951 resultados para Abdominal Wall
Resumo:
INTRODUCTION Since the initial publication in 2000, Angiotensin II-infused mice have become one of the most popular models to study abdominal aortic aneurysm in a pre-clinical setting. We recently used phase contrast X-ray based computed tomography to demonstrate that these animals develop an apparent luminal dilatation and an intramural hematoma, both related to mural ruptures in the tunica media in the vicinity of suprarenal side branches. AIMS The aim of this narrative review was to provide an extensive overview of small animal applicable techniques that have provided relevant insight into the pathogenesis and morphology of dissecting AAA in mice, and to relate findings from these techniques to each other and to our recent PCXTM-based results. Combining insights from recent and consolidated publications we aimed to enhance our understanding of dissecting AAA morphology and anatomy. RESULTS AND CONCLUSION We analyzed in vivo and ex vivo images of aortas obtained from macroscopic anatomy, histology, high-frequency ultrasound, contrast-enhanced micro-CT, micro-MRI and PCXTM. We demonstrate how in almost all publications the aorta has been subdivided into a part in which an intact lumen lies adjacent to a remodeled wall/hematoma, and a part in which elastic lamellae are ruptured and the lumen appears to be dilated. We show how the novel paradigm fits within the existing one, and how 3D images can explain and connect previously published 2D structures. We conclude that PCXTM-based findings are in line with previous results, and all evidence points towards the fact that dissecting AAAs in Angiotensin II-infused mice are actually caused by ruptures of the tunica media in the immediate vicinity of small side branches.
Resumo:
To propose an automated patient-specific algorithm for the creation of accurate and smooth meshes of the aortic anatomy, to be used for evaluating rupture risk factors of abdominal aortic aneurysms (AAA). Finite element (FE) analyses and simulations require meshes to be smooth and anatomically accurate, capturing both the artery wall and the intraluminal thrombus (ILT). The two main difficulties are the modeling of the arterial bifurcations, and of the ILT, which has an arbitrary shape that is conforming to the aortic wall.
Resumo:
A semi-automatic segmentation algorithm for abdominal aortic aneurysms (AAA), and based on Active Shape Models (ASM) and texture models, is presented in this work. The texture information is provided by a set of four 3D magnetic resonance (MR) images, composed of axial slices of the abdomen, where lumen, wall and intraluminal thrombus (ILT) are visible. Due to the reduced number of images in the MRI training set, an ASM and a custom texture model based on border intensity statistics are constructed. For the same reason the shape is characterized from 35-computed tomography angiography (CTA) images set so the shape variations are better represented. For the evaluation, leave-one-out experiments have been held over the four MRI set.
Resumo:
A novel method for generating patient-specific high quality conforming hexahedral meshes is presented. The meshes are directly obtained from the segmentation of patient magnetic resonance (MR) images of abdominal aortic aneu-rysms (AAA). The MRI permits distinguishing between struc-tures of interest in soft tissue. Being so, the contours of the lumen, the aortic wall and the intraluminal thrombus (ILT) are available and thus the meshes represent the actual anato-my of the patient?s aneurysm, including the layered morpholo-gies of these structures. Most AAAs are located in the lower part of the aorta and the upper section of the iliac arteries, where the inherent tortuosity of the anatomy and the presence of the ILT makes the generation of high-quality elements at the bifurcation is a challenging task. In this work we propose a novel approach for building quadrilateral meshes for each surface of the sectioned geometry, and generating conforming hexahedral meshes by combining the quadrilateral meshes. Conforming hexahedral meshes are created for the wall and the ILT. The resulting elements are evaluated on four patients? datasets using the Scaled Jacobian metric. Hexahedral meshes of 25,000 elements with 94.8% of elements well-suited for FE analysis are generated.
Resumo:
In order to perform finite element (FE) analyses of patient-specific abdominal aortic aneurysms, geometries derived from medical images must be meshed with suitable elements. We propose a semi-automatic method for generating conforming hexahedral meshes directly from contours segmented from medical images. Magnetic resonance images are generated using a protocol developed to give the abdominal aorta high contrast against the surrounding soft tissue. These data allow us to distinguish between the different structures of interest. We build novel quadrilateral meshes for each surface of the sectioned geometry and generate conforming hexahedral meshes by combining the quadrilateral meshes. The three-layered morphology of both the arterial wall and thrombus is incorporated using parameters determined from experiments. We demonstrate the quality of our patient-specific meshes using the element Scaled Jacobian. The method efficiently generates high-quality elements suitable for FE analysis, even in the bifurcation region of the aorta into the iliac arteries. For example, hexahedral meshes of up to 125,000 elements are generated in less than 130 s, with 94.8 % of elements well suited for FE analysis. We provide novel input for simulations by independently meshing both the arterial wall and intraluminal thrombus of the aneurysm, and their respective layered morphologies.
Resumo:
Abdominal Aortic Aneurism is a disease related to a weakening in the aortic wall that can cause a break in the aorta and the death. The detection of an unusual dilatation of a section of the aorta is an indicative of this disease. However, it is difficult to diagnose because it is necessary image diagnosis using computed tomography or magnetic resonance. An automatic diagnosis system would allow to analyze abdominal magnetic resonance images and to warn doctors if any anomaly is detected. We focus our research in magnetic resonance images because of the absence of ionizing radiation. Although there are proposals to identify this disease in magnetic resonance images, they need an intervention from clinicians to be precise and some of them are computationally hard. In this paper we develop a novel approach to analyze magnetic resonance abdominal images and detect the lumen and the aortic wall. The method combines different algorithms in two stages to improve the detection and the segmentation so it can be applied to similar problems with other type of images or structures. In a first stage, we use a spatial fuzzy C-means algorithm with morphological image analysis to detect and segment the lumen; and subsequently, in a second stage, we apply a graph cut algorithm to segment the aortic wall. The obtained results in the analyzed images are pretty successful obtaining an average of 79% of overlapping between the automatic segmentation provided by our method and the aortic wall identified by a medical specialist. The main impact of the proposed method is that it works in a completely automatic way with a low computational cost, which is of great significance for any expert and intelligent system.
Resumo:
Universidade Estadual de Campinas . Faculdade de Educação Física
Resumo:
JUSTIFICATIVA E OBJETIVOS: Hipotermia intra-operatória é complicação frequente, favorecida por operação abdominal. A eficácia da associação dos métodos de aquecimento por condução e convecção na prevenção de hipotermia e seus efeitos no período de recuperação pós-operatória foram os objetivos deste estudo. MÉTODO: Quarenta e três pacientes de ambos os sexos de 18 a 88 anos de idade, submetidos à laparotomia xifopúbica sob anestesia geral e monitorização da temperatura esofágica, foram distribuídos de modo aleatório em dois grupos de aquecimento: COND (n = 24), com colchão de circulação de água a 37°C no dorso e COND + CONV (n = 19), com a mesma condição associada à manta de ar aquecido a 42°C sobre o tórax e membros superiores. Analisados peso, sexo, idade, duração da operação e anestesia, temperaturas na indução anestésica (Mi), horas consecutiva (M1, M2), final da operação (Mfo) e anestesia (Mfa), entrada (Me-REC) e saída (Ms-REC) da recuperação pós-anestésica (SRPA), além das incidências de tremores e queixas de frio no pós-operatório. RESULTADOS: Os grupos foram semelhantes em todas as variáveis analisadas, exceto nas temperaturas em M2, M3, M4, Mfo e Mfa. O grupo COND reduziu a temperatura a partir da segunda hora da indução anestésica, mas o grupo COND + CONV só na quarta hora. Em COND, observou-se hipotermia na entrada e saída da SRPA. CONCLUSÕES: Associar métodos de aquecimento retardou a instalação e diminui a intensidade da hipotermia intra-operatória, mas não reduziu a incidência das queixas de frio e tremores.
Resumo:
INTRODUCTION: The antibacterial effect of ozone (O3) has been described in the extant literature, but the role of O3 therapy in the treatment of certain types of infection remains controversial. OBJECTIVES: To evaluate the effect of intraperitoneal (i.p.) O3 application in a cecal ligation/puncture rat model on interleukins (IL-6, IL-10) and cytokine-induced neutrophil chemoattractant (CINC)-1 serum levels, acute lung injury and survival rates. METHODS: Four animal groups were used for the study: a) the SHAM group underwent laparotomy; b) the cecal ligation/puncture group underwent cecal ligation/puncture procedures; and c) the CLP+O2 and CLP+O3 groups underwent CLP+ corresponding gas mixture infusions (i.p.) throughout the observation period. IL-6, CINC-1 and IL-10 concentrations were determined by enzyme-linked immunosorbent assay (ELISA). Acute lung injury was evaluated with the Evans blue dye lung leakage method and by lung histology. P<0.05 was considered significant. RESULTS: CINC-1 was at the lowest level in the SHAM group and was lower for the CLP+O3 group vs. the CLP+O2 group and the cecal ligation/puncture group. IL-10 was lower for the SHAM group vs. the other three groups, which were similar compared to each other. IL-6 was lower for the SHAM group vs. all other groups, was lower for the CLP+O3 or CLP+O2 group vs. the cecal ligation/puncture group, and was similar for the CLP+O3 group vs. the CLP+O2 group. The lung histology score was lower for the SHAM group vs. the other groups. The Evans blue dye result was lower for the CLP+O3 group vs. the CLP+O2 group and the cecal ligation/puncture group but similar to that of the SHAM group. The survival rate for the CLP+O3 group was lower than for the SHAM group and similar to that for the other 2 groups (CLP and CLP+O2). CONCLUSION: Ozone therapy modulated the inflammatory response and acute lung injury in the cecal ligation/puncture infection model in rats, although there was no improvement on survival rates.
Resumo:
A distrofia muscular de Duchenne (DMD) é um tipo de distrofia muscular em humanos caracterizada por uma doença genética ligada ao cromossomo X. O cão golden retriever portador da distrofia muscular (GRMD) tem sido intensamente estudado e considerado o modelo mais representativo para a doença observada em humanos. Assim, como forma de verificar anormalidades em órgãos internos nesses animais, foi realizado o exame ultra-sonográfico de 24 cães golden retriever saudáveis, portadores e afetados pela distrofia muscular. O exame ultra-sonográfico do GRMD diagnosticou aumento hepático de moderado a severo, incluindo os vasos hepáticos e seus ramos e aumento de ecogenicidade da vesícula biliar e vesícula urinária. Entretanto, não foram observadas imagens claras de alterações no baço e nos vasos ramos da aorta. A partir disso, acreditamos que o exame ultra-sonográfico constitui-se em um procedimento útil no acesso de órgãos abdominais em cães afetados pela distrofia muscular.
Resumo:
As características morfológicas, macroscópicas e microscópicas, dos órgãos genitais masculinos e da cloaca foram analisados em 23 emas, quatro filhotes (duas semanas), sete jovens (de três a oito meses) e doze adultos (três anos), provenientes da Cooperativa Emas do Brasil, RS, e do CEMAS, Mossoró, RN. Os testículos da ema possuem formato alongado e localizam-se na cavidade celomática, na região intra-abdominal dorsal, com comprimento e larguras médias de 7,6±1,2cm e 2,6± 0,7cm nos adultos; 4,5±1,5cm e 0,9±0,4cm nos jovens; e 0,8±0,3cm, e 0,2±0,1cm nos filhotes. O testículo está envolto pela túnica albugínea e seu parênquima possui túbulos seminíferos irregulares, compostos por epitélio espermatogênico e por células de sustentação, e pelo tecido intersticial, com as células endócrinas intersticiais, tecido conjuntivo frouxo e vasos. Nos adultos observaram-se todas as células da linhagem espermatogênica, enquanto nos jovens com 3 meses, os testículos apresentaram túbulos seminíferos com luz reduzidas, espermatogônias e células de sustentação indiferenciadas. Os ductos eferentes possuem um epitélio cúbico ciliado, enquanto no ducto epididimário o epitélio é columnar. O epidídimo apresentou-se alongado e fusiforme junto a margem medial do testículo. O ducto deferentes apresentou trajeto sinuoso nos adultos, retilíneo nos jovens, convoluto na sua porção média, diminuindo seu formato sigmóide em sua porção caudal, próximo à cloaca. O epitélio é pseudoestratificado e reveste a luz irregular nos adultos e circular nos jovens, mantendo proximidade com o ureter. A cloaca dividiu-se em três segmentos: o coprodeu, o urodeo e o proctodeo. No urodeu os ductos deferentes desembocaram em papilas na parede ventro-lateral, próximo a inserção do falo fibroso. O falo é um órgão fibroso linfático, localizado na parede ventral, no assoalho da cloaca, e apresentou duas porções: uma rígida bifurcada e contorcida, e outra simples espiralada e flexível, a qual normalmente esteve invertida. Em exposição forçada, o falo teve 14 cm de comprimento. De forma geral os órgãos reprodutores das emas compartilharam da morfologia de outras aves, principalmente aquelas descritas para os avestruzes.
Resumo:
OBJETIVOS: avaliar a prevalência de obesidade global e obesidade abdominal, em mulheres pós-menopausa, segundo o grau de instrução, nível de atividade física, uso de terapia hormonal na menopausa (THM) e paridade. MÉTODOS: foram entrevistadas 157 mulheres na pós-menopausa, atendidas em dois ambulatórios públicos da cidade de São Paulo, São Paulo, Brasil. A obesidade foi determinada segundo o índice de massa corporal (IMC > 30,0) e segundo o percentual de gordura corporal (%GC > 37%). A obesidade abdominal foi determinada pela relação cintura-quadril (RCQ > 0,85). RESULTADOS: a prevalência de obesidade global foi 34,4% (segundo o IMC) e de 40,1% (segundo o %GC). A prevalência de obesidade abdominal foi de 73,8%. Grande parte das entrevistadas referiu até sete anos de instrução formal (47,8%), foi considerada sedentária ou insuficientemente ativa (52,3%) e nunca tinha utilizado THM oral ou tinha utilizado por menos de 12 meses (72,0%). Foi constatada maior prevalência de obesidade global no grupo de mulheres sedentárias ou insuficientemente ativas e no grupo de não usuárias de THM (p<0,05). Quanto à obesidade abdominal, fator de risco para doenças cardiovasculares (DCV), apenas o grau de instrução mostrou-se associado à RCQ (p<0,05). CONCLUSÕES: mulheres após a menopausa, fisicamente ativas e usuárias de THM exibiram menor prevalência de obesidade global, porém a prevalência de obesidade abdominal foi alta e ainda maior nas mulheres com menor grau de instrução
Resumo:
In this paper we argue that the effects of irregular chaotic motion of particles transported by blood can play a major role in the development of serious circulatory diseases. Vessel wall irregularities modify the flow field, changing in a nontrivial way the transport and activation of biochemically active particles. We argue that blood particle transport is often chaotic in realistic physiological conditions. We also argue that this chaotic behavior of the flow has crucial consequences for the dynamics of important processes in the blood, such as the activation of platelets which are involved in the thrombus formation.
Resumo:
This research work focuses on the analysis of hydraulic transients in polyvinyl chloride (PVC) pipes, which are characterized by a viscoelastic rheological behavior. Transient pressure data were collected in a pipe rig consisting of a set of PVC pipes. The creep function of the PVC pipes was determined by using an inverse transient model based on collected transient pressure data and compared with that obtained by carrying out mechanical tensile tests of PVC pipe specimens. The numerical results obtained from the transient solver have shown that the attenuation, dispersion, and shape of transient pressures were well described. The incorporation of the viscoelastic mechanical behavior in the hydraulic transient model has provided an excellent fitting between numerical results and observed data. Calibrated creep function based on inverse analysis fit the one determined by mechanical tests well, which emphasized the importance of pipe-wall viscoelasticity in hydraulic transients in PVC pipes.
Resumo:
The magnetic Barkhausen noise (MBN) is a phenomenon sensitive to several kinds of magnetic material microstructure changes, as well as to variations in material plastic deformation and stress. This fact stimulates the development of MBN-based non-destructive testing (NDT) techniques for analyzing magnetic materials, being the proposition of such a method, the main objective of the present study. The behavior of the MBN signal envelope, under simultaneous variations of carbon content and plastic deformation, is explained by the domain wall dynamics. Additionally, a non-destructive parameter for the characterization of each of these factors is proposed and validated through the experimental results. (C) 2010 Elsevier B.V. All rights reserved.