976 resultados para transitive calibration


Relevância:

20.00% 20.00%

Publicador:

Resumo:

A 3 T superconducting magnet with a 70 mm diameter warm bore and energy storage of 47 kJ has been successfully fabricated and tested, which can be used to calibrate Hall sensors in high magnetic field as well as conduct superconducting experiments. The magnet consists of three solenoid coils and an iron yoke. The homogeneity of the magnetic field in the region of interest (ROI) is +/- 6.0 x 10(-5). The coils of the magnet were fabricated with NbTi-Cu superconducting wire and the stray magnetic field is shielded by an iron yoke. The coils and yoke are fully immersed in a helium vessel. The optimized structural design, stress and quench simulation, fabrication and test results are presented in this paper.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A method for calibration of an audio-frequency (AF) ion trap mass spectrometer is described. The method is proposed to surmount the obstacle that there is a lack of a proper calibrant for mass spectrometers in the mass-to-charge ratio (m/z) range of 10(6) to 10(10). To calibrate such mass spectra, we determine the point of ejection, q(eject), on the stability diagram of the ion trap operated in a mass-selective axial instability mode. This is accomplished by measuring the radial secular frequencies (and therefore, the m/z value) of a single trapped particle using a light scattering method, followed by monitoring the action of particle ejection in real time to obtain the q(eject). A delayed ejection with q(eject) = 0.949 +/- 0.004 is found at a trap driving frequency of Ohm/2pi = 200-600Hz. Theoretical analysis for the origin of the delayed ejection indicates that the delay is predominantly resulted from the existence of multipole components in the fields due to trap imperfections. Inclusion of -3% of the octopole with respect to the basic quadrupole field can satisfactorily account for our observations. An m/z accuracy approaching 0.1% is attainable after proper calibration of the AF ion trap mass spectrometer. (Int J Mass Spectrom 214 (2002) 63-73) (C) 2002 Elsevier Science B.V. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

It is shown that near-Nernstian calibration slopes can be obtained with a Cu1.8Se electrode in a range of cupric ion buffers in spite of a high chloride content. Best results are obtained with the ligands ethylenediamine, glycine and histidine. The onset of cupric ion toxicity towards marine organisms falls within the pCu calibration range obtained with glycine, and the Cu1.8Se electrode could, therefore, be useful for monitoring cupric ion activity in bioassays in sea-water media.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The procedure adopted by the Standard Seawater Service for the calibration of Standard Seawater in electrical conductivity relative to a defined potassium chloride solution is described

Relevância:

20.00% 20.00%

Publicador:

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A novel method is employed for the simultaneous determination of both the calibration constant of an electrochemical quartz crystal microbalance (EQCM) and the active surface area of a polycrystalline gold electrode. A gold electrode: is immersed into a 1 mM KI/1 M H2SO4 solution and on which forms a neutral monolayer. The adsorbed iodine can then be completely oxidized into IO3-. The active surface area of a gold electrode can be obtained from the net electrolytic charge of the oxidation process, and the calibration constant in the EQCM can be calculated from the corresponding frequency shift. The result shows that this method is simple, convenient and valid. (C) 2000 Elsevier Science S.A. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Traditional motion capture techniques, for instance, those employing optical technology, have long been used in the area of rehabilitation, sports medicine and performance analysis, where accurately capturing bio-mechanical data is of crucial importance. However their size, cost, complexity and lack of portability mean that their use is often impractical. Low cost MEMS inertial sensors when combined and assembled into a Wireless Inertial Measurement Unit (WIMU) present a possible solution for low cost and highly portable motion capture. However due to the large variability inherent to MEMS sensors, such a system would need extensive characterization to calibrate each sensor and ensure good quality data capture. A completely calibrated WIMU system would allow for motion capture in a wider range of real-world, non-laboratory based applications. Calibration can be a complex task, particularly for newer, multi-sensing range capable inertial sensors. As such we present an automated system for quickly and easily calibrating inertial sensors in a packaged WIMU, demonstrating some of the improvements in accuracy attainable.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Quantitative optical spectroscopy has the potential to provide an effective low cost, and portable solution for cervical pre-cancer screening in resource-limited communities. However, clinical studies to validate the use of this technology in resource-limited settings require low power consumption and good quality control that is minimally influenced by the operator or variable environmental conditions in the field. The goal of this study was to evaluate the effects of two sources of potential error: calibration and pressure on the extraction of absorption and scattering properties of normal cervical tissues in a resource-limited setting in Leogane, Haiti. Our results show that self-calibrated measurements improved scattering measurements through real-time correction of system drift, in addition to minimizing the time required for post-calibration. Variations in pressure (tested without the potential confounding effects of calibration error) caused local changes in vasculature and scatterer density that significantly impacted the tissue absorption and scattering properties Future spectroscopic systems intended for clinical use, particularly where operator training is not viable and environmental conditions unpredictable, should incorporate a real-time self-calibration channel and collect diffuse reflectance spectra at a consistent pressure to maximize data integrity.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Most studies that apply qualitative comparative analysis (QCA) rely on macro-level data, but an increasing number of studies focus on units of analysis at the micro or meso level (i.e., households, firms, protected areas, communities, or local governments). For such studies, qualitative interview data are often the primary source of information. Yet, so far no procedure is available describing how to calibrate qualitative data as fuzzy sets. The authors propose a technique to do so and illustrate it using examples from a study of Guatemalan local governments. By spelling out the details of this important analytic step, the authors aim at contributing to the growing literature on best practice in QCA. © The Author(s) 2012.