992 resultados para Calorimetry.


Relevância:

10.00% 10.00%

Publicador:

Resumo:

Meal-Induced Thermogenesis (MIT) research findings are highly inconsistent, in part, due to the variety of durations and protocols used to measure MIT. We aimed to determine: 1) the proportion of a 6 h MIT response completed at 3, 4 and 5 h; 2) the associations between the shorter durations and the 6 h measure; 3) whether shorter durations improved the reproducibility of the measurement. MIT was measured in response to a 2410 KJ mixed composition meal in ten individuals (5 male, 5 female) on two occasions. Energy expenditure was measured continuously for 6 h post-meal using indirect calorimetry and MIT was calculated as the increase in energy expenditure above the pre-meal RMR. On average, 76%, 89%, and 96% of the 6 h MIT response was completed within 3, 4 and 5 h respectively, and the MIT at each of these time points was strongly correlated to the 6 h MIT (range for correlations, r = 0.990 to 0.998; p < 0.01). The between-day CV for the 6 h measurement was 33%, but was significantly lower after 3 h of measurement (CV = 26%, p = 0.02). Despite variability in the total MIT between days, the proportion of the MIT that was complete at 3, 4 and 5 h was reproducible (mean CV: 5%). While 6 h is typically required to measure the complete MIT response, 3 h measures provide sufficient information about the magnitude of the MIT response and may be applicable for measuring individuals on repeated occasions.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Major imperfections in crosslinked polymers include loose or dangling chain ends that lower the crosslink d., thereby reducing elastic recovery and increasing the solvent swelling. These imperfections are hard to detect, quantify and control when the network is initiated by free radical reactions. As an alternative approach, the sol-​gel synthesis of a model poly(ethylene glycol) (PEG-​2000) network is described using controlled amts. of bis- and mono-​triethoxy silyl Pr urethane PEG precursors to give silsesquioxane (SSQ, R-​SiO1.5) structures as crosslink junctions with a controlled no. of dangling chains. The effect of the no. of dangling chains on the structure and connectivity of the dried SSQ networks has been detd. by step-​crystn. differential scanning calorimetry. The role that micelle formation plays in controlling the sol-​gel PEG network connectivity has been studied by dynamic light scattering of the bis- and mono-​triethoxy silyl precursors and the networks have been characterized by 29Si solid state NMR, sol fraction and swelling measurements. These show that the dangling chains will increase the mesh size and water uptake. Compared to other end-​linked PEG hydrogels, the SSQ-​crosslinked networks show a low sol fraction and high connectivity, which reduces solvent swelling, degree of crystallinity and the crystal transition temp. The increased degree of freedom in segment movement on the addn. of dangling chains in the SSQ-​crosslinked network facilitates the packing process in crystn. of the dry network and, in the hydrogel, helps to accommodate more water mols. before reaching equil.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

OBJECTIVES: To compare the classification accuracy of previously published RT3 accelerometer cut-points for youth using energy expenditure, measured via portable indirect calorimetry, as a criterion measure. DESIGN: Cross-sectional cross-validation study. METHODS: 100 children (mean age 11.2±2.8 years, 61% male) completed 12 standardized activities trials (3 sedentary, 5 lifestyle and 4 ambulatory) while wearing an RT3 accelerometer. V˙O2 was measured concurrently using the Oxycon Mobile portable calorimeter. Cut-points by Vanhelst (VH), Rowlands (RW), Chu (CH), Kavouras (KV) and the RT3 manufacturer (RT3M) were used to classify PA intensity as sedentary (SED), light (LPA), moderate (MPA) or vigorous (VPA). Classification accuracy was evaluated using the area under the Receiver Operating Characteristic curve (ROC-AUC) and weighted Kappa (κ). RESULTS: For moderate-to-vigorous PA (MVPA), VH, KV and RW exhibited excellent accuracy classification (ROC-AUC≥0.90), while the CH and RT3M exhibited good classification accuracy (ROC-AUC>0.80). Classification accuracy for LPA was fair to poor (ROC-AUC<0.76). For SED, VH exhibited excellent classification accuracy (ROC-AUC>0.90), while RW, CH, and RT3M exhibited good classification accuracy (ROC-AUC>0.80). Kappa statistics ranged from 0.67 (VH) to 0.55 (CH). CONCLUSIONS: All cut-points provided acceptable classification accuracy for SED and MVPA, but limited accuracy for LPA. On the basis of classification accuracy over all four levels of intensity, the use of the VH cut-points is recommended.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The absence of comparative validity studies has prevented researchers from reaching consensus regarding the application of intensity-related accelerometer cut points for children and adolescents. PURPOSE This study aimed to evaluate the classification accuracy of five sets of independently developed ActiGraph cut points using energy expenditure, measured by indirect calorimetry, as a criterion reference standard. METHODS A total of 206 participants between the ages of 5 and 15 yr completed 12 standardized activity trials. Trials consisted of sedentary activities (lying down, writing, computer game), lifestyle activities (sweeping, laundry, throw and catch, aerobics, basketball), and ambulatory activities (comfortable walk, brisk walk, brisk treadmill walk, running). During each trial, participants wore an ActiGraph GT1M, and VO 2 was measured breath-by-breath using the Oxycon Mobile portable metabolic system. Physical activity intensity was estimated using five independently developed cut points: Freedson/Trost (FT), Puyau (PU), Treuth (TR), Mattocks (MT), and Evenson (EV). Classification accuracy was evaluated via weighted κ statistics and area under the receiver operating characteristic curve (ROC-AUC). RESULTS Across all four intensity levels, the EV (κ = 0.68) and FT (κ = 0.66) cut points exhibited significantly better agreement than TR (κ = 0.62), MT (κ = 0.54), and PU (κ = 0.36). The EV and FT cut points exhibited significantly better classification accuracy for moderate-to vigorous-intensity physical activity (ROC-AUC = 0.90) than TR, PU, or MT cut points (ROC-AUC = 0.77-0.85). Only the EV cut points provided acceptable classification accuracy for all four levels of physical activity intensity and performed well among children of all ages. The widely applied sedentary cut point of 100 counts per minute exhibited excellent classification accuracy (ROC-AUC = 0.90). CONCLUSIONS On the basis of these findings, we recommend that researchers use the EV ActiGraph cut points to estimate time spent in sedentary, light-, moderate-, and vigorous-intensity activity in children and adolescents. Copyright © 2011 by the American College of Sports Medicine.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Purpose This Study evaluated the predictive validity of three previously published ActiGraph energy expenditure (EE) prediction equations developed for children and adolescents. Methods A total of 45 healthy children and adolescents (mean age: 13.7 +/- 2.6 yr) completed four 5-min activity trials (normal walking. brisk walking, easy running, and fast running) in ail indoor exercise facility. During each trial, participants were all ActiGraph accelerometer oil the right hip. EE was monitored breath by breath using the Cosmed K4b(2) portable indirect calorimetry system. Differences and associations between measured and predicted EE were assessed using dependent t-tests and Pearson correlations, respectively. Classification accuracy was assessed using percent agreement, sensitivity, specificity, and area under the receiver operating characteristic (ROC) curve. Results None of the equations accurately predicted mean energy expenditure during each of the four activity trials. Each equation, however, accurately predicted mean EE in at least one activity trial. The Puyau equation accurately predicted EE during slow walking. The Trost equation accurately predicted EE during slow running. The Freedson equation accurately predicted EE during fast running. None of the three equations accurately predicted EE during brisk walking. The equations exhibited fair to excellent classification accuracy with respect to activity intensity. with the Trost equation exhibiting the highest classification accuracy and the Puyau equation exhibiting the lowest. Conclusions These data suggest that the three accelerometer prediction equations do not accurately predict EE on a minute-by-minute basis in children and adolescents during overground walking and running. The equations maybe, however, for estimating participation in moderate and vigorous activity.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Purpose To evaluate the validity of a uniaxial accelerometer (MTI Actigraph) for measuring physical activity in people with acquired brain injury (ABI) using portable indirect calorimetry (Cosmed K4b(2)) as a criterion measure. Methods Fourteen people with ABI and related gait pattern impairment (age 32 +/- 8 yr) wore an MTI Actigraph that measured activity (counts(.)min-(1)) and a Cosmed K4b(2) that measured oxygen consumption (mL(.)kg(-1.)min(-1)) during four activities: quiet sitting (QS) and comfortable paced (CP), brisk paced (BP), and fast paced (FP) walking. MET levels were predicted from Actigraph counts using a published equation and compared with Cosmed measures. Predicted METs for each of the 56 activity bouts (14 participants X 4 bouts) were classified (light, moderate, vigorous, or very vigorous intensity) and compared with Cosmed-based classifications. Results Repeated-measures ANOVA indicated that walking condition intensities were significantly different (P < 0.05) and the Actigraph detected the differences. Overall correlation between measured and predicted METs was positive, moderate, and significant (r = 0.74). Mean predicted METs were not significantly different from measured for CP and BP, but for FP walking, predicted METs were significantly less than measured (P < 0.05). The Actigraph correctly classified intensity for 76.8% of all activity bouts and 91.5% of light- and moderate-intensity bouts. Conclusions Actigraph counts provide a valid index of activity across the intensities investigated in this study. For light to moderate activity, Actigraph-based estimates of METs are acceptable for group-level analysis and are a valid means of classifying activity intensity. The Actigraph significantly underestimated higher intensity activity, although, in practice, this limitation will have minimal impact on activity measurement of most community-dwelling people with ABI.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

To evaluate the validity of the ActiGraph accelerometer for the measurement of physical activity intensity in children and adolescents with cerebral palsy (CP) using oxygen uptake (VO 2) as the criterion measure. Thirty children and adolescents with CP (mean age 12.6 ± 2.0 years) wore an ActiGraph 7164 and a Cosmed K4b 2 portable indirect calorimeter during four activities; quiet sitting, comfortable paced walking, brisk paced walking and fast paced walking. VO 2 was converted to METs and activity energy expenditure and classiWed as sedentary, light or moderate-to-vigorous intensity according to the conventions for children. Mean ActiGraph counts min -1 were classiWed as sedentary, light or moderate-to-vigorous (MVPA) intensity using four diVerent sets of cut-points. VO 2 and counts min¡1 increased signiWcantly with increases in walking speed (P < 0.001). Receiver operating characteristic (ROC) curve analysis indicated that, of the four sets of cut-points evaluated, the Evenson et al. (J Sports Sci 26(14):1557-1565, 2008) cut-points had the highest classiWcation accuracy for sedentary (92%) and MVPA (91%), as well as the second highest classiWcation accuracy for light intensity physical activity (67%). A ROC curve analysis of data from our participants yielded a CP-speciWc cut-point for MVPA that was lower than the Evenson cut-point (2,012 vs. 2,296 counts min¡1), however, the diVerence in classiWcation accuracy was not statistically signiWcant 94% (95% CI = 88.2-97.7%) vs. 91% (95% CI = 83.5-96.5%). In conclusion, among children and adolescents with CP, the ActiGraph is able to diVerentiate between diVerent intensities of walking. The use of the Evenson cut-points will permit the estimation of time spent in MVPA and allows comparisons to be made between activity measured in typically developing adolescents and adolescents with CP. © 2011 Springer-Verlag.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Background Promoting participation physical activity (PA) is an important means of promoting healthy growth and development in children with cerebral palsy (CP). The ActiGraph is a uniaxial accelerometer that provides a realtime measure of PA intensity, duration and frequency. Its small, light weight design makes it a promising measure of activity in children with CP. To date no study has validated the use of accelerometry as a measure of PA in ambulant adolescents with CP. Objectives To evaluate the validity of the ActiGraph accelerometer for measuring PA intensity in adolescents with CP, using oxygen consumption (VO2), measured using portable indirect calorimetry (Cosmed K4b2), as the criterion measure. Design Validation Study Participants/Setting: Ambulant adolescents with CP aged 10–16 years, GMFCS rating of I-III. The recruitment target is 30 (10 in each GMFCS level). Materials/Methods Participants wore the ActiGraph (counts/min) and a Cosmed K4b2 indirect calorimeter (mL/kg/min) during six activity trials: quiet sitting (QS), comfortable paced walking (CPW), brisk paced walking (BPW), fast paced walking (FPW), a ball-kicking protocol (KP) and a ball-throwing protocol (TP). MET levels (multiples of resting metabolism) for each activity were predicted from ActiGraph counts using the Freedson age-specific equation (Freedson et al. 2005) and compared with actual MET levels measured by the Cosmed. Predicted and measured METs for each activity trial were classified as light (> 1.5 METs and <4.6 METs) or moderate to vigorous intensity (≥ 4.6 METs). Results To date 36 bouts of activity have been completed (6 participants x 6 activities). Mean VO2 increased linearly as the intensity of the walking activity increased (CPW=9.47±2.16, BPW=14.06±4.38, FPW=19.21±5.68 ml/kg/min) and ActiGraph counts reflected this pattern (CPW=1099±574, BPW=2233±797 FPW=4707±1013 counts/min). The throwing protocol recording the lowest VO2 (TP=7.50±3.86 ml/kg/min) and lowest overall counts/min (TP=31±27 counts/min). When each of the 36 bouts were classified as either light or moderate to vigorous intensity using measured VO2 as the criterion measure, the Freedson equation correctly classified 28 from 36 bouts (78%). Conclusion/Clinical Implications These preliminary findings suggest that there is a relationship between the intensity of PA and direct measure of oxygen consumption and that therefore the ActiGraph may be a promising tool for accurately measuring free living PA in the community. Further data collection of the complete sample will enable secondary analysis of the relationship between PA and severity of CP (GMFCS level).

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Purpose The aim of this study was to assess the predictive validity of three accelerometer prediction equations (Freedson et aL, 1997; Trost et aL, 1998; Puyau et al., 2002) for energy expenditure (EE) during overland walking and running in children and adolescents. Methods 45 healthy children and adolescents aged 10-18 completed the following protocol, each task 5-mins in duration, with a 5-min rest period in between; walking normally; walking briskly; running easily and running fast. During each task participants wore MTI (WAM 7164) Actigraphs on the left and right hips. VO2 was monitored breath by breath using the Cosmed K4b2 portable indirect calorimetry system. For each prediction equation, difference scores were calculated as EE measured minus EE predicted. The percentage of 1-min epochs correctly categorized as light (<3 METs), moderate (3-5.9 METs), and vigorous (≥6 METS) was also calculated. Results The Freedson and Trost equations consistently overestimated MET level. The level of overestimation was statistically significant across all tasks for the Freedson equation, and was significant for only the walking tasks for the Trost equation. The Puyau equation consistently underestimated AEE with the exception of the walking normally task. In terms of categorisation, the Freedson equation (72.8% agreement) demonstrated better agreement than the Puyau (60.6%). Conclusions These data suggest that the three accelerometer prediction equations do not accurately predict EE on a minute-by-minute basis in children and adolescents during overland walking and running. However, the cut points generated by these equations maybe useful for classifying activity as either, light, moderate, or vigorous.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The effect of graphene oxide (GO) on the mechanical properties and the curing reaction of Diglycidyl Ether of Bisphenol A/F and Triethylenetetramine epoxy system was investigated. GO was prepared by oxidation of graphite flakes and characterized by spectroscopic and microscopic techniques. Epoxy nanocomposites were fabricated with different GO loading by solution mixing technique. It was found that incorporation of small amount of GO into the epoxy matrix significantly enhanced the mechanical properties of the epoxy. In particular, model I fracture toughness was increased by nearly 50% with the addition of 0.1 wt. % GO to epoxy. The toughening mechanism was understood by fractography analysis of the tested samples. The more irregular, coarse, and multi-plane fracture surfaces of the epoxy/GO nanocomposites were observed. This implies that the two-dimensional GO sheets effectively disturbed and deflected the crack propagation. At 0.5 wt. % GO, elastic modulus was ~35% greater than neat epoxy. Differential scanning calorimetry (DSC) results showed that GO addition moderately affect the glass transition temperature (Tg) of epoxy. The maximum decrease of Tg by ~7 oC was shown for the nanocomposite with 0.5 wt. % GO. DSC results further revealed that GO significantly hindered the cure reaction in the epoxy system.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

A fluorenone based alternating copolymer (PFN-DPPF) with a furan based fused aromatic moiety has been designed and synthesized. PFN-DPPF exhibits a small band gap with a lower HOMO value. Testing this polymer semiconductor as the active layer in organic thin-film transistors results in hole mobilities as high as 0.15 cm2 V-1 s-1 in air.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The dendritic triazole-based complexes \[Fe(G1-BOC)3](triflate) 2·xH2O (1; G1-BOC = tert-butyl {3-\[3-(3-tert- butoxycarbonylaminopropyl)-5-(\[1,2,4]triazol-4-ylcarbamoyl)-phenyl]propyl} carbamate, triflate = CF3SO3-), \[Fe(G1-BOC) 3]-(tosylate)2·xH2O(2;tosylate = p-CH3PhSO3-),\[Fe(G1-DPBE)3]-(triflate) 2·xH2O {3; G1-DPBE = 3,5-bis(3,5- didodecaoxybenzyloxy)-N-\[1,2,4]triazol-4-ylbenzamide}, \[Fe(G1-DPBE) 3]-(tosylate)2·xH2O (4) and \[Fe(G1-DPBE)3](BF4)2·xH2O (5) were designed and synthesized. Magnetic and thermal properties of these novel complexes were characterized by magnetic susceptibility measurements, 57Fe Mössbauer spectroscopy and thermogravimetric analysis or differential scanning calorimetry, respectively. All dendritic complexes under study show different spin-transition behaviour with respect to the nature of different dendritic ligands and counteranions. Complexes 1 and 2 have pronounced effects of a spin-state change during the first heating process and gradual spintransition properties for further temperature treatments, whereas 3 and 4 exhibited a very sharp spin-state change in the first heating procedures. Complex 5 showed a gradual spin-transition curve. In this paper, we report how the magnetic properties of these complexes are correlated with noncoordinated water molecules and their effects on spin states.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The thermal decomposition process of kaolinite–potassium acetate intercalation complex has been studied using simultaneous thermogravimetry coupled with Fourier-transform infrared spectroscopy and mass spectrometry (TG-FTIR-MS). The results showed that the thermal decomposition of the complex took place in four temperature ranges, namely 50–100, 260–320, 320–550, and 650–780 °C. The maximal mass losses rate for the thermal decomposition of the kaolinite–potassium acetate intercalation complex was observed at 81, 296, 378, 411, 486, and 733 °C, which was attributed to (a) loss of the adsorbed water, (b) thermal decomposition of surface-adsorbed potassium acetate (KAc), (c) the loss of the water coordinated to potassium acetate in the intercalated kaolinite, (d) the thermal decomposition of intercalated KAc in the interlayer of kaolinite and the removal of inner surface hydroxyls, (e) the loss of the inner hydroxyls, and (f) the thermal decomposition of carbonate derived from the decomposition of KAc. The thermal decomposition of intercalated potassium acetate started in the range 320–550 °C accompanied by the release of water, acetone, carbon dioxide, and acetic acid. The identification of pyrolysis fragment ions provided insight into the thermal decomposition mechanism. The results showed that the main decomposition fragment ions of the kaolinite–KAc intercalation complex were water, acetone, carbon dioxide, and acetic acid. TG-FTIR-MS was demonstrated to be a powerful tool for the investigation of kaolinite intercalation complexes. It delivers a detailed insight into the thermal decomposition processes of the kaolinite intercalation complexes characterized by mass loss and the evolved gases.