878 resultados para Cement panel
Resumo:
In this day of the mature highway systems, a new set of problems is facing the highway engineer. The existing infrastructure has aged to or past the design life of the original pavement design. In many cases, increased commercial traffic is creating the need for additional load carrying capacity, causing state highway engineers to consider new alternatives for rehabilitation of existing surfaces. Alternative surface materials, thicknesses, and methods of installation must be identified to meet the needs of individual pavements and budgets. With overlays being one of the most frequently used rehabilitation alternatives, it is important to learn more about the limitations and potential performance of thin bonded portland cement overlays and subsequent rehabilitation. The Iowa ultra-thin project demonstrated the application of thin portland cement concrete overlays as a rehabilitation technique. It combined the variables of base preparation, overlay thickness, slab size, and fiber enhancement into a series of test sections over a 7.2-mile length. This report identifies the performance of the overlays in terms of deflection reduction, reduced cracking, and improved bonding between the portland cement concrete (PCC) and asphalt cement concrete (ACC) base layers. The original research project was designed to evaluate the variables over a 5-year period of time. A second project provided the opportunity to test overlay rehabilitation techniques and continue measurement of the original overlay performance for 5 additional years. All performance indicators identified exceptional performance over the 10-year evaluation period for each of the variable combinations considered. The report summarizes the research methods, results, and identifies future research ideas to aid the pavement overlay designer in the successful implementation of ultra-thin portland cement concrete overlays as an lternative pavement rehabilitation technique.
Resumo:
Introduction: High-grade evidence is lacking for most therapeutic decisions in Crohn's disease. Appropriateness criteria were developed for upper gastro-intestinal, extra-intestinal manifestations and drug safety during conception, pregnancy and breastfeeding in patients with Crohn's disease, to assist the physician in clinical decision making. Methods: The European Panel on the Appropriateness of Crohn's Disease Therapy (EPACT II), a multidisciplinary international European expert panel, rated clinical scenarios based on evidence from the published literature and panelists' own clinical expertise. Median ratings (on a 9-point scale) were stratified into three categories: appropriate (7-9), uncertain (4-6 with or without disagreement) and inappropriate (1-3). Experts were also asked to rank appropriate medications by priority. Results: Proton pump inhibitors, steroids, azathioprine/6-mercaptopurine and infliximab are appropriate for upper gastro-duodenal Crohn's disease; for stenosis, endoscopic balloon dilation is the first-tine therapy, although surgery is also appropriate. Ursodeoxycholic acid is the only appropriate treatment for primary sclerosing cholangitis. Infliximab is appropriate for Pyoderma gangrenosum, ankylosing spondylitis and uveitis, steroids for Pyoderma gangrenosum and ankylosing spondylitis, adalimumab for Pyoderma gangrenosum and ankylosing spondylitis, cyclosporine-A/tacrolimus for Pyoderma gangrenosum. Mesalamine, sulfasalazine, prednisone, azathioprine/6-mercaptopurine, ciprofloxacin, and probiotics, may be administered safety during pregnancy or for patients wishing to conceive, with the exception that mate patients considering conception should avoid sulfasalazine. Metronidazol is considered safe in the 2nd and 3rd trimesters whereas infliximab is rated safe in the 1st trimester but uncertain in the 2nd and 3rd trimesters. Methotrexate is always contraindicated at conception, during pregnancy or during breastfeeding, due to its known teratogenicity. Mesalamine, prednisone, probiotics and infliximab are considered safe during breastfeeding. Conclusion: EPACT II recommendations are freely available online (www.epact.ch). The validity of these criteria should now be tested by prospective evaluation. (C) 2009 European Crohn's and Colitis Organisation. Published by Elsevier B.V. All rights reserved.
Resumo:
This paper proposes a method to conduct inference in panel VAR models with cross unit interdependencies and time variations in the coefficients. The approach can be used to obtain multi-unit forecasts and leading indicators and to conduct policy analysis in a multiunit setups. The framework of analysis is Bayesian and MCMC methods are used to estimate the posterior distribution of the features of interest. The model is reparametrized to resemble an observable index model and specification searches are discussed. As an example, we construct leading indicators for inflation and GDP growth in the Euro area using G-7 information.
Resumo:
The aim of this paper is to analyse the impact of university knowledge and technology transfer activities on academic research output. Specifically, we study whether researchers with collaborative links with the private sector publish less than their peers without such links, once controlling for other sources of heterogeneity. We report findings from a longitudinal dataset on researchers from two engineering departments in the UK between 1985 until 2006. Our results indicate that researchers with industrial links publish significantly more than their peers. Academic productivity, though, is higher for low levels of industry involvement as compared to high levels.
Resumo:
Four standard radiation qualities (from RQA 3 to RQA 9) were used to compare the imaging performance of a computed radiography (CR) system (general purpose and high resolution phosphor plates of a Kodak CR 9000 system), a selenium-based direct flat panel detector (Kodak Direct View DR 9000), and a conventional screen-film system (Kodak T-MAT L/RA film with a 3M Trimax Regular screen of speed 400) in conventional radiography. Reference exposure levels were chosen according to the manufacturer's recommendations to be representative of clinical practice (exposure index of 1700 for digital systems and a film optical density of 1.4). With the exception of the RQA 3 beam quality, the exposure levels needed to produce a mean digital signal of 1700 were higher than those needed to obtain a mean film optical density of 1.4. In spite of intense developments in the field of digital detectors, screen-film systems are still very efficient detectors for most of the beam qualities used in radiology. An important outcome of this study is the behavior of the detective quantum efficiency of the digital radiography (DR) system as a function of beam energy. The practice of users to increase beam energy when switching from a screen-film system to a CR system, in order to improve the compromise between patient dose and image quality, might not be appropriate when switching from screen-film to selenium-based DR systems.
Resumo:
BACKGROUND: This study examined the reliability of explicit guidelines developed using the RAND-UCLA appropriateness method. METHODS: The appropriateness of over 400 indications for colonoscopy was rated by two multispecialty expert panels (United States and Switzerland). A nine-point scale was used, which was consolidated into three categories of appropriateness: appropriate, uncertain, inappropriate. The distribution of appropriateness ratings between the two panels and the intrapanel and interpanel agreement for categories of appropriateness were calculated for all possible indications. Similar statistics were calculated for a series of 577 primary care patients referred for colonoscopy in Switzerland. RESULTS: Over 80% of all indications (348) could be directly compared. The proportions of indications classified as appropriate, uncertain, or inappropriate were 28.4%, 24.7%, 46.6% and 33.0%, 23.0%, 44.0% for the U.S. and the Swiss panels, respectively. Interpanel agreement was excellent for all the possible indications (kappa value: 0.75) and lower for actual cases (kappa value: 0.51) because of lower agreement for the most frequently encountered indications. CONCLUSIONS: Good agreement between the two sets of criteria was found, pointing to the reliability of the method. Partial disagreement occurred essentially for a few, albeit frequently encountered, indications for use of colonoscopy in cases of uncomplicated lower abdominal pain or constipation.
Resumo:
A new debate over the speed of convergence in per capita income across economies is going on. Cross sectional estimates support the idea of slow convergence of about two percent per year. Panel data estimates support the idea of fast convergence of five, ten or even twenty percent per year. This paper shows that, if you ``do it right'', even the panel data estimation method yields the result of slow convergence of about two percent per year.
Resumo:
Presenta las regulaciones de la pesquería de la anchoveta para asegurar el mantenimiento de las capturas al/o cerca del nivel del rendimiento máximo sostenido y obtener la captura a un costo mínimo y utilizarla para obtener la máxima ganancia dentro de la estructura social, política y técnico económica de la industria.
Resumo:
This paper aims to estimate a translog stochastic frontier production function in the analysis of a panel of 150 mixed Catalan farms in the period 1989-1993, in order to attempt to measure and explain variation in technical inefficiency scores with a one-stage approach. The model uses gross value added as the output aggregate measure. Total employment, fixed capital, current assets, specific costs and overhead costs are introduced into the model as inputs. Stochasticfrontier estimates are compared with those obtained using a linear programming method using a two-stage approach. The specification of the translog stochastic frontier model appears as an appropriate representation of the data, technical change was rejected and the technical inefficiency effects were statistically significant. The mean technical efficiency in the period analyzed was estimated to be 64.0%. Farm inefficiency levels were found significantly at 5%level and positively correlated with the number of economic size units.
Resumo:
We provide methods for forecasting variables and predicting turning points in panel Bayesian VARs. We specify a flexible model which accounts for both interdependencies in the cross section and time variations in the parameters. Posterior distributions for the parameters are obtained for a particular type of diffuse, for Minnesota-type and for hierarchical priors. Formulas for multistep, multiunit point and average forecasts are provided. An application to the problem of forecasting the growth rate of output and of predicting turning points in the G-7 illustrates the approach. A comparison with alternative forecasting methods is also provided.
Resumo:
BACKGROUND: The quality of colon cleansing is a major determinant of quality of colonoscopy. To our knowledge, the impact of bowel preparation on the quality of colonoscopy has not been assessed prospectively in a large multicenter study. Therefore, this study assessed the factors that determine colon-cleansing quality and the impact of cleansing quality on the technical performance and diagnostic yield of colonoscopy. METHODS: Twenty-one centers from 11 countries participated in this prospective observational study. Colon-cleansing quality was assessed on a 5-point scale and was categorized on 3 levels. The clinical indication for colonoscopy, diagnoses, and technical parameters related to colonoscopy were recorded. RESULTS: A total of 5832 patients were included in the study (48.7% men, mean age 57.6 [15.9] years). Cleansing quality was lower in elderly patients and in patients in the hospital. Procedures in poorly prepared patients were longer, more difficult, and more often incomplete. The detection of polyps of any size depended on cleansing quality: odds ratio (OR) 1.73: 95% confidence interval (CI)[1.28, 2.36] for intermediate-quality compared with low-quality preparation; and OR 1.46: 95% CI[1.11, 1.93] for high-quality compared with low-quality preparation. For polyps >10 mm in size, corresponding ORs were 1.0 for low-quality cleansing, OR 1.83: 95% CI[1.11, 3.05] for intermediate-quality cleansing, and OR 1.72: 95% CI[1.11, 2.67] for high-quality cleansing. Cancers were not detected less frequently in the case of poor preparation. CONCLUSIONS: Cleansing quality critically determines quality, difficulty, speed, and completeness of colonoscopy, and is lower in hospitalized patients and patients with higher levels of comorbid conditions. The proportion of patients who undergo polypectomy increases with higher cleansing quality, whereas colon cancer detection does not seem to critically depend on the quality of bowel preparation.