984 resultados para APPROPRIATE TECHNOLOGY
Resumo:
Opioid dependence is a chronic, relapsing condition that is associated with significant morbidity and mortality. Methadone maintenance therapy involves the provision of a controlled supply of an orally administered opioid, thereby stabilising the opioid-dependent patient. Research studies have shown that methadone maintenance reduces illicit opioid use, opioid-related crime, premature mortality and the risk of HIV infection. It is most effective when prescribed at an adequate dosage (usually 60 to 100 mg/day) and when long term maintenance on methadone is the goal of treatment rather than detoxification from all drugs including methadone. Successful long term methadone maintenance is more likely when it takes place within the context of a well established therapeutic relationship and when the medical, social and psychological needs of patients are met either through direct assistance or referral.
Resumo:
Two humanized monoclonal antibody constructs bearing the same variable regions of an anti-CD3 monoclonal antibody, whole IgG and FvFc, were expressed in CHO cells. Random and site-specific integration were used resulting in similar expression levels. The transfectants were selected with appropriate selection agent, and the surviving cells were plated in semi-solid medium for capture with FITC-conjugated anti-human IG antibody and picked with the robotic ClonePix FL. Conditioned media from selected clones were purified by affinity chromatography and characterized by SDS-PAGE, Western-blot, SEC-HPLC, and isoelectric focusing. Binding to the target present in healthy human mononuclear cells was assessed by flow cytometry, as well as by competition between the two constructs and the original murine monoclonal antibody. The humanized constructs were not able to dislodge the murine antibody while the murine anti-CD3 antibody could dislodge around 20% of the FvFc or IgG humanized versions. Further in vitro and in vivo pre-clinical analyses will be carried out to verify the ability of the humanized versions to demonstrate the immunoregulatory profile required for a humanized anti-CD3 monoclonal antibody.
Resumo:
The absence of considerations of technology in policy studies reinforces the popular notion that technology is a neutral tool, Through an analysis of the role played by computers in the policy processes of Australia's Department of Social Security, this paper argues that computers are political players in policy processes, Findings indicate that computers make aspects of the social domain knowable and therefore governable, The use of computers makes previously infeasible policies possible, Computers also operate as bureaucrats and as agents of client surveillance. Increased policy change, reduced discretion and increasingly targeted and complex policies can be attributed to the use of computer technology, If policy processes are to be adequately understood and analysed, then the role of technology in those processes must be considered.
Resumo:
Radiation dose calculations in nuclear medicine depend on quantification of activity via planar and/or tomographic imaging methods. However, both methods have inherent limitations, and the accuracy of activity estimates varies with object size, background levels, and other variables. The goal of this study was to evaluate the limitations of quantitative imaging with planar and single photon emission computed tomography (SPECT) approaches, with a focus on activity quantification for use in calculating absorbed dose estimates for normal organs and tumors. To do this we studied a series of phantoms of varying complexity of geometry, with three radionuclides whose decay schemes varied from simple to complex. Four aqueous concentrations of (99m)Tc, (131)I, and (111)In (74, 185, 370, and 740 kBq mL(-1)) were placed in spheres of four different sizes in a water-filled phantom, with three different levels of activity in the surrounding water. Planar and SPECT images of the phantoms were obtained on a modern SPECT/computed tomography (CT) system. These radionuclides and concentration/background studies were repeated using a cardiac phantom and a modified torso phantom with liver and ""tumor"" regions containing the radionuclide concentrations and with the same varying background levels. Planar quantification was performed using the geometric mean approach, with attenuation correction (AC), and with and without scatter corrections (SC and NSC). SPECT images were reconstructed using attenuation maps (AM) for AC; scatter windows were used to perform SC during image reconstruction. For spherical sources with corrected data, good accuracy was observed (generally within +/- 10% of known values) for the largest sphere (11.5 mL) and for both planar and SPECT methods with (99m)Tc and (131)I, but were poorest and deviated from known values for smaller objects, most notably for (111)In. SPECT quantification was affected by the partial volume effect in smaller objects and generally showed larger errors than the planar results in these cases for all radionuclides. For the cardiac phantom, results were the most accurate of all of the experiments for all radionuclides. Background subtraction was an important factor influencing these results. The contribution of scattered photons was important in quantification with (131)I; if scatter was not accounted for, activity tended to be overestimated using planar quantification methods. For the torso phantom experiments, results show a clear underestimation of activity when compared to previous experiment with spherical sources for all radionuclides. Despite some variations that were observed as the level of background increased, the SPECT results were more consistent across different activity concentrations. Planar or SPECT quantification on state-of-the-art gamma cameras with appropriate quantitative processing can provide accuracies of better than 10% for large objects and modest target-to-background concentrations; however when smaller objects are used, in the presence of higher background, and for nuclides with more complex decay schemes, SPECT quantification methods generally produce better results. Health Phys. 99(5):688-701; 2010
Resumo:
This study examined the impact of computer and assistive device use on the employment status and vocational modes of people with physical disabilities in Australia. A survey was distributed to people over 15 years in age with physical disabilities living in the Brisbane area. Responses were received from 82 people, including those with spinal cord injuries, cerebral palsy and muscular dystrophy. Of respondents 46 were employed, 22 were unemployed, and 12 were either students or undertaking voluntary work. Three-quarters of respondents used a computer in their occupations, while 15 used assistive devices. Using logistic regression analysis it was found that gender, education, level of computer skill and computer training were significant predictors of employment outcomes. Neither the age of respondent nor use of assistive software were significant predictors. From information obtained in this study guidelines for a training programme designed to maximize the employability of people with physical disabilities were developed.
Resumo:
Background: Although various techniques have been used for breast conservation surgery reconstruction, there are few studies describing a logical approach to reconstruction of these defects. The objectives of this study were to establish a classification system for partial breast defects and to develop a reconstructive algorithm. Methods: The authors reviewed a 7-year experience with 209 immediate breast conservation surgery reconstructions. Mean follow-up was 31 months. Type I defects include tissue resection in smaller breasts (bra size A/B), including type IA, which involves minimal defects that do not cause distortion; type III, which involves moderate defects that cause moderate distortion; and type IC, which involves large defects that cause significant deformities. Type II includes tissue resection in medium-sized breasts with or without ptosis (bra size C), and type III includes tissue resection in large breasts with ptosis (bra size D). Results: Eighteen percent of patients presented type I, where a lateral thoracodorsal flap and a latissimus dorsi flap were performed in 68 percent. Forty-five percent presented type II defects, where bilateral mastopexy was performed in 52 percent. Thirty-seven percent of patients presented type III distortion, where bilateral reduction mammaplasty was performed in 67 percent. Thirty-five percent of patients presented complications, and most were minor. Conclusions: An algorithm based on breast size in relation to tumor location and extension of resection can be followed to determine the best approach to reconstruction. The authors` results have demonstrated that the complications were similar to those in other clinical series. Success depends on patient selection, coordinated planning with the oncologic surgeon, and careful intraoperative management.
Resumo:
Background The development of products and services for health care systems is one of the most important phenomena to have occurred in the field of health care over the last 50 years. It generates significant commercial, medical and social results. Although much has been done to understand how health technologies are adopted and regulated in developed countries, little attention has been paid to the situation in low- and middle-income countries (LMICs). Here we examine the institutional environment in which decisions are made regarding the adoption of expensive medical devices into the Brazilian health care system. Methods We used a case study strategy to address our research question. The empirical work relied on in-depth interviews (N = 16) with representatives of a wide range of actors and stakeholders that participate in the process of diffusion of CT (computerized tomography) scanners in Brazil, including manufacturers, health care organizations, medical specialty societies, health insurance companies, regulatory agencies and the Ministry of Health. Results The adoption of CT scanners is not determined by health policy makers or third-party payers of public and private sectors. Instead, decisions are primarily made by administrators of individual hospitals and clinics, strongly influenced by both physicians and sales representatives of the medical industry who act as change agents. Because this process is not properly regulated by public authorities, health care organizations are free to decide whether, when and how they will adopt a particular technology. Conclusions Our study identifies problems in how health care systems in LMICs adopt new, expensive medical technologies, and suggests that a set of innovative approaches and policy instruments are needed in order to balance the institutional and professional desire to practise a modern and expensive medicine in a context of health inequalities and basic health needs.