325 resultados para Arthroplasty
Resumo:
The standard Exeter stem has a length of 150mm with offsets 37.5mm to 56mm. Shorter stems of lengths 95mm, 115mm and 125mm with offsets 35.5mm or less are available for patients with smaller femurs. Concern has been raised regarding the behaviour of the smaller implants. This paper analysed data from the Australian Orthopaedic Association National Joint Replacement Registry comparing survivorship of stems of offset 35.5mm or less with the standard stems of 37.5mm offset or greater. At seven years there was no significant difference in the Cumulative Percent Revision Rate in the short stems (3.4%, 95% CI 2.4-4.8%) compared with the standard length stems (3.5%, 95% CI 3.3-3.8%) despite its use in a greater proportion of potentially more difficult developmental dysplasia of the hip cases.
Resumo:
The technique of femoral cement-in-cement revision is well established, but there are no previous series reporting its use on the acetabular side at the time of revision total hip arthroplasty. We describe the surgical technique and report the outcome of 60 consecutive cement-in-cement revisions of the acetabular component at a mean follow-up of 8.5 years (range 5-12 years). All had a radiologically and clinically well fixed acetabular cement mantle at the time of revision. 29 patients died. No case was lost to follow-up. The 2 most common indications for acetabular revision were recurrent dislocation (77%) and to compliment a femoral revision (20%). There were 2 cases of aseptic cup loosening (3.3%) requiring re-revision. No other hip was clinically or radiologically loose (96.7%) at latest follow-up. One case was re-revised for infection, 4 for recurrent dislocation and 1 for disarticulation of a constrained component. At 5 years, the Kaplan-Meier survival rate was 100% for aseptic loosening and 92.2% (95% CI; 84.8-99.6%) with revision for all causes as the endpoint. These results support the use of the cement-in-cement revision technique in appropriate cases on the acetabular side. Theoretical advantages include preservation of bone stock, reduced operating time, reduced risk of complications and durable fixation.
Resumo:
Purpose. To compare radiological records of 90 consecutive patients who underwent cemented total hip arthroplasty (THA) with or without use of the Rim Cutter to prepare the acetabulum. Methods. The acetabulum of 45 patients was prepared using the Rim Cutter, whereas the device was not used in the other 45 patients. Postoperative radiographs were evaluated using a digital templating system to measure (1) the positions of the operated hips with respect to the normal, contralateral hips (the centre of rotation of the socket, the height of the centre of rotation from the teardrop, and lateralisation of the centre of rotation from the teardrop) and (2) the uniformity and width of the cement mantle in the 3 DeLee Charnley acetabular zones, and the number of radiolucencies in these zones. Results. The study group showed improved radiological parameters and were closer to the anatomic centre of rotation both vertically (1.5 vs. 3.7 mm, p<0.001) and horizontally (1.8 vs. 4.4 mm, p<0.001) and had consistently thicker and more uniform cement mantles (p<0.001). There were 2 radiolucent lines in the control group but none in the study group. Conclusion. The Rim Cutter resulted in more accurate placement of the centre of rotation of a cemented prosthetic socket, and produced a thicker, more congruent cement mantle with fewer radiolucent lines.
Resumo:
The aim of this study was to perform a biomechanical analysis of the cement-in-cement (c-in-c) technique for fixation of selected Vancouver Type B1 femoral periprosthetic fractures and to assess the degree of cement interposition at the fracture site. Six embalmed cadaveric femora were implanted with a cemented femoral stem. Vancouver Type B1 fractures were created by applying a combined axial and rotational load to failure. The femora were repaired using the c-in-c technique and reloaded to failure. The mean primary fracture torque was 117 Nm (SD 16.6, range 89–133). The mean revision fracture torque was 50 Nm (SD 16.6, range 29–74), which is above the torque previously observed for activities of daily living. Cement interposition at the fracture site was found to be minimal.
Resumo:
Between 1995 and 2003, 129 cemented primary THRs were performed using full acetabular impaction grafting to reconstruct acetabular deficiencies. These were classified as cavitary in 74 and segmental in 55 hips. Eighty-one patients were reviewed at mean 9.1 (6.2-14.3) years post-operatively. There were seven acetabular component revisions due to aseptic loosening, and a further 11 cases that had migrated >5mm or tilted >5° on radiological review - ten of which reported no symptoms. Kaplan-Meier analysis of revisions for aseptic loosening demonstrates 100% survival at nine years for cavitary defects compared to 82.6% for segmental defects. Our results suggest that the medium-term survival of this technique is excellent when used for purely cavitary defects but less predictable when used with large rim meshes in segmental defects.
Resumo:
The relationship between coronal knee laxity and the restraining properties of the collateral ligaments remains unknown. This study investigated correlations between the structural properties of the collateral ligaments and stress angles used in computer-assisted total knee arthroplasty (TKA), measured with an optically based navigation system. Ten fresh-frozen cadaveric knees (mean age: 81 ± 11 years) were dissected to leave the menisci, cruciate ligaments, posterior joint capsule and collateral ligaments. The resected femur and tibia were rigidly secured within a test system which permitted kinematic registration of the knee using a commercially available image-free navigation system. Frontal plane knee alignment and varus-valgus stress angles were acquired. The force applied during varus-valgus testing was quantified. Medial and lateral bone-collateral ligament-bone specimens were then prepared, mounted within a uni-axial materials testing machine, and extended to failure. Force and displacement data were used to calculate the principal structural properties of the ligaments. The mean varus laxity was 4 ± 1° and the mean valgus laxity was 4 ± 2°. The corresponding mean manual force applied was 10 ± 3 N and 11 ± 4 N, respectively. While measures of knee laxity were independent of the ultimate tensile strength and stiffness of the collateral ligaments, there was a significant correlation between the force applied during stress testing and the instantaneous stiffness of the medial (r = 0.91, p = 0.001) and lateral (r = 0.68, p = 0.04) collateral ligaments. These findings suggest that clinicians may perceive a rate of change of ligament stiffness as the end-point during assessment of collateral knee laxity.
Resumo:
Impaction bone grafting for reconstitution of bone stock in revision hip surgery has been used for nearly 30 years. We used this technique, in combination with a cemented acetabular component, in the acetabula of 304 hips in 292 patients revised for aseptic loosening between 1995 and 2001. The only additional supports used were stainless steel meshes placed against the medial wall or laterally around the acetabular rim to contain the graft. All Paprosky grades of defect were included. Clinical and radiographic outcomes were collected in surviving patients at a minimum of 10 years following the index operation. Mean follow-up was 12.4 years (SD 1.5; range 10.0-16.0). Kaplan-Meier survivorship with revision for aseptic loosening as the endpoint was 85.9% (95% CI 81.0 to 90.8%) at 13.5 years. Clinical scores for pain relief remained satisfactory, and there was no difference in clinical scores between cups that appeared stable and those that appeared loose radiographically.
Resumo:
In an attempt to preserve proximal femoral bone stock and achieve a better fit in smaller femora, especially in the Asian population, several new shorter stem designs have become available. We investigated the torque to periprosthetic femoral fracture of the Exeter short stem compared with the conventional length Exeter stem in a Sawbone model. 42 stems; 21 shorter and 21 conventional stems both with three different offsets were cemented in a composite Sawbone model and torqued to fracture. Results showed that Sawbone femurs break at a statistically significantly lower torque to failure with a shorter compared to conventional length Exeter stem of the same offset. Both standard and short stem designs are safe to use as the torque to failure is 7-10 times that seen in activities of daily living.
Resumo:
Mortality following hip arthroplasty is affected by a large number of confounding variables each of which must be considered to enable valid interpretation. Relevant variables available from the 2011 NJR data set were included in the Cox model. Mortality rates in hip arthroplasty patients were lower than in the age-matched population across all hip types. Age at surgery, ASA grade, diagnosis, gender, provider type, hip type and lead surgeon grade all had a significant effect on mortality. Schemper's statistic showed that only 18.98% of the variation in mortality was explained by the variables available in the NJR data set. It is inappropriate to use NJR data to study an outcome affected by a multitude of confounding variables when these cannot be adequately accounted for in the available data set.
Resumo:
Background and purpose Non-traumatic osteonecrosis is a progressive disease with multiple etiologies. It affects younger individuals more and more, often leading to total hip arthroplasty. We investigated whether there is a correlation between inducible nitric oxide synthase (iNOS) expression and osteocyte apoptosis in non-traumatic osteonecrosis. Patients and methods We collected and studied 20 human idiopathic, non-traumatic osteonecrosis femoral heads. Subchondral bone samples in the non-sclerotic region (n = 30), collected from osteoarthritis patients, were used as controls. Spontaneously hypertensive rats were used as a model for osteonecrosis in the study. We used scanning electron microscopy, TUNEL assay, and immunohistochemical staining to study osteocyte changes and apoptosis. Results The morphology of osteocytes in the areas close to the necrotic region changed and the number of apoptotic osteocytes increased in comparison with the same region in control groups. The expression of iNOS and cytochrome C in osteocytes increased while Bax expression was not detectable in osteonecrosis samples. Using spontaneously hypertensive rats, we found a positive correlation between iNOS expression and osteocyte apoptosis in the osteonecrotic region. iNOS inhibitor (aminoguanidine) added to the drinking water for 5 weeks reduced the production of iNOS and osteonecrosis compared to a control group without aminoguanidine. Interpretation Our findings show that increased iNOS expression can lead to osteocyte apopotosis in idiopathic, non-traumatic osteonecrosis and that an iNOS inhibitor may prevent the progression of the disease.
Resumo:
Introduction The risk for late periprosthetic fractures is higher in patients treated for a neck of femur fracture compared to those treated for osteoarthritis. It has been hypothesised that osteopenia and consequent decreased stiffness of the proximal femur are responsible for this. We investigated if a femoral component with a bigger body would increase the torque to failure in a biaxially loaded composite sawbone model. Method A biomechanical composite sawbone model was used. Two different body sizes (Exeter 44-1 vs 44-4) of a polished tapered cemented stem were implanted by an experienced surgeon, in 7 sawbones each and loaded at 40 deg/s internal rotation until failure. Torque to fracture and fracture energy were measured using a biaxial materials testing device (Instron 8874). Data are non-parametric and tested with Mann-Whitney U-test. Results The mean torque load to fracture was 154.1 NM (SD 4.4) for the 44-1 stem and 229 NM (SD10.9) for the 44-4 stem (p = 0.01). The mean fracture energy was 9.6 J (SD1.2) for the 44-1 stem and 17.2 J (SD2.0) for the 44-4 stem (p = 0.14). Conclusion the use of a large body polished tapered cemented stem for neck of femur fractures increases the torque to failure in a biomechanical model and therefore is likely to reduce late periprosthetic fracture risk in this vulnerable cohort.
In-hospital mortality rates after a cemented femoral component for displaced neck of femur fractures
Resumo:
Aim This prospective cohort study investigated whether the use of preoperative anticoagulants is an independent risk factor for the outcomes of surgical treatment of patients with a neck of femur fracture. Methods Data was obtained from a prospectively collected database. All patients admitted for a neck of femur fracture between Nov 2010 and Oct 2011 were included. This resulted in three hundred twenty-eight patients with 330 neck of femur fractures. Four groups were defined; patients preoperatively (i) on aspirin (n = 105); (ii) on clopidogrel (n = 28); (iii) on warfarin (n = 30), and; (iv) without any anticoagulation history (n = 167, the control group). The non-warfarin group included the aspirin group, clopidogrel group and the control group. Primary outcome was the in-hospital mortality. Secondary outcomes were the postoperative complications, return to theatre and length of stay. Results Thirteen in-hospital deaths were identified, 4 deaths in the aspirin group, 1 death in the clopidogrel group, 2 deaths in the warfarin group and 6 deaths in the control group. No significant difference in the mortality rates was found between the different groups. Also in the secondary outcomes, no significant difference was found between the four groups. A trend to a higher wound complication rate for the warfarin group was detected. Conclusion The use of clopidrogel or aspirin pre operatively is not an influence on short term patient outcome for patients with a neck of femur fracture. Surgical procedures should not be delayed to reverse their influence.
Resumo:
PURPOSE: To compare pressures generated by 2 different cement pressurisers at various locations in the proximal femur. METHODS: Two groups of 5 synthetic femurs were used, and 6 pressure sensors were placed in the femur at 20-mm intervals proximally to distally. Cement was filled into the femoral canal retrogradely using a cement gun with either the half-moon pressuriser or the femoral canal pressuriser. Maximum pressures and pressure time integrals (cumulative pressure over time) of the 2 pressurisers were compared. RESULTS: At all sensors, the half-moon pressuriser produced higher maximum pressures and pressure time integrals than the femoral canal pressuriser, but the difference was significant only at sensor 1 (proximal femur). This may result in reduced cement interdigitation in the proximal femur. CONCLUSION: The half-moon pressuriser produced higher maximum cementation pressures and pressure time integrals than the femoral canal pressuriser in the proximal femur region, which is critical for rotational stability of the implant and prevention of implant fracture. KEYWORDS: arthroplasty, replacement, hip; bone cements; femur
Resumo:
Aims: The aims of this study were 1) to identify and describe health economic studies that have used quality-adjusted life years (QALYs) based on actual measurements of patients' health-related quality of life (HRQoL); 2) to test the feasibility of routine collection of health-related quality of life (HRQoL) data as an indicator of effectiveness of secondary health care; and 3) to establish and compare the cost-utility of three large-volume surgical procedures in a real-world setting in the Helsinki University Central Hospital, a large referral hospital providing secondary and tertiary health-care services for a population of approximately 1.4 million. Patients and methods: So as to identify studies that have used QALYs as an outcome measure, a systematic search of the literature was performed using the Medline, Embase, CINAHL, SCI and Cochrane Library electronic databases. Initial screening of the identified articles involved two reviewers independently reading the abstracts; the full-text articles were also evaluated independently by two reviewers, with a third reviewer used in cases where the two reviewers could not agree a consensus on which articles should be included. The feasibility of routinely evaluating the cost-effectiveness of secondary health care was tested by setting up a system for collecting HRQoL data on approximately 4 900 patients' HRQoL before and after operative treatments performed in the hospital. The HRQoL data used as an indicator of treatment effectiveness was combined with diagnostic and financial indicators routinely collected in the hospital. To compare the cost-effectiveness of three surgical interventions, 712 patients admitted for routine operative treatment completed the 15D HRQoL questionnaire before and also 3-12 months after the operation. QALYs were calculated using the obtained utility data and expected remaining life years of the patients. Direct hospital costs were obtained from the clinical patient administration database of the hospital and a cost-utility analysis was performed from the perspective of the provider of secondary health care services. Main results: The systematic review (Study I) showed that although QALYs gained are considered an important measure of the effectiveness of health care, the number of studies in which QALYs are based on actual measurements of patients' HRQoL is still fairly limited. Of the reviewed full-text articles, only 70 reported QALYs based on actual before after measurements using a valid HRQoL instrument. Collection of simple cost-effectiveness data in secondary health care is feasible and could easily be expanded and performed on a routine basis (Study II). It allows meaningful comparisons between various treatments and provides a means for allocating limited health care resources. The cost per QALY gained was 2 770 for cervical operations and 1 740 for lumbar operations. In cases where surgery was delayed the cost per QALY was doubled (Study III). The cost per QALY ranges between subgroups in cataract surgery (Study IV). The cost per QALY gained was 5 130 for patients having both eyes operated on and 8 210 for patients with only one eye operated on during the 6-month follow-up. In patients whose first eye had been operated on previous to the study period, the mean HRQoL deteriorated after surgery, thus precluding the establishment of the cost per QALY. In arthroplasty patients (Study V) the mean cost per QALY gained in a one-year period was 6 710 for primary hip replacement, 52 270 for revision hip replacement, and 14 000 for primary knee replacement. Conclusions: Although the importance of cost-utility analyses has during recent years been stressed, there are only a limited number of studies in which the evaluation is based on patients own assessment of the treatment effectiveness. Most of the cost-effectiveness and cost-utility analyses are based on modeling that employs expert opinion regarding the outcome of treatment, not on patient-derived assessments. Routine collection of effectiveness information from patients entering treatment in secondary health care turned out to be easy enough and did not, for instance, require additional personnel on the wards in which the study was executed. The mean patient response rate was more than 70 %, suggesting that patients were happy to participate and appreciated the fact that the hospital showed an interest in their well-being even after the actual treatment episode had ended. Spinal surgery leads to a statistically significant and clinically important improvement in HRQoL. The cost per QALY gained was reasonable, at less than half of that observed for instance for hip replacement surgery. However, prolonged waiting for an operation approximately doubled the cost per QALY gained from the surgical intervention. The mean utility gain following routine cataract surgery in a real world setting was relatively small and confined mostly to patients who had had both eyes operated on. The cost of cataract surgery per QALY gained was higher than previously reported and was associated with considerable degree of uncertainty. Hip and knee replacement both improve HRQoL. The cost per QALY gained from knee replacement is two-fold compared to hip replacement. Cost-utility results from the three studied specialties showed that there is great variation in the cost-utility of surgical interventions performed in a real-world setting even when only common, widely accepted interventions are considered. However, the cost per QALY of all the studied interventions, except for revision hip arthroplasty, was well below 50 000, this figure being sometimes cited in the literature as a threshold level for the cost-effectiveness of an intervention. Based on the present study it may be concluded that routine evaluation of the cost-utility of secondary health care is feasible and produces information essential for a rational and balanced allocation of scarce health care resources.