995 resultados para Alkali absorption method
Resumo:
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)
Resumo:
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)
Resumo:
Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)
Resumo:
Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)
Resumo:
Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)
Resumo:
Electronic and optical properties of recently discovered single-shell carbon cluster nanotubes are studied through a semiempirical INDOCI method. The calculations are performed within the cluster model and include up to 196 atoms. The trend of the forbidden band gap with the number of carbon atoms (Cn n = 60, 10, 140) for a fixed diameter is analyzed. With increasing n the band gap decreases, as expected. The tubule, with diameter of 7.2Å (as C60-Buckyball) is predicted to be a metal or a narrow-gap semiconductor. The calculated absorption spectra of the clusters show a characteristic strong peak around 40,000 cm-1. Other features of the calculated UV-visible absorption spectra are discussed. © 1994.
Resumo:
A new process for the surface modification of hydrogen storage intermetallic particles used as anode material in secondary batteries is proposed in this article. The copper oxide particles coverage obtained by the sol-gel method is proposed to produce, under operational conditions of a Ni-MH battery, a metallic framework that tolerates the volume changes in charge/discharge cycles and does not inhibit the hydrogen absorption. Furthermore it was noticed an enhancement on the discharge capacity of the electrode material that can be related to a new hydrogen storage phase or to an inhibition of the surface oxidation promoted by the film coverage.
Resumo:
A calibration method was developed using flow injection analysis (FI) with a Gradient Calibration Method (GCM). The method allows the rapid determination of zinc In foods (approximately 30 min) after treatment with concentrated sulphuric acid and 30% hydrogen peroxide, and analysis with flame atomic absorption spectrometry (FAAS). The method provides analytical results with a relative standard deviation of about 2% and requires less time than by conventional FI calibration. The electronic selection of different segments along the gradient and monitoring of the technique covers wide concentration ranges while maintaining the inherent high precision of flow injection analysis. Concentrations, flow rates, and flow times of the reagents were optimized in order to obtain best accuracy and precision. Flow rates of 10 mL/min were selected for zinc. In addition, the system enables electronic dilution and calibration where a multipoint curve can be constructed using a single sample injection.
Resumo:
Polysaccharicles, as alginate and chitosan, have been used to obtain modified release dosage forms. Alginate, due to its property of building gels during the complex formation with calcium ions, allows the building of capsules containing a core constituted by calcium alginate. This work had for objective to determine the appropriate calcium concentration for the preparation of alginate-chitosan capsules, by means of calcium quantification using atomic absorption spectrophotometry. The methodology of calcium quantification was validated through analysis of the limit of detection, precision, accuracy and recovery of the method. The capsules, containing or not the drug, were prepared by the complex coacervation/ionotropic gelification method. Calcium was quantified after samples mineralization and dilution in lantanium solution. The results showed that the amount of calcium incorporated into the capsules depends on the amount of calcium added to the medium, and this ratio increases until the concentration of 1.5% of initial calcium chloride and above this concentration there is a decrease in the proportion of calcium bonded. It was observed that the proportion of calcium that links to the polymer is inversely proportional to the amount of calcium added. The calcium amount incorporated depends on the concentration of the polymeric dispersions used as well as on the ratio between the two polymers.
Resumo:
A simple, rapid, and sensitive spectrophotometric method for routine analysis of saccharin in commercial noncaloric sweeteners is proposed. This method is based on the reaction of saccharin with tetrachloro-p-benzoquinone (p-chloranil) accelerated by hydrogen peroxide and conducted in an ethanol:acetone (4:1) medium, producing a violet-red compound (γ max = 550 nm). Beer's law is obeyed in a concentration range of 2.05 × 10 -4 to 3.00 × 10 -3 M with an excellent correlation coefficient (r = 0.9998). The detection limit was 1.55 × 10 -5 M, and the effect of interferences on the spectrophotometric measurements was evaluated. The proposed procedure was applied successfully to the determination of saccharin in noncaloric sweeteners. Recoveries were within 99.2-104.3% with standard deviations ranging from to 0.5-1.6%. Results of the proposed method compare very favorably with those given by the high-performance liquid chromatography method recommended by the Food and Drug Administration.
Resumo:
A simple and reproducible method was developed for the assay of lomefloxacin in tablets. The excipients in the commercial tablet preparation did not interfere with the assay. Beer's law is obeyed in the range 2.0-9.0 μg.mL-1 at λmax 280 nm. The molar absorptivity was calculated. Six triplicate analyses of solutions containing six different concentrations of the examined drug were carried out and gave a mean correlation coefficient 0.9997. The proposed method was applied to the determination of the examined drug in coated tablet and the results demonstrated that the method is equally accurate, precise and reproducible as the official methods.