942 resultados para ultrasound guided nerveblock


Relevância:

40.00% 40.00%

Publicador:

Resumo:

In an experiment on one of the authors, we used ultrasound to visualise an acupuncture needle completely perforating the median nerve at the acupuncture point PC6. During this procedure only a slight sensation occurred, and no pain. We conclude that, in individual cases, the median nerve might be perforated without causing pain or neurological problems.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

BACKGROUND Patient-to-image registration is a core process of image-guided surgery (IGS) systems. We present a novel registration approach for application in laparoscopic liver surgery, which reconstructs in real time an intraoperative volume of the underlying intrahepatic vessels through an ultrasound (US) sweep process. METHODS An existing IGS system for an open liver procedure was adapted, with suitable instrument tracking for laparoscopic equipment. Registration accuracy was evaluated on a realistic phantom by computing the target registration error (TRE) for 5 intrahepatic tumors. The registration work flow was evaluated by computing the time required for performing the registration. Additionally, a scheme for intraoperative accuracy assessment by visual overlay of the US image with preoperative image data was evaluated. RESULTS The proposed registration method achieved an average TRE of 7.2 mm in the left lobe and 9.7 mm in the right lobe. The average time required for performing the registration was 12 minutes. A positive correlation was found between the intraoperative accuracy assessment and the obtained TREs. CONCLUSIONS The registration accuracy of the proposed method is adequate for laparoscopic intrahepatic tumor targeting. The presented approach is feasible and fast and may, therefore, not be disruptive to the current surgical work flow.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Background: EUS is being increasingly utilized for the diagnosis of choledocholithiasis and microlithiasis, especially in patients with biliary colic. Simultaneously, there is also a rising interest in the use of EUS for therapeutic interventions. Objectives: Our goal was to assess the effectiveness of EUS-directed common bile duct (CBD) stone removal to compare its safety and effectiveness with ERCP-directed intervention. Design: interim results of a prospective, randomized, single-center blinded clinical trial. Setting: A single tertiary care referral center. Patients: Fifty-two patients with uncomplicated CBD stones were prospectively randomized to CBD cannulation and stone removal under EUS or ERCP guidance. Main Outcome Measurements and Interventions: Primary outcome measure was the rate of successful cannulation of the CBD. Secondary Outcome measures included Successful removal of stones and overall complication rates. Results: CBD cannulation followed by stone extraction was successful in 23 of 26 patients (88.5%) in the EUS group (1) versus 25 of 26 patients (96.2%) in the ERCP group (11) (95% CI, -27.65%, 9.88%). Overall, there were 3 complications in the EUS group and 4 complications in the ERCP group. Limitation: The current study is an interim report from a single center report and performed by a single operator. Conclusions: Our preliminary analysis indicates that Outcomes following EUS-guided CBD stone retrieval are equivalent to those following ERCP EUS-related adverse events are similar to those following ERCP. ERCP and EUS-guided stone retrieval appears to be equally effective for therapeutic interventions of the bile duct. Additional studies are required to validate these preliminary results and to determine predictors of success of EUS-guided stone removal. (Gastrointest Endosc 2009;69:238-43.)

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Background: Patients without adequate abdominal-wall transillumination are at a high risk of developing complications after PEG. Objective: We evaluated the feasibility and utility of EUS to guide PEG in patients lacking abdominal-wall transillumination. Design: Single-center case series. Setting: Tertiary-referral center. Patients: Six patients who lacked adequate abdominal-wall transillumination and 2 patients with a large laparotomy scar deemed to be at high risk of developing complications after PEG. Interventions: Patients underwent EUS-guided PEG and deployment of a standard enteral feeding tube. Main Outcome Measurements: Technical success and complication rates. Results: PEG was Successful Under EUS guidance in 5 of 8 patients. Causes of failure included all inadequate EUS window because of a prior Billroth 1 gastrectomy in one and suspected bowel interposition in 2 patients. There were no complications. Limitations: A small number of patients, uncontrolled study, and short follow-up period. Conclusions: This technique may facilitate deployment of PEG in patients who lack adequate abdominal-wall transillumination.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Background and Aims: Endoscopic ultrasound (EUS) is useful for the treatment of sterile pancreatic fluid collections (PFC), either by means of transmural drainage or by complete aspiration. The aim of this study was to evaluate the efficacy and safety of single-step EUS-guided endoscopic approaches for treatment of sterile PFC. Patients and Methods: During a 3-year period, 77 consecutive patients with symptomatic, persistent sterile PFC were evaluated and treated with the linear EUS. We excluded patients with grossly purulent collections, chronic pseudocyst and those whose cytology diagnostic was neoplastic cyst of pancreas. 44 patients received a single 10-Fr plastic straight stent under EUS or fluoroscopic control (group I) and 33 of these underwent a single-step complete aspiration with a 19-gauge needle (group II). Results: The mean size of the sterile PFC was 48 mm in group I and 28 mm in group II (p < 0.001). Overall, endoscopic treatment was successful in 70 (90.9%) patients. The mean volume aspirated was 25 (18-65) ml. The total number of procedures was 50 in group I and 41 punctures in group II. After a mean follow-up of 64 +/- 15.6 weeks there were 6 complications 13.6%): 2 recurrences (referred to surgery), 2 developing abscesses (submitted a new EUS-guided endoscopic drainage with success), 1 perforation that died (2.2%), and 1 case of bleeding (sent to surgery) in group I. In group II there were only 6 (18.1%) recurrences (submitted a new EUS-guided aspiration). None of the patients undergoing single-step aspiration developed infections, perforation or hemorrhage. Conclusion: The recurrence of pancreatic pseudocysts after endoscopic treatment was similar, either by means of plastic stents or by complete single-step aspiration. Copyright (C) 2009 S. Karger AG, Basel

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Background: Kidney stone is a major universal health problem, affecting 10% of the population worldwide. Percutaneous nephrolithotomy is a first-line and established procedure for disintegration and removal of renal stones. Its surgical success depends on the precise needle puncture of renal calyces, which remains the most challenging task for surgeons. This work describes and tests a new ultrasound based system to alert the surgeon when undesirable anatomical structures are in between the puncture path defined through a tracked needle. Methods: Two circular ultrasound transducers were built with a single 3.3-MHz piezoelectric ceramic PZT SN8, 25.4 mm of radius and resin-epoxy matching and backing layers. One matching layer was designed with a concave curvature to work as an acoustic lens with long focusing. The A-scan signals were filtered and processed to automatically detect reflected echoes. Results: The transducers were mapped in water tank and tested in a study involving 45 phantoms. Each phantom mimics different needle insertion trajectories with a percutaneous path length between 80 and 150 mm. Results showed that the beam cross-sectional area oscillates around the ceramics radius and it was possible to automatically detect echo signals in phantoms with length higher than 80 mm. Conclusions: This new solution may alert the surgeon about anatomical tissues changes during needle insertion, which may decrease the need of X-Ray radiation exposure and ultrasound image evaluation during percutaneous puncture.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Background: An accurate percutaneous puncture is essential for disintegration and removal of renal stones. Although this procedure has proven to be safe, some organs surrounding the renal target might be accidentally perforated. This work describes a new intraoperative framework where tracked surgical tools are superimposed within 4D ultrasound imaging for security assessment of the percutaneous puncture trajectory (PPT). Methods: A PPT is first generated from the skin puncture site towards an anatomical target, using the information retrieved by electromagnetic motion tracking sensors coupled to surgical tools. Then, 2D ultrasound images acquired with a tracked probe are used to reconstruct a 4D ultrasound around the PPT under GPU processing. Volume hole-filling was performed in different processing time intervals by a tri-linear interpolation method. At spaced time intervals, the volume of the anatomical structures was segmented to ascertain if any vital structure is in between PPT and might compromise the surgical success. To enhance the volume visualization of the reconstructed structures, different render transfer functions were used. Results: Real-time US volume reconstruction and rendering with more than 25 frames/s was only possible when rendering only three orthogonal slice views. When using the whole reconstructed volume one achieved 8-15 frames/s. 3 frames/s were reached when one introduce the segmentation and detection if some structure intersected the PPT. Conclusions: The proposed framework creates a virtual and intuitive platform that can be used to identify and validate a PPT to safely and accurately perform the puncture in percutaneous nephrolithotomy.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Somatic post-surgical pain is invalidating and distressing to patients and carries the risk of important complications. The anterior abdominal wall is involved in most surgical procedures in general, gynecologic, obstetric, urological, vascular and pediatric surgery. Combined multimodal strategies involving nerve blocks, opiates, and non-steroidal anti-inflammatory drugs for systemic analgesia are necessary for optimal pain modulation. Anterior abdominal wall blocks, transverse abdominal plexus block, iliohypogastric and ilioinguinal nerveblock, genitofemoral nerve block and rectus sheath block have an important role as components of multimodal analgesia for somatic intraoperative and postoperative pain control. Ultrasound visualization has improved the efficacy and safety of abdominal blocks and implemented the application in the clinical setting. For this reason, they are a very important tool for all anesthesiologists who aim to treat effectively patients’ pain. This guide provides an evidence based comprehensive and necessary overview of anatomical, anesthesiological and technical information needed to safely perform these blocks.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Aortic stiffness is an independent predictor factor for cardiovascular risk. Different methods for determining pulse wave velocity (PWV) are used, among which the most common are mechanical methods such as SphygmoCor or Complior, which require specific devices and are limited by technical difficulty in obtaining measurements. Doppler guided by 2D ultrasound is a good alternative to these methods. We studied 40 patients (29 male, aged 21 to 82 years) comparing the Complior method with Doppler. Agreement of both devices was high (R = 0.91, 0.84-0.95, 95% CI). The reproducibility analysis revealed no intra-nor interobserver differences. Based on these results, we conclude that Doppler ultrasound is a reliable and reproducible alternative to other established methods for themeasurement of aortic PWV

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Purpose: Tumour-free resection margins (RMs) are mandatory in breast-conserving surgery. On-site intraoperative ultrasound (US)-guided tumour resection with extemporaneous histopathological assessment of RMs has been described. Remote intraoperative US assessment of RMs is an alternative. The purpose of this study was to evaluate the relationship of lumpectomy RMs measurements between remote intraoperative US and postoperative histopathology.Methods and Materials: In a retrospective IRB-approved review of 100 consecutive lumpectomies performed between October 2009 and April 2011 for presumed non-palpable breast cancer, 71 women (mean age 63.8years) were included. Twenty-nine patients were excluded because of absence of cancer at histopathology and/or incomplete data. Measurements of lumpectomy minimal RMs and tumour maximal diameter obtained on remote intraoperative US and postoperative histopathology were compared.Results: Minimal RMs were 0.35±0.32 (mean±SD) and 0.35±0.32cm on remote intraoperative US and postoperative histopathology, respectively. No significant difference was found between these measurements (p=0.37). Tumour maximal diameter was 1.02±0.51 (mean±SD) and 1.33±0.74cm on remote intraoperative US and postoperative histopathology, respectively. US measurements were significantly smaller (p<0.001). The 71 breast carcinoma (CA) consisted of: invasive canalar (n=49), invasive lobular (n=11), in situ (n=3) and other types of CA (n=8). Twenty-nine patients had intraoperative re-excision (24 without residual CA), while 16 patients were re-operated due to insufficient histopathological RMs (12 without residual CA).Conclusion: Good correlation of minimal RMs between remote intraoperative US and postoperative histopathology warrants use of both techniques in a complementary manner. Remote intraoperative US is helpful in taking rapid decision of re-excision and maintaining low re-operation rate after breast-conserving surgery for non-palpable cancer.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Objective: The present study was aimed at evaluating the contribution of transrectal prostate ultrasound in the screening for prostate neoplasias and in the guidance of prostate biopsies. Materials and Methods: Prospective study developed over a one-year period. All the patients with indication for prostate biopsy were evaluated. Regardless of PSA values, the patients underwent ultrasound in order to identify suspicious nodules (confirmed by two observers). Sextant biopsy was subsequently performed. In cases of finding suspicious nodules, an additional puncture directed to such nodules was done. Results: In a total of 155 cases the prevalence of malignancy was of 53%. Suspicious nodules were detected in 34 patients, and 25 where malignant (positive predictive value of 74%). The specificity and sensitivity for suspicious nodules were 88% and 31% respectively. Comparatively with the randomly obtained sextant specimens, the rate of findings of neoplasia was higher in the specimens obtained with puncture directed to the nodule (p = 0.032). No statistically significant difference was observed in the Gleason score for both types of specimens (p = 0.172). Conclusion: The high positive predictive value and the high rate of findings of neoplasia in specimens of suspicious nodules should be taken into consideration in the future. The authors suggest a biopsy technique similar to the one described in the present study (sextant biopsy plus puncture directed to the suspicious nodule).

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Abstract Objective: To propose an algorithm to determine the necessity for ultrasonography-guided fine-needle aspiration (US-FNA) in preoperative axillary lymph node staging of patients with invasive breast cancer. Materials and Methods: Prospective study developed at National Cancer Institute. The study sample included 100 female patients with breast cancer referred for axillary staging by US-FNA. Results: The overall US-FNA sensitivity was set at 79.4%. The positive predictive value was calculated to be 100%, and the negative predictive value, 69.5%. The US-FNA sensitivity for lymph nodes with normal sonographic features was 0%, while for indeterminate lymph nodes it was 80% and, for suspicious lymph nodes, 90.5%. In the assessment of invasive breast tumors stages T1, T2 and T3, the sensitivity was respectively 69.6%, 83.7% and 100%. US-FNA could avoid sentinel node biopsy in 54% of cases. Conclusion: Axillary ultrasonography should be included in the preoperative staging of all patients with invasive breast cancer. The addition of US-FNA in cases of lymph nodes suspicious for malignancy may prevent more than 50% of sentinel lymphadenectomies, significantly shortening the time interval to definitive therapy.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Purpose: To determine whether the use of ultrasound (US) to guide embryo transfer (ET) in a population previously defined as likely to have easy transfer would change the implantation and pregnancy rates in an ICSI program.Methods: A total of 100 patients identified as likely to have easy transfer after mock transfer were divided into two groups: Group I, US-guided ET (N = 50) and Group II, ET without the aid of US (N = 50).Results: Implantation and pregnancy rates were similar (p = 0.51, p = 0.29) for Group I (19.6%,42%) and Group II (16.3%,30%), as also was the abortion rate (p = 0.55) (Group I: 1/21; Group II: 2/15).Conclusion: As long as previous mock transfers are routinely performed during a cycle preceding assisted reproduction and the clinician considers transfer to be easy, ultrasound does not benefit the process of embryo transfer.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Ultrasound is considered the method of choice for evaluation of the gastrintestinal wall. Thickening of the wall is the most common ultrasonographic finding in gastric disorders. Inflammatory and neoplastic disorders are the most frequent causes of wall thickening. Case report 1: Boxer, with abdominal distension, ultrasound examination detected marked diffuse thickening of the gastric wall with loss of definition of wall layers. Fine needle aspiration guided by ultrasound diagnosed gastric carcinoma. Case report 2: mixed breed dog presenting oliguria, emesis and melena, the ultrasound examination showed diffuse thickening of the gastric wall, but with preserved layers and presence of calcification areas. An inflammatory process of the gastric wall was diagnosed using cytology. The distinction between inflammatory and neoplastic processes is performed based on several factors such as distribution, symmetry, size and architecture of the parietal layer in the lesions, and ultrasonography is a valuable tool to direct diagnosis and treatment.