843 resultados para COATED ELECTRODE


Relevância:

20.00% 20.00%

Publicador:

Resumo:

A metalloporphyrin incorporated carbon paste sensor has been developed for the determination of metronidazole benzoate (MTZB). Zn(II) complex of 5,10,15,20-tetrakis (3-methoxy-4-hydroxy phenyl) porphyrin (TMHPP) was used as the active material. The MTZB gave a well-defined reduction peak at - 0.713V in 0.1 mol l -1 phosphate buffer solution of pH around 7. Compared with bare carbon paste electrode (CPE), the TMHPP Zn(II) modified electrode significantly enhanced the reduction peak current of MTZB as well as lowered its reduction potential. Under optimum conditions the reduction peak current was proportional to MTZB concentration over the range 1×10-3 mol1-1 to 1×10-5mol1-1. The detection limit was found to be 4.36×10-6mol1-1 . This sensor has been successfully applied for the determination of MTZB in pharmaceutical formulations and urine samples.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Inter-digital capacitive electrodes working as electric field sensors have been developed for touch panel applications. Evaluation circuits to convert variations in electric fields in such sensors into computer compatible data are commercially available. We report development of an Interdigital capacitive electrode working as a sensitive pressure sensor in the range 0-120 kPa. Essentially it is a touch/proximity sensor converted into a pressure sensor with a suitable elastomer buffer medium acting as the pressure transmitter. The performance of the sensor has been evaluated and reported. Such sensors can be made very economical in comparison to existing pressure sensors. Moreover, they are very convenient to be fabricated into sensor arrays involving a number of sensors for distributed pressure sensing applications such as in biomedical systems.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Brasses are widely used as constructional materials in marine environment due to their anticorrosive,antifouling and mechanical properties.However, its resistance to corrosion and fouling may vary according to local marine environmental condition and the seasons.The dezincification of brass is one of the forms of selective corrosion which has attracted the attention of researchers for the last two decades.Many of the dezincification mechanistic studies have been performed in noncomplex media and hence their conclusions cannot be extended to esturine water,which is of great significance since brass is extensively used in marine environment.Inhibited α brasses are largely immune to dezincication and the effect of tin and arsenic addition to α/beta brasses is not so reliable in controlling the dezincification. There have been many cases of dezincification in duplex brasses in both freshwater and seawater.Though there is some protection methods such as inhibitors,electro deposition and electro polymerization,there is no reliable method of inhibiting the dezincification of two-phase brass.Organic coatings are effectively used for the protection metals due to their capacity to act a physical barrieer between the metal surface and corrosive environment.Hence,pure epoxy coating is selected for this as it has antocorrosiion effect on brass.The dezincification behaviour of brass of the present study has been highlighted in terms of corrosion rate,weight gain/loss,corrosion current and polarization resistence,open circuit potential,dezincification factor. The marine fouling as biomass on brass was assessed and presented in this thesis, The physicochemical properties of estuarine water were correlated with corrosion behaviour of brass.The deterioration of the brass subjected to the effect of estuarine water was also investigated as a measure of loss in mechanical properties such as tensile strength,yield strength,percntage elongation and percentage reduction in area.To validate dezincification data,visual observation,spot analysis,surface morphology before and after removal of corrosion products and corrosion product analysis were performed.The dezincification behavior of epoxy coated brass of the present study has beenhighlighted in terms of corrosion rate ,weight gain/loss,corrosion current and polarization resistance,open circuit potential.dezincification factor.The marine fouling as biomass on epoxy coated brass subjeted to the effect of estuarine water was also investigated as ameasure of loss in mechanical properties such as tensile strength,percentage elongation and percentage reduction in area.The results of dezincification behavior of brass and epoxy coated brass in Cochin estuary water has been presented and discussed.Attempt has been made to correlate the dezincification behavior of brass with epoxy coated brass.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Photoemission optogalvanaic (POG) effect has been observed by irradiating copper target electrode, in a nitrogen discharge cell using 1.06 μm and frequency doubled 532 nm Nd:YAG laser pulse. Measurement of the nature of the variation of POG signal strength with 532 nm laser fluence confirms the two photon induced photoelectric emission from copper. However, using 1.06 μm laser pulses thermally assisted photoemission is observed.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This thesis consists of a study of the effect of electrode films and overlayer films on the electrical properties of certain metal films. The films have been prepared on glass substrates by thermal evapouration in a vaccum 10 terr. The properties of Al films on Ag, Al,Au and Cu films on In electrodes ,and Bi/Ag bilayer films have been studied. The influence of annealing electrodes at higher temperature on the electrical properties of metal films has also been investigated. Further the effect of varying layer thickness in the bilayer films ,both annealed at higher temperature and annealed at room temperature have been examined.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Voltammetric methods are applicable for the determination of a wide variety of both organic and inorganic species. Its features are compact equipment, simple sample preparation, short analysis time, high accuracy and sensitivity. Voltammetry is especially suitable for laboratories in which only a few parameters have to be monitored with a moderate sample throughput. Of various electrode materials, glassy carbon electrode is particularly useful because of its high electrical conductivity, impermeability to gases, high chemical resistance, reasonable mechanical and dimensional stability and widest potential range of all carbonaceous electrodes. Electrode modification is a vigorous research area by which the electrochemical determination of various analyte species is facilitated. The scope of pharmaceutical analysis includes the analytical investigation of pure drug, drug formulations, impurities and degradation products of drugs, biological samples containing the drugs and their metabolites with the aim of obtaining data that can contribute to the maximal efficacy and maximal safety of drug therapy. This thesis presents the modification of glassy carbon electrode using metalloporphyrin and dyes and subsequently using these modified electrodes for the determination of various pharmaceuticals. The thesis consists of 9 chapters.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The present work derives motivation from the so called surface/interfacial magnetism in core shell structures and commercial samples of Fe3O4 and c Fe2O3 with sizes ranging from 20 to 30 nm were coated with polyaniline using plasma polymerization and studied. The High Resolution Transmission Electron Microscopy images indicate a core shell structure after polyaniline coating and exhibited an increase in saturation magnetization by 2 emu/g. For confirmation, plasma polymerization was performed on maghemite nanoparticles which also exhibited an increase in saturation magnetization. This enhanced magnetization is rather surprising and the reason is found to be an interfacial phenomenon resulting from a contact potential.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Inhibited α brasses are largely immune to dezincification in most water, but the effect of tin and arsenic addition to α/β brasses is not so reliable or predictable in controlling the problem. There have been many cases of dezincification in duplex brasses in both fresh water and seawater. There is no reliable method of inhibiting the dezincification of two-phase brass despite there are some protection methods such as inhibitors, electro deposition and electro polymerization. Organic coatings are effectively used for the protection of metals due to their capacity to act as a physical barrier between the metal surface and corrosive environment. Hence, epoxy coating on brass was applied and effect of this against dezincification in Cochin estuarine water over a period of one year was studied and reported in this paper

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Thin film solar cells having structure CuInS2/In2S3 were fabricated using chemical spray pyrolysis (CSP) technique over ITO coated glass. Top electrode was silver film (area 0.05 cm2). Cu/In ratio and S/Cu in the precursor solution for CuInS2 were fixed as 1.2 and 5 respectively. In/S ratio in the precursor solution for In2S3 was fixed as 1.2/8. An efficiency of 0.6% (fill factor -37.6%) was obtained. Cu diffusion to the In2S3 layer, which deteriorates junction properties, is inevitable in CuInS2/In2S3 cell. So to decrease this effect and to ensure a Cu-free In2S3 layer at the top of the cell, Cu/In ratio was reduced to 1. Then a remarkable increase in short circuit current density was occurred from 3 mA/cm2 to 14.8 mA/cm2 and an efficiency of 2.13% was achieved. Also when In/S ratio was altered to 1.2/12, the short circuit current density increased to 17.8 mA/cm2 with an improved fill factor of 32% and efficiency remaining as 2%. Thus Cu/In and In/S ratios in the precursor solutions play a crucial role in determining the cell parameters

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Der pH-Wert stellt in der Chemie, Physik, Biologie, Pharmazie und Medizin eine wichtige Meßgröße dar, da eine Vielzahl von Reaktionen durch den pH-Wert bestimmt wird. In der Regel werden zur pH-Wert-Messung Glaselektroden eingesetzt. Hierbei konnte der pH-sensitive Bereich zwar bis auf einige Mikrometer reduziert werden, aber die Gesamtab-messungen betragen immer noch 15-20 cm. Mit der Einführung miniaturisierter Reaktionsgefäße ist daher der Bedarf an miniaturisierten Sensoren enorm gestiegen. Um in solchen Gefäßen Reaktionsparameter wie z. B. den pH-Wert zu kontrollieren, müssen die Gesamtabmessungen der Sensoren verringert werden. Dies lässt sich mit Hilfe der Mikrostrukturtechnik von Silizium realisieren. Hiermit lassen sich Strukturen und ganze Systeme bis in den Nanometerbereich herstellen. Basierend auf Silizium und Gold als Elektrodenmaterial wurden im Rahmen dieser Arbeit verschiedene Interdigitalstrukturen hergestellt. Um diese Strukturen zur pH-Wert-Messungen einsetzen zu können, müssen sie mit einer pH-sensitiven Schicht versehen werden. Hierbei wurde Polyanilin, ein intrinsisch leitendes Polymer, aufgrund seine pH-abhängigen elektrischen und optischen Verhaltens eingesetzt. Die Beschichtung dieser Sensoren mit Polyanilin erfolgte vorwiegend elektrochemisch mit Hilfe der Zyklovoltammetrie. Neben der Herstellung reiner Polyanilinfilme wurden auch Kopolymerisationen von Anilin und seinen entsprechenden Aminobenzoesäure- bzw. Aminobenzensulfonsäurederivaten durchgeführt. Ergebnisse dazu werden vorgestellt und diskutiert. Zur Charakterisierung der resultierenden Polyanilin- und Kopolymerfilme auf den Inter-digitalstrukturen wurden mit Hilfe der ATR-FT-IR-Spektroskopie Spektren aufgenommen, die gezeigt und diskutiert werden. Eine elektrochemische Charakterisierung der Polymere erfolgte mittels der Zyklovoltammetrie. Die mit Polyanilin bzw. seinen Kopolymeren beschichteten Sensoren wurden dann für Widerstandsmessungen an den Polymerfilmen in wässrigen Medien eingesetzt. Polyanilin zeigt lediglich eine pH-Sensitivität in einem pH-Bereich von pH 2 bis pH 4. Durch den Einsatz der Kopolymere konnte dieser pH-sensitive Bereich jedoch bis zu einem pH-Wert von 10 ausgeweitet werden. Zur weiteren Miniaturisierung der Sensoren wurde das Konzept der interdigitalen Elektroden-paare auf Cantilever übertragen. Die pH-sensitive Zone konnte dabei auf 500 µm2 bei einer Gesamtlänge des Sensors (Halter mit integriertem Cantilever) von 4 mm reduziert werden. Neben den elektrischen pH-abhängigen Eigenschaften können auch die optischen Eigen-schaften des Polyanilins zur pH-Detektion herangezogen werden. Diese wurden zunächst mit Hilfe der UV-VIS-Spektroskopie untersucht. Die erhaltenen Spektren werden gezeigt und kurz diskutiert. Mit Hilfe eines Raster-Sonden-Mikroskops (a-SNOM, Firma WITec) wurden Reflexionsmessungen an Polyanilinschichten durchgeführt. Zur weiteren Miniaturisierung wurden Siliziumdioxidhohlpyramiden (Basisfläche 400 µm2) mit Spitzenöffnungen in einem Bereich von 50-150 nm mit Polyanilin beschichtet. Auch hier sollten die optischen Eigenschaften des Polyanilins zur pH-Wert-Sensorik ausgenutzt werden. Es werden erste Messungen an diesen Strukturen in Transmission diskutiert.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Intrinsisch leitfähige Polymere sind durch eine Reihe materialspezifischer Eigenschaften gekennzeichnet. In Abhängigkeit des angelegten Potenzials und der chemischen Umgebung zeigen sie elektrochromes Verhalten, Veränderungen der Masse, des Volumens und der elektronischen Leitfähigkeit. Basierend auf diesen Eigenschaften eignen sich halbleitende organische Polymere als funktionales Material für Anwendungen in der Mikro- und Nanotechnologie, insbesondere für miniaturisierte chemische Sensoren und Aktoren. Im Gegensatz zu konventionellen Piezo-Aktoren operieren diese Aktoren z. B. bei Spannungen unterhalb 1 V. Diese Arbeit befasst sich mit den elektrochemomechanischen Eigenschaften der ausgewählten Polymere Polyanilin und Polypyrrol, d. h. mit den potenzialkontrollierten Veränderungen des Volumens, der Struktur und der mechanischen Eigenschaften. Bei diesem Prozess werden positive Ladungen innerhalb der Polymerphase generiert. Um die für den Ladungsausgleich benötigten Gegenionen bereitzustellen, werden alle Messungen in Anwesenheit eines wässrigen Elektrolyten durchgeführt. Der Ladungstransport und die Volumenänderungen werden mit den Methoden der zyklischen Voltammetrie, der elektrochemischen Quarzmikrowaage und der Rastersondenmikroskopie untersucht. Signifikante Ergebnisse können für dünne homogene Polymerschichten erhalten werden, wobei Schichtdicken oberhalb 150 nm aufgrund der insbesondere bei Polyanilin einsetzenden Bildung von Fadenstrukturen (Fibrillen) vermieden werden. Von besonderem Interesse im Rahmen dieser Arbeit ist die Kombination der funktionalen Polymere mit Strukturen auf Siliziumbasis, insbesondere mit mikrostrukturierten Cantilevern. Die zuvor erhaltenen Ergebnisse bilden die Grundlage für das Design und die Dimensionierung der Mikroaktoren. Diese bestehen aus Siliziumcantilevern, die eine Elektrodenschicht aus Gold oder Platin tragen. Auf der Elektrode wird mittels Elektrodeposition eine homogene Schicht Polymer mit Schichtdicken bis zu 150 nm aufgebracht. Die Aktorcharakteristik, die Biegung des Cantilevers aufgrund des angelegten Potenzials, wird mit dem aus der Rastersondenmikroskopie bekannten Lichtzeigerverfahren gemessen. Das Aktorsystem wird hinsichtlich des angelegten Potenzials, des Elektrolyten und der Redox-Kinetik charakterisiert. Die verschiedenen Beiträge zum Aktorverhalten werden in situ während des Schichtwachstums untersucht. Das beobachtete Verhalten kann als Superposition verschiedener Effekte beschrieben werden. Darunter sind die Elektrodenaufladung (Elektrokapillarität), die Veränderungen der Elektrodenoberfläche durch dünne Oxidschichten und die Elektrochemomechanik des Polymers.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Electrospun fibres based on polypyrrole have been prepared. The incorporation of preformed polypyrrole into fibres electrospun from a carrier polymer can only be achieved when materials are prepared with particulates smaller than the cross-section of the fibre; even so there are some problems, with the substantial loss of material from the electrode tip. As an alternative approach, soluble polypyrroles can be prepared but these are not of sufficient viscosity to prepare electrospun fibres, once again a carrier polymer must be employed. More effective loadings are gained by the process of coating the outer surface of a pre-spun fibre; in this way electrospun fibres coated with polypyrrole can be prepared. This approach has been adapted to produce silver coated polymer fibres by the use of copolymers of styrene and 3-vinyl benzaldehyde.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The acute hippocampal brain slice preparation is an important in vitro screening tool for potential anticonvulsants. Application of 4-aminopyridine (4-AP) or removal of external Mg2+ ions induces epileptiform bursting in slices which is analogous to electrical brain activity seen in status epilepticus states. We have developed these epileptiform models for use with multi-electrode arrays (MEAs), allowing recording across the hippocampal slice surface from 59 points. We present validation of this novel approach and analyses using two anticonvulsants, felbamate and phenobarbital, the effects of which have already been assessed in these models using conventional extracellular recordings. In addition to assessing drug effects on commonly described parameters (duration, amplitude and frequency), we describe novel methods using the MEA to assess burst propagation speeds and the underlying frequencies that contribute to the epileptiform activity seen. Contour plots are also used as a method of illustrating burst activity. Finally, we describe hitherto unreported properties of epileptiform bursting induced by 100M4-AP or removal of external Mg2+ ions. Specifically, we observed decreases over time in burst amplitude and increase over time in burst frequency in the absence of additional pharmacological interventions. These MEA methods enhance the depth, quality and range of data that can be derived from the hippocampal slice preparation compared to conventional extracellular recordings. It may also uncover additional modes of action that contribute to anti-epileptiform drug effects