897 resultados para 660402 Residential and commercial
Resumo:
Urban agriculture, a dynamic multifunctional phenomenon, affects the spatial diversification of urban land use, its valorization and its governance. Literature acknowledges its contribution to the development of sustainable cities. The dimension and extent of this contribution depends significantly on the particular form and function of urban agriculture. However, the complexity of interests and dimensions is insufficiently covered by theory. This paper proposes a typology for urban agriculture, supporting both theory building and practical decision processes. We reviewed and mapped the diversity of the types of agriculture found along three beneficial dimensions (self-supply, socio-cultural, commercial) for product distribution scale and actors. We distinguish between ideal types, subtypes and mixed types. Our intention is to include a dynamic perspective in the typology of urban agricultural land use because transition processes between types are observable due to the existence of complex motivations and influences. In a pilot study of 52 urban agriculture initiatives in Germany, we tested the validity of the typology and discussed it with stakeholders, proving novelty and relevance for profiling discussions.
Resumo:
Concrete made of brick chips as coarse aggregate are extensively used in Bangladesh for construction of different types of structures from residential and commercial buildings to industrial complex. As creep is influenced among many factors including the constituents’ materials, relative humidity and temperature, it is essential to examine the creep behavior for Bangladeshi brick chips made concrete in Bangladeshi environment. In this work, investigation on the behaviour of creep in concrete of same grade made with brick chips collected from various locations under single stage loading was done. With these investigations, a formula was derived to get theoretical creep values for 24 MPa brick chips made concrete in Bangladeshi environment.
Resumo:
Fire safety of light gauge steel frame (LSF) stud walls is important in the design of buildings. Currently LSF walls are increasingly used in the building industry, and are usually made of cold-formed and thin-walled steel studs that are fire-protected by two layers of plasterboard on both sides. Many experimental and numerical studies have been undertaken to investigate the fire performance of load bearing LSF walls under standard fire conditions. However, the standard time-temperature curve does not represent the fire load present in typical residential and commercial buildings that include considerable amount of thermoplastic materials. Real building fires are unlikely to follow a standard time-temperature curve. However, only limited research has been undertaken to investigate the fire performance of load bearing LSF walls under realistic design fire conditions. Therefore in this research, finite element thermal models of the traditional LSF wall panels without cavity insulation and the new LSF composite wall panels were developed to simulate their fire performance under recently developed realistic design fire curves. Suitable thermal properties were proposed for plasterboards and insulations based on laboratory tests and literature review. The developed models were then validated by comparing their thermal performance results with available results from realistic design fire tests, and were later used in parametric studies. This paper presents the details of the developed finite element thermal models of load bearing LSF wall panels under realistic design fire time-temperature curves and the re-sults. It shows that finite element thermal models can be used to predict the fire performance of load bearing LSF walls with varying configurations of insulations and plasterboards under realistic design fires. Failure times of load bearing LSF walls were also predicted based on the results from finite element thermal analyses.
Resumo:
Load bearing Light Gauge Steel Frame (LSF) walls made of cold-formed steel studs and tracks are commonly used in residential and commercial buildings. Fire safety of these walls is essential to minimize the damage caused by fire related accidents. Past investigations on the fire performance of load bearing LSF wall systems have been limited to LSF walls made of conventional lipped channel section studs. Although structurally efficient hollow flange steel sections are available in the building industry, they are not used as LSF wall studs due to the lack of fire performance data for such walls. The hollow flange sections have torsionally rigid hollow flanges that eliminate the occurrence of local and distortional buckling to an extent, thereby increasing their structural efficiency. The weaknesses of hollow flange sections such as lower lateral distortional buckling capacity are also eliminated when they are used as studs of LSF walls as the plasterboard restraints will prevent any lateral movement. Therefore hollow flange sections can be considered as structurally more efficient studs for use in LSF wall systems. This paper reports the full scale fire tests of LSF walls made of hollow flange section studs under standard fire conditions. The frames were made of 1.6 mm thick and 150 mm deep hollow flange section studs with two closed rectangular flanges of 45 mm width x 15 mm depth. Dual plasterboards were attached on both sides of the test wall panels. The load ratio was varied and the failure times, the lateral deflections and the axial displacements of the test walls were obtained. The failure behaviour of LSF walls made of hollow flange section studs was found to be different to that of LSF walls made of conventional lipped channel section studs. The results of these fire tests show that hollow flange section studs have a higher potential in being used in load bearing LSF Walls.
Resumo:
Cold-formed steel members have been widely used in residential and commercial buildings as primary load bearing structural elements. They are often made of thin steel sheets and hence they are more susceptible to local buckling. The buckling behaviour of cold-formed steel compression members under fire conditions is not fully investigated yet and hence there is a lack of knowledge on the fire performance of cold-formed steel compression members. Current cold-formed steel design standards do not provide adequate design guidelines for the fire design of cold-formed steel compression members. Therefore a research project based on extensive experimental and numerical studies was undertaken to investigate the local buckling behaviour of light gauge cold-formed steel compression members under simulated fire conditions. First a series of 91 local buckling tests was conducted at ambient and uniform elevated temperatures up to 700oC on cold-formed lipped and unlipped channels. Suitable finite element models were then developed to simulate the behaviour of tested columns and were validated using test results. All the ultimate load capacity results for local buckling were compared with the predictions from the available design rules based on AS/NZS 4600, BS 5950 Part 5, Eurocode 3 Parts 1.2 and 1.3 and the direct strength method (DSM), based on which suitable recommendations have been made for the fire design of cold-formed steel compression members subject to local buckling at uniform elevated temperatures.
Resumo:
Our built heritage plays an important role in the ongoing story of our city. Modern cities such as Brisbane embraced Art Deco style in its architecture as it swept the world during the interwar period. From inner city landmarks such as the striking McWhirters department store to lesser-known gems further afield like the streamlined Archerfield Airport administration building, Brisbane has a significant range of intriguing and beautiful Art Deco buildings. This publication documents and celebrates a selection of our favourite residential and commercial examples. Written contributions from a range of authors are complemented by stunning modern photography and historic archive imagery, taking readers on a journey through this fascinating era. The articles not only describe the aesthetic and architectural features, but also delve into the associated social history. Brisbane Art Deco: Stories of our Built Heritage is a charming and informative reference, and offers a colourful insight into Brisbane’s built heritage and the life and times of this dynamic city.
Resumo:
Light gauge steel frame (LSF) wall systems are increasingly used in residential and commercial buildings as load bearing and non-load bearing elements. Conventionally, the fire resistance ratings of such building elements are determined using approximate prescriptive methods based on limited standard fire tests. However, recent studies have shown that in some instances real building fire time-temperature curves could be more severe than the standard fire curve, in terms of maximum temperature and rate of temperature rise. This has caused problems for safe evacuation and rescue activities, and in some instances has also lead to the collapse of buildings earlier than the prescribed fire resistance. Therefore a detailed research study into the performance of LSF wall systems under both standard fire and realistic fire conditions was undertaken using full scale fire tests to understand the fire performance of different LSF wall configurations. Both load bearing and non-load bearing full scale fire tests were performed on LSF walls configurations which included single layer, double layer, externally insulated wall panels made up of different steel sections and thicknesses of gypsum plasterboards. The non-load bearing fire test results were utilized to understand the factors affecting the fire resistance of LSF walls, while loading bearing fire test results led to development of simplified methods to predict the fire resistance ratings of load bearing LSF walls exposed to both standard and realistic design fires. This paper presents the results of full scale experimental study and highlights the effects of standard and realistic fire conditions on fire performance of LSF walls.
Resumo:
Earthquakes cause massive road damage which in turn causes adverse effects on the society. Previous studies have quantified the damage caused to residential and commercial buildings; however, not many studies have been conducted to quantify road damage caused by earthquakes. In this study, an attempt has been made to propose a new scale to classify and quantify the road damage due to earthquakes based on the data collected from major earthquakes in the past. The proposed classification for road damage due to earthquake is called as road damage scale (RDS). Earthquake details such as magnitude, distance of road damage from the epicenter, focal depth, and photographs of damaged roads have been collected from various sources with reported modified Mercalli intensity (MMI). The widely used MMI scale is found to be inadequate to clearly define the road damage. The proposed RDS is applied to various reported road damage and reclassified as per RDS. The correlation between RDS and earthquake parameters of magnitude, epicenter distance, hypocenter distance, and combination of magnitude with epicenter and hypocenter distance has been studied using available data. It is observed that the proposed RDS correlates well with the available earthquake data when compared with the MMI scale. Among several correlations, correlation between RDS and combination of magnitude and epicenter distance is appropriate. Summary of these correlations, their limitations, and the applicability of the proposed scale to forecast road damages and to carry out vulnerability analysis in urban areas is presented in the paper.
Resumo:
Floods occurred on streams in the vicinity of Perry, Taylor County, Florida, on June 9, 1957, as a result of heavy rains from atropical disturbance. Serious flooding occurred in Perry along Spring and Pimple creeks as outlined by the shaded area in figure 1, requiring the evacuation of about ZOO families from the lowland area. No loss of life was reported. The damages to residential and commercial properties were estimated at several million dollars. Most of the damage was confined to residential areas (fig. 2); however, several stores in the area were damaged by flood waters (fig. 3). This report presents data pertaining to the rainfall accompanying this storm and peak flows of Spring and Pimple creeks in Perry. It contains flood elevations at several points, and peak discharges of the two creeks flowing through Perry. The report also contains a discussion of the rainfall associated with the flood and a description of the general features of the flood. (PDF contains 16 pages.)
Resumo:
Com base em um cenário econômico favorável combinado aos avanços tecnológicos das ciências dos materiais e processos de construção, nas últimas três décadas, as cidades brasileiras têm apresentado um crescimento substancial, no que diz respeito à construção de edifícios residenciais e comerciais de múltiplos andares. Atualmente, estes edifícios apresentam níveis de esbeltez elevados e têm sido construídos com estruturas cada vez mais ousadas e que englobam a experiência e o conhecimento dos engenheiros de estruturas. Como o principal objetivo dos projetistas está associado à concepção de estruturas mais leves, o projeto estrutural requer um conhecimento teórico substancial a fim de tornar compatíveis os requisitos arquitetônicos com as condições necessárias para a estabilidade. Assim sendo, o objetivo desta dissertação de mestrado é o de investigar o comportamento estrutural estático e dinâmico (linear e não linear) de um edifício misto (aço-concreto) de 20 pavimentos. Para tal, o estudo apresenta os resultados de análises estáticas e dinâmicas lineares e não lineares para ações de serviço. O comportamento estrutural do edifício, quando submetido às ações dinâmicas induzidas pelo vento, também foi investigado. Os resultados revelam que edifícios esbeltos merecem atenção especial, no que diz respeito à concepção do projeto estrutural, sendo que seu comportamento deve ser verificado através de metodologias completas que incluam análises do tipo estática e dinâmica (lineares e não lineares).
Resumo:
Considerando-se um cenário econômico bastante favorável em conjunto com avanços tecnológicos da ciência dos materiais e processos construtivos, nos últimos trinta anos, as cidades brasileiras têm apresentado um crescimento substancial, no que diz respeito à construção de edifícios residenciais e comerciais de múltiplos andares. Nos dias de hoje, estes edifícios apresentam níveis de esbeltez elevados e têm sido construídos com estruturas cada vez mais arrojadas englobando a experiência e o conhecimento dos engenheiros civis. Deste modo, o principal objetivo dos projetistas está associado à concepção de estruturas mais leves, nas quais o projeto estrutural requer um conhecimento teórico substancial, objetivando tornar compatíveis os requisitos arquitetônicos com as condições necessárias para a estabilidade. Assim sendo, o objetivo deste trabalho de pesquisa é o de investigar o comportamento estrutural estático e dinâmico de um edifício misto (aço-concreto) de 20 pavimentos quando submetido às ações dinâmicas do vento não determinísticas. Deste modo, no desenvolvimento do modelo computacional são empregadas técnicas usuais de discretização, via método dos elementos finitos, por meio do programa ANSYS. Para tal, o estudo apresenta os resultados de uma análise não linear geométrica para ações de serviço. A resposta dinâmica não determinística do modelo estrutural investigado, em termos dos valores máximos médios dos deslocamentos e das acelerações, foi obtida e comparada com os valores limites propostos por normas e recomendações de projeto.
Resumo:
193 Main Street (18AP44) is located between Main Street and Duke of Gloucester Street. The property was used ass a yard related to residential and commercial buildings during the 18th and 19th centuries. In the 1930's a movie theatre and parking lot were built on the property. That structure was torn down in the 1980's and a three-story commercial building was constructed. Archaeological excavations were conducted on the property from 1985-1987. A preliminary report was written in 1986 by Paul A. Shackel. This report is the final report on the archaeological investigations at 193 Main Street.
Resumo:
O presente relatório incluído na Unidade Curricular de Dissertação/Projeto/Estágio do Mestrado (DIPRE) em Engenharia Civil do Instituto Superior de Engenharia do Porto (ISEP) e desenvolvido no âmbito do estágio curricular realizado na empresa Asl & Associados, tem como principais objetivos a minha integração no mercado de trabalho e obtenção de experiência profissional. Neste trabalho, serão abordados temas como as introduções teóricas ao Comportamento Térmico e Acústico de Edifícios de Habitação, estudos de casos práticos como o Projeto de Comportamento Térmico de uma grande intervenção, Certificação Energética de edifícios existentes com base no Regulamento de Desempenho Energético dos Edifícios de Habitação e Ensaios Acústicos de Edifícios de acordo com o Regulamento dos Requisitos Acústicos dos Edifícios. O projeto realizado consistiu no estudo do comportamento térmico do edifício na Avenida Marechal Gomes da Costa nº802, no Porto. Nesse estudo realizou-se a verificação das soluções construtivas, por vezes foram propostas alterações das mesmas de modo a verificar os requisitos impostos pelo REH e foi realizada a emissão do seu pré-certificado. A maior parte do período em que decorreu o estágio na empresa foi preenchida com a realização de certificados energéticos de frações autónomas e de moradias. Para a recolha da informação necessária à sua elaboração, foram efetuadas várias vistorias aos imóveis referidos. Foram também efetuados durante o estágio, ensaios acústicos a edifícios de habitação e comércio e elaborado o respetivo relatório de ensaio.
Resumo:
Pendant les années 1950 et 1960, Montréal se modernise sur plusieurs aspects. L’influence de l’administration de la ville sur cette modernisation est bien connue. Toutefois, les perspectives des acteurs extérieurs sont souvent ignorées. Ce mémoire examine donc les opinions de la Chambre de commerce de Montréal sur la modernisation de la métropole québécoise lors de ces deux décennies. La source principale utilisée pour effectuer cette étude a été la revue hebdomadaire de la Chambre, Commerce-Montréal. Dans le premier chapitre, les opinions de la Chambre de commerce sur la gouvernance municipale sont examinées. Celles-ci montrent que la Chambre percevait l’assainissement des moeurs politiques et l’amélioration de l’efficacité administrative comme intrinsèques à la modernisation de Montréal. Le deuxième chapitre porte sur la circulation automobile et le transport en commun. La Chambre proposait des moyens d’accélérer le débit de la circulation qu’elle jugeait crucial pour la modernisation de la métropole. Le troisième chapitre traite du développement urbain. D’après la Chambre, la modernisation de Montréal exigeait le renouvellement du cadre bâti de la ville, tant résidentiel que commercial. L’étude de ces trois thèmes confirme que, pendant la période 1950-1970, la Chambre de commerce a contribué de manière significative aux débats concernant la modernisation de Montréal. Nous relevons aussi que l’organisme, malgré son désir de paraître apolitique, a été influencé par sa fonction de représentant de la communauté d’affaires francophone. L’importance accordée à la rentabilité de la modernisation, ainsi que la hiérarchisation sociale attribuée à certains sujets, confirment notamment les orientations conservatrices de l’organisme.
Resumo:
A model of a solar oven with a reflective surface composed of two mirror segments is presented, constituting a two semi-parabolic surfaces made of fiberglass, applied on a ceramic mold, intended to be used in residential and commercial cooking. The reflective surface of the semi-parable is obtained with the use of multiple plain segments of 2 mm wide mirrors. The semi-parabolic structure has visible movements that are comparable to that of the sun. The technical details of the manufacturing and assembling processes will be presented with an analysis of the viability of thermal, economic, and materials of such prototype. This prototype has important social implications and primordial aspects, which combats the ecological damages caused by the wide-scale use of firewood during cooking. It has been demonstrated that the solar oven has the capacity to cook simultaneous two meals distinct for a family of four