308 resultados para Aneurysms


Relevância:

10.00% 10.00%

Publicador:

Resumo:

Purpose: Recently morphometric measurements of the ascending aorta have been done with ECG-gated MDCT to help the development of future endovascular therapies (TCT) [1]. However, the variability of these measurements remains unknown. It will be interesting to know the impact of CAD (computer aided diagnosis) with automated segmentation of the vessel and automatic measurements of diameter on the management of ascending aorta aneurysms. Methods and Materials: Thirty patients referred for ECG-gated CT thoracic angiography (64-row CT scanner) were evaluated. Measurements of the maximum and minimum ascending aorta diameters were obtained automatically with a commercially available CAD and semi-manually by two observers separately. The CAD algorithms segment the iv-enhanced lumen of the ascending aorta into perpendicular planes along the centreline. The CAD then determines the largest and the smallest diameters. Both observers repeated the automatic measurements and the semimanual measurements during a different session at least one month after the first measurements. The Bland and Altman method was used to study the inter/intraobserver variability. A Wilcoxon signed-rank test was also used to analyse differences between observers. Results: Interobserver variability for semi-manual measurements between the first and second observers was between 1.2 to 1.0 mm for maximal and minimal diameter, respectively. Intraobserver variability of each observer ranged from 0.8 to 1.2 mm, the lowest variability being produced by the more experienced observer. CAD variability could be as low as 0.3 mm, showing that it can perform better than human observers. However, when used in nonoptimal conditions (streak artefacts from contrast in the superior vena cava or weak lumen enhancement), CAD has a variability that can be as high as 0.9 mm, reaching variability of semi-manual measurements. Furthermore, there were significant differences between both observers for maximal and minimal diameter measurements (p<0.001). There was also a significant difference between the first observer and CAD for maximal diameter measurements with the former underestimating the diameter compared to the latter (p<0.001). As for minimal diameters, they were higher when measured by the second observer than when measured by CAD (p<0.001). Neither the difference of mean minimal diameter between the first observer and CAD nor the difference of mean maximal diameter between the second observer and CAD was significant (p=0.20 and 0.06, respectively). Conclusion: CAD algorithms can lessen the variability of diameter measurements in the follow-up of ascending aorta aneurysms. Nevertheless, in non-optimal conditions, it may be necessary to correct manually the measurements. Improvements of the algorithms will help to avoid such a situation.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Autosomal recessive cutis laxa type I (ARCL type I) is characterized by generalized cutis laxa with pulmonary emphysema and/or vascular complications. Rarely, mutations can be identified in FBLN4 or FBLN5. Recently, LTBP4 mutations have been implicated in a similar phenotype. Studying FBLN4, FBLN5, and LTBP4 in 12 families with ARCL type I, we found bi-allelic FBLN5 mutations in two probands, whereas nine probands harbored biallelic mutations in LTBP4. FBLN5 and LTBP4 mutations cause a very similar phenotype associated with severe pulmonary emphysema, in the absence of vascular tortuosity or aneurysms. Gastrointestinal and genitourinary tract involvement seems to be more severe in patients with LTBP4 mutations. Functional studies showed that most premature termination mutations in LTBP4 result in severely reduced mRNA and protein levels. This correlated with increased transforming growth factor-beta (TGFβ) activity. However, one mutation, c.4127dupC, escaped nonsense-mediated decay. The corresponding mutant protein (p.Arg1377Alafs(*) 27) showed reduced colocalization with fibronectin, leading to an abnormal morphology of microfibrils in fibroblast cultures, while retaining normal TGFβ activity. We conclude that LTBP4 mutations cause disease through both loss of function and gain of function mechanisms.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Question de recherche : Est-ce que la limite de taille de 7 mm d'un anévrisme intracrânien non rompu¦proposée par les études internationales est un critère valable de sélection entre un traitement¦conservateur (observation périodique) ou une intervention curative sur la population du CHUV ?¦Contexte : On estime actuellement la fréquence des anévrismes intracrâniens à 0.2-9% dans la¦population générale. Le taux d'hémorragie sous-arachnoïdienne due à une rupture d'anévrisme est¦estimé à 6-16 pour 100'000 personnes.¦Selon les investigateurs de l'International Study of Unruptured Intracranial Aneurysms (ISUIA, 2003),¦le taux cumulé de rupture à 5 ans pour les anévrismes de moins de 7 mm de diamètre est de 0.05% ou¦2.5% selon que l'anévrisme se situe sur une artère de la circulation cérébrale antérieure ou postérieure,¦respectivement.¦Ces chiffres sont fortement controversés. En effet, d'autres études montrent que le risque de rupture des¦anévrismes inférieurs à 7 mm de diamètre est bien plus important que ne le laisse supposer l'étude¦ISUIA.¦Objectifs : L'objectif de ce travail de maîtrise vise à déterminer si la limite de taille de 7 mm d'un¦anévrisme cérébral non rompu proposé par certaines études internationales (et notamment l'étude¦ISUIA) est un critère valable pour sélectionner entre une observation périodique ou une intervention¦curative (chirurgicale ou endovasculaire) des patients.¦Un corollaire qui découle de cette question est de savoir s'il est justifié de traiter d'emblée un¦anévrisme cérébral non rompu mesurant moins de 7 mm.¦Matériel et Méthodes : Etude rétrospective observationnelle basée sur des données provenant des¦dossiers médicaux des patients admis aux urgences du CHUV avec une hémorragie sousarachnoïdienne¦due à la rupture d'un anévrisme intracrânien pendant une période allant de juin 2005 à¦avril 2011.¦Différents paramètres sont pris en considération : l'âge et le sexe du patient, la taille, la localisation et le¦nombre d'anévrismes, les facteurs de risque de rupture comme le tabac, l'hypertension artérielle et la¦consommation d'alcool, ainsi que les antécédents et l'histoire familiale de rupture d'anévrisme.¦Le critère de jugement principal est la taille de l'anévrisme, suivi par sa localisation.¦Les critères d'exclusion des patients sont les suivants : anévrismes mycotique, fusiforme ou¦traumatique, tumeur cérébrale maligne.¦Résultats escomptés : Avec ce travail, une nouvelle limite de diamètre anévrismal pourrait être¦proposée, en tenant compte des différents paramètres analysés sur un échantillon de la population¦locale. Les résultats pourraient apporter plus de précisions dans le bilan du risque d'une rupture¦anévrismale. Ainsi, la décision d'une intervention bénéficierait d'une base de réflexion nouvelle pour¦les anévrismes non rompus de petite taille.¦Plus-value escomptée : Cette étude pourrait contribuer à améliorer le pronostic des patients porteurs¦d'anévrisme(s) intracrânien(s). Elle permettrait en effet d'intervenir en cas d'anévrismes intracrâniens¦non rompus de taille inférieure à 7 mm, avant que ceux-ci ne se rompent et provoquent une hémorragie¦sous-arachnoïdienne.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

BACKGROUND: Both systolic and diastolic dysfunction have been observed in patients with anterolateral myocardial infarction. Diastolic dysfunction is related to disturbances in relaxation and diastolic filling. OBJECTIVE: To analyse cardiac rotation, regional shortening and diastolic relaxation in patients with anterolateral infarction. METHODS: Cardiac rotation and relaxation in controls and patients with chronic anterolateral infarction were assessed by myocardial tagging. Myocardial tagging is based on magnetic resonance imaging and allows us to label specific myocardial regions for imaging cardiac motion (rotation, translation and radial displacement). A rectangular grid was placed on the myocardium (basal, equatorial and apical short-axis plane) of each of 18 patients with chronic anterolateral infarction and 13 controls. Cardiac rotation, change in area and shortening of circumference were determined in each case. RESULTS: The left ventricle in controls performs a systolic wringing motion with a clockwise rotation at the base and a counterclockwise rotation at the apex when viewed from the apex. During relaxation a rotational motion in the opposite direction (namely untwisting) can be observed. In patients with anterolateral infarction, there is less systolic rotation at the apex and diastolic untwisting is delayed and prolonged in comparison with controls. In the presence of a left ventricular aneurysm (n = 4) apical rotation is completely lost. There is less shortening of circumference in infarcted and remote regions. CONCLUSIONS: The wringing motion of the myocardium might be an important mechanism involved in maintaining normal cardiac function with minimal expenditure of energy. This mechanism no longer operates in patients with left ventricular aneurysms and operates significantly less than normal in those with anterolateral hypokinaesia. Diastolic untwisting is significantly delayed and prolonged in patients with anterolateral infarction, which could explain the occurrence of diastolic dysfunction in these patients.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Background: Visceral artery aneurysms (VAA), although uncommon, are increasingly being detected. We describe a case of spontaneous retroperitoneal hemorrhage from a ruptured IMA aneurysm associated with stenosis of the superior mesenteric artery (SMA) and celiac trunk, successfully treated with surgery. Methods: A 65-year-old man presented with abdominal pain and hypovolemic shock. Abdominal CT scan showed an aneurysm of the inferior mesenteric artery with retroperitoneal hematoma. In addition, an obstructive disease of the superior mesenteric artery and celiac axis was observed. Results: Upon emergency laparotomy a ruptured inferior mesenteric artery aneurysm was detected. The aneurysm was excised and the artery reconstructed by end-to-end anastomosis. Conclusions This report discusses the etiology, presentation, diagnosis and case management of inferior mesenteric artery aneurysms

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Immunoglobulin G4 (IgG4)-related fibroinflammatory systemic disease accounts for 7% of all noninfectious aneurysms of the thoracic aorta. A patient was admitted with a symptomatic ascending aortic aneurysm and thickened aortic wall (outer/inner diameter 55/45 mm), which was replaced. Probes revealed IgG4-related aortitis associated with a primary tuberculosis infection. Corticosteroid and antituberculosis therapies were used, and the patient's clinical evolution was favorable. The optimal treatment strategy of IgG4-related aortitis, a new entity, remains vague. Inner aortic diameter alone does not justify aortic replacement, but wall thickening may mimic intramural hematoma. In this particular case of IgG4-related aortitis, immunosuppressive treatment alone, as an alternative to a surgical procedure, may be debatable.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

L’objectiu d’aquest projecte es dissenyar i implementar un entorn de suport al diagnòstic dels aneurismes. Aquest entorn s’haurà d’integrar en la plataforma Starviewer. La plataforma Starviewer és un entorn de processament i visualització de dades mèdiques desenvolupat conjuntament entre el Laboratori de Gràfics i Imatge de la UdG i l’ Institut de Diagnòstic per la Imatge de l’Hospital Josep Trueta de Girona. Aquesta plataforma ofereix les funcionalitats bàsiques per diagnosticar a partir d’imatges. Tot i les funcionalitats de la plataforma, en la versió actual no es suporta el processament avançat d’imatge d’angiografia. En aquest projecte ens proposem ampliar aquesta plataforma integrant els mòduls necessaris que permetin el processament d’angiografies usades en el diagnòstic dels aneurismes

Relevância:

10.00% 10.00%

Publicador:

Resumo:

A 28-year-old woman consulted for disabling pulsatile tinnitus. Clinical examination suggested a venous etiology. An aneurysm of the transverse-sigmoid sinus was identified on computed tomography angiography (CTA) and confirmed by digital subtraction angiography. Endovascular occlusion of the aneurysm with detachable coils permanently eliminated the bruit. Thus, this report is of a new case of pulsatile tinnitus caused by an aneurysm of the transverse-sigmoid sinus, with a focus on a literature review and etiopathophysiology. Embryological studies suggest that these aneurysms represent a partial remnant of the petrosquamous sinus.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The intravital diagnosis of intracranial arterial dissection is not always possible due to atypic and non-specific clinical and radiological presentations. The postmortem pathological examination of cerebral blood vessels is therefore necessary to establish or confirm the presence of a dissecting aneurysm of intracranial arteries. Most of the described cases showed no significant underlying vascular pathology. Here we present the case of a 24-year-old women who died 5 days after admission to the hospital for a rapidly developing right-sided hemisyndrome. Neuroradiological examination had revealed ill-defined bifrontal hypodense lesions and angiographic findings were compatible with a dissection of the left extracranial internal carotid artery with embolic subocclusion of both anterior cerebral arteries. The pathological evaluation ruled out a thromboembolic occlusion of cerebral arteries and an extracranial internal carotid artery dissection but showed an extended dissecting process of variable age in the anterior circulation of the circle of Willis. The dissected vessels showed pathological changes characteristic of segmental mediolytic "arteritis" [Slavin and Gonzalez-Vitale 1976]. To our knowledge this is the first report on intracranial arteries being affected by this pathologic entity. Our case illustrates the importance of a postmortem examination of dissecting aneurysms of intracranial arteries. Careful serial section studies of dissected intracranial arteries in young subjects should be performed and may allow for a better understanding of the vascular pathology underlying the dissection processus.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

In this project, we have investigated new ways of modelling and analysis of human vasculature from Medical images. The research was divided in two main areas: cerebral vasculature analysis and coronary arteries modeling. Regarding cerebral vasculature analysis, we have studed cerebral aneurysms, internal carotid and the Circle of Willis (CoW). Aneurysms are abnormal vessel enlargements that can rupture causing important cerebral damages or death. The understanding of this pathology, together with its virtual treatment, and image diagnosis and prognosis, includes identification and detailed measurement of the aneurysms. In this context, we have proposed two automatic aneurysm isolation method, to separate the abnormal part of the vessel from the healthy part, to homogenize and speed-up the processing pipeline usually employed to study this pathology, [Cardenes2011TMI, arrabide2011MedPhys]. The results obtained from both methods have been also compared and validatied in [Cardenes2012MBEC]. A second important task here the analysis of the internal carotid [Bogunovic2011Media] and the automatic labelling of the CoW, Bogunovic2011MICCAI, Bogunovic2012TMI]. The second area of research covers the study of coronary arteries, specially coronary bifurcations because there is where the formation of atherosclerotic plaque is more common, and where the intervention is more challenging. Therefore, we proposed a novel modelling method from Computed Tomography Angiography (CTA) images, combined with Conventional Coronary Angiography (CCA), to obtain realistic vascular models of coronary bifurcations, presented in [Cardenes2011MICCAI], and fully validated including phantom experiments in [Cardene2013MedPhys]. The realistic models obtained from this method are being used to simulate stenting procedures, and to investigate the hemodynamic variables in coronary bifurcations in the works submitted in [Morlachi2012, Chiastra2012]. Additionally, another preliminary work has been done to reconstruct the coronary tree from rotational angiography, and published in [Cardenes2012ISBI].

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Endovascular coiling is a well-established therapy for treating intracranial aneurysms. Nonetheless, postoperative hemodynamic changes induced by this therapy remain not fully understood. The purpose of this work is to assess the influence of coil configuration and packing density on intra-aneurysmal hemodynamics

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Purpose: The objective of this study is to investigate the feasibility of detecting and quantifying 3D cerebrovascular wall motion from a single 3D rotational x-ray angiography (3DRA) acquisition within a clinically acceptable time and computing from the estimated motion field for the further biomechanical modeling of the cerebrovascular wall. Methods: The whole motion cycle of the cerebral vasculature is modeled using a 4D B-spline transformation, which is estimated from a 4D to 2D + t image registration framework. The registration is performed by optimizing a single similarity metric between the entire 2D + t measured projection sequence and the corresponding forward projections of the deformed volume at their exact time instants. The joint use of two acceleration strategies, together with their implementation on graphics processing units, is also proposed so as to reach computation times close to clinical requirements. For further characterizing vessel wall properties, an approximation of the wall thickness changes is obtained through a strain calculation. Results: Evaluation on in silico and in vitro pulsating phantom aneurysms demonstrated an accurate estimation of wall motion curves. In general, the error was below 10% of the maximum pulsation, even in the situation when substantial inhomogeneous intensity pattern was present. Experiments on in vivo data provided realistic aneurysm and vessel wall motion estimates, whereas in regions where motion was neither visible nor anatomically possible, no motion was detected. The use of the acceleration strategies enabled completing the estimation process for one entire cycle in 5-10 min without degrading the overall performance. The strain map extracted from our motion estimation provided a realistic deformation measure of the vessel wall. Conclusions: The authors' technique has demonstrated that it can provide accurate and robust 4D estimates of cerebrovascular wall motion within a clinically acceptable time, although it has to be applied to a larger patient population prior to possible wide application to routine endovascular procedures. In particular, for the first time, this feasibility study has shown that in vivo cerebrovascular motion can be obtained intraprocedurally from a 3DRA acquisition. Results have also shown the potential of performing strain analysis using this imaging modality, thus making possible for the future modeling of biomechanical properties of the vascular wall.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

This paper presents a technique to estimate and model patient-specific pulsatility of cerebral aneurysms over onecardiac cycle, using 3D rotational X-ray angiography (3DRA) acquisitions. Aneurysm pulsation is modeled as a time varying-spline tensor field representing the deformation applied to a reference volume image, thus producing the instantaneousmorphology at each time point in the cardiac cycle. The estimated deformation is obtained by matching multiple simulated projections of the deforming volume to their corresponding original projections. A weighting scheme is introduced to account for the relevance of each original projection for the selected time point. The wide coverage of the projections, together with the weighting scheme, ensures motion consistency in all directions. The technique has been tested on digital and physical phantoms that are realistic and clinically relevant in terms of geometry, pulsation and imaging conditions. Results from digital phantomexperiments demonstrate that the proposed technique is able to recover subvoxel pulsation with an error lower than 10% of the maximum pulsation in most cases. The experiments with the physical phantom allowed demonstrating the feasibility of pulsation estimation as well as identifying different pulsation regions under clinical conditions.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The increasing volume of data describing humandisease processes and the growing complexity of understanding, managing, and sharing such data presents a huge challenge for clinicians and medical researchers. This paper presents the@neurIST system, which provides an infrastructure for biomedical research while aiding clinical care, by bringing together heterogeneous data and complex processing and computing services. Although @neurIST targets the investigation and treatment of cerebral aneurysms, the system’s architecture is generic enough that it could be adapted to the treatment of other diseases.Innovations in @neurIST include confining the patient data pertaining to aneurysms inside a single environment that offers cliniciansthe tools to analyze and interpret patient data and make use of knowledge-based guidance in planning their treatment. Medicalresearchers gain access to a critical mass of aneurysm related data due to the system’s ability to federate distributed informationsources. A semantically mediated grid infrastructure ensures that both clinicians and researchers are able to seamlessly access andwork on data that is distributed across multiple sites in a secure way in addition to providing computing resources on demand forperforming computationally intensive simulations for treatment planning and research.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

BACKGROUND: Knowledge in the aetiopathogeny of aortic disease helps to characterise aortic lesions better and determine the risk of evolution and therapeutic strategies as well. This article focusses on aneurysms and dissections, and excludes causes related to infection, systemic inflammatory diseases and trauma. METHODS AND RESULTS: The biomedical literature of the past 10 years has been reviewed here. Aortic diseases are heterogeneous along the aorta as far as their genetic determinants, contribution of smooth muscle cells, inflammation and thrombus formation are concerned. Degradation of extracellular matrix by proteases causing aortic disease is a 'terminal' event, modulated by genetic background, haemodynamic strain, cellular events and thrombus formation. New genetic determinants of aortic disease have been identified. Proteases degrading the aortic wall are derived from a variety of cell types in addition to macrophages, including neutrophils on the luminal thrombus, mesenchymal and endothelial cells in the wall. Smooth muscle cells contribute to aortic wall homeostasis against inflammation and proteolysis. The degradation of the wall is followed by, or paralleled with, a failure of aortic reconstruction. CONCLUSIONS: Aortic diseases are diverse, and involve a multiplicity of biological systems in the vascular wall and at the interface with blood. Future research needs to unravel distinct cellular and molecular mechanisms causing the clinical events, in particular, dissection, expansion of already formed aneurysms and rupture.