976 resultados para After-occupation evaluation


Relevância:

40.00% 40.00%

Publicador:

Resumo:

The aim of this study was to assess the electrical activity of the masseter and anterior temporal muscles in patients with severe bone resorption, with complete dentures worn for over ten years, and five months after having new dentures put in place. The RDC questionnaire was applied to twelve asymptomatic patients, before and five months after new dentures were put in place. The electrical activity recordings were made in the mandibular position at rest, and during maximum tooth clenching. The electrical activity of the masseter and anterior temporal muscles in the position at rest presented no statistically significant difference after five months of wearing the new complete dentures. Electrical activity during tooth clenching exhibited a statistically significant reduction only in the right temporal muscle. A period longer than five months of wearing the new complete dentures is required for adaptation and the acquisition of functional capacity.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Objectives: The objective of this study was to evaluate by a visual method of comparison the color stability of nonpigmented and pigmented facial silicones after accelerated aging. Materials and Methods: Two kinds of silicones were used in this study; one specifically formulated for facial prostheses and the other an acetic silicone for industrial use. Twenty-four trial bodies were made for each silicone. These were divided into colorless and intrinsically pigmented groups: ceramic, make-up, and iron oxide. The groups were submitted to accelerated aging for nonmetallic materials. An initial reading and subsequent readings were made at 163, 351, 692, and 1000 hours using a visual method of comparison. The values were annotated in a spreadsheet by two observers, according to scores elaborated for this study. Results: All groups presented color stability in the visual method. According to the results obtained and analyzed in this study, we can conclude that both silicones, Silastic 732 RTV and Silastic MDX 4-4210, behaved similarly, they can therefore be indicated for use in maxillofacial prosthesis. The time factor of aging influenced negatively, independently of the pigmentation, or lack of it, and of silicones and no group had visually noticeable alterations in any of the accelerated aging time, independently of the addition or not of pigments.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Creatine kinase (CK) and aspartate aminotransferase (AST) are mainly muscle-specific enzymes, which can be associated with muscle tissue damage. The aim of this study was to assess the activities of CK and AST during the postoperative period, after conventional (G1) and videolaparoscopic ovariectomy (G2), in queens. A further group (G3) was subjected to anaesthesia only. Results demonstrate that there were significant differences between groups. The highest levels of CK were recorded in Gl, however at a confidence level of p < 0.05 there was no significant difference between groups during the first 6 hours after surgery. A significant (p < 0.05) increase of CK values was identified between 0h and 3h in both groups (Gl and G2). Regarding AST activity there was no significant variation between groups, but again there was a significant difference between values at 0h and 3h after surgery. In conclusion, ovariectomy performed by videolap-aroscopy seems to cause less muscle damage when compared to the conventional method. © 2009 by Verlag Hans Huber, Hogrefe AG, Bem.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

INTRODUCTION: Soft liners have been developed to offer comfort to denture wearers. However, this comfort is compromised when there is a change in the properties of the material, causing colour change, solubility, absorption and hardening. These characteristics can compromise the longevity of soft liners. AIM: The aim of this in vitro study was to investigate the effect of ageing on both the hardness and colour change of two soft liners following accelerated ageing. METHODS: Two denture liners, one resin based (Trusoft, Bosworth, Illinois, USA) and one silicone based (Ufi Gel P, Voco GMBH, Cuxhaven, Germany), were tested in this study for both hardness (using the Shore A scale) and colour change (using the CIE L*a*b* colour scale), initially and after 1008 hours (6 weeks) of accelerated ageing. Statistical analysis was performed using the unpaired t-test with the Welch correction. RESULTS: These indicated that both materials increased in hardness and underwent colour change after accelerated ageing. The initial hardness of Trusoft was far lower than that of Ufi Gel P (18.2 Shore A units vs 34.8 Shore A units). However, for Trusoft the changes for both hardness (from 18.2 to 52.1 Shore A units) and colour change (16.85 on the CIE L*a*b* colour scale) were greater than those for Ufi Gel P, for which hardness changed from 34.8 to 36.5 Shore A units and the colour change was 5.19 on the CIE L*a*b* colour scale. CONCLUSIONS: Ufi Gel P underwent less hardness and colour change after accelerated ageing than Trusoft. On the other hand, the use of Trusoft may be preferable in cases where initial softness is a major consideration, such as when relining an immediate denture after implant surgery.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

The aim of this study was to evaluate the Shore A hardness and color stability of two soft lining materials after thermocycling and when chemical polishing was used or omitted. Two acrylic-based soft lining materials were tested: Coe-Soft and Soft Confort, 14 specimens were made for each material. They were distributed in four groups according to the treatment performed. The specimens were thermocycled (1000 cycles) and half of the group submitted to chemical polishing (methyl methacrylate). Shore A hardness was determined and color stability was calculated by means of Commission International de l'Eclairage Lab uniform color scale using a spectrophotometer, the measurements were made immediately after deflasked, chemical polishing and thermocycling. Analysis of variance (ANOVA) and Tukey's tests were performed at p < 0.01. Color changes (deltaE) were observed after thermocycling in both soft lining materials: Soft Confort (10.60) showed significantly higher values than Coe-Soft (4.57). Coe-Soft (26.42) showed higher Shore A hardness values than Soft Confort (19.42). Chemical polishing did not influence in the color stability of both materials; however, influenced in the hardness values of Coe-Soft.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

This is the first study performed with an interocclusal splint with a vibrating device on patients with sleep bruxism. The purpose of the present study was to evaluate the effectiveness of the splint with vibrating device on patients who suffer from sleep bruxism through computerized electromyography (EMG) of the anterior temporal muscles. Eight male and female patients, ranging in age from 18 to 28 years, with evident signs and symptoms of bruxism were selected. The splint were made for the upper arch. The patients was treated with the interocclusal splint with a vibrating device, and submitted to EMG evaluations of the anterior temporal muscles on both sides. The evaluations were performed at the beginning of treatment and after 21 days of splint use. Electromyography was performed in an isometric contractions measuring of the temporal muscles. The following results obtained revealed that: when closing the mandible (isometric contraction), the anterior temporal muscles had an expressive reduction in electromyographic activity (p. < 0.10), so this splints were considered effective for patients who suffer from sleep bruxism. © 2009 Springer-Verlag.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

The aim of this paper was to compare the dentin-pulp complex response to cavity preparation in human teeth using ultrasonic chemical vapor deposition (CVD) diamond tip and high-speed diamond bur. Class V buccal cavities were randomly prepared in 40 premolars from 14 patients aged 11 to 15 years. The cutting time was recorded and the cavities had the axial walls protected with gutta-percha and were filled with glass ionomer cement. The teeth were extracted at intervals of 0, 5, 10 and 20 days, and were decalcified, sectioned and stained by Hematoxylin & Eosin, Masson's Trichrome and Brown & Brenn techniques. The inflammatory response and cell disorganization were blindly evaluated by two examiners. The remaining dentin thickness (RDT) was measured by a linear scale using computer software. Statistical analysis by one-way ANOVA showed no statistically significant difference (P≤0.05) among the cavities prepared with either type of instrument, with mean RDT of 1132.50 mm. Cutting time and the pulp-dentin complex responses were analyzed statistically by Kruskal-Wallis and Dunn tests (P≤0.05). The ultrasonic CVD diamond tip took 5 times longer to prepare the cavities and there were no typical inflammatory pulp responses in cavities prepared with either type of cutting instrument, only mild to moderate cell disorganization was present. Even taking longer to cut the dental substrate, the ultrasonic CVD diamond tip produced similar pulp response compared to the conventional high-speed diamond bur.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Introduction: An appropriate selection of instruments is essential to perform a correct debonding technique, by properly removing orthodontic brackets and the remaining resin. Objective: The aim of this study was to evaluate three methods of remaining resin removal on enamel surface after bracket debonding, by means of Scanning Electron Microscopy (SEM). Methods: Eighteen bovine incisors were selected and divided into three groups (A, B and C) of six teeth each. Before bracket bonding, epoxy resin casts were obtained by impression of the teeth with addition silicon, in order to register baseline enamel characteristics and representing the control group. The methods for remaining resin removal were: Group A - gross and medium granulation Soflex discs; Group B - carbide bur in low-speed; Group C - carbide bur in high-speed. Soflex polishing system fine and ultrafine granulation discs were used for Group A, rubber tips for Groups B and C, and polishing paste for all groups. After polishing, impression of teeth were taken and casts were analyzed by means of SEM. The baseline enamel characteristics (Control Group) were compared to the final aspect of enamel to determine the method that generated less enamel abrasion. Results and Conclusion: The remaining resin removal by carbide bur in low-rotation, and enamel polished with rubber tips followed by polishing paste produced the smaller damage to the enamel.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Purpose: The use of different light sources as an adjunct to in-office bleaching has been questioned. Thus, the aim of this study was to evaluate the color changes of teeth after application of bleaching techniques with different products, with and without activation by a LED-laser system. Methods: Twenty-four bovine teeth surfaces were submitted to three bleaching techniques with two commercially available 35% hydrogen peroxide bleaching agents (n=8). The specimens were immersed in red wine for 48 h at 37°C and submitted to the bleaching techniques. Color changes were measured before and after staining as well as immediately after and 24 h after the bleaching treatments, with two different methods of color evaluation, software ScanWhite V1.1 and intra-oral spectrophotometer (Vita Easyshade). Data were analyzed by ANOVA and Kruskal-Wallis test. Results: The statistical analysis showed that there was no statistically significant difference at 5% of significance level between the different groups, independently of the evaluation time, evaluation methods or the use of LED-laser systems. Conclusion: The results suggested that the use of light in the bleaching techniques did not influence the color changes. Copyright: © 2011 Roberto et al.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Several dermocosmetic bases even without active substances, can increase the cutaneous hydration, resulting in a beneficial effect to the skin. The evidence and interpretation of possible hydration effect of formulations in the skin can be carried through by means of histopathological and histomorphometrical evaluation, a time that allows the analysis of the epithelial tissue, of dermis and also of the cellular characteristics. The objective of this research was to evaluate the skin hydration after exposition to the aqueous and hydroalcoholic bases and silicone emulsion. Swines had areas submitted to treatments during 15 days with three different formulations (F1 - aqueous gel, F2 - hydroalcoholic gel and F3 - silicone emulsion). By means of histometric and histopathological techniques were gotten the thickness of the epidermis and stratum corneum. Comparison of means was done using ANOVA followed by the Tukey test. The F1 provoked significant increase in the thickness of the epidermis. The formulaton F2 provoked significant reduction in the thickness of the epidermis and stratum corneum. F3 not presented significant difference in this structures. According to the study, the type of base chosen intervenes with the skin hydration.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Chemical compatibility between geomembranes and site-specific waste liquids should be assessed since the waste liquids are highly complex mixtures. This paper presents some considerations about the chemical compatibility of geomembranes and some results of mechanical tests in HDPE and PVC geomembranes that were exposed to leachate and chemical residue (niobium). PVC and HDPE geomembranes of two thicknesses were tested: 1.0, 2.0 mm (PVC) and 0.8, 2.5 mm (HDPE). The results obtained show that after exposure the PVC geomembranes (1.0, 2.0 mm) were more rigid and stiffer than fresh samples. The HDPE geomembranes, on the other hand, when exposed to leachate and niobium residue presented increases in deformation. Melt flow index (MFI) tests were also carried out to verify the oxidation. © 2013 ejge.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Countries have different official programs and implement different sampling methods for the detection of Salmonella on poultry carcasses. In Brazil, a 25-g sample of skin and muscle excision (SME) from the wings, neck, and pericloacal parts is used; in the European Union (EU), a 25-g sample of neck skin (NSE) is used; and, in the United States, the whole carcass is rinsed with 400 ml of diluent (WCR). In the present study, these methods were evaluated to compare Salmonella occurrence and counts of hygiene indicator microorganisms (Escherichia coli, Enterobacteriaceae, and total viable count of aerobic mesophilic bacteria) using different carcasses from the same flock and also using different analytical units taken from the same carcass. Eighty flocks, with four broiler carcasses from each, were included in this study; three broilers were sampled according to protocols from Brazil, the EU, and the United States, and the last one by all three methods. SME, NSE, and WCR provided equivalent results (P > 0.05) for Salmonella detection on broiler carcasses when using different carcasses from the same flock and when using the same carcass. The predominant serovar was Salmonella Enteritidis. For the enumeration of hygiene indicator microorganisms, WRC provided higher counts than SME or NSE (P < 0.05), when using both the same or different carcasses. Therefore, it is possible to directly compare Salmonella results in poultry carcasses when using the methods recommended by the legislative bodies of Brazil, the United States, and the EU. However, WCR provides the best results for hygiene indicator microorganisms. Copyright © International Association for Food Protection.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

OBJETIVO: avaliar, in vitro, a influência do clareamento dentário com gel contendo fosfato de cálcio amorfo (ACP) na resistência da união adesiva de braquetes metálicos. MÉTODOS: trinta e seis dentes incisivos bovinos foram seccionados no limite coronorradicular e tiveram suas coroas incluídas em cilindros de PVC. Os corpos de prova foram divididos em três grupos (n = 12), de acordo com a realização do tratamento clareador e tipo de gel utilizado, sendo: G1 (controle) - sem clareamento; G2 - clareamento com gel sem ACP (Whiteness Perfect, FGM); G3 - clareamento com gel contendo ACP (Nite White ACP, Discus Dental). Os grupos G2 e G3 foram submetidos a 14 ciclos de clareamento, seguidos de intervalo de espera de 15 dias para a fixação adesiva dos braquetes metálicos. O ensaio mecânico de cisalhamento foi realizado em máquina universal Kratos, com velocidade de 0,5mm/min. Após o teste mecânico, os corpos de prova foram avaliados quanto ao índice de remanescente adesivo (ARI). Os resultados foram submetidos à ANOVA, ao teste de Tukey e ao de Kruskall-Wallis (α = 5%). RESULTADOS: diferenças significativas foram observadas entre os grupos testados. O grupo controle G1 (11,1MPa) mostrou uma resistência ao cisalhamento estatisticamente superior aos grupos submetidos ao clareamento (G2 = 5,40MPa; G3 = 3,73MPa), os quais não diferiram entre si. Não se observou diferença significativa para o ARI entre os grupos estudados. CONCLUSÃO: o clareamento dentário reduz a resistência da união adesiva de braquetes metálicos, enquanto a presença de ACP no gel clareador não influencia os resultados encontrados.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Introduction Visceral leishmaniasis (VL) is caused by the intracellular protozoan Leishmania donovani complex. VL may be asymptomatic or progressive and is characterized by fever, anemia, weight loss and the enlargement of the spleen and liver. The nutritional status of the patients with VL is a major determinant of the progression, severity and mortality of the disease, as it affects the clinical progression of the disease. Changes in lipoproteins and plasma proteins may have major impacts in the host during infection. Thus, our goal was evaluate the serum total cholesterol, high-density lipoprotein (HDL), low-density lipoprotein (LDL), triglycerides, glucose, albumin, globulin and total protein levels, as well as the body composition, of VL patients before and after treatment. Methods Nutritional evaluation was performed using the bioelectrical impedance analysis (BIA) to assess body composition. Biochemical data on the serum total cholesterol, HDL, LDL, triglycerides, glucose, albumin, globulin and total protein were collected from the medical charts of the patients. Results BIA indicated that both pre-treatment and post-treatment patients exhibited decreased phase angles compared to the controls, which is indicative of disease. Prior to treatment, the patients exhibited lower levels of total body water compared to the controls. Regarding the biochemical evaluation, patients with active VL exhibited lower levels of total cholesterol, HDL, LDL and albumin and higher triglyceride levels compared to patients after treatment and the controls. Treatment increased the levels of albumin and lipoproteins and decreased the triglyceride levels. Conclusions Our results suggest that patients with active VL present biochemical and nutritional changes that are reversed by treatment.