993 resultados para repair resin composite


Relevância:

80.00% 80.00%

Publicador:

Resumo:

Pós-graduação em Odontologia Restauradora - ICT

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)

Relevância:

80.00% 80.00%

Publicador:

Resumo:

The objective of this study was to evaluate the effect of surface treatment with Er:YAG and Nd:YAG lasers on resin composite bond strength to recently bleached dentin. A total of 120 bovine incisors were distributed into two groups: C- without bleaching; and B- bleached with 35% hydrogen peroxide. Each group was divided into three subgroups: N- without laser treatment; Nd- Nd:YAG laser irradiation; and Er- Er:YAG laser irradiation. The adhesive system (Adper Single Bond 2) was applied and composite build-ups were constructed with Filtek Supreme (3M/ESPE). The teeth were sectioned to obtain dentin-resin sticks (1x1mm(2)) and tested by microtensile bond testing. The bond strength values in group B, subgroup N (16.1 +/- 3.5MPa) presented no significant difference compared with group B, subgroup Er (14.7 +/- 6.1MPa). Group C, subgroup N (26.8 +/- 7.4MPa) presented no significant difference compared with group B, subgroup Nd (28.8 +/- 5.6MPa). Group C, subgroup Nd (36.1 +/- 7.9MPa) presented a significant increase in bond strength compared with the other groups. The Er:YAG laser did not influence the bond strength of bleached specimens, and the use of the Nd:YAG laser on bleached specimens was able to reverse the immediate effects of bleaching, obtaining bond strength values similar to those of the control group.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

80.00% 80.00%

Publicador:

Resumo:

The usefulness of fluoride-releasing restorations in secondary caries prevention may be questioned because of the presence of other common sources of fluoride and because of ageing of the restorations. This study tested the hypothesis that glass-ionomer cement restorations, either aged or unaged, do not prevent secondary root caries, when fluoride dentifrice is frequently used. Sixteen volunteers wore palatal appliances in two phases of 14 days, according to a 2 x 2 crossover design. In each phase the appliance was loaded with bovine root dentine slabs restored with either glass-ionomer or resin composite, either aged or unaged. Specimens were exposed to cariogenic challenge 4 times/day and to fluoridated dentifrice 3 times/day. The fluoride content in the biofilm (FB) formed on slabs and the mineral loss (Delta Z) around the restorations were analysed. No differences were found between restorative materials regarding the FB and the Delta Z, for either aged (p = 0.792 and p = 0.645, respectively) or unaged (p = 1.00 and p = 0.278, respectively) groups. Under the cariogenic and fluoride dentifrice exposure conditions of this study, the glass-ionomer restoration, either aged or unaged, did not provide additional protection against secondary root caries. Copyright (c) 2006 S. Karger AG, Basel.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

This article presents details of fabrication, biological activity (i.e., anti-matrix metalloproteinase [anti-MMP] inhibition), cytocompatibility, and bonding characteristics to dentin of a unique doxycycline (DOX)-encapsulated halloysite nanotube (HNT)-modified adhesive. We tested the hypothesis that the release of DOX from the DOX-encapsulated nanotube-modified adhesive can effectively inhibit MMP activity. We incorporated nanotubes, encapsulated or not with DOX, into the adhesive resin of a commercially available bonding system (Scotchbond Multi-Purpose [SBMP]). The following groups were tested: unmodified SBMP (control), SBMP with nanotubes (HNT), and DOX-encapsulated nanotube-modified adhesive (HNT+DOX). Changes in degree of conversion (DC) and microtensile bond strength were evaluated. Cytotoxicity was examined on human dental pulp stem cells (hDPSCs). To prove the successful encapsulation of DOX within the adhesivesbut, more important, to support the hypothesis that the HNT+DOX adhesive would release DOX at subantimicrobial levelswe tested the antimicrobial activity of synthesized adhesives and the DOX-containing eluates against Streptococcus mutans through agar diffusion assays. Anti-MMP properties were assessed via -casein cleavage assays. Increasing curing times (10, 20, 40 sec) led to increased DC values. There were no statistically significant differences (p > .05) in DC within each increasing curing time between the modified adhesives compared to SBMP. No statistically significant differences in microtensile bond strength were noted. None of the adhesives eluates were cytotoxic to the human dental pulp stem cells. A significant growth inhibition of S. mutans by direct contact illustrates successful encapsulation of DOX into the experimental adhesive. More important, DOX-containing eluates promoted inhibition of MMP-1 activity when compared to the control. Collectively, our findings provide a solid background for further testing of encapsulated MMP inhibitors into the synthesis of therapeutic adhesives that may enhance the longevity of hybrid layers and the overall clinical performance of adhesively bonded resin composite restorations.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

To evaluate the effect of surface treatment with Er:YAG and Nd:YAG laser on resin composite bond strength to recently bleached dentin. Material and Methods: In this study 120 bovine incisors were used and distributed into two groups: Group C: without bleaching treatment; Group B: with bleaching treatment (35% hydrogen peroxide). Each group was divided into three subgroups: Subgroup N: without laser treatment; Subgroup Nd: irradiation with Nd:YAG laser; Subgroup Er: irradiation with Er:YAG laser. Next, the adhesive system (Adper Single Bond 2) was applied and composite buildups were constructed with Z350 composite. The teeth were sectioned to obtain dentin-resin sticks (1x1mm) and analyzed by microtensile bond testing. The data were statistically analyzed by the ANOVA and Tukey tests. Results: The results showed that the bond strength values in the bleached control group (16.17 MPa) presented no significant difference in comparison with the group bleached and irradiated with Er:YAG laser (14.69 MPa). The non bleached control group (26.79 MPa) presented significant difference in bond strength when compared with the non bleached group irradiated with Er:YAG laser (22.82 MPa) and with the group treated by bleaching and irradiation with Nd:YAG laser (28,792 MPa). The group without bleaching treatment and irradiated with Nd:YAG (36.1 MPa) presented a significant increase in bond strength in comparison with the other groups. Conclusion: The use of Nd:YAG laser on bleached specimens was able of completely reversing the immediate effects of bleaching, obtaining bond strength values similar to those of the control group

Relevância:

80.00% 80.00%

Publicador:

Resumo:

To evaluate the short-term response of human pulps to ethanol-wet bonding technique. Methods Deep class V cavities were prepared on 17 sound premolars and divided into three groups. After acid-etching, the cavities from groups 1 (G1) and 2 (G2) were filled with 100% ethanol or distilled water, respectively, for 60 s before the application of Single Bond 2. In group 3 (G3, control), the cavity floor was lined with calcium hydroxide before etching and bonding. All cavities were restored with resin composite. Two teeth were used as intact control. The teeth were extracted 48 h after the clinical procedures. From each tooth serial sections were obtained and stained with haematoxylin and eosin (H/E) and Masson's trichrome. Bacteria microleakage was assessed using Brown & Brenn. All sections were blindly evaluated for five histological features. Results Mean remaining dentine thickness was 463 ± 65 μm (G1); 425 ± 184 μm (G2); and 348 ± 194 μm (G3). Similar pulp reactions followed ethanol- or water-wet bonding techniques. Slight inflammatory responses and disruption of the odontoblast layer related to the cavity floor were seen in all groups. Stained bacteria were not detected in any cavities. Normal pulp tissue was observed in G3 except for one case. Conclusions After 48 h, ethanol-wet bonding does not increase pulpal damage compared to water-wet bonding technique. Clinical significance Ethanol-wet bonding may increase resin-dentine bond durability. This study reported the in vivo response of human pulp tissue when 100% ethanol was applied previously to an etch-and-rinse simplified adhesive system.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

The purpose was to evaluate the effect of acid etching time on the bond strength of a simplified etch-and-rinse adhesive system to noncarious and caries-affected dentin of primary and permanent teeth. Methods: Twenty-four extracted primary and permanent teeth were divided into three groups, according to the acid etching time. Four teeth from each group were exposed to a microbiological caries-inducing protocol. After caries removal, noncarious and caries-affected dentin surfaces were etched with 37 percent phosphoric acid for five, 10, or 15 seconds prior to the application of Prime & Bond NT adhesive. Crowns were restored with resin composite and prepared for microtensile testing. Data were submitted to Kruskal-Wallis and Mann-Whitney tests (á=0.05). Results: Higher bond strengths were obtained for noncarious dentin vs. cariesaffected dentin for both primary and permanent teeth. Reducing the acid etching time from 15 to five seconds did not affect the bond strength to caries-affected or noncarious dentin in primary teeth. For permanent teeth, lower bond strength values were observed when the noncarious dentin was etched for five seconds, while no difference was seen between 10 and 15 seconds. Conclusions: For Prime & Bond NT, the etching of dentin for five seconds could be recommended for primary teeth, while 10 seconds would be the minimum time for permanent teeth.