878 resultados para Cement-loaded, Kuntscher Nail, Revision, Hip Arthroplasty, Bone Loss


Relevância:

100.00% 100.00%

Publicador:

Resumo:

The complications of impaction bone grafting in revision hip replacement includes fracture of he femur and subsidence of the prosthesis. In this in vitro study we aimed to investigate whether the use of vibration, combined with a perforated tamp during the compaction of morsellised allograft would reduce peak loads and hoop strains in the femur as a surrogate marker of the risk of fracture and whether it would also improve graft compaction and prosthetic stability. We found that the peak loads and hoop strains transmitted to the femoral cortex during graft compaction and subsidence of the stem in subsequent mechanical testing were reduced. This innovative technique has the potential to reduce the risk of intra-operative fracture and to improve graft compaction and therefore prosthetic stability. © 2007 British Editorial Society of Bone and Joint Surgery.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

BACKGROUND: When fresh morselized graft is compacted, as in impaction bone-grafting for revision hip surgery, fat and marrow fluid is either exuded or trapped in the voids between particles. We hypothesized that the presence of incompressible fluid damps and resists compressive forces during impaction and prevents the graft particles from moving into a closer formation, thus reducing the graft strength. In addition, viscous fluid such as fat may act as an interparticle lubricant, thus reducing the interlocking of the particles. METHODS: We performed mechanical shear testing in the laboratory with use of fresh-frozen human femoral-head allografts that had been passed through different orthopaedic bone mills to produce graft of differing particle-size distributions (grading). RESULTS: After compaction of fresh graft, fat and marrow fluid continued to escape on application of normal loads. Washed graft, however, had little lubricating fluid and better contact between the particles, increasing the shear resistance. On mechanical testing, washed graft was significantly (p < 0.001) more resistant to shearing forces than fresh graft was. This feature was consistent for different bone mills that produced graft of different particle-size distributions and shear strengths. CONCLUSIONS: Removal of fat and marrow fluid from milled human allograft by washing the graft allows the production of stronger compacted graft that is more resistant to shear, which is the usual mode of failure. Further research into the optimum grading of particle sizes from bone mills is required.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Background: When fresh morselized graft is compacted, as in impaction bone-grafting for revision hip surgery, fat and marrow fluid is either exuded or trapped in the voids between particles. We hypothesized that the presence of incompressible fluid damps and resists compressive forces during impaction and prevents the graft particles from moving into a closer formation, thus reducing the graft strength. In addition, viscous fluid such as fat may act as an interparticle lubricant, thus reducing the interlocking of the particles. Methods: We performed mechanical shear testing in the laboratory with use of fresh-frozen human femoral-head allografts that had been passed through different orthopaedic bone mills to produce graft of differing particle-size distributions (grading). Results: After compaction of fresh graft, fat and marrow fluid continued to escape on application of normal loads. Washed graft, however, had little lubricating fluid and better contact between the particles, increasing the shear resistance. On mechanical testing, washed graft was significantly (p < 0.001) more resistant to shearing forces than fresh graft was. This feature was consistent for different bone mills that produced graft of different particle-size distributions and shear strengths. Conclusions: Removal of fat and marrow fluid from milled human allograft by washing the graft allows the production of stronger compacted graft that is more resistant to shear, which is the usual mode of failure. Further research into the optimum grading of particle sizes from bone mills is required. Clinical Relevance: Understanding the mechanical properties of milled human allograft is important when impaction grafting is used for mechanical support. A simple means of improving the mechanical strength of graft produced by currently available bone mills, including an intraoperative washing technique, is described.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Reliable prediction of long-term medical device performance using computer simulation requires consideration of variability in surgical procedure, as well as patient-specific factors. However, even deterministic simulation of long-term failure processes for such devices is time and resource consuming so that including variability can lead to excessive time to achieve useful predictions. This study investigates the use of an accelerated probabilistic framework for predicting the likely performance envelope of a device and applies it to femoral prosthesis loosening in cemented hip arthroplasty.
A creep and fatigue damage failure model for bone cement, in conjunction with an interfacial fatigue model for the implant–cement interface, was used to simulate loosening of a prosthesis within a cement mantle. A deterministic set of trial simulations was used to account for variability of a set of surgical and patient factors, and a response surface method was used to perform and accelerate a Monte Carlo simulation to achieve an estimate of the likely range of prosthesis loosening. The proposed framework was used to conceptually investigate the influence of prosthesis selection and surgical placement on prosthesis migration.
Results demonstrate that the response surface method is capable of dramatically reducing the time to achieve convergence in mean and variance of predicted response variables. A critical requirement for realistic predictions is the size and quality of the initial training dataset used to generate the response surface and further work is required to determine the recommendations for a minimum number of initial trials. Results of this conceptual application predicted that loosening was sensitive to the implant size and femoral width. Furthermore, different rankings of implant performance were predicted when only individual simulations (e.g. an average condition) were used to rank implants, compared with when stochastic simulations were used. In conclusion, the proposed framework provides a viable approach to predicting realistic ranges of loosening behaviour for orthopaedic implants in reduced timeframes compared with conventional Monte Carlo simulations.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Introducción Los Grupos Relacionados de Diagnóstico (GRD) se han usado para determinar la calidad de la atención en varios sistemas de salud. Esto ha llevado a que se obtengan resultados en el mejoramiento continuo de la atención y del cuidado. El objetivo de este estudio es determinar desenlaces clínicos de los pacientes a quienes se les había realizado reemplazo de articulares según la complejidad clínica definida mediante GRD. Métodos Se realizó un estudio longitudinal descriptivo en el cual se incluyeron todos los pacientes que tuvieron cirugía de reemplazo total de hombro, cadera y rodilla entre 2012 y 2014. Se realizó la estratificación de los pacientes de acuerdo a tres niveles de complejidad dados por el sistema de GRD y se determinaron las proporciones de pacientes para las variables de estancia hospitalaria, enfermedad trombo-embólica, cardiovascular e infección del sitio operatorio. Resultados Se realizaron en total 886 reemplazos articulares de los cuales 40 (4.5%) presentaron complicaciones. Los eventos más frecuentes fueron las complicaciones coronarias, con una presencia de 2.4%. El GRD1, sin complicaciones ni comorbilidades, fue el que presentó mayor número de eventos. La estancia hospitalaria fue de 3.8 a 9.3 días para todos los reemplazos. Conclusiones Contrario a lo planteado en la hipótesis de estudio, se encontró que el primer GRD presentó el mayor número de complicaciones, lo que puede estar relacionado con el tamaño del grupo. Es necesario realizar nuevas investigaciones que soporten el uso de los GRD como herramienta para evaluar desenlaces clínicos.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Las fracturas intertrocantericas son una importante causa de la morbimortalidad en los adultos mayores. Requieren la mayoria manejo quirurgico. No se ha logrado definir si es mejor el tratamiento con osteosintesis o artoplastia de cadera. Por esta razon decidimos realizar un estudio identificando los resultados en cada uno de los tratamientos con poblacion colombiana en el Hospital Universitario Mayor Mederi. Metodos: Estudio de serie de casos. Se analizó una cohorte retrospectiva de pacientes mayores de 59 años con fractura intertrocantérica en el Hospital Universitario Mayor Méderi. Resultados: Se reportaron un total de 179 pacientes con diagnóstico de fractura intertrocantérica. De los cuales se realizaron 100 osteosíntesis , 20 reemplazos totales de cadera y 59 hemiartroplastias. La mortalidad fueron 11 pacientes que corresponde al 6.1%, 3 fueron hombres y 8 mujeres, en cuanto al procedimiento realizado a 7 pacientes se les realizo osteosíntesis y a los 4 restantes se les realizo hemiartroplastia. En total 7 infecciones las cuales se presentaron respectivamente en 6 osteosíntesis y 1 hemiartroplastia. Discusión: La mortalidad fue mayor en la osteosíntesis con 7 pacientes que equivale al 63,6 % de la mortalidad total del estudio. Los porcentajes de infección postoperatoria fueron mayores en la osteosíntesis , encontrándose que del total de pacientes intervenidos 3,9% se infectaron y de estos el 85,7 % corresponden a osteosíntesis versus 14,3% de hemiartroplastia. El sangrado postoperatorio fue mayor a 500 cc en un 39% de las osteosíntesis y en un 44% en las hemiartroplastias. Conclusión: el tratamiento de las fracturas intertrocantéricas tuvo menor mortalidad y menor porcentaje de infección cuando los pacientes fueron tratados con hemiartroplastia y reemplazo total de cadera.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

O presente estudo é uma coorte não concorrente em 63 pacientes (66 quadris) submetidos à revisão de artroplastia total de quadril (RATQ), com enxerto ósseo liofilizado moído e impactado. Foi realizado no Serviço de Ortopedia e Traumatologia do Hospital de Clínicas de Porto Alegre (HCPA), no período de maio de 1997 a setembro de 2003. O objetivo do estudo foi comparar clínica, radiográfica e cintilograficamente a capacidade de osteointegração dos enxertos ósseos liofilizados humano e bovino impactados em RATQs cimentadas e não-cimentadas. Os pacientes foram divididos em dois grupos: o Grupo 1 (n=35) foi composto pelos que receberam enxerto ósseo liofilizado de origem humana e o Grupo 2 (n=31) por aqueles que receberam enxerto de origem bovina. O tempo médio de seguimento foi de 33 meses. Os enxertos ósseos purificados e liofilizados foram produzidos pelo Banco de Tecidos do HCPA. A análise clínica baseou-se no escore de Merle, d’Aubigné e Postel; a radiográfica, nos critérios de radioluscência, densidade, formação de trabeculado ósseo, migração dos componentes e floculação, formulando-se um escore radiográfico de osteointegração (EROI). Foram escolhidos, aleatoriamente, como forma complementar de análise por imagem, 35 (53%) pacientes assintomáticos para realizarem cintilografia óssea com Tecnécio, sendo 17 (48,5%) do Grupo 1 e 18 (51,5%) do Grupo 2. Não foram encontradas diferenças clínicas, radiográficas ou cintilográficas relevantes entre os grupos, obtendo-se em torno de 85% de integração do enxerto, tanto no componente acetabular quanto femoral. Estes resultados são comparáveis aos relatados na literatura com o uso de enxerto alogênico congelado e confirmam a adequacidade do uso de enxertos liofilizados de origem bovina e humana em RATQ.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Objectives: The aim of the present study was to evaluate histometric changes around dental implants inserted at different levels in relation to the crestal bone, under different loading conditions.Material and methods: Thirty-six implants were inserted in the edentulous mandible of six mongrel dogs. Each implant was assigned to an experimental group according to the distance from the top of the implant to the crestal bone: Bone Level (at the crestal bone level), Minus 1 (1 mm below the crestal bone) or Minus 2 group (2 mm below the crestal bone). Each hemimandible was submitted to a loading protocol: conventional or immediate restoration. After 90 days, the animals were killed. Specimens were processed, and measurements were performed concerning the length of soft and hard peri-implant tissues. Data were analyzed using ANOVA and Student's t test (alpha=5%).Results: Among conventionally restored sites, the distance from the most coronal position of soft tissue margin (PSTM) and first bone-implant contact (fBIC) was greater for Minus 2 than for Bone Level and Minus 1 sites (P=0.03), but significant differences were not observed among immediately restored sites. Differences among groups were not observed concerning the PSTM, and the distance from the implant-abutment junction to fBIC. Greater amounts of lateral bone loss were observed for conventionally than for immediately restored sites (P=0.006).Conclusions: These findings suggest that the apical positioning of the top of the implant may not jeopardize the position of soft peri-implant tissues, and that immediate restoration can be beneficial to minimize lateral bone loss. Further studies are suggested to evaluate the clinical significance of these results in longer healing periods.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

A minimal marginal bone loss around implants during early healing has been considered acceptable. However, the preservation of the marginal bone is related to soft tissue stability and esthetics. Implant designs and surfaces were evaluated to determine their impact on the behavior of the crestal bone. The purpose of this study is to evaluate histologic marginal bone level changes around early loaded, chemically modified, sandblasted acid-etched-surfaced implants with a machined collar (MC) or no MC (NMC).

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The aims of the study were (1) to determine the cumulative two to twenty-year survivorship of the hip after open reduction and internal fixation of displaced acetabular fractures, (2) to identify factors predicting conversion to total hip arthroplasty or hip arthrodesis, and (3) to create a predictive model that calculates an individual's probability of early need for total hip arthroplasty or hip arthrodesis.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

BACKGROUND: One way to evaluate various implant restorations is to measure the amount of bone change that occurs at the crestal bone. The objective of this study was to histologically evaluate the alveolar bone change around a bone-level, non-matching implant-abutment diameter configuration that incorporated a horizontal offset and a Morse taper internal connection. METHODS: The study design included extraction of all mandibular premolars and first molars in five canines. After 3 months, 12 dental implants were placed at three levels in each dog: even with the alveolar crest, 1 mm above the alveolar crest, and 1 mm below the alveolar crest. The implants were submerged on one side of the mandible. On the other side, healing abutments were exposed to the oral cavity (non-submerged). Gold crowns were attached 2 months after implant placement. The dogs were sacrificed 6 months postloading, and specimens were processed for histologic and histometric analyses. RESULTS: Evaluation of the specimens indicated that the marginal bone remained near the top of the implants under submerged and non-submerged conditions. The amount of bone change for submerged implants placed even with, 1 mm below, and 1 mm above the alveolar crest was -0.34, -1.29, and 0.04 mm, respectively (negative values indicate bone loss). For non-submerged implants, the respective values were -0.38, -1.13, and 0.19 mm. For submerged and non-submerged implants, there were significant differences in the amount of bone change among the three groups (P <0.05). The percentage of bone-to-implant contact for submerged implants was 73.3%, 71.8%, and 71.5%. For non-submerged implants, the respective numbers were 73.2%, 74.5%, and 76%. No significant differences occurred with regard to the percentage of bone contact. CONCLUSIONS: Minimal histologic bone loss occurred when dental implants with non-matching implant-abutment diameters were placed at the bone crest and were loaded for 6 months in the canine. The bone loss was significantly less (five- to six-fold) than that reported for bone-level implants with matching implant-abutment diameters (butt-joint connections).

Relevância:

100.00% 100.00%

Publicador:

Resumo:

OBJECTIVE The aim of the therapy is mechanical and functional stabilization of high dislocated hips with dysplasia coxarthrosis using total hip arthroplasty (THA). INDICATIONS Developmental dysplasia of the hip (DDH) in adults, symptomatic dysplasia coxarthrosis, high hip dislocation according to Crowe type III/IV, and symptomatic leg length inequality. CONTRAINDICATIONS Cerebrospinal dysfunction, muscular dystrophy, apparent disturbance of bone metabolism, acute or chronic infections, and immunocompromised patients. SURGICAL TECHNIQUE With the patient in a lateral decubitus position an incision is made between the anterior border of the gluteus maximus muscle and the posterior border of the gluteus medius muscle (Gibson interval). Identification of the sciatic nerve to protect the nerve from traction disorders by visual control. After performing trochanter flip osteotomy, preparation of the true actetabulum if possible. Implantation of the reinforcement ring, preparation of the femur and if necessary for mobilization, resection until the trochanter minor. Test repositioning under control of the sciatic nerve. Finally, refixation of the trochanteric crest. POSTOPERATIVE MANAGEMENT During hospital stay, intensive mobilization of the hip joint using a continuous passive motion machine with maximum flexion of 70°. No active abduction and passive adduction over the body midline. Maximum weight bearing 10-15 kg for 8 weeks, subsequently, first clinical and radiographic follow-up and deep venous thrombosis prophylaxis until full weight bearing. RESULTS From 1995 to 2012, 28 THAs of a Crow type IV high hip-dislocation were performed in our institute. Until now 14 patients have been analyzed during a follow-up of 8 years in 2012. Mid-term results showed an improvement of the postoperative clinical score (Merle d'Aubigné score) in 86 % of patients. Good to excellent results were obtained in 79 % of cases. Long-term results are not yet available. In one case an iatrogenic neuropraxia of the sciatic nerve was observed and after trauma a redislocation of the arthroplasty appeared in another case. In 2 cases an infection of the THA appeared 8 and 15 months after index surgery. No pseudoarthrosis of the trochanter or aseptic loosening was noticed.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

BACKGROUND Acetabular retroversion is associated with pincer-type femoroacetabular impingement and can lead to hip osteoarthritis. We report the ten-year results of a previously described patient cohort that had corrective periacetabular osteotomy for the treatment of symptomatic acetabular retroversion. METHODS Clinical and radiographic parameters were assessed preoperatively and at two and ten years postoperatively. A Kaplan-Meier survivorship analysis of the twenty-two patients (twenty-nine hips) with a mean follow-up (and standard deviation) of 11 ± 1 years (range, nine to twelve years) was performed. In addition, a univariate Cox regression analysis was done with conversion to total hip arthroplasty as the primary end point and progression of the osteoarthritis, a fair or poor result according to the Merle d'Aubigné score, or the need for revision surgery as the secondary end points. RESULTS The mean Merle d'Aubigné score improved significantly from 14 ± 1.4 points (range, 12 to 17 points) preoperatively to 16.9 ± 0.9 points (range, 15 to 18 points) at ten years (p < 0.001). There were also significant improvements with regard to hip flexion (p = 0.003), internal rotation (p = 0.003), and adduction (p = 0.002) compared with the preoperative status. No significant increase of the mean Tönnis osteoarthritis score was seen at ten years (p = 0.06). The cumulative ten-year survivorship, with conversion to a total hip arthroplasty as the primary end point, was 100%. The cumulative ten-year survivorship in achievement of one of the secondary end points was 71% (95% confidence interval, 54% to 88%). Predictors for poor outcome were the lack of femoral offset creation and overcorrection of the acetabular version resulting in excessive anteversion. CONCLUSIONS Anteverting periacetabular osteotomy for acetabular retroversion leads to favorable long-term results with preservation of the native hip at a mean of ten years. Overcorrection resulting in excessive anteversion of the hip and omitting concomitant offset creation of the femoral head-neck junction are associated with an unfavorable outcome.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Background: There are several numerical investigations on bone remodelling after total hip arthroplasty (THA) on the basis of the finite element analysis (FEA). For such computations certain boundary conditions have to be defined. The authors chose a maximum of three static load situations, usually taken from the gait cycle because this is the most frequent dynamic activity of a patient after THA. Materials and methods: The numerical study presented here investigates whether it is useful to consider only one static load situation of the gait cycle in the FE calculation of the bone remodelling. For this purpose, 5 different loading cases were examined in order to determine their influence on the change in the physiological load distribution within the femur and on the resulting strain-adaptive bone remodelling. First, four different static loading cases at 25%, 45%, 65% and 85% of the gait cycle, respectively, and then the whole gait cycle in a loading regime were examined in order to regard all the different loadings of the cycle in the simulation. Results: The computed evolution of the apparent bone density (ABD) and the calculated mass losses in the periprosthetic femur show that the simulation results are highly dependent on the chosen boundary conditions. Conclusion: These numerical investigations prove that a static load situation is insufficient for representing the whole gait cycle. This causes severe deviations in the FE calculation of the bone remodelling. However, accompanying clinical examinations are necessary to calibrate the bone adaptation law and thus to validate the FE calculations.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Les arthroplasties totales de la hanche (ATH) et du genou (ATG) sont souvent offertes aux patients atteints de dégénérescence articulaire sévère. Bien qu’efficace chez la majorité des patients, ces interventions mènent à des résultats sous-optimaux dans de nombreux cas. Il demeure difficile d’identifier les patients à risque de résultats sous-optimaux à l’heure actuelle. L’identification de ces patients avant la chirurgie pourrait permettre d’optimiser la gamme de soins et de services offerts et de possiblement améliorer les résultats de leur chirurgie. Ce mémoire a comme objectifs : 1) de réaliser une revue systématique des déterminants associés à la douleur et aux incapacités fonctionnelles rapportées par les patients à moyen-terme suivant ces deux types d’arthroplastie et 2) de développer des modèles de prédiction clinique permettant l’identification des patients à risque de mauvais résultats en terme de douleur et d’incapacités fonctionnelles suivant l’ATH et l’ATG. Une revue systématique de la littérature identifiant les déterminants de la douleur et de la fonction suivant l’ATH et l’ATG a été réalisée dans quatre bases de données jusqu’en avril 2015 et octobre 2014, respectivement. Afin de développer un algorithme de prédiction pouvant identifier les patients à risque de résultats sous-optimaux, nous avons aussi utilisé des données rétrospectives provenant de 265 patients ayant subi une ATH à l’Hôpital Maisonneuve-Rosemont (HMR) de 2004 à 2010. Finalement, des données prospectives sur 141 patients recrutés au moment de leur inclusion sur une liste d’attente pour une ATG dans trois hôpitaux universitaires à Québec, Canada et suivis jusqu’à six mois après la chirurgie ont permis l’élaboration d’une règle de prédiction clinique permettant l’identification des patients à risque de mauvais résultats en terme de douleur et d’incapacités fonctionnelles. Vingt-deux (22) études d’une qualité méthodologique moyenne à excellente ont été incluses dans la revue. Les principaux déterminants de douleur et d’incapacités fonctionnelles après l’ATH incluaient: le niveau préopératoire de douleur et de fonction, un indice de la masse corporelle plus élevé, des comorbidités médicales plus importantes, un état de santé générale diminué, une scolarité plus faible, une arthrose radiographique moins sévère et la présence d’arthrose à la hanche controlatérale. Trente-quatre (34) études évaluant les déterminants de douleur et d’incapacités fonctionnelles après l’ATG avec une qualité méthodologique moyenne à excellente ont été évaluées et les déterminants suivant ont été identifiés: le niveau préopératoire de douleur et de fonction, des comorbidités médicales plus importantes, un état de santé générale diminué, un plus grands niveau d’anxiété et/ou de symptômes dépressifs, la présence de douleur au dos, plus de pensées catastrophiques ou un faible niveau socioéconomique. Pour la création d’une règle de prédiction clinique, un algorithme préliminaire composé de l’âge, du sexe, de l’indice de masse corporelle ainsi que de trois questions du WOMAC préopératoire a permis l’identification des patients à risque de résultats chirurgicaux sous-optimaux (pire quartile du WOMAC postopératoire et percevant leur hanche opérée comme artificielle avec des limitations fonctionnelles mineures ou majeures) à une durée moyenne ±écart type de 446±171 jours après une ATH avec une sensibilité de 75.0% (95% IC: 59.8 – 85.8), une spécificité de 77.8% (95% IC: 71.9 – 82.7) et un rapport de vraisemblance positif de 3.38 (98% IC: 2.49 – 4.57). Une règle de prédiction clinique formée de cinq items du questionnaire WOMAC préopratoire a permis l’identification des patients en attente d’une ATG à risque de mauvais résultats (pire quintile du WOMAC postopératoire) six mois après l’ATG avec une sensibilité de 82.1 % (95% IC: 66.7 – 95.8), une spécificité de 71.7% (95% IC: 62.8 – 79.8) et un rapport de vraisemblance positif de 2.9 (95% IC: 1.8 – 4.7). Les résultats de ce mémoire ont permis d’identifier, à partir de la littérature, une liste de déterminants de douleur et d’incapacités fonctionnelles après l’ATH et l’ATG avec le plus haut niveau d’évidence à ce jour. De plus, deux modèles de prédiction avec de très bonnes capacités prédictives ont été développés afin d’identifier les patients à risque de mauvais résultats chirurgicaux après l’ATH et l’ATG. L’identification de ces patients avant la chirurgie pourrait permettre d’optimiser leur prise en charge et de possiblement améliorer les résultats de leur chirurgie.