992 resultados para Antigen detection


Relevância:

30.00% 30.00%

Publicador:

Resumo:

An increasing amount of research has been conducted on immunoglobulin Y (IgY) because the use of IgY offers several advantages with respect to diagnostic testing, including its easy accessibility, low cost and translatability to large-scale production, in addition to the fact that it can be ethically produced. In a previous work, immunoglobulin was produced and purified from egg yolks (IgY) reactive to hepatitis A virus (HAV) antigens. In the present work, this anti-HAV-specific IgY was used in an indirect immunofluorescence assay to detect viral antigens in liver biopsies that were obtained from experimentally infected cynomolgus monkeys. Fields that were positive for HAV antigen were detected in liver sections using confocal microscopy. In conclusion, egg yolks from immunised hens may be a reliable source for antibody production, which can be employed for immunological studies.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

As part of an ongoing effort to improve the technique of immunoscintigraphy for the detection of human carcinomas with radiolabeled monoclonal antibodies (MABs) to carcinoembryonic antigen (CEA), we have developed a series of MABs to CEA and have studied the effects of low- and physiological molarity buffers on their CEA binding and affinity, as well as their cross-reactivity with granulocyte glycoprotein(s). These in vitro results in different buffer systems were then correlated with the use of these MABs to CEA in the detection of human colon carcinoma grafts in nude mice. Our results show that the binding of CEA by some MABs is influenced by ionic strength and that this may be an important factor in their successful use for the immunolocalization of carcinomas in vivo.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

A solid-phase enzyme immunoassay using both mouse monoclonal and goat polyclonal antibodies against carcinoembryonic antigen (CEA) was developed. The assay detects 0.6 to 1.2 ng of CEA per ml of serum and has 3 incubation steps which can be performed in 1 day. Polystyrene balls coated with polyclonal goat anti-CEA antibodies are first incubated with heat-extracted serum samples. Bound CEA is then detected by addition of mouse monoclonal antibodies, followed by goat IgG anti-mouse IgG1 coupled to alkaline phosphatase. Results with this enzyme immunoassay using monoclonal antibodies (M-EIA) have been compared with those obtained by the conventional inhibition radioimmunoassay (RIA) using goat antiserum. Three hundred and eighty serum samples from 167 patients with malignant or non-malignant diseases and from 134 normal individuals with or without heavy smoking habits were analyzed by the 2 assays. Excellent correlation between the results of the 2 assays was obtained, but the M-EIA, using monoclonal antibodies from a single hybridoma, did not discriminate better than the conventional RIA between CEA produced by different types of carcinoma and between CEA associated with malignant or non-malignant diseases. Follow-up studies of several patients by sequential CEA determinations with the 2 assays showed that the M-EIA was as accurate as the RIA for the detection of tumor recurrences.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Education and diagnostic tests capable of early detection represent our most effective means of preventing transmission of human immunodeficiency virus (HIV). The importance of early detection is underlined by studies demonstrating increased life expectancy following early initiation of antiviral treatment. The Elecsys(®) HIV combi PT assay is a fourth-generation antigen-antibody combination assay developed to allow earlier detection of seroconversion, and to have increased sensitivity and improved specificity. We aimed to determine how early the assay could detect infection compared with existing assays; whether all HIV variants could be detected; and the assay's specificity using samples from blood donors, routine specimens, and patients with potential cross-reacting factors. Samples were identified as positive by the Elecsys(®) assay 4.9 days after a positive polymerase chain reaction result (as determined by the panel supplier), which was earlier than the 5.3-7.1 days observed with comparators. The analytical sensitivity of the Elecsys(®) HIV combi PT assay for the HIV-1 p24 antigen was 1.05 IU/mL, which compares favorably with the comparator assays. In addition, the Elecsys(®) assay identified all screened HIV subtypes and displayed greater sensitivity to HIV-2 homologous antigen and antibodies to HIV-1 E and O and HIV-2 than the other assays. Overall, the specificity of the Elecsys(®) assay was 99.88 % using samples from blood donors and 99.81 % when analyzing unselected samples. Potential cross-reacting factors did not interfere with assay performance. The Elecsys(®) HIV combi PT assay is a sensitive and specific assay that has been granted the CE mark according to Directive 2009/886/EC.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Paul Ehrlich's inspired concept of 'magic bullets' for the cure of diseases has been revitalized by recent advances in immunology1. In particular, the development of cell fusion technology allowing the production of monoclonal antibodies (Mabs) with exquisite specificities2 triggered new hopes that we may now have the perfect carrier molecules with which to deliver cytotoxic drugs3 or toxins4 to the hidden cancer cells. This article reviews data on one aspect of the magic bullet concept, the use of radiolabelled antibodies as tracers for tumour localization. It will also discuss the very recent clinical use of 131I-labelled Mabs against carcinoembryonic antigen (CEA)5 to detect carcinoma either by conventional external photoscanning or by single photon emission computerized tomography (SPELT). This alliance of the most modern tools from immunology (Mabs) and nuclear medicine (SPELT) appears promising as a way to improve the sensitivity of 'immunoscintigraphy'. However, this approach is not yet ready, for widespread clinical use.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Expression of the cancer/germ-line antigen NY-ESO-1 by tumors elicits spontaneous humoral and cellular immune responses in some cancer patients. Development of vaccines capable of stimulating such comprehensive immune responses is desirable. We have produced recombinant lentivectors directing the intracellular synthesis of NY-ESO-1 (rLV/ESO) and have analyzed the in vivo immune response elicited by this vector. Single injection of rLV/ESO into HLA-A2-transgenic mice elicited long-lasting B and T cell responses against NY-ESO-1. CD8+ T cells against the HLA-A2-restricted peptide NY-ESO-1(157-165) were readily detectable ex vivo and showed restricted TCR Vbeta usage. Moreover, rLV/ESO elicited a far greater anti-NY-ESO-1(157-165) CD8+ T cell response than peptide- or protein-based vaccines. Anti-NY-ESO-1 antibodies were rapidly induced after immunization and their detection preceded that of the antigen-specific CD8+ T cells. The rLV/ESO also induced CD4+ T cells. These cells played an essential role as their depletion completely abrogated B cell and CD8+ T cell responses against NY-ESO-1. The induced CD4+ T cells were primarily directed against a single NY-ESO-1 epitope spanning amino acids 81-100. Altogether, our study shows that rLV/ESO induces potent and comprehensive immune responses in vivo.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Effective treatment of ovarian cancer depends upon the early detection of the malignancy. Here, we report on the development of a new nanostructured immunosensor for early detection of cancer antigen 125 (CA-125). A gold electrode was modified with mercaptopropionic acid (MPA), and then consecutively conjugated with silica coated gold nanoparticles (AuNP@SiO2), CdSe quantum dots (QDs) and anti-CA-125 monoclonal antibody (mAb). The engineered MPA|AuNP@SiO2|QD|mAb immunosensor was characterised using transmission electron microscopy (TEM), atomic force microscopy (AFM), cyclic voltammetry (CV) and electrochemical impedance spectroscopy (EIS). Successive conjugation of AuNP@SiO2, CdSe QD and anti-CA-125 mAb onto the gold electrode resulted in sensitive detection of CA-125 with a limit of detection (LOD) of 0.0016 U mL(-1) and a linear detection range (LDR) of 0-0.1 U mL(-1). Based on the high sensitivity and specificity of the immunosensor, we propose this highly stable and reproducible biosensor for the early detection of CA-125.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

In 2009, the American Cancer Society (ACS) Prostate Cancer Advisory Committee began the process of a complete update of recommendations for early prostate cancer detection. A series of systematic evidence reviews was conducted focusing on evidence related to the early detection of prostate cancer, test performance, harms of therapy for localized prostate cancer, and shared and informed decision making in prostate cancer screening. The results of the systematic reviews were evaluated by the ACS Prostate Cancer Advisory Committee, and deliberations about the evidence occurred at committee meetings and during conference calls. On the basis of the evidence and a consensus process, the Prostate Cancer Advisory Committee developed the guideline, and a writing committee drafted a guideline document that was circulated to the entire committee for review and revision. The document was then circulated to peer reviewers for feedback, and finally to the ACS Mission Outcomes Committee and the ACS Board of Directors for approval. The ACS recommends that asymptomatic men who have at least a 10-year life expectancy have an opportunity to make an informed decision with their health care provider about screening for prostate cancer after they receive information about the uncertainties, risks, and potential benefits associated with prostate cancer screening. Prostate cancer screening should not occur without an informed decision-making process. Men at average risk should receive this information beginning at age 50 years. Men in higher risk groups should receive this information before age 50 years. Men should either receive this information directly from their health care providers or be referred to reliable and culturally appropriate sources. Patient decision aids are helpful in preparing men to make a decision whether to be tested.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Purified monoclonal antibodies (Mab) produced by 3 hybridomas and reacting with 3 different epitopes of carcinoembryonic antigen (CEA) were used in a solid phase enzyme immunoassay. Two Mabs were physically adsorbed to polystyrene balls and the third Mab was coupled to alkaline phosphatase using the bifunctional reagent N-succinimidyl-3-(2-pyridyldithio)-propionate. During a first incubation, CEA from heat-extracted serum samples was immunoadsorbed to the antibody coated balls. After washing of the balls, bound CEA was detected by a second incubation with the enzyme coupled Mab. The sensitivity of the assay was 0.6 ng per ml of serum. A total of 196 serum samples from patients with various types of carcinoma, with liver cirrhosis, or from healthy blood donors with or without smoking habits, were tested. The results obtained with the monoclonal enzyme immunoassay (M-EIA) were compared with those obtained with perchloric acid extracts of the same serum samples tested by an inhibition radioimmunoassay using conventional goat anti-CEA antiserum. There was an excellent correlation between the two assays. In particular, the new M-EIA gave good results for the detection of tumor recurrences in the follow-up of colon carcinoma patients. However, despite the use of exclusively monoclonal antibodies the new assay detected a similar percentage of slightly elevated CEA values as the conventional assay in patients with non-malignant disease, suggesting that the CEA associated with non-malignant diseases is immunologically identical to the CEA released by colon carcinoma.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

To avoid the exclusive use of rodent monoclonal antibodies (MAbs) in patients for the detection of tumors by immunoscintigraphy and for radioimmunotherapy, swine MAbs were produced that are directed against carcinoembryonic antigen (CEA). Spleen cells from 2 pigs immunized with purified colon carcinoma CEA were fused with a nonsecreting mouse myeloma cell line by conventional methods, except that a particularly long immunization protocol and large amounts of spleen and myeloma cells were used. Of 1,200 growing hybrids tested, 20 were found initially to produce antibodies binding to radiolabeled CEA. Seven stable clones producing anti-CEA MAbs for more than 6 months were derived from these hybrids by repeated subcloning. The pig origin of the seven MAbs was demonstrated in a solid-phase CEA enzyme immunoassay where anti-pig immunoglobin (Ig) antibodies coupled to peroxidase gave a positive reaction while anti-mouse Ig antibodies were entirely negative. All swine MAbs were of the IgG isotype. Three anti-CEA MAbs showed no cross-reactivity with granulocytes, while four others gave various degrees of reactivity with different granulocyte glycoproteins. Competitive binding to CEA performed for two purified swine MAbs showed that they recognized two different epitopes. The affinity constants measured for these two MAbs by Scatchard plot on purified CEA were high (1.2 X 10(9) and 1.2 X 10(10) liter/mol). One of the MAbs was tested in vivo for tumor localization by injection, after radiolabeling, in nude mice bearing human colon carcinoma xenograft. High ratios of tumor to normal tissue were obtained with mean values of 10.5 for intact MAbs and of 26.8 for F(ab')2 fragments of the porcine MAb. The results showed that heterofusion with this particular protocol can be used to produce swine MAbs of high affinity and specificity for a well-defined tumor marker. These reagents may have an important clinical utility, particularly in patients who became sensitized to mouse immunoglobulins.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Screening for Chlamydia trachomatis-specific antibodies is valuable in investigating recurrent miscarriage, tubal infertility and extrauterine pregnancy. We compared here the performance of immunofluorescence (IF) to four other commercial tests in detecting IgG antibodies directed against C. trachomatis: two enzyme-linked immunosorbent assays (ELISAs) using the major outer membrane protein (MOMP) as the antigen, commercialised respectively by Medac and R-Biopharm (RB), one ELISA using the chlamydial heat shock protein 60 (cHSP60) as the antigen (Medac), as well as a new automated epifluorescence immunoassay (InoDiag). A total of 405 patients with (n = 251) and without (n = 154) miscarriages were tested by all five tests. The prevalence of C. trachomatis-specific IgG antibodies as determined by the IF, cHSP60-Medac, MOMP-Medac, MOMP-RB and InoDiag was 14.3, 23.2, 14.3, 11.9 and 26.2%, respectively. InoDiag exhibited the highest sensitivity, whereas MOMP-RB showed the best specificity. Cross-reactivity was observed with C. pneumoniae using IF, MOMP-RB and InoDiag, and Parachlamydia acanthamoebae using the cHSP60 ELISA test. No cross-reactivity was observed between C. trachomatis and the other Chlamydiales (Neochlamydia hartmannellae, Waddlia chondrophila and Simkania negevensis). Given its high sensitivity, the new automated epifluorescence immunoassay from InoDiag represents an interesting alternative. The MOMP-based ELISA of R-Biopharm should be preferred for large serological studies, given the high throughput of ELISA and its excellent specificity.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Colorectal cancer frequently disseminates through the portal vein into the liver. In this study, outbred Swiss nude mice were adapted to facilitate the induction of liver metastases by a pre-grafting treatment with 6 Gy total body irradiation and i.v. injection of anti-asialo GM1 antibody. One day later, cultured LS 174T human colon cancer cells were injected into the surgically exposed spleen, which was resected 3 min later. In 48 of 65 mice, a few to several hundred liver metastases were macroscopically observed at dissection 3 to 4 weeks after transplantation. Ten of 10 mice, followed-up for survival, died with multiple large confluent liver metastases. By reducing the radiation dose to 4 or 0 Gy, or omitting the anti-asialo GM1 antibody injection, only 60%, 37% or 50% of mice, respectively, had visible metastases 3 weeks after transplantation. Carcinoembryonic antigen (CEA) measured in tumour extracts was in the mean 25.6 micrograms/g in liver metastases compared with 9.2 micrograms/g in s.c. tumours. Uptake of radiolabelled anti-CEA monoclonal antibody (MAb) in the metastases 12, 24 and 48 hr after injection gave a mean value of 39% of the injected dose per gram of tissue (ID/g). In comparison, MAb uptake in s.c. and intrasplenic tumours or lung metastases gave a mean percentage ID/g of 20, 18 and 15, respectively. Laser-induced fluorescence after injection of indocyanin-MAb conjugate allowed direct visual detection of small liver metastases, including some that were not visible under normal light. Preliminary results showed that mice, pre-treated with 4 Gy irradiation and the anti-asialo GM1 injection, were tolerant to radioimmunotherapy with a total dose of 500 muCi 131I labeled anti-CEA intact MAbs given in 3 injections.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Purified, [131I]-labeled goat antibodies against carcinoembryonic antigen, which have been shown to localize in human carcinoma in nude mice, were injected into 27 patients with carcinoma. Patients were scanned with a scintillation camera at various intervals. In 11 patients, radioactivity was detectable in the tumor 48 hours after injection. Computerized subtraction of blood-pool radioactivity provided clearer pictures in positive cases, but in 16 patients the scans remained doubtful or negative. To study the specificity of [131I]-antibody localization, we gave some patients simultaneous injections of [125I]-labeled normal IgG. Both isotopes were measured by means of scintillation counting in tumors and normal tissues recovered after surgery. The results demonstrated that only the anti-CEA antibodies localized in tumors. However, the total antibody-derived radioactivity in the tumor was only about 0.001 of the injected dose. We conclude that, despite the present demonstration of specificity, this method of tumor detection is not yet clinically useful.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

PURPOSE: Prostate cancer is the most commonly diagnosed cancer in the United States. The diagnosis or followup of prostate cancer in men older than 50 years is based on digital rectal examination, measurement of the free-to-total prostatic specific antigen ratio and transrectal ultrasound assisted needle biopsy of the prostate. We developed and evaluated a noninvasive method for diagnosing prostate cancer based on the measurement of telomerase activity after prostatic massage in fresh voided urine or after urethral washing. MATERIALS AND METHODS: We obtained 36 specimens of cells after prostatic massage in the fresh voided urine of 16 patients who subsequently underwent radical prostatectomy and after urethral washing in 20 who underwent prostate needle biopsies. Ethylenediaminetetraacetic acid was immediately added to the collected urine or washing to a final concentration of 20 mM. After protein extraction by CHAPS buffer each specimen was tested for telomerase activity in a 2-step modified telomeric repeat amplification protocol assay. The 2 prostate cancer cell lines PC-3 and LNCaP with high telomerase activity were used as a positive control. RESULTS: Telomerase activity was detected in 14 of 24 samples with known prostate cancer (sensitivity 58%). In contrast, no telomerase activity was found in the 12 cases without histological evidence of prostate tumor (specificity 100%). Eight of 9 poorly differentiated cancers expressed telomerase activity (89%), while only 6 of 15 well and moderately differentiated cancers showed telomerase activity (40%). CONCLUSIONS: Our data illustrate that telomerase activity may be detected in voided urine or washing after prostatic massage in patients with prostate cancer. Sensitivity was higher for poorly differentiated tumors. This approach is not currently available for detecting prostate cancer in clinical practice. However, these results are promising and further studies are ongoing.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

An important aspect of immune monitoring for vaccine development, clinical trials, and research is the detection, measurement, and comparison of antigen-specific T-cells from subject samples under different conditions. Antigen-specific T-cells compose a very small fraction of total T-cells. Developments in cytometry technology over the past five years have enabled the measurement of single-cells in a multivariate and high-throughput manner. This growth in both dimensionality and quantity of data continues to pose a challenge for effective identification and visualization of rare cell subsets, such as antigen-specific T-cells. Dimension reduction and feature extraction play pivotal role in both identifying and visualizing cell populations of interest in large, multi-dimensional cytometry datasets. However, the automated identification and visualization of rare, high-dimensional cell subsets remains challenging. Here we demonstrate how a systematic and integrated approach combining targeted feature extraction with dimension reduction can be used to identify and visualize biological differences in rare, antigen-specific cell populations. By using OpenCyto to perform semi-automated gating and features extraction of flow cytometry data, followed by dimensionality reduction with t-SNE we are able to identify polyfunctional subpopulations of antigen-specific T-cells and visualize treatment-specific differences between them.