigen. These results suggest that DOT-ELISA can be an useful, simple and more sensitive alternative for the serodiagnosis of plague in Northeast Brazil.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Forensic scientists working in 12 state or private laboratories participated in collaborative tests to improve the reliability of the presentation of DNA data at trial. These tests were motivated in response to the growing criticism of the power of DNA evidence. The experts' conclusions in the tests are presented and discussed in the context of the Bayesian approach to interpretation. The use of a Bayesian approach and subjective probabilities in trace evaluation permits, in an easy and intuitive manner, the integration into the decision procedure of any revision of the measure of uncertainty in the light of new information. Such an integration is especially useful with forensic evidence. Furthermore, we believe that this probabilistic model is a useful tool (a) to assist scientists in the assessment of the value of scientific evidence, (b) to help jurists in the interpretation of judicial facts and (c) to clarify the respective roles of scientists and of members of the court. Respondents to the survey were reluctant to apply this methodology in the assessment of DNA evidence.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Specific IgG and IgM responses to soluble egg antigen (SEA) and keyhole limpet haemocyanin (KLH) were measured by ELISA in patients with acute and chronic schistosomiasis. The tests based upon IgM and IgG antibodies responses to KLH presented the best diagnostic discrimination, and can be used in conjunction with clinical and epidemiological data to the differential diagnosis of acute schistosomiasis.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

This study was conducted to compare among the most recent generation of five screening tests licensed in Argentina, in order to evaluate which of the tests has the best sensitivity for detection of antibodies against hepatitis C virus (HCV). The tests analyzed were: Detect-HCV™ (3.0) Biochem ImmunoSystems, Canada; Hepatitis C EIA Wiener Lab., Argentina; Equipar HCV Ab, Italy; Murex HCV 4.0, UK and Serodia-HCV particles agglutination test, Japan. The results obtained showed high discrepancy between the different kits used and show that some of the tests assessed have a low sensitivity for anti-HCV detection in both chronic infections and early seroconversion, and indicate that among the commercially available kits in Argentina, Murex HCV 4.0 (UK) and Serodia-HCV particles agglutination test (Japan) have the best sensitivity for HCV screening. Although the sensitivity of the assays is the first parameter to be considered for blood screening, more studies should be carried out to assess the specificity of such assays.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Un protocole de tests sur labyrinthe radial permettant d'évaluer la navigation spatial chez l'homme a été réalisé. Ces tests sur labyrinthe radial sont basés sur le protocole utilisé sur l'animal modèle de schizophrénie dans le CNP (Centre de neuroscience psychiatrique) de Lausanne. Les recherches actuelles du CNP ont montré un déficit dans les capacités d'orientation spatiale de ces animaux [13]. Ainsi notre méthodologie consistera à tester des sujets humains dans des tâches de labyrinthe afin d'étudier de la manière la plus équivalente les différents déficits observés dans la pathologie humaine et dans le rat modèle. Cette démarche est à la base d'une approche translationnelle qui combine recherches cliniques et expérimentales. Le travail expérimental a été mené sur deux dispositifs analogues. a) «radial au doigt», ensemble de petits canaux qui peuvent être explorés par le doigt, yeux ouverts ou fermés et dans lesquels des textures différentes tapissent chaque bras. b) «radial sur écran tactile», deux labyrinthes qui comparent deux types d'indice locale, couleurs différentes ou patrons noir-blanc. Dans les deux dispositifs a été prévu une série de tests permettant d'évaluer la mémorisation des indices utilisés en les supprimant temporairement où en les mettant en contradiction. La première perturbation a pour but de tester l'importance du référentiel locale par une rotation de 90° du labyrinthe. La permutation des bras lors d'un dernier essai permet d'induire une situation ou les informations ont été soit correctes spatialement mais incorrectes localement (texture) soit inversement. Ces perturbations des informations sensorielles qui sont fournies au sujet, permettent d'observer les systèmes de repérage et leur poids relatif dans la construction d'un système de référence durant la navigation spatiale. Les résultats du labyrinthe radial au doigt montrent que dans les conditions utilisant les informations visuelles les participants sont sensiblement plus performants. Il est apparu que les informations visuelles prédominent sur les informations proprioceptives et tactiles. Ainsi dans la condition intégrant informations visuospatiales, proprioceptives et tactiles, les sujets basent plus fortement leur navigation spatiale sur les indices visuelles soit locale soit spatiale. Dans cette condition une différence significative de stratégie entre hommes et femmes est apparue. Les hommes se basent majoritairement sur des indices spatiaux tandis que les femmes préfèrent les indices locaux. En présence d'informations tactiles et proprioceptives mais en absence de la vision, les participants utilisent les références spatiale et locale complémentairement sans avoir un système prédominant. Alors que si uniquement les informations proprioceptives sont présentes, les sujets utilisent un système de référence spatiale (globale). Le labyrinthe radial sur écran tactile indique une différence de système de référence selon l'indice local employé. Les couleurs, étant des forts indices locaux, vont favoriser un système de référence local. Au contraire les patrons noirs-blancs sont des indices visiblement très complexes et difficiles à mémoriser qui vont pousser les sujets à utiliser une stratégie de référence spatiale.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

BACKGROUND: While the assessment of analytical precision within medical laboratories has received much attention in scientific enquiry, the degree of as well as the sources causing variation between them remains incompletely understood. In this study, we quantified the variance components when performing coagulation tests with identical analytical platforms in different laboratories and computed intraclass correlations coefficients (ICC) for each coagulation test. METHODS: Data from eight laboratories measuring fibrinogen twice in twenty healthy subjects with one out of 3 different platforms and single measurements of prothrombin time (PT), and coagulation factors II, V, VII, VIII, IX, X, XI and XIII were analysed. By platform, the variance components of (i) the subjects, (ii) the laboratory and the technician and (iii) the total variance were obtained for fibrinogen as well as (i) and (iii) for the remaining factors using ANOVA. RESULTS: The variability for fibrinogen measurements within a laboratory ranged from 0.02 to 0.04, the variability between laboratories ranged from 0.006 to 0.097. The ICC for fibrinogen ranged from 0.37 to 0.66 and from 0.19 to 0.80 for PT between the platforms. For the remaining factors the ICC's ranged from 0.04 (FII) to 0.93 (FVIII). CONCLUSIONS: Variance components that could be attributed to technicians or laboratory procedures were substantial, led to disappointingly low intraclass correlation coefficients for several factors and were pronounced for some of the platforms. Our findings call for sustained efforts to raise the level of standardization of structures and procedures involved in the quantification of coagulation factors.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

The topic of this thesis is studying how lesions in retina caused by diabetic retinopathy can be detected from color fundus images by using machine vision methods. Methods for equalizing uneven illumination in fundus images, detecting regions of poor image quality due toinadequate illumination, and recognizing abnormal lesions were developed duringthe work. The developed methods exploit mainly the color information and simpleshape features to detect lesions. In addition, a graphical tool for collecting lesion data was developed. The tool was used by an ophthalmologist who marked lesions in the images to help method development and evaluation. The tool is a general purpose one, and thus it is possible to reuse the tool in similar projects.The developed methods were tested with a separate test set of 128 color fundus images. From test results it was calculated how accurately methods classify abnormal funduses as abnormal (sensitivity) and healthy funduses as normal (specificity). The sensitivity values were 92% for hemorrhages, 73% for red small dots (microaneurysms and small hemorrhages), and 77% for exudates (hard and soft exudates). The specificity values were 75% for hemorrhages, 70% for red small dots, and 50% for exudates. Thus, the developed methods detected hemorrhages accurately and microaneurysms and exudates moderately.