972 resultados para spray concentration reduction
Resumo:
Mossbauer spectroscopy was used in this study to investigate magnetite nanoparticles, obtained by spray pyrolysis and thermal treatment under H-2 reduction atmosphere. Room temperature XRD data indicate the formation of magnetite phase and a second phase (metallic iron) which amount increases as the time of reduction under H2 is increased. While room temperature Mossbauer data confirm the formation of the cubic phase of magnetite and the occurrence of metallic iron phase, the more complex features of 77 K-Mossbauer spectra suggest the occurrence of electronic localization favored by the different crystalline phase of magnetite at low temperatures which transition to the lower symmetry structure should occur at T similar to 120 K (Verwey transition).
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
In cases of decorative and functional applications, chromium results in protection against wear and corrosion combined with chemical resistance and good lubricity. However, pressure to identify alternatives or to improve conventional chromium electroplating mechanical characteristics has increased in recent years, related to the reduction in the fatigue strength of the base material and to environmental requirements. The high efficiency and fluoride-free hard chromium electroplating is an improvement to the conventional process, considering chemical and physical final properties. One of the most interesting, environmentally safer and cleaner alternatives for the replacement of hard chrome plating is tungsten carbide thermal spray coating, applied by the high velocity oxy-fuel (HVOF) process. The aim of this study was to analyse the effects of the tungsten carbide thermal spray coating applied by the HP/HVOF process and of the high efficiency and fluoride-free hard chromium electroplating (in the present paper called 'accelerated'), in comparison to the conventional hard chromium electroplating on the AISI 4340 high strength steel behaviour in fatigue, corrosion, and abrasive wear tests. The results showed that the coatings were damaging to the AISI 4340 steel behaviour when submitted to fatigue testing, with the tungsten carbide thermal spray coatings showing the better performance. Experimental data from abrasive wear tests were conclusive, indicating better results from the WC coating. Regarding corrosion by salt spray test, both coatings were completely corroded after 72 h exposure. Scanning electron microscopy technique (SEM) and optical microscopy were used to observe crack origin sites, thickness and adhesion in all the coatings and microcrack density in hard chromium electroplatings, to aid in the results analysis. © 2001 Elsevier Science B.V. All rights reserved.
Electrochemical reduction and voltammetric determination of diloxanide furoate in non-aqueous medium
Resumo:
The electrochemical reduction of diloxanide furoate (DF) in acetonitrile on glassy carbon electrode was studied in this work. It was observed that DF is reduced after a reversible one-electron transfer followed by an irreversible chemical reaction, diagnosed as C-Cl bond cleavage. Its reduction was followed by linear (LSV), differential pulse (DPV) and square wave voltammetry (SWV). Analytical curves were obtained for DF determination using all the investigated voltammetric techniques. For LSV was obtained a linear range (LR) from 5.0 × 10-4 to 1.0 × 10-2 mol L-1, with detection limit (DL) of 1.5 × 10-4 mol L-1 and sensitivity (S) of 2.1 × 104 μA mol-1 L. The analytical parameters obtained by DPV were: LR = 5.0 × 10-4 to 2.2 × 10-3 mol L-1, DL = 7.8 × 10-5 mol L-1, S = 3.7 × 104 μA mol-1 L. For SWV were obtained a LR = 7.5 × 10-6 to 1.2 × 10 -3 mol L-1, DL = 5.5 × 10-6 mol L -1 and S = 2.8 × 105 μA mol-1 L. Thus, the SWV was the most sensible technique, which can be used for DF determination at low concentration levels. Statistics methods were used to evaluate the analytical procedure, where recovery around to 100% was obtained for all voltammetric techniques. Relative standard deviations were lower than 5.0% (N=5). The obtained t values evaluating all the three voltammetric methods were less than the tabulated ones, indicating that there are no evidences of systematic error. ©2005 Sociedade Brasileira de Química.
Resumo:
Objective - To evaluate the effects of increasing doses of remifentanil hydrochloride administered via constant rate infusion (CRI) on the minimum alveolar concentration (MAC) of isoflurane in cats. Animals - 6 healthy adult cats. Procedures - For each cat, 2 experiments were performed (2-week interval). On each study day, anesthesia was induced and maintained with isoflurane; a catheter was placed in a cephalic vein for the administration of lactated Ringer's solution or remifentanil CRIs, and a catheter was placed in the jugular vein for collection of blood samples for blood gas analyses. On the first study day, individual basal MAC (MAC Basal) was determined for each cat. On the second study day, 3 remifentanil CRIs (0.25, 0.5, and 1.0 μg/kg/min) were administered (in ascending order); for each infusion, at least 30 minutes elapsed before determination of MAC (designated as MAC R0.25, MAC R0.5, and MAC R1.0, respectively). A 15-minute washout period was allowed between CRIs. A control MAC (MAC Control) was determined after the last remifentanil infusion. Results - Mean ± SD MAC Basal and MAC Control values at sea level did not differ significantly (1.66 ± 0.08% and 1.52 ± 0.21%, respectively). The MAC values determined for each remifentanil CRI did not differ significantly. However, MAC R0.25, MAC R0.5, and MAC R1.0, were significantly decreased, compared with MAC Basal, by 23.4 ± 79%, 29.8 ± 8.3%, and 26.0 ± 9.4%, respectively. Conclusions and Clinical Relevance - The 3 doses of remifentanil administered via CRI resulted in a similar degree of isoflurane MAC reduction in adult cats, indicating that a ceiling effect was achieved following administration of the lowest dose.
Resumo:
This work reports on the changes of performance of solid-state cells dye-sensitized solar cells with the variation of concentration of spiro-OMeTAD between 5% and 25% in the fabrication of the cell. Variations of charge recombination and capacitance correlate with the improvement of current-potential characteristics at increasing spiro-OMeTAD content, which is explained by reduction of transport resistance for hole transport, the increase of charge separation in the dye molecules, and importantly, with the increase of the β-factor in the recombination resistance, that causes a reduction of the diode ideality factor. © 2010 Materials Research Society.
Resumo:
This study reports the effects of dexmedetomidine on the minimum alveolar concentration of isoflurane (MAC iso) in cats. Six healthy adult female cats were used. MAC iso and dexmedetomidine pharmacokinetics had previously been determined in each individual. Cats were anesthetized with isoflurane in oxygen. Dexmedetomidine was administered intravenously using target-controlled infusions to maintain plasma concentrations of 0.16, 0.31, 0.63, 1.25, 2.5, 5, 10, and 20ng/mL. MAC iso was determined in triplicate at each target plasma dexmedetomidine concentration. Blood samples were collected and analyzed for dexmedetomidine concentration. The following model was fitted to the concentration-effect data: where MAC iso.c is MAC iso at plasma dexmedetomidine concentration C, MAC iso.0 is MAC iso in the absence of dexmedetomidine, I max is the maximum possible reduction in MAC iso, and IC 50 is the plasma dexmedetomidine concentration producing 50% of I max. Mean±SE MAC iso.0, determined in a previous study conducted under conditions identical to those in this study, was 2.07±0.04. Weighted mean±SE I max, and IC 50 estimated by the model were 1.76±0.07%, and 1.05±0.08ng/mL, respectively. Dexmedetomidine decreased MAC iso in a concentration-dependent manner. The lowest MAC iso predicted by the model was 0.38±0.08%, illustrating that dexmedetomidine alone is not expected to result in immobility in response to noxious stimulation in cats at any plasma concentration. © 2011 Blackwell Publishing Ltd.
Resumo:
The study aimed to evaluate the performance of air assistance in spray booms using different types of nozzles and spray volumes. We took into account spray deposits, fall armyworm control and crop corn performance in a narrow row cropping system. The experiment was carried out at the experimental area of Sao Paulo State University, Botucatu/SP, Brazil, during the 2008/2009 agricultural season, in randomized blocks with a factorial scheme (2×2+1) and four replications. Two spray nozzles (flat fan nozzle and hollow cone nozzle) were tested, combined with two air assistance levels in the spray boom (with and without air assistance) and a treatment control. In the experimental spraying, Spinosad insecticide was sprayed in amounts of 48 g active substance (a.s.)/ha. The air assistance in the spray boom increased the spray deposits in the V 4 growth stage of the corn plants. Moreover, the application of this technology showed higher efficiency on fall armyworm control, reaching a 100% level 15 days after spraying, in the V 10 growth stage of the plants. The hollow cone nozzle increased the spray deposit level on the corn plants compared with the flat fan nozzle, at growth stage V 4. However, the flat fan nozzle, combined with air assistance technology, was more effective for controlling fall armyworm in the same growth stage (V 4), although the hollow cone nozzle increased the deposit levels on the plants. All the technologies tested in the study promoted a reduction of plant damage from fall armyworm attack. Corn productivity is directly related to the control efficiency of fall armyworm.
Resumo:
Optimization of the major properties of anodes based on proton conductors, such as microstructure, conductivity and chemical stability, is yet to be achieved. In this study we investigated the influence of indium on the chemical stability, microstructural and electrical characteristics of proton conducting NiO-BaCe0.9-xInxY0.1O 3-δ (NiO-BCIYx) anodes. Four compositions of cermet anode substrates NiO-BCIYx were prepared using the method of evaporation and decomposition of solutions and suspensions (EDSS). Sintered anode substrates were reduced and their microstructural and electrical properties were examined before and after reduction as a function of the amount of indium. Anode substrates tested on chemical stability in the CO2 atmosphere showed high stability compared to anode substrates based on commonly used doped barium cerates. Microstructural properties of the anode pellets before and after testing in CO2 were investigated using X-ray diffraction analysis. Impedance spectroscopy measurements were used for evaluation of electrical properties of the anode pellets and the conductivity values of reduced anodes of more than 14 S cm-1 at 600 °C confirmed percolations through Ni particles. Under fuel cell operating conditions, the cell with a Ni-BCIY20 anode achieved the highest performance, demonstrating a peak power density 223 mW/cm2 at 700 °C confirming the functionality of Ni-BCIY anodes.© 2013 Elsevier B.V. All rights reserved.
Resumo:
Background: Artistic Gymnastics is a sport where athletes are frequently fatigued. One element that might influence this aspect is carbohydrate, an important energy substrate for the muscles and the CNS. Our goal was to investigate the influence of fatigue over artistic gymnastics athlete's performance and the effects of a carbohydrate supplementation on their performance. Methods: We evaluated 15 athletes divided in 2 groups (control and fatigue) from 12 to 14 years old in two different experimental days. On the first day (water day), they did 5 sets of exercises on the balance beam (experimental protocol) ingesting only water, CG (control group) warmed up before the experimental protocol and FG (fatigue group) did a fatigue circuit, warm up exercises and then the experimental protocol. On the second day (carbohydrate day), we used the same protocol but CG ingested a sugar free flavored juice and FG ingested a 20% concentration maltodextrin solution before the protocol on the balance beam. Results: We observed a greater number of falls from the balance beam from the FG on the first day (5.40 ± 1.14 FG vs 3.33 ± 1.37 CG; p = 0.024) and a decrease in the number of falls on the second day (2.29 ± 1.25 FG water day vs 5.40 ± 1.14 FG carbohydrate day; p = 0.0013). Carbohydrate solution was able to supply muscle demands and improve the athlete's focus showed by the reduced number of falls. © 2013 Batatinha et al.; licensee BioMed Central Ltd.
Resumo:
Objectives. To compare maternal flow-mediated dilation (FMD) of the brachial artery and nitrite concentration between third trimester of pregnancy (3rdT) and postpartum (PP) period. Additionally, we will evaluate whether FMD correlates with nitrite concentration in both periods. Methods. Eligibility criteria was healthy women with singleton pregnancy, gestational age >28 weeks, nonsmokers, and no personal or family history of vascular disease. Each women was examined during 3rdT and between 8 and 12 weeks PP to evaluate FMD and nitrite concentration in whole blood. Women not examined in both periods were excluded. Values between both periods were compared using paired t tests. Correlation between FMD and nitrite was examined by Pearson correlation coefficient. Significance level set as p<0.05. Results. We invited 42 pregnant women. Among them, 35 were eligible and 7 of them were excluded for not attending the PP evaluation resulting in 28 participants analyzed. We found no significant change in FMD (10.39±5.57% vs. 8.42±4.21%; p=0.11; 3rdT vs. PP, respectively) and no significant change in nitrite concentration (257.41±122.95nmol/L vs. 237.16±90.01nmol/L; p=0.28). Baseline brachial artery diameter had a significant reduction (3.11±0.30 to 2.75±0.34mm; p<0.01). No significant correlation between FMD and nitrite during 3rdT (r=-0.13; p=0.50) or PP (r=0.14; p=0.48) was found. Conclusions. We did not observe significant changes in both FMD and nitrite concentration between third trimester and the PP period. FMD did not correlate with nitrite in both periods. More studies are needed to confirm our findings. © Informa Healthcare USA, Inc.
Resumo:
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)
Resumo:
Pós-graduação em Agronomia (Produção Vegetal) - FCAV
Resumo:
Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)