978 resultados para Chromatographic columns
Resumo:
The 2,4-dichlorophenoxyacetic acid (2,4-D) is one of the most applied herbicides around the world to control broad leave herbs in many crops: In this study, a method was developed for simultaneous extraction and determination of 2,4D and its major transformation product, i.e., the 2,4-dichlorophenol (2,4-DCP), in soil samples. The herbicide and its degradation product were extracted twice from soil samples, after acidification, by dichloromethane on ultrasound system for 1 h. Both extracts were combined and filtrated in qualitative filter paper and Celitee. The total extract was concentrated in rotatory evaporator, dried under N-2 and finally dissolved in 1 ml of methanol. High Performance Liquid Chromatography with UV detection at 230 nm was used for analysis. Recoveries were obtained from soil samples fortified at 0.1, 1.0, 2.0, 3.0 and 4.0 mg kg(-1) levels and the results varied from 85 to 111% (for 2,4-D) and from 95 to 98% (for 2,4-DCP). For both compounds, the limits of quantification were 0.1 mg kg(-1), which were the loss level at which the accuracy and the precision were studied. Nevertheless, the limits of detection, calculated by considering the blank standard deviation and the minimum concentration level, were 0.03 and 0.02 mg kg for 2,4-D and 2,4-DCP, respectively. This proposed method was applied to soil samples of eucalyptus crops, which was previously treated with the herbicide. Despite that, neither 2,4-D nor its degradation product were detected 30 days after the herbicide application. (C) 2003 Elsevier B.V. B.V. All rights reserved.
Resumo:
Hemoglobin variants originate mainly by simple amino acid substitutions, the result of nucleotide sequence changes. Recently, the number of known abnormal hemoglobins has increased due to improvement in analysis methodologies; however, many laboratories are not prepared to correctly identify mutants. Hb S is a very well-characterized hemoglobin variant that varies in prevalence in different regions of Brazil. However, there is a type of Hb that presents electrophoretic migration in alkaline pH similar to Hb S, named S-like Hb, which can be incorrectly diagnosed; therefore, its frequency is underestimated. We obtained reference ranges for Hb S by HPLC, and we examined the electrophoretic and chromatographic profiles of S-like Hb. Hb Hasharon, Hb D-Los Angeles, Hb Korle-Bu, Hb Lepore, Hb D-Iran, Hb G-like, Hb Queens, Hb Montgomery, and Hb Q-India were found. Cases of association between two beta chain mutants were also found. Electrophoresis in alkaline and acid pH was utilized to initially screen these Hb variants, and globin chain electrophoresis at both high and low pH was performed to identify the globin chain mutant. Chromatographic analysis permitted the identification of the hemoglobin variant and also facilitated the quantification of these variants. Therefore, an association of classical laboratory diagnostic methodologies is fundamental for the correct identification of suspect Hb variants. The S and S-like hemoglobin profiles determined in this study will help in the diagnosis of these variants in health care services.
Resumo:
A method has been developed for the determination of the cocaine levels in samples of hair, using a chromatographic column internal surface reverse phase (ISRP)-C-18, for direct injection of the extracts of hair, without purification or derivation of the sample. The method allows monitoring an individual stopped for using or making cocaine. This method allowed the determination of levels of cocaine concentration in 75% of the analyzed samples of chemical dependents' hair, with cocaine detected at levels of 0.37-16.85 mug g(-1). In the other analyzed samples (25%), the drug was not detected, because the corresponding individuals told us that they consumed cocaine infrequently and in small amounts. The detection
Resumo:
A rapid and simple gas chromatographic method for determinating cyprodinil, fludioxonil, pyrimethanil, and tebuconazole in grapes, must, and wine is described. An on-line microextraction method was used with a one-step extraction-partition procedure. Nitrogen-phosphorus and mass spectrometric detectors were used, because of their low sensitivity and high selectivity. Because of high selectivity of detector, no cleanup was necessary and the extract was concentrated 5 times. Recoveries from fortified grapes, must, and wine ranged from 93 to 110%. Limits of determination were 0.05 mg/kg for cyprodinil and pyrimethanil and 0.10 mg/kg for fludioxonil and tebuconazole.
Resumo:
A rapid and economical method is described for the determination of deltamethrin in wheat, rice, peanuts and corn. It is based on simultaneous extraction and clean-up on a column packed with alumina and silica gel using n-hexane-ethyl ether (8:2, v/v), followed by a derivatization step and gas-chromatographic analysis. Recoveries from fortified cereal and peanut samples were determined at four concentration levels and ranged from 73 to 109%. The detection limits were 0.01 to 0.03 mg/ kg. This method simplifies the traditional procedures in terms of sample size, solvent consumption and analysis time. © Springer-Verlag 1998.
Resumo:
2,2,7-trimethylguanosine (TMG) binding proteins from human cells were purified through TMG-affinity columns. TMG synthesis was improved and the TMG obtained was shown to be similar to the TMG in the 5' cap of the UsnRNAs. The eluates obtained with TMG-affinity chromatographies were very different from those isolated with m7G-affinity columns, thus suggesting that specific TMG- binding proteins were obtained. The fraction may be enriched with factors associated with import and/or hypermethylation of UsnRNPs.
Resumo:
The microbiological bioassay, the UV-spectrophotometry and the high performance liquid chromatography (HPLC) methods for assaying sparfloxacin in tablets were compared. The accuracy, repeatability, and precision of each method was assessed and precise. All methods were reliable within acceptable limits for antibiotic pharmaceutical preparations being accurate and precise. The microbiological bioassay and HPLC are more specific than UV-spectrophotometric analysis. However, the microbiological bioassay requires 20 h to get results, and HPLC is the most expensive analysis. The application of each method as a routine analysis should be investigated considering cost, simplicity, equipment, solvents, speed, and application to large or small workloads.
Resumo:
A rapid and efficient method is described for the determination of thiabendazole and imazalil residues in lemons (peel and pulp). The procedure is based on the extraction with an hexane:ethyl acetate mixture (1:1, v/v) and gas chromatographic analysis using thermionic specific detection (TSD). The possibility of matrix effect was also studied. Mean recoveries from 8 replicates of fortified samples ranged from 79% to 109%, with relative standard deviation values between 2.4% to 12.8%. The detection and quantification limits of the method were 0.2 mg kg-1 and 0.5 mg kg-1, respectively.
Resumo:
Studies of the hemoglobin pattern in Brazilian reptiles are important for determining ecological and phylogenetic relationships, but they are scarce. Peripheral blood samples were obtained from 7 males and 18 females of Rhinoclemmys punctularia. The hematological profile was based on the total hemoglobin and hematocrit values. The hemoglobin profile was obtained using electrophoretic procedures at different pH, isoelectric focusing, globin chain electrophoresis, and HPLC. The hematocrit (31 ± 2%) and total hemoglobin (7.5 ± 0.2 g/dL) values did not indicate gender variations. Alkaline pH electrophoresis of the total blood samples treated with 1% saponin demonstrated the presence of four well-defined hemoglobin fractions, one major component (fraction I), showing cathodic migration and three others faster than fraction I with anodic migration. When the samples were precipitated with chloroform, only two hemoglobin fractions were observed, similar to fractions I and III from the first procedure. Isoelectric focusing and HPLC showed the same pattern. With acid and neutral pH electrophoresis, two fractions with anodic migration were observed. The globin chain identification at alkaline pH showed two fractions, but four fractions were observed at acidic pH, suggesting that different polypeptide chains are involved in the hemoglobin molecule. The chromatographic separation of the total blood sample demonstrated that the major fraction comprised 81.9% and the minor 18.1%. The results obtained demonstrated a similarity between these hemoglobin components and those of some Chelidae reported in the literature for both land and aquatic animals, reflecting the adaptation to environmental conditions. ©FUNPEC-RP.
Resumo:
Chromatographic and electroanalytical methods were developed to detect and quantify Sudan II (SD-II) dye in fuel ethanol samples. Sudan II is reduced at +0.50 V vs. Ag/AgCl on a glassy carbon electrode using Britton-Robinson buffer (pH 4.0) and N,N-dimethylformamide (70:30, v/v) + sodium dioctyl sulfosuccinate surfactant as supporting electrolyte, due to the azo group. This is the basis for its determination by square-wave voltammetry (SWV). Using the optimized conditions, it is possible to get a linear calibration curve from 3.00×10-6 to 1.80×10-5 mol L-1 (r = 0.998) with limits of detection (LOD) and quantification (LOQ) of 2.05×10-6 and 6.76×10-6 mol L-1, respectively. In addition, the hydroxyl substituent in the SD-II dye is also oxidized at +0.85 V vs. Ag/AgCl, which was conveniently used for its determination by high-performance liquid chromatography coupled to electrochemical detection (HPLC-ED). Under the optimized condition, the SD-II dye was eluted and separated using a reversed-phase column (cyanopropyl, CN) using isocratic elution with the mobile phase containing acetonitrile and aqueous lithium chloride (5.00×10-4 mol L-1) at 70:30 (v/v) and a flow rate of 1.2 mL min-1. Linear calibration curves were obtained from 3.00×10-7 to 2.00×10-6 mol L-1 (r = 0.999) with LOD and LOQ of 3.10×10-8 and 1.05×10-7 mol L-1, respectively. Both methods were simple, fast and suitable to detect and quantify the dye in fuel ethanol samples at recovery values between 83.0 to 102% (SWV) and 88.0 to 112% (HPLC-ED) with satisfactory precision and accuracy.
Resumo:
Pós-graduação em Alimentos e Nutrição - FCFAR
Resumo:
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)
Resumo:
In this work the separation of multicomponent mixtures in counter-current columns with supercritical carbon dioxide has been investigated using a process design methodology. First the separation task must be defined, then phase equilibria experiments are carried out, and the data obtained are correlated with thermodynamic models or empirical functions. Mutual solubilities, Ki-values, and separation factors aij are determined. Based on this data possible operating conditions for further extraction experiments can be determined. Separation analysis using graphical methods are performed to optimize the process parameters. Hydrodynamic experiments are carried out to determine the flow capacity diagram. Extraction experiments in laboratory scale are planned and carried out in order to determine HETP values, to validate the simulation results, and to provide new materials for additional phase equilibria experiments, needed to determine the dependence of separation factors on concetration. Numerical simulation of the separation process and auxiliary systems is carried out to optimize the number of stages, solvent-to-feed ratio, product purity, yield, and energy consumption. Scale-up and cost analysis close the process design. The separation of palmitic acid and (oleic+linoleic) acids from PFAD-Palm Fatty Acids Distillates was used as a case study.
Resumo:
Hidrocarbonetos policíclicos aromáticos (HPAs) são compostos orgânicos originários de fontes naturais e antrópicas e, por apresentarem potencial carcinogênico e mutagênico, são considerados poluentes prioritários por agências ambientais. Desta forma, métodos analíticos para investigação de tais compostos que sejam rápidos e de baixo custo são de relevância considerável para o monitoramento ambiental. O presente trabalho teve como objetivos otimizar um método analítico para HPAs utilizando cromatografia líquida com detecção por arranjo de diodos (HPLC-DAD) e aplicar em testemunho sedimentar de região estuarina. Para otimização e avaliação do método, uma coluna sedimentar de 46 cm de comprimento foi coletada na foz do Rio Tucunduba (Belém, Pará) e seccionada em porções de 2 cm (subamostras). Após secagem, 30 g de cada porção foram extraídos com mistura de diclorometano em acetona (1:1) em ultrassom por 40 min. Os extratos obtidos foram centrifugados, purificados em sílica-gel, adaptação em funil necessária principalmente para reter partículas finas, e em seguida concentrados em rotaevaporador à vácuo e, por fim, filtrados com membrana de nylon 0,22 μm antes da injeção no HPLC. Amostras fortificadas com padrões analíticos de 16 HPAs e brancos também foram processados da mesma maneira. Um conjunto de parâmetros para validação do método foi investigado e observou-se: (1) boa linearidade: as curvas de calibração (analíticas) apresentaram coeficientes de correlação elevadas; (2) precisão adequada: obteve-se desvio padrão relativo dentro do aceitável, sendo o mínimo de 2,1% para acenaftileno e máximo de 19,7% para o fluoranteno; (3) limites de detecção baixos: entre 0,004 a 1,085 ng g g-1, viabilizando análises em concentrações reais in situ; (4) recuperação adequada para traços: sendo a mínima de 40,0% para o acenaftileno e máxima de 103,1% para o benzo(k)fluoranteno. As concentrações de HPAs totais variaram nas seções do testemunho sedimentar entre 60,77 - 783,3 ng g-1 de sedimento seco. O método otimizado mostrou-se vantajoso com relação aos tradicionais que utilizam extrator soxhlet e colunas de adsorventes para purificação de extratos por minimizar o tempo de extração e reduzir custos com uso de volumes menores de solventes para purificação do extrato. A limitação do método, porém, foi a coeluição do criseno e do benzo(a)antraceno e a sobreposição do fluoreno e acenafteno, além da quantificação benzo(g,h,i)perileno. Essa limitação provavelmente está associada à eficiência da coluna cromatográfica disponível para a análise, que é para aplicação geral. O método mostrou-se aplicável a amostras estuarinas complexas e ricas em silte e argila. Razões diagnósticas de HPAs parentais indicam fontes petrogênicas a profundidades de 24 – 26 cm, 28 – 30 cm; e fontes pirolíticas a profundidades de 6 – 8 cm, 10 – 12 cm e 14 – 16 cm respectivamente.