869 resultados para ray transform


Relevância:

20.00% 20.00%

Publicador:

Resumo:

The study of Electricity Markets operation has been gaining an increasing importance in the last years, as result of the new challenges that the restructuring produced. Currently, lots of information concerning Electricity Markets is available, as market operators provide, after a period of confidentiality, data regarding market proposals and transactions. These data can be used as source of knowledge, to define realistic scenarios, essential for understanding and forecast Electricity Markets behaviour. The development of tools able to extract, transform, store and dynamically update data, is of great importance to go a step further into the comprehension of Electricity Markets and the behaviour of the involved entities. In this paper we present an adaptable tool capable of downloading, parsing and storing data from market operators’ websites, assuring actualization and reliability of stored data.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Dissertação apresentada na Faculdade de Ciências e Tecnologia da Universidade Nova de Lisboa para a obtenção do grau de Mestre em Conservação e Restauro, especialização em pintura sobre tela

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In this paper, the fractional Fourier transform (FrFT) is applied to the spectral bands of two component mixture containing oxfendazole and oxyclozanide to provide the multicomponent quantitative prediction of the related substances. With this aim in mind, the modulus of FrFT spectral bands are processed by the continuous Mexican Hat family of wavelets, being denoted by MEXH-CWT-MOFrFT. Four modulus sets are obtained for the parameter a of the FrFT going from 0.6 up to 0.9 in order to compare their effects upon the spectral and quantitative resolutions. Four linear regression plots for each substance were obtained by measuring the MEXH-CWT-MOFrFT amplitudes in the application of the MEXH family to the modulus of the FrFT. This new combined powerful tool is validated by analyzing the artificial samples of the related drugs, and it is applied to the quality control of the commercial veterinary samples.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In this paper we propose a novel fully probabilistic solution to the stereo egomotion estimation problem. We extend the notion of probabilistic correspondence to the stereo case which allow us to compute the whole 6D motion information in a probabilistic way. We compare the developed approach against other known state-of-the-art methods for stereo egomotion estimation, and the obtained results compare favorably both for the linear and angular velocities estimation.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

New arguments proving that successive (repeated) measurements have a memory and actually remember each other are presented. The recognition of this peculiarity can change essentially the existing paradigm associated with conventional observation in behavior of different complex systems and lead towards the application of an intermediate model (IM). This IM can provide a very accurate fit of the measured data in terms of the Prony's decomposition. This decomposition, in turn, contains a small set of the fitting parameters relatively to the number of initial data points and allows comparing the measured data in cases where the “best fit” model based on some specific physical principles is absent. As an example, we consider two X-ray diffractometers (defined in paper as A- (“cheap”) and B- (“expensive”) that are used after their proper calibration for the measuring of the same substance (corundum a-Al2O3). The amplitude-frequency response (AFR) obtained in the frame of the Prony's decomposition can be used for comparison of the spectra recorded from (A) and (B) - X-ray diffractometers (XRDs) for calibration and other practical purposes. We prove also that the Fourier decomposition can be adapted to “ideal” experiment without memory while the Prony's decomposition corresponds to real measurement and can be fitted in the frame of the IM in this case. New statistical parameters describing the properties of experimental equipment (irrespective to their internal “filling”) are found. The suggested approach is rather general and can be used for calibration and comparison of different complex dynamical systems in practical purposes.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Pericardial cysts are rare benign congenital malformations, usually small, asymptomatic and detected incidentally on chest X-ray as a mass located in the right costophrenic angle. Giant pericardial cysts are very uncommon and produce symptoms by compressing adjacent structures. In this report, the authors present a case of a symptomatic giant pericardial cyst incorrectly diagnosed as dextrocardia on chest X-ray.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A presente dissertação tem com objetivo o desenvolvimento de um biossensor com base nos polímeros de impressão molecular para a deteção de uma molécula alvo, o ácido glutâmico que é convertido em glutamina pela glutamina sintetase, recorrendo à potenciometria. Nas células neoplásicas a glutamina não é sintetizada podendo-se considerar que o ácido glutâmico é um potencial agente anti-cancro. A técnica de impressão molécular utilizada foi a polimerização em bulk, combinando a acrilamida e a bis acrilamida com o ácido glutâmico. Para se verificar se a resposta potenciométrica obtida era de facto da molécula alvo foram preparados em paralelo com os sensores, materiais de controlo, ou seja, moléculas sem impressão molécular (NIP). Para se controlar a constituíção química dos vários sensores nomeadamente, do NIP e do polímero de impressão molecular (MIP) antes e após a remoção bem como a molécula foram realizados estudos de Espetroscopia de Infravermelhos de Transformada de Fourier (FTIR), Scanning electron microscope (SEM) e Espetroscopia de Raios X por dispersão em energia (EDS). Os materiais desenvolvidos foram aplicados em várias membranas que diferiam umas das outras, sendo seletivas ao ião. A avaliação das características gerais das membranas baseou-se na análise das curvas de calibração, conseguidas em meios com pHs diferentes, comparando os vários elétrodos. O pH 5 foi o que apresentou melhor resultado, associado a uma membrana que continha um aditivo, o p-tetra-octilphenol, e com o sensor com percentagem de 3%. Posto isto, testou-se em material biológico, urina, com as melhores características quer em termos de sensibilidade (18,32mV/década) quer em termos de linearidade (1,6x10-6 a 1,48x10-3 mol/L). Verificou-se ainda que aplicando iões interferentes na solução, estes não interferem nesta, podendo ser aplicados na amostra sem que haja alteração na resposta potenciométrica. O elétrodo é capaz de distinguir o ácido glutâmico dos restantes iões presentes na solução.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Ligand K-edge XAS of an [Fe3S4]0 model complex is reported. The pre-edge can be resolved into contributions from the í2Ssulfide, í3Ssulfide, and Sthiolate ligands. The average ligand-metal bond covalencies obtained from these pre-edges are further distributed between Fe3+ and Fe2.5+ components using DFT calculations. The bridging ligand covalency in the [Fe2S2]+ subsite of the [Fe3S4]0 cluster is found to be significantly lower than its value in a reduced [Fe2S2] cluster (38% vs 61%, respectively). This lowered bridging ligand covalency reduces the superexchange coupling parameter J relative to its value in a reduced [Fe2S2]+ site (-146 cm-1 vs -360 cm-1, respectively). This decrease in J, along with estimates of the double exchange parameter B and vibronic coupling parameter ì2/k-, leads to an S ) 2 delocalized ground state in the [Fe3S4]0 cluster. The S K-edge XAS of the protein ferredoxin II (Fd II) from the D. gigas active site shows a decrease in covalency compared to the model complex, in the same oxidation state, which correlates with the number of H-bonding interactions to specific sulfur ligands present in the active site. The changes in ligand-metal bond covalencies upon redox compared with DFT calculations indicate that the redox reaction involves a two-electron change (one-electron ionization plus a spin change of a second electron) with significant electronic relaxation. The presence of the redox inactive Fe3+ center is found to decrease the barrier of the redox process in the [Fe3S4] cluster due to its strong antiferromagnetic coupling with the redox active Fe2S2 subsite.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

J Biol Inorg Chem (2007) 12:353–366 DOI 10.1007/s00775-006-0191-9

Relevância:

20.00% 20.00%

Publicador:

Resumo:

J. Am. Chem. Soc., 2004, 126 (28), pp 8614–8615 DOI: 10.1021/ja0490222

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Dissertação para obtenção do Grau de Doutor em Bioquímica, Especialidade Bioquímica Estrutural

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Dissertação para obtenção do Grau de Doutor em Bioquímica – Ramo Bioquímica Estrutural