886 resultados para screen plate
Resumo:
We expose the ubiquitous interaction between an information screen and its’ viewers mobile devices, highlights the communication vulnerabilities, suggest mitigation strategies and finally implement these strategies to secure the communication. The screen infers information preferences’ of viewers within its vicinity transparently from their mobile devices over Bluetooth. Backend processing then retrieves up-to-date versions of preferred information from content providers. Retrieved content such as sporting news, weather forecasts, advertisements, stock markets and aviation schedules, are systematically displayed on the screen. To maximise users’ benefit, experience and acceptance, the service is provided with no user interaction at the screen and securely upholding preferences privacy and viewers anonymity. Compelled by the personal nature of mobile devices, their contents privacy, preferences confidentiality, and vulnerabilities imposed by screen, the service’s security is fortified. Fortification is predominantly through efficient cryptographic algorithms inspired by elliptic curves cryptosystems, access control and anonymity mechanisms. These mechanisms are demonstrated to attain set objectives within reasonable performance.
Resumo:
A review dealing with the use of screen-printing technology to manufacture disposable electrodes is presented, covering in details virtually all the publications in the area up to early 1997 and including 206 references. The elements and different strategies on constructing modified electrodes are highlighted. Commercial and Home-made ink recipes are discussed. Microelectrode arrays, built by the combination of photostructuring and screen-printing technologies to the mass production of advanced disposable sensors, are also discussed. Future research trends are predicted.
Resumo:
Aim. To evaluate the usefulness of COOP/WONCA charts as a screening tool for mental disorders in primary care in the immigrant healthcare users in Salt. To measure self-rated health of Salt immigration population using the COOP / WONCA charts and to assess its associated factorsDesign. Descriptive and transversal study, Participants. 370 non-EU immigrants seniors selected by consecutive sampling stratified by sexMain measures. Personal information will be collected (age, sex, country of origin, years of residency in Spain, number of people living in the household and associated comorbidities). Each participant will complete the COOP/WONCA charts. An analysis of the validity of the diagnostic test will be done: sensibility, specificity, positive predictive value, negative predictive value, ROC curve and area under the curve (AUC). All variables will be subjected to descriptive analysis. Bivariate and multivariate analysis between the variables collected (sex, years of residency in Spain... ) and the results of COOP / WONCA charts will be performedResults. Preliminary results are available on a pilot test with 30 patients. The mental disorder prevalence is around 30%. Sensibility (0,89), specificity (0,89), VPP (0,80), VPN (0,94) cutoff score (3.5) and AUC (0,941). Women, people with 10 or more years of residency in Spain and unemployed people have worse self-rated healthConclusions. Based on the preliminary results, is possible to conclude that COOP/WONCA charts could be an useful, valid and applicable screening test for mental disorders in primary care with immigrant population
Resumo:
The purpose of the work was to realize a high-speed digital data transfer system for RPC muon chambers in the CMS experiment on CERN’s new LHC accelerator. This large scale system took many years and many stages of prototyping to develop, and required the participation of tens of people. The system interfaces to Frontend Boards (FEB) at the 200,000-channel detector and to the trigger and readout electronics in the control room of the experiment. The distance between these two is about 80 metres and the speed required for the optic links was pushing the limits of available technology when the project was started. Here, as in many other aspects of the design, it was assumed that the features of readily available commercial components would develop in the course of the design work, just as they did. By choosing a high speed it was possible to multiplex the data from some the chambers into the same fibres to reduce the number of links needed. Further reduction was achieved by employing zero suppression and data compression, and a total of only 660 optical links were needed. Another requirement, which conflicted somewhat with choosing the components a late as possible was that the design needed to be radiation tolerant to an ionizing dose of 100 Gy and to a have a moderate tolerance to Single Event Effects (SEEs). This required some radiation test campaigns, and eventually led to ASICs being chosen for some of the critical parts. The system was made to be as reconfigurable as possible. The reconfiguration needs to be done from a distance as the electronics is not accessible except for some short and rare service breaks once the accelerator starts running. Therefore reconfigurable logic is extensively used, and the firmware development for the FPGAs constituted a sizable part of the work. Some special techniques needed to be used there too, to achieve the required radiation tolerance. The system has been demonstrated to work in several laboratory and beam tests, and now we are waiting to see it in action when the LHC will start running in the autumn 2008.
Resumo:
This study illustrates the different types of plate heat exchangers that are commonly used in various domestic and industrial applications. The main purpose of this paper was to devise a methodology that is capable of calculating optimum number of plates in the design of a plate heat exchanger. To obtain the appropriate number of plates, typically several iterations must be made before a final acceptable design is completed, since plate amount depends on many factors such as, flow velocities, physical properties of the streams, flow channel geometry, allowable pressure drop, plate dimensions, and the gap between the plates. The methodology presented here can be used as a general guide for designing a plate heat exchanger. To investigate the effects of relevant parameters on the thermal-hydraulic design of a plate heat exchanger, several experiments were carried out for single-phase and counter flow arrangement with two brazed plate heat exchangers by varying the flow rates and the inlet temperatures of the fluid streams. The actual heat transfer coefficients obtained based on the experiment were nearly close to the calculated values and to improve the design, a correction factor was introduced. Besides, the effect of flow channel velocity on the pressure drop inside the unit is presented.
Resumo:
Engineering and pricing of large recovery boiler were studied in this work. Engineering was carried out with Anita 4.2 which is an engineering program of Andritz. Key initial values were chosen with previous studies. Primary target of this work was to find out the consequences that furnace dimensions and furnace screen vertical part has to boiler pricing. Boilers that were engineered had different rate of furnace width and depth and different heat transfer plate count. Boiler balances were invariable. Boilers with different vertical screen construction were also calculated. First variation was boiler with vertical screen up to furnace roof. Other variation was to connect vertical screen to Pre-boiler generating bank inlet tubes. Total prices were calculated to engineered boilers. Pricing was sort out to heat transfers, high pressure pipes, steel structures, auxiliary equipments and civil/structural costs. This study did not notice parts of the boiler which costs do not vary with the construction of the boiler. Heat transfers had the largest share of costs. Boiler building had the most significant differences between the boilers. Furnace screen had also significant role especially to costs of the boiler building.
Resumo:
Background: The relevance of persistent cognitive deficits to the pathogenesis and prognosis of bipolar disorders (BD) is understudied, and its translation into clinical practice has been limited by the absence of brief methods assessing cognitive status in Psychiatry. This investigation assessed the psychometric properties of the Spanish version of the Screen for Cognitive Impairment in Psychiatry (SCIP-S) for the detection of cognitive impairment in BD. Methods: After short training, psychiatrists at 40 outpatient clinics administered the SCIP three times over two weeks to a total of 76 consecutive type I BD admissions. Experienced psychologists also administered a comprehensive battery of standard neuropsychological instruments to clinical sample and 45 healthy control subjects. Results: Feasibility was supported by a brief administration time (approximately 15 minutes) and minimal scoring errors. The reliability of the SCIP was confirmed by good equivalence of forms, acceptable stability (ICC range 0.59 to 0.87) and adequate internal consistency (Chronbach's alpha of 0.74). Construct validity was granted by extraction of a single factor (accounting 52% of the variance), acceptable correlations with conventional neuropsychological instruments, and a clear differentiation between bipolar I and normal samples. Efficiency was also provided by the adequate sensitivity and specificity. Limitations: The sample size is not very large. The SCIP and the neurocognitive battery do not cover all potentially relevant cognitive domains. Also, sensitivity to change remains unexplored. Conclusion: With minimal training, physicians obtained a reliable and valid estimate of cognitive impairment in approximately 15 minutes from an application of the SCIP to type I BD patients.
Resumo:
Background: The relevance of persistent cognitive deficits to the pathogenesis and prognosis of bipolar disorders (BD) is understudied, and its translation into clinical practice has been limited by the absence of brief methods assessing cognitive status in Psychiatry. This investigation assessed the psychometric properties of the Spanish version of the Screen for Cognitive Impairment in Psychiatry (SCIP-S) for the detection of cognitive impairment in BD. Methods: After short training, psychiatrists at 40 outpatient clinics administered the SCIP three times over two weeks to a total of 76 consecutive type I BD admissions. Experienced psychologists also administered a comprehensive battery of standard neuropsychological instruments to clinical sample and 45 healthy control subjects. Results: Feasibility was supported by a brief administration time (approximately 15 minutes) and minimal scoring errors. The reliability of the SCIP was confirmed by good equivalence of forms, acceptable stability (ICC range 0.59 to 0.87) and adequate internal consistency (Chronbach's alpha of 0.74). Construct validity was granted by extraction of a single factor (accounting 52% of the variance), acceptable correlations with conventional neuropsychological instruments, and a clear differentiation between bipolar I and normal samples. Efficiency was also provided by the adequate sensitivity and specificity. Limitations: The sample size is not very large. The SCIP and the neurocognitive battery do not cover all potentially relevant cognitive domains. Also, sensitivity to change remains unexplored. Conclusion: With minimal training, physicians obtained a reliable and valid estimate of cognitive impairment in approximately 15 minutes from an application of the SCIP to type I BD patients.
Resumo:
Digitoitu 19. 9. 2008.
Resumo:
The focus of this dissertation is to develop finite elements based on the absolute nodal coordinate formulation. The absolute nodal coordinate formulation is a nonlinear finite element formulation, which is introduced for special requirements in the field of flexible multibody dynamics. In this formulation, a special definition for the rotation of elements is employed to ensure the formulation will not suffer from singularities due to large rotations. The absolute nodal coordinate formulation can be used for analyzing the dynamics of beam, plate and shell type structures. The improvements of the formulation are mainly concentrated towards the description of transverse shear deformation. Additionally, the formulation is verified by using conventional iso-parametric solid finite element and geometrically exact beam theory. Previous claims about especially high eigenfrequencies are studied by introducing beam elements based on the absolute nodal coordinate formulation in the framework of the large rotation vector approach. Additionally, the same high eigenfrequency problem is studied by using constraints for transverse deformation. It was determined that the improvements for shear deformation in the transverse direction lead to clear improvements in computational efficiency. This was especially true when comparative stress must be defined, for example when using elasto-plastic material. Furthermore, the developed plate element can be used to avoid certain numerical problems, such as shear and curvature lockings. In addition, it was shown that when compared to conventional solid elements, or elements based on nonlinear beam theory, elements based on the absolute nodal coordinate formulation do not lead to an especially stiff system for the equations of motion.
Resumo:
The main objective of this thesis is to show that plate strips subjected to transverse line loads can be analysed by using the beam on elastic foundation (BEF) approach. It is shown that the elastic behaviour of both the centre line section of a semi infinite plate supported along two edges, and the free edge of a cantilever plate strip can be accurately predicted by calculations based on the two parameter BEF theory. The transverse bending stiffness of the plate strip forms the foundation. The foundation modulus is shown, mathematically and physically, to be the zero order term of the fourth order differential equation governing the behaviour of BEF, whereas the torsion rigidity of the plate acts like pre tension in the second order term. Direct equivalence is obtained for harmonic line loading by comparing the differential equations of Levy's method (a simply supported plate) with the BEF method. By equating the second and zero order terms of the semi infinite BEF model for each harmonic component, two parameters are obtained for a simply supported plate of width B: the characteristic length, 1/ λ, and the normalized sum, n, being the effect of axial loading and stiffening resulting from the torsion stiffness, nlin. This procedure gives the following result for the first mode when a uniaxial stress field was assumed (ν = 0): 1/λ = √2B/π and nlin = 1. For constant line loading, which is the superimposition of harmonic components, slightly differing foundation parameters are obtained when the maximum deflection and bending moment values of the theoretical plate, with v = 0, and BEF analysis solutions are equated: 1 /λ= 1.47B/π and nlin. = 0.59 for a simply supported plate; and 1/λ = 0.99B/π and nlin = 0.25 for a fixed plate. The BEF parameters of the plate strip with a free edge are determined based solely on finite element analysis (FEA) results: 1/λ = 1.29B/π and nlin. = 0.65, where B is the double width of the cantilever plate strip. The stress biaxial, v > 0, is shown not to affect the values of the BEF parameters significantly the result of the geometric nonlinearity caused by in plane, axial and biaxial loading is studied theoretically by comparing the differential equations of Levy's method with the BEF approach. The BEF model is generalised to take into account the elastic rotation stiffness of the longitudinal edges. Finally, formulae are presented that take into account the effect of Poisson's ratio, and geometric non linearity, on bending behaviour resulting from axial and transverse inplane loading. It is also shown that the BEF parameters of the semi infinite model are valid for linear elastic analysis of a plate strip of finite length. The BEF model was verified by applying it to the analysis of bending stresses caused by misalignments in a laboratory test panel. In summary, it can be concluded that the advantages of the BEF theory are that it is a simple tool, and that it is accurate enough for specific stress analysis of semi infinite and finite plate bending problems.
Resumo:
The RPC Detector Control System (RCS) is the main subject of this PhD work. The project, involving the Lappeenranta University of Technology, the Warsaw University and INFN of Naples, is aimed to integrate the different subsystems for the RPC detector and its trigger chain in order to develop a common framework to control and monitoring the different parts. In this project, I have been strongly involved during the last three years on the hardware and software development, construction and commissioning as main responsible and coordinator. The CMS Resistive Plate Chambers (RPC) system consists of 912 double-gap chambers at its start-up in middle of 2008. A continuous control and monitoring of the detector, the trigger and all the ancillary sub-systems (high voltages, low voltages, environmental, gas, and cooling), is required to achieve the operational stability and reliability of a so large and complex detector and trigger system. Role of the RPC Detector Control System is to monitor the detector conditions and performance, control and monitor all subsystems related to RPC and their electronics and store all the information in a dedicated database, called Condition DB. Therefore the RPC DCS system has to assure the safe and correct operation of the sub-detectors during all CMS life time (more than 10 year), detect abnormal and harmful situations and take protective and automatic actions to minimize consequential damages. The analysis of the requirements and project challenges, the architecture design and its development as well as the calibration and commissioning phases represent themain tasks of the work developed for this PhD thesis. Different technologies, middleware and solutions has been studied and adopted in the design and development of the different components and a big challenging consisted in the integration of these different parts each other and in the general CMS control system and data acquisition framework. Therefore, the RCS installation and commissioning phase as well as its performance and the first results, obtained during the last three years CMS cosmic runs, will be
Resumo:
On this instrumental study we intend to analyse the factorial structure of the Screen for Child Anxiety Related Emotional Disorders (SCARED) in a Spanish sample using exploratory and confirmatory factorial analysis. As a second objective we intend to develop a short form of it for rapid screening and, finally, to analyze the reliabilities of both questionnaires. The SCARED was administered to a community sample of 1,508 children aged between 8 and 12 years. The sample was randomly split using half for the exploratory analysis and the other half for the confirmatory study. Furthermore a reduced version of the SCARED was developed using the SchmidLeiman procedure. Exploratory Factor Analysis yielded a four factor structure comprised of Somatic/panic, Generalized anxiety, Separation anxiety and Social phobia factors This structure was confirmed using Confirmatory Factor Analysis. The four factors, the full scale and the short scale showed good reliabilities. The results obtained seem to indicate that the Spanish version of the SCARED has good internal consistency, and along with other recent results, has a structure of four related factors that replicates the dimensions proposed for anxiety disorders by the DSM-IV-TR