957 resultados para tracheal aspiration procedure
Resumo:
A sensitive and specific ultra performance liquid chromatography-tandem mass spectrometry method for the simultaneous quantification of nicotine, its metabolites cotinine and trans-3'-hydroxycotinine and varenicline in human plasma was developed and validated. Sample preparation was realized by solid phase extraction of the target compounds and of the internal standards (nicotine-d4, cotinine-d3, trans-3'-hydroxycotinine-d3 and CP-533,633, a structural analog of varenicline) from 0.5mL of plasma, using a mixed-mode cation exchange support. Chromatographic separations were performed on a hydrophilic interaction liquid chromatography column (HILIC BEH 2.1×100mm, 1.7μm). A gradient program was used, with a 10mM ammonium formate buffer pH 3/acetonitrile mobile phase at a flow of 0.4mL/min. The compounds were detected on a triple quadrupole mass spectrometer, operated with an electrospray interface in positive ionization mode and quantification was performed using multiple reaction monitoring. Matrix effects were quantitatively evaluated with success, with coefficients of variation inferior to 8%. The procedure was fully validated according to Food and Drug Administration guidelines and to Société Française des Sciences et Techniques Pharmaceutiques. The concentration range was 2-500ng/mL for nicotine, 1-1000ng/mL for cotinine, 2-1000ng/mL for trans-3'-hydroxycotinine and 1-500ng/mL for varenicline, according to levels usually measured in plasma. Trueness (86.2-113.6%), repeatability (1.9-12.3%) and intermediate precision (4.4-15.9%) were found to be satisfactory, as well as stability in plasma. The procedure was successfully used to quantify nicotine, its metabolites and varenicline in more than 400 plasma samples from participants in a clinical study on smoking cessation.
Resumo:
Application of cervical collars may reduce cervical spine movements but render tracheal intubation with a standard laryngoscope difficult if not impossible. We hypothesised that despite the presence of a Philadelphia Patriot (R) cervical collar and with the patient's head taped to the trolley, tracheal intubation would be possible in 50 adult patients using the GlideScope (R) and its dedicated stylet. Laryngoscopy was attempted using a Macintosh laryngoscope with a size 4 blade, and the modified Cormack-Lehane grade was scored. Subsequently, laryngoscopy with the GlideScope was graded and followed by tracheal intubation. All patients' tracheas were successfully intubated with the GlideScope. The median (IQR) intubation time was 50 s (43-61 s). The modified Cormack-Lehane grade was 3 or 4 at direct laryngoscopy. It was significantly reduced with the GlideScope (p < 0.0001), reaching grade 2a in most patients. Tracheal intubation in patients wearing a semi-rigid collar and having their head taped to the trolley is possible with the help of the GlideScope.
Resumo:
Background: Hirschsprung disease is characterized by the absence of intramural ganglion cells in the enteric plexuses, due to a fail during enteric nervous system formation. Hirschsprung has a complex genetic aetiology and mutations in several genes have been related to the disease. There is a clear predominance of missense/nonsense mutations in these genes whereas copy number variations (CNVs) have been seldom described, probably due to the limitations of conventional techniques usually employed for mutational analysis. In this study, we have looked for CNVs in some of the genes related to Hirschsprung (EDNRB, GFRA1, NRTN and PHOX2B) using the Multiple Ligation-dependent Probe Amplification (MLPA) approach. Methods: CNVs screening was performed in 208 HSCR patients using a self-designed set of MLPA probes, covering the coding region of those genes. Results: A deletion comprising the first 4 exons in GFRA1 gene was detected in 2 sporadic HSCR patients and in silico approaches have shown that the critical translation initiation signal in the mutant gene was abolished. In this study, we have been able to validate the reliability of this technique for CNVs screening in HSCR. Conclusions: The implemented MLPA based technique presented here allows CNV analysis of genes involved in HSCR that have not been not previously evaluated. Our results indicate that CNVs could be implicated in the pathogenesis of HSCR, although they seem to be an uncommon molecular cause of HSCR.
Resumo:
Immunoglobulin G4 (IgG4)-related fibroinflammatory systemic disease accounts for 7% of all noninfectious aneurysms of the thoracic aorta. A patient was admitted with a symptomatic ascending aortic aneurysm and thickened aortic wall (outer/inner diameter 55/45 mm), which was replaced. Probes revealed IgG4-related aortitis associated with a primary tuberculosis infection. Corticosteroid and antituberculosis therapies were used, and the patient's clinical evolution was favorable. The optimal treatment strategy of IgG4-related aortitis, a new entity, remains vague. Inner aortic diameter alone does not justify aortic replacement, but wall thickening may mimic intramural hematoma. In this particular case of IgG4-related aortitis, immunosuppressive treatment alone, as an alternative to a surgical procedure, may be debatable.
Resumo:
Background: In patients with cervical spine injury, a cervical collar may prevent cervical spine movements but renders tracheal intubation with a standard laryngoscope difficult if not impossible. We hypothesized that despite the presence of a semi-rigid cervical collar and with the patient's head taped to the trolley, we would be able to intubate all patients with the GlideScopeR and its dedicated stylet. Methods: 50 adult patients (ASA 1 or 2, BMI ≤35 kg/m2) scheduled for elective surgical procedures requiring tracheal intubation were included. After standardized induction of general anesthesia and neuromuscular blockade, the neck was immobilized with an appropriately sized semi-rigid Philadelphia Patriot® cervical collar, the head was taped to the trolley. Laryngoscopy was attempted using a Macintosh laryngoscope blade 4 and the modified Cormack Lehane grade was noted. Subsequently, laryngoscopy with the GlideScopeR was graded and followed by oro-tracheal intubation. Results: All patients were successfully intubated with the GlideScopeR and its dedicated stylet. The median intubation time was 50 sec [43; 61]. The modified Cormack Lehane grade was 3 or 4 at direct laryngoscopy. It was significantly reduced with the GlideScopeR (p <0.0001), reaching 2a in most of patients. Maximal mouth opening was significantly reduced with the cervical collar applied, 4.5 cm [4.5; 5.0] vs. 2.0 cm [1.8; 2.0] (p <0.0001). Conclusions: The GlideScope® allows oro-tracheal intubation in patients having their cervical spine immobilized by a semi-rigid collar and their head taped to the trolley. It furthermore decreases significantly the modified Cormack Lehane grade.
Resumo:
La pose d'un cathéter veineux central peut se faire par plusieurs abords. La connaissance de l'anatomie, du matériel, la maîtrise des détails de la procédure pour chaque type d'abord et une attention particulière à l'asepsie sont des prérequis importants pour limiter les risques de complications et pour donner une information complète et exhaustive au patient. Cet article peut être utilisé comme base pour le développement d'une check-list, utile pour les médecins qui doivent procéder à la pose d'un cathéter veineux central mais qui ne possèdent pas encore une maîtrise du geste. Several approaches exist for central vein catheterization. Mastery of the various steps of this procedure and understanding of the basics of asepsis are critical to prevent any complication. They also built the basis for an exhaustive communication with the patient, to obtain an informed consent. This article can in addition be used to develop a checklist in order to (self-)assess competence in procedural skills
Resumo:
The aim of this work was to evaluate a dot-enzyme-linked immunosorbent assay (dot-ELISA) using excretory-secretory antigens from the larval stages of Toxocara canis for the diagnosis of toxocariasis. A secondary aim was to establish the optimal conditions for its use in an area with a high prevalence of human T. canis infection. The dot-ELISA test was standardised using different concentrations of the antigen fixed on nitrocellulose paper strips and increasing dilutions of the serum and conjugate. Both the dot-ELISA and standard ELISA methods were tested in parallel with the same batch of sera from controls and from individuals living in the problem area. The best results were obtained with 1.33 µg/mL of antigen, dilutions of 1/80 for the samples and controls and a dilution of 1/5,000 for the anti-human IgG-peroxidase conjugate. All steps of the procedure were performed at room temperature. The coincidence between ELISA and dot-ELISA was 85% and the kappa index was 0.72. The dot-ELISA test described here is rapid, easy to perform and does not require expensive equipment. Thus, this test is suitable for the serological diagnosis of human T. canis infection in field surveys and in the primary health care centres of endemic regions.
Resumo:
Rabies is a neurotropic disease that is often lethal. The early diagnosis of rabies infection is important and requires methods that allow for the isolation of the virus from animals and humans. The present study compared a modified shell vial (MSV) procedure using 24-well tissue culture plates with the mouse inoculation test (MIT), which is considered the gold standard for rabies virus isolation. Thirty brain samples (25 positive and 5 negative by the fluorescent antibody test) obtained from different animal species at the National Institute of Hygiene Rafael Rangel in Caracas, Venezuela, were studied by the MIT and MSV assays. Nine samples (36%) were positive at 24 h, 10 (40%) were positive at 48 h and six (24%) were positive at 72 h by the MSV assay. With the MIT assay, 76% were positive at six days post inoculation and 12% were positive at 12 and 18 days post inoculation. One sample that was negative according to the MSV assay was positive with MIT on the 12th day. The MSV procedure exhibited a sensitivity of 96.2%, a specificity of 100%, a positive predictive value of 100% and a negative predictive value 80%. This procedure allowed for rapid rabies virus detection. MIT can be employed as an alternative method in laboratories without tissue culture facilities.
Resumo:
Background Surgery of radiation-induced cataracts in children with retinoblastoma (RB) is a challenge as early intervention is weighted against the need to delay surgery until complete tumour control is obtained. This study analyses the safety and functional results of such surgery. Methods In a retrospective, non-comparative, consecutive case series, we reviewed medical records of RB patients </=14 y of age who underwent either external beam radiotherapy or plaque treatment and were operated for radiation-induced cataract between 1985 and 2008. Results In total, 21 eyes of 20 RB patients were included and 18 out of the 21 eyes had Reese-Ellsworth stage V or ABC classification group D/E RB. Median interval between last treatment for RB and cataract surgery was 21.5 months, range 3-164 months. Phacoaspiration was performed in 13 eyes (61%), extra-capsular cataract extraction in 8 (39%) and intraocular lens implantation in 19 eyes (90%). The majority of cases, 11/21 (52%), underwent posterior capsulorhexis or capsulotomy and 6/21 (28%) an anterior vitrectomy. Postoperative visual acuity was >/=20/200 in 13 eyes and <20/200 in 5 eyes. Intraocular tumour recurrence was noted in three eyes. Mean postoperative follow up was 90 months+/-69 months. Conclusions Modern cataract surgery, including clear cornea approach, lens aspiration with posterior capsulotomy, anterior vitrectomy and IOL implantation is a safe procedure for radiation-induced cataract as long as RB is controlled. The visual prognosis is limited by initial tumour involvement of the macula and by corneal complications of radiotherapy. We recommend a minimal interval of 9 months between completion of treatment of retinoblastoma and cataract surgery.
Resumo:
There is controversy over the use of the Ross procedure with regard to the sub-coronary and root replacement technique and its long-term durability. A systematic review of the literature may provide insight into the outcomes of these two surgical subvariants. A systematic review of reports between 1967 and February 2013 on sub-coronary and root replacement Ross procedures was undertaken. Twenty-four articles were included and divided into (i) sub-coronary technique and (ii) root replacement technique. The 10-year survival rate for a mixed-patient population in the sub-coronary procedure was 87.3% with a 95% confidence interval (CI) of 79.7-93.4 and 89.1% (95% CI, 85.3-92.1) in the root replacement technique category. For adults, it was 94 vs 95.3% (CI, 88.9-98.1) and in the paediatric series it was 90 vs 92.7% (CI, 86.9-96.0), respectively. Freedom from reoperation at 10 years was, in the mixed population, 83.3% (95% CI, 69.9-93.4) and 93.3% (95% CI, 89.4-95.9) for sub-coronary versus root replacement technique, respectively. In adults, it was 98 vs 91.2% (95% CI, 82.4-295.8), and in the paediatric series 93.3 vs 92.0% (95% CI, 86.1-96.5) for sub-coronary versus root replacement technique, respectively. The Ross procedure arguably has satisfactory results over 5 and 10 years for both adults and children. The results do not support the advantages of the sub-coronary technique over the root replacement technique. Root replacement was of benefit to patients undergoing reoperations on neoaorta and for long-term survival in mixed series.
Resumo:
Measurement of three-dimensional (3D) knee joint angle outside a laboratory is of benefit in clinical examination and therapeutic treatment comparison. Although several motion capture devices exist, there is a need for an ambulatory system that could be used in routine practice. Up-to-date, inertial measurement units (IMUs) have proven to be suitable for unconstrained measurement of knee joint differential orientation. Nevertheless, this differential orientation should be converted into three reliable and clinically interpretable angles. Thus, the aim of this study was to propose a new calibration procedure adapted for the joint coordinate system (JCS), which required only IMUs data. The repeatability of the calibration procedure, as well as the errors in the measurement of 3D knee angle during gait in comparison to a reference system were assessed on eight healthy subjects. The new procedure relying on active and passive movements reported a high repeatability of the mean values (offset<1 degrees) and angular patterns (SD<0.3 degrees and CMC>0.9). In comparison to the reference system, this functional procedure showed high precision (SD<2 degrees and CC>0.75) and moderate accuracy (between 4.0 degrees and 8.1 degrees) for the three knee angle. The combination of the inertial-based system with the functional calibration procedure proposed here resulted in a promising tool for the measurement of 3D knee joint angle. Moreover, this method could be adapted to measure other complex joint, such as ankle or elbow.
Resumo:
The aim of this document is to provide general information about mIBG scintigraphy in cancer patients. The guidelines describe the mIBG scintigraphy protocol currently used in clinical routine, but do not include all existing procedures for neuroendocrine tumours. The guidelines should therefore not be taken as exclusive of other nuclear medicine modalities that can be used to obtain comparable results. It is important to remember that the resources and facilities available for patient care may vary from one country to another and from one medical institution to another. The present guidelines have been prepared for nuclear medicine physicians and intend to offer assistance in optimizing the diagnostic information that can currently be obtained from mIBG scintigraphy. The corresponding guidelines of the Society of Nuclear Medicine (SNM) and the Dosimetry, Therapy and Paediatric Committee of the EANM have been taken into consideration, and partially integrated into this text. The same has been done with the most relevant literature on this topic, and the final result has been discussed within a group of distinguished experts.
Resumo:
The combined 24-h energy expenditure (24-h EE) of mother and child was measured with a respiratory chamber (indirect calorimeter) in a group of 16 lactating Gambian women and was compared with that of a control group of 16 nonpregnant, nonlactating (NPNL) Gambian women. Breast-milk production (738 +/- 47 g/d: mean +/- SE) was adequate to allow a normal rate of growth of their 2-mo-old babies (28.0 +/- 2.4 g/d). The combined 24-h EE (mother and child) was higher (8381 +/- 180 kJ/d. P less than 0.001) than that of NPNL women (6092 +/- 121 kJ/d). Two-thirds of this differences could be attributed to the child's EE and one-third to a greater spontaneous physical activity of lactating women. The energy retained by the child for growth in conjunction with the calorimetric measurements allowed the calculation of the extra energy requirements for lactation, which were found to be 2100 kJ/d. These results confirm the values of the current dietary recommendations for lactation, based on the energy cost of milk production.