999 resultados para Bio metric modes


Relevância:

20.00% 20.00%

Publicador:

Resumo:

This paper proposes to promote autonomy in digital ecosystems so that it provides agents with information to improve the behavior of the digital ecosystem in terms of stability. This work proposes that, in digital ecosystems, autonomous agents can provide fundamental services and information. The final goal is to run the ecosystem, generate novel conditions and let agents exploit them. A set of evaluation measures must be defined as well. We want to provide an outline of some global indicators, such as heterogeneity and diversity, and establish relationships between agent behavior and these global indicators to fully understand interactions between agents, and to understand the dependence and autonomy relations that emerge between the interacting agents. Individual variations, interaction dependencies, and environmental factors are determinants of autonomy that would be considered. The paper concludes with a discussion of situations when autonomy is a milestone

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Microtubules are long, filamentous protein complexes which play a central role in several cellular physiological processes, such as cell division transport and locomotion. Their mechanical properties are extremely important since they determine the biological function. In a recently published experiment [Phys. Rev. Lett. 89 (2002) 248101], microtubule's Young's and shear moduli were simultaneously measured, proving that they are highly anisotropic. Together with the known structure, this finding opens the way to better understand and predict their mechanical behavior under a particular set of conditions. In the present study, we modeled microtubules by using the finite elements method and analyzed their oscillation modes. The analysis revealed that oscillation modes involving a change in the diameter of the microtubules strongly depend on the shear modulus. In these modes, the correlation times of the movements are just slightly shorter than diffusion times of free molecules surrounding the microtubule. It could be therefore speculated that the matching of the two timescales could play a role in facilitating the interactions between microtubules and MT associated proteins, and between microtubules and tubulins themselves.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Introduction: The use of bioabsorbable materials for orthopaedic useand traumatic fracture fixation in children has been poorly investigatedin the litterature and the effects on growing bones seem contradictory.The aim of the study is to compare the clinical and radiological resultsand evolution between bioabsorbable and traditional K-Wires for thetreatment of elbow epiphyseal fractures in children.Method: From jan. 2008 to Dec. 2009 21 children with similar fracturesand age were separated in two groups according to the way of fracturefixation: bioabsorbable K-Wire group and traditional K-Wire group.Follow-up was done at 3, 6 and 12 month post-operatively. Range ofmotion and elbow stability were measured for all patients. Theradiological evolution of the two groups were compared in term ofconsolidation, ossous resorption and radiolucencies. The clinicalresults were compared according to the Mayo Elbow Peformancescore. Controlateral elbow is compared with injured elbow in the twogroups.Results: In the bioabsorbable K-wire group, there were 10 children,including 5 girles and 5 boys with an average age of 9.5 years, rangingfrom 5 to 14 years. They were 7 external condylar fractures and3 epitrochlear fractures. In the traditional K-Wire group there were11 children, 2 girls and 9 boys with an average age of 7.6 years,ranging from 4 to 14 years. There were 10 external condylar fracturesand 1 epitrochlear fracture. At first follow up. The Mayo ElbowPerformance score was 93.8 (85-100 )for the bioabsorbable K-Wiregroup and 95.5 (85-100) for the traditional K-Wire group. In twochildren from the bioabsorbable K-Wire group there were transitoryradiolucencies along the wire tract on the x-ray, without clinicalmanifestation of it.We didn't see any premature closure of growingcartilage.Discussion: There is no significant differencies in term of clinical andradiological outcome between the two groups. The use ofbioabsorbable pins seems to be a good alternative to removabletraditional materials, avoiding a second operation.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The definition of sarcopenia includes both a loss of muscle strength and a decline in functional quality in addition to the loss of muscle protein mass. Multispectral bioimpendance allows bedside assessment of muscle mass. Using this new tool, we performed a pilot study to look for a possible correlation between muscle mass and various tests of muscle strength (grip strength, key-pitch, tip-pinch) and with functional tests (walk speed on 10 meters and Tinetti test). Our study demonstrates a good correlation between muscle mass determined by spectroscopic bioimpendance and muscle strength assessment, but no correlation with functional tests.