999 resultados para 1995_01271440 TM-58 4302609
Resumo:
FUNDAMENTO: A efetividade e segurança de stents farmacológicos (SF) ainda têm sido questionadas. OBJETIVO: O objetivo deste estudo foi avaliar a efetividade e segurança desses stents, e a incidência da revascularização da lesão tratada (RLT), além de identificar possíveis variáveis que influenciam a necessidade de RLT. MÉTODOS: Selecionaram-se 203 pacientes do Hospital Costantini que tiveram acompanhamento clínico no período de 1 a 3 anos. RESULTADOS: Observou-se o seguinte quadro: 470 lesões; 171 (84,24%) pacientes eram homens; 54 (26,6%), diabéticos; 131 (64,35%), hipertensos; 127 (62,56%), dislipidêmicos; 40 (19,70%), tabagistas; e 79 (38,92%) apresentavam história familiar de coronariopatia. Ainda: 49 (24,14%) pacientes apresentavam angina estável; 58 (28,57%), angina instável; e 6 (2,96%), infarto agudo do miocárdio. Desses pacientes, 85 (41,87%) eram assintomáticos, e 146 (71,92%), multiarteriais. Nas características das lesões, 77,45% foram B2/C (AHA/ACC). Taxus foi implantado em 73,62% dos pacientes. Em 381 (81,96%), constataram-se stents com diâmetro > 2,5 mm. O comprimento de stent era < 30 mm em 67,87% das lesões, com média de 2,3 stents por paciente. Após acompanhamento, 19 pacientes (9,3%) submeteram-se à RLT. Houve morte de 4 pacientes (1,97%), sendo 2 pacientes por IAM (0,98%), um com AVC (0,49%) e um com aneurisma de aorta abdominal (0,49%). Ainda observamos um paciente com trombose tardia (0,49%) e um com reinfarto (0,49%). Na análise estatística realizada, apenas a característica da lesão em bifurcação aproximou-se de significância estatística com p < 0,06. CONCLUSÃO: Concluímos que os stents farmacológicos apresentam boa efetividade e segurança, observamos incidência de 9,3% de RLT e não identificamos variável que indicasse a necessidade de RLT.
Resumo:
FUNDAMENTO: Na hipertensão arterial pulmonar (HAP) a qualidade de vida relacionada saúde (QVRS) tem sido investigada em curtos períodos de tempo (semanas), mas pouco se sabe sobre a perspectiva do paciente no médio e longo prazo. OBJETIVO: Analisar o estado de pacientes em terapias específicas de HAP durante um ano de observação, em termos de QVRS, e investigar se possíveis associações entre a capacidade de exercício (CE) e a QVRS persistem no médio prazo. MÉTODOS: Trinta e quatro pacientes em terapias para a HAP (bosentan e/ou sildenafil) foram selecionados (idade de 14 a 58 anos, mediana de 35,5 anos, classe funcional II ou III), e avaliados no momento basal, e 3, 6, 9 e 12 meses depois, usando o teste de caminhada de 6 minutos e questionário SF-36 de QVRS. RESULTADOS: A distância percorrida nos seis minutos não mudou durante o acompanhamento (387 - 432 metros, valores da mediana, p=0.2775), o mesmo para a classe funcional e saturação periférica de oxigênio. Os escores SF-36 também se mantiveram estáveis, com a saúde física sempre pior que a saúde mental. Das 40 possíveis associações entre a CE e QVRS, apenas 12 foram significativas (30%, p<0,05). A previsão de uma QVRS severamente deprimida com base em uma distância percorrida de 235 metros foi específica em >90%, mas sensível em <43%. CONCLUSÃO: Os pacientes com HAP que se mantêm estáveis em termos da CE também parecem fazê-lo em termos de QVRS. Contudo, CE e QVRS não têm ligação consistente com o tempo, e devem ser analisadas como diferentes perspectivas no paciente individual.
Resumo:
FUNDAMENTO: A estimulação crônica do ventrículo direito (EVD) induz um padrão de contração dessincronizado, produzindo assincronia interventricular e intraventricular. Muitos estudos têm mostrado a relação entre EVD e a forma e função ventricular esquerda (VE) comprometida. OBJETIVO: O objetivo deste estudo foi avaliar a sincronia e a função do VE em pacientes pediátricos que receberam EVD em comparação com aqueles que receberam estimulação do VE (EVE). MÉTODOS: As funções sistólica e diastólica e a sincronia do VE foram avaliadas em 80 pacientes pediátricos com bloqueio atrioventricular total não cirúrgico ou pós-cirúrgico, com estimulação a partir do endocárdio do ventrículo direito (VD) (n = 40) ou do epicárdio do VE (n = 40). Foram analisados dados ecocardiográficos obtidos antes da implantação do marca-passo, imediatamente após a implantação, e no final de um acompanhamento médio de 6,8 anos. RESULTADOS: A função diastólica do VE não se alterou em nenhum dos pacientes durante o acompanhamento. A função sistólica ventricular esquerda foi preservada nos pacientes que receberam EVE. No entanto, a fração de encurtamento e a fração de ejeção diminuíram de medianas de 41% ± 2,6% e 70% ± 6,9% antes da implantação para 32% ± 4,2% e 64% ± 2,5% (p < 0,0001 e p < 0,0001), respectivamente, no acompanhamento final. O atraso mecânico interventricular foi significativamente maior com a EVD (66 ± 13 ms) do que com a EVE (20 ± 8 ms). Da mesma forma, nos dois grupos houve uma diferença significativa entre os seguintes parâmetros: atraso mecânico do VE (EVD: 69 ± 6 ms, EVE: 30 ± 11 ms, p < 0,0001); atraso septo-lateral (RVP: 75 ± 19 ms, LVP: 42 ± 10 ms, p < 0,0001) e atraso septo-posterior (EVD: 127 ± 33 ms, EVE: 58 ± 17 ms, p < 0,0001). CONCLUSÃO: Quando comparado ao endocárdio do VD, o epicárdio do VE é um local ideal para a estimulação para preservar a sincronia e a função cardíaca.
Resumo:
É feita a análise de áreas com diferentes classes de declividade (A = 0-3%, B = 3-8%, C = 8-16% e D = 16-30%) sscom a fina1idade de se verificar a potencialidade de imagens TM/LANDSAT, na escala 1:100.000, para planejamento agrícola. Devido à ausência de visão tridimensional, o trabalho baseia-se nas relações quantitativas entre índices dedrenagem (freqüência de rios e densidade de drenagem) determinados a partir das imagens, e expressão do relevo (declividade média) extraída de cartas planialtimétricas, na escala 1:50.000. Fotografias aéreas na escala 1:35.000 são utilizadas para fins comparativos. Conclui-se que o uso dessas imagens para mapear classes de declividade através do padrão de drenagem é viável, embora as características regionais o tenham limitado para diferenciar mais facilmente áreas com declividades A e B de áreas com declividades C e D.
Resumo:
Infection with some genotypes of human papillomavirus (HPV) is the most important risk factor associated with cervical cancer (CC). Throughout the world, HPV type 58 prevalence varies from one region to another; it is higher in women from certain countries in Asia and Latin America, such as China and Mexico. Although intratypic variants have been reported on a few occasions, our knowledge about HPV 58 genetic variation remains limited. Therefore, this work aims to (i) determine the prevalence of HPV type 58 amongst Mexican women with invasive CC or precursor lesions and (ii) identify HPV 58 sequence variants. One hundred and forty five colposcopy clinic patients were studied. Genotyping of HPV 16, 18 and 58 was determined by specific nested PCR and HPV 58 variants were detected by direct sequencing. The general prevalence of HPV was 51.7% (75/145). HPV 16 was found in 30.6% (23/75) and HPV 58 in 24% (18/75) of the patients. HPV 18 was not identified in patients with cervical intraepithelial neoplasia (CIN) grade I; it was only found in those with CIN II, with a prevalence of 6.8% (3/44). In patients with CC, the prevalence of HPV 16 and 58 was 78.9%. Regarding HPV 58 variants, 94.4% of the HPV 58 sequences were identical to the prototype strain, whereas one sample showed changes at a single nucleotide. This study demonstrates a high prevalence of HPV 58 and a low genetic variability of E6 sequences amongst Mexican colposcopy patients.
Resumo:
BACKGROUND Challenges exist in the clinical diagnosis of drug-induced liver injury (DILI) and in obtaining information on hepatotoxicity in humans. OBJECTIVE (i) To develop a unified list that combines drugs incriminated in well vetted or adjudicated DILI cases from many recognized sources and drugs that have been subjected to serious regulatory actions due to hepatotoxicity; and (ii) to supplement the drug list with data on reporting frequencies of liver events in the WHO individual case safety report database (VigiBase). DATA SOURCES AND EXTRACTION (i) Drugs identified as causes of DILI at three major DILI registries; (ii) drugs identified as causes of drug-induced acute liver failure (ALF) in six different data sources, including major ALF registries and previously published ALF studies; and (iii) drugs identified as being subjected to serious governmental regulatory actions due to their hepatotoxicity in Europe or the US were collected. The reporting frequency of adverse events was determined using VigiBase, computed as Empirical Bayes Geometric Mean (EBGM) with 90% confidence interval for two customized terms, 'overall liver injury' and 'ALF'. EBGM of >or=2 was considered a disproportional increase in reporting frequency. The identified drugs were then characterized in terms of regional divergence, published case reports, serious regulatory actions, and reporting frequency of 'overall liver injury' and 'ALF' calculated from VigiBase. DATA SYNTHESIS After excluding herbs, supplements and alternative medicines, a total of 385 individual drugs were identified; 319 drugs were identified in the three DILI registries, 107 from the six ALF registries (or studies) and 47 drugs that were subjected to suspension or withdrawal in the US or Europe due to their hepatotoxicity. The identified drugs varied significantly between Spain, the US and Sweden. Of the 319 drugs identified in the DILI registries of adjudicated cases, 93.4% were found in published case reports, 1.9% were suspended or withdrawn due to hepatotoxicity and 25.7% were also identified in the ALF registries/studies. In VigiBase, 30.4% of the 319 drugs were associated with disproportionally higher reporting frequency of 'overall liver injury' and 83.1% were associated with at least one reported case of ALF. CONCLUSIONS This newly developed list of drugs associated with hepatotoxicity and the multifaceted analysis on hepatotoxicity will aid in causality assessment and clinical diagnosis of DILI and will provide a basis for further characterization of hepatotoxicity.
Resumo:
Carbapenemase production is an important mechanism of carbapenem resistance among nonfermentative Gram-negative isolates. This study aimed to report the detection of blaOXA-58 gene in multiresistant clinical isolates of Acinetobacter baumannii recovered from inpatients in a public hospital. Polymerase chain reaction tests were performed to detect the blaOXA-23-like, blaOXA-24-like, blaOXA-58-like and blaOXA-51-like genes. The blaOXA-58 and blaOXA-23 genes were detected in one and three isolates, respectively. Sequencing of the blaOXA-58-like amplicon revealed 100% identity with the A. baumannii blaOXA-58 gene listed in the GenBank database. This is the first report of an OXA-58-producing A. baumannii isolate in Rio de Janeiro, Brazil.
Resumo:
A Escala de Coma de Glasgow (ECGl) e a Escala de Coma de Jouvet (ECJ), são duas escalas usadas na avaliação da consciência em nosso meio. A análise e o uso dessas duas escalas têm indicado que elas se complementam, sendo a ECGl mais sensível à mudanças nos rebaixamentos mais intensos da consciência e a ECJ nos estados mais próximos do normal. O presente estudo teve como objetivo comparar os resultados obtidos na avaliação do nível de consciência no uso dessas duas escalas. A comparação foi realizada num estudo prospectivo com 48 pacientes maiores de 18 anos internados em três unidades gerais de terapia intensiva de diferentes hospitais privados do Município de São Paulo. As avaliações foram realizadas pelos pesquisadores diariamente, sendo as duas escalas aplicadas seqüencialmente uma à outra no tempo de aproximadamente 5 minutos. Cada uma das escalas foi aplicada em 106 avaliações realizadas e os resultados mostraram uma diferença estatisticamente significativa entre a ECGl e a ECJ na indicação de alteração de nível de consciência. Em 37,74% das avaliações realizadas com a ECJ houve indicação de alteração do nível de consciência, enquanto que na ECGl a alteração era apontada em apenas 23,58% das avaliações. Outra observação importante no uso de ambas escalas, foi que em indivíduos com escores na ECGl entre 9 e 11, a indicação de alteração de nível de consciência foi mais acentuada pela ECGl e naquelas com escores na ECGl entre 12 e 15 a ECJ indicou mais acentuada alteração de nível de consciência. No uso da ECGl houve aplicação do não testável (NT) em 20% das avaliações realizadas, não ocorrendo inviabilidade de aplicação de indicadores na ECJ. Entretanto, acredita-se que condições específicas do grupo estudado favoreceram esse resultado, assim como, características específicas de grupos de pacientes podem favorecer o uso de diferentes escalas para avaliação de nível de consciência. A escolha final entre escalas desse tipo deve considerar as características peculiares e condições da clientela a ser avaliada e não preferências individuais ou de departamentos de serviços de saúde.
Resumo:
Considerando que os idosos que utilizam múltiplos medicamentos são propensos à maior vulnerabilidade nas condições de saúde, propomo-nos, neste estudo: identificar os diagnósticos de enfermagem, segundo a taxonomia II de NANDA, de um grupo de idosos que utilizam cinco ou mais medicamentos. Foram selecionados 67 idosos, a partir da Avaliação Geriátrica Ampla (AGA) entre 301 residentes na área de abrangência de um Programa de Saúde da Família (PSF). Os 67 idosos apresentaram 16 categorias diagnósticas, em média 5,2 diagnósticos/idoso, sendo os mais frequentes a dor crônica, presente em 59,7% dos idosos; 58,2% têm a mobilidade física prejudicada; 47,7%, nutrição desequilibrada (mais que as necessidades corporais), e 47,7% têm um controle ineficaz do regime terapêutico. Tais diagnósticos revelam a necessidade de medidas envolvendo mudanças no estilo de vida, além do acompanhamento sistemático dessas pessoas.
Resumo:
Tämä insinöörityö tehtiin ABB Oy, Drivesin Product AC -tulosyksikön tuotekehitysosastolle Helsingissä. Työssä kehitettiin taajuusmuuttajien suorituskyvyn automaattinen testausympäristö. ABB:n taajuusmuuttajien suorituskykytestejä ei ole aikaisemmin automatisoitu. Testit on tehty käsin ja niiden suorittamiseen ja tulosten käsittelyyn on kulunut paljon aikaa. Automaattisella testauksella pyrittiin testien suorittamiseen ja tulosten käsittelyyn kuluvan ajan huomattavaan pienentymiseen. Työssä ei ollut tarkoituksena tehdä suorituskykytestejä vaan kehittää automaattinen testausympäristö eli suorituskykytestipenkki, jossa suorituskykytestit on mahdollista suorittaa. Työssä keskityttiin taajuusmuuttajan nopeus- ja momenttisäätäjien suorituskykyyn. Työ toteutettiin suunnittelu- ja ohjelmointityönä. Testausympäristön laitteisto perustuu ABB:n tuotekehityslaboratorioiden olemassaoleviin testipaikkoihin. Testausympäristössä käytetään taajuusmuuttajien lisäksi pääasiassa kolmivaiheisia oikosulkumoottoreita. Lisäksi laitteistoon kuuluu ACS800-sarjan taajuusmuuttaja kuormakäyttönä, momenttianturi ja takometri eli kierrosnopeusmittari. Ohjelmointi tehtiin National Instrumentsin LabVIEW-ohjelmointiympäristön versiolla 8.0. Testausympäristön käyttöliittymänä toimii saman yrityksen TestStand-testausohjelmiston versio 3.5. Testattavien taajuusmuuttajien ohjausta ja momenttianturin lukemista varten ohjelmoitiin virtuaali-instrumentteja. Virtuaali-instrumentteja kutsutaan TestStand-testisekvensseistä. Testisekvenssit luodaan TestStandin sekvenssieditorilla ja suoritetaan sekvenssieditorissa tai operaattorin käyttöliittymässä. Työn tuloksena syntyi taajuusmuuttajien suorituskyvyn automaattinen testausympäristö. Testausympäristöä voidaan hyödyntää sekä nykyisen että seuraavan sukupolven taajuusmuuttajien testauksessa. Sillä on mahdollista suorittaa yleisimmät taajuusmuuttajien suorituskykytestit, kuten nopeus- ja momenttisäätöjen staattinen ja dynaaminen tarkkuus, hyvin kattavasti. Testit voidaan automaattisesti suorittaa koko testikäytön sallimalla pyörimisnopeus- ja kuormitusalueella. Näytteenottotaajuus voi olla enintään 1 kHz luettaessa pyörimisnopeutta ACS800-sarjan taajuusmuuttajan kautta ja momenttianturia samanaikaisesti. Virtuaali-instrumenteista koostuvia testisekvenssejä voidaan vapaasti muokata ja kehittää testejä edelleen tai luoda kokonaan uusia testejä. Testausympäristö perustuu teollisuudessa yleisesti käytettyihin ohjelmistoihin ja tarjoaa hyvät mahdollisuudet jatkokehitykselle.