358 resultados para radionuclide
Resumo:
In forensic science, there is a strong interest in determining the post-mortem interval (PMI) of human skeletal remains up to 50 years after death. Currently, there are no reliable methods to resolve PMI, the determination of which relies almost exclusively on the experience of the investigating expert. Here we measured (90)Sr and (210)Pb ((210)Po) incorporated into bones through a biogenic process as indicators of the time elapsed since death. We hypothesised that the activity of radionuclides incorporated into trabecular bone will more accurately match the activity in the environment and the food chain at the time of death than the activity in cortical bone because of a higher remodelling rate. We found that determining (90)Sr can yield reliable PMI estimates as long as a calibration curve exists for (90)Sr covering the studied area and the last 50 years. We also found that adding the activity of (210)Po, a proxy for naturally occurring (210)Pb incorporated through ingestion, to the (90)Sr dating increases the reliability of the PMI value. Our results also show that trabecular bone is subject to both (90)Sr and (210)Po diagenesis. Accordingly, we used a solubility profile method to determine the biogenic radionuclide only, and we are proposing a new method of bone decontamination to be used prior to (90)Sr and (210)Pb dating.
Resumo:
Transaxial tomoscintigraphy (or single-photon emission computerised tomography) was used to detect secondary deposits of carcinoma in 17 patients who had been injected with iodine-131-labelled monoclonal antibodies against carcinoembryonic antigen. Of 17 tumor sites studied by tomoscintigraphy 16 were detected (sensitivity 94%); five sites had a volume smaller than 10 cm3. Tomoscintigraphy also detected three unknown tumour deposits later confirmed by surgery or radiology. In contrast, when 21 tumour sites in the same patients were studied by rectilinear scintigraphy, only nine tumour sites were detected (sensitivity 43%), of which eight had a volume larger than 50 cm3.
Resumo:
SEVERAL attempts have been made to show the specific localisation in vivo of anti-tumour antibodies. Most of these studies, however, either in experimental animals1,2 or in humans3 were performed with antibodies obtained by adsorption and elution from poorly characterised crude tumour fractions.
Resumo:
90Y-labelled radiopharmaceuticals offer promising prospects for radionuclide therapies of tumours, e.g. radioimmunotherapies (RIT), (EANM, 2007), peptide receptor radiotherapies (PRRT), (Otte et al., 1998), and selective internal radiotherapies (SIRT), (Salem and Thurston, 2006). 90Y, an almost pure high-energy beta radiation emitter (Eβ,max = 2.28 MeV), is a favourable radionuclide for therapeutic purposes. However, when preparing and performing these therapies, high activities of 90Y (>1 GBq) are to be manipulated and technicians, physicians and nurses may receive high skin exposures to the hands. If radiation protection standards are low, the exposure of staff can exceed the annual skin dose limit of 500 mSv. Within a particular work package (WP4) of the ORAMED project, comprehensive measurements in nuclear medicine departments of several hospitals in 6 European countries were carried out. The study focussed on 90Y-labelled substances such as Zevalin® and DOTATOC to achieve a representative database on staff exposure. This paper summarises the most important results and conclusions for individual monitoring of skin exposure of staff.
Resumo:
PURPOSE: In the radiopharmaceutical therapy approach to the fight against cancer, in particular when it comes to translating laboratory results to the clinical setting, modeling has served as an invaluable tool for guidance and for understanding the processes operating at the cellular level and how these relate to macroscopic observables. Tumor control probability (TCP) is the dosimetric end point quantity of choice which relates to experimental and clinical data: it requires knowledge of individual cellular absorbed doses since it depends on the assessment of the treatment's ability to kill each and every cell. Macroscopic tumors, seen in both clinical and experimental studies, contain too many cells to be modeled individually in Monte Carlo simulation; yet, in particular for low ratios of decays to cells, a cell-based model that does not smooth away statistical considerations associated with low activity is a necessity. The authors present here an adaptation of the simple sphere-based model from which cellular level dosimetry for macroscopic tumors and their end point quantities, such as TCP, may be extrapolated more reliably. METHODS: Ten homogenous spheres representing tumors of different sizes were constructed in GEANT4. The radionuclide 131I was randomly allowed to decay for each model size and for seven different ratios of number of decays to number of cells, N(r): 1000, 500, 200, 100, 50, 20, and 10 decays per cell. The deposited energy was collected in radial bins and divided by the bin mass to obtain the average bin absorbed dose. To simulate a cellular model, the number of cells present in each bin was calculated and an absorbed dose attributed to each cell equal to the bin average absorbed dose with a randomly determined adjustment based on a Gaussian probability distribution with a width equal to the statistical uncertainty consistent with the ratio of decays to cells, i.e., equal to Nr-1/2. From dose volume histograms the surviving fraction of cells, equivalent uniform dose (EUD), and TCP for the different scenarios were calculated. Comparably sized spherical models containing individual spherical cells (15 microm diameter) in hexagonal lattices were constructed, and Monte Carlo simulations were executed for all the same previous scenarios. The dosimetric quantities were calculated and compared to the adjusted simple sphere model results. The model was then applied to the Bortezomib-induced enzyme-targeted radiotherapy (BETR) strategy of targeting Epstein-Barr virus (EBV)-expressing cancers. RESULTS: The TCP values were comparable to within 2% between the adjusted simple sphere and full cellular models. Additionally, models were generated for a nonuniform distribution of activity, and results were compared between the adjusted spherical and cellular models with similar comparability. The TCP values from the experimental macroscopic tumor results were consistent with the experimental observations for BETR-treated 1 g EBV-expressing lymphoma tumors in mice. CONCLUSIONS: The adjusted spherical model presented here provides more accurate TCP values than simple spheres, on par with full cellular Monte Carlo simulations while maintaining the simplicity of the simple sphere model. This model provides a basis for complementing and understanding laboratory and clinical results pertaining to radiopharmaceutical therapy.
Resumo:
Depth-dose curves in LiF detectors of different effective thicknesses, together with their responses, were calculated for typical nuclear medicine radiation fields with 99mTc, 18F and 90Y sources. Responses were analysed in function of the radionuclide, detector effective thickness and irradiation geometry. On the other hand the results of the nuclear medicine measurement campaign of the ORAMED project were presented focussing on the dose distribution across the hand and on the appropriate position to wear the dosimeter.According to the results, thin LiF detectors provide better responses in all cases. Its use is essential for 18F, since thick dosimeters can underestimate Hp(0.07) up to a 50% because of the very inhomogeneous dose deposition on the active layer. The preliminary results of the measurement campaign showed that the index tip of the non-dominant hand is usually the most exposed position among the 22 monitored positions. It was also found that, in average, wrist dosimeters are likely to underestimate the maximum skin dose by a factor of the order of 20. This factor is reduced to around 6 for a ring dosimeter worn on the base of the index of the non-dominant hand. Thus, for typical nuclear medicine procedures, the base of the index of the non-dominant hand is recommended as the best monitoring option.
Resumo:
OBJECTIVE: To evaluate the pertinence of prenatal diagnosis in cases of congenital uropathy. STUDY DESIGN: Retrospective evaluation over a period of 6.5 years. METHOD: 93 cases were involved in the comparison of prenatal ultrasonographic diagnosis with neonatal findings, autopsy results, and follow-up data. RESULTS: 33 fetuses had renal parenchymal lesions, 44 had excretory system lesions, and 6 had bladder and/or urethral lesions. Seventy-three pregnancies lead to live births. Eighteen terminations of pregnancy were performed on the parents' request for extremely severe malformations. Two intrauterine deaths were observed, and two infants died in the postnatal period. Prenatal diagnosis was obtained at an average of 27 weeks gestation. Diagnostic concordance was excellent in 82% and partial in 12% of cases with renal parenchymal lesions; the false-positive rate was 6%. For excretory system lesions, concordance was excellent in 87% and partial in 7.4% of cases, with a false-positive rate of 5.6%. Finally, concordance was excellent in 100% of cases of bladder and/or urethral lesions. The overall rate of total concordance was 86%. Partial concordance cases consisted of malformations different from those previously diagnosed, but prenatal diagnosis nevertheless lead to further investigations in the neonatal period and to proper management. The false-positive diagnoses (5.4%) never lead to termination of pregnancy. CONCLUSION: Prenatal diagnosis of congenital uropathy is effective. A third-trimester ultrasonographic examination is necessary to ensure proper neonatal management, considering that the majority of cases are diagnosed at this gestational age.
Resumo:
The biodistribution of simultaneous intra-arterial and intravenous injections of a radiolabelled anti-CEA MAb F(ab')2 fragment was studied in three patients with liver metastases from colorectal cancer. Identical MAb fragments, labelled with either 125I or 131I, were injected over a period of 30 min into the hepatic artery and into a peripheral vein. After 1 or 2 days, biodistribution was measured in the surgically removed metastases, normal tissue samples and blood. By tissue radioactivity counting, tumour uptake in the range 6.3-9.1% of injected dose per gram was found. Superimposable metastasis-to-blood and metastasis-to-normal liver ratios were obtained for both iodine isotopes in all three patients. The results indicate that the intra-arterial injection of MAb F(ab')2 fragments gives no measurable advantage over more convenient injections into a peripheral vein.
Resumo:
Osteochondritis dissecans (OCD) is a joint disorder that affects the articular cartilage and subchondral bone, most commonly at the knee. OCD of the sacroiliac joint is extremely rare. Management of OCD remains controversial, and surgery is often needed, especially when conservative treatment fails. We present a rare case of OCD involving the left sacroiliac joint successfully treated by percutaneous computed tomography-guided retrograde drilling and debridement.
Resumo:
Preoperative imaging for resection of chest wall malignancies is generally performed by computed tomography (CT). We evaluated the role of (18)F-fluorodeoxyglucose (FDG) positron emission tomography (PET) in planning full-thickness chest wall resections for malignancies. We retrospectively included 18 consecutive patients operated from 2004 to 2006 at our institution. Tumor extent was measured by CT and PET, using the two largest perpendicular tumor extensions in the chest wall plane to compute the tumor surface assuming an elliptical shape. Imaging measurements were compared to histopathology assessment of tumor borders. CT assessment consistently overestimated the tumor size as compared to PET (+64% vs. +1%, P<0.001). Moreover, PET was significantly better than CT at defining the size of lesions >24 cm(2) corresponding to a mean diameter >5.5 cm or an ellipse of >4 cm x 7.6 cm (positive predictive value 80% vs. 44% and specificity 93% vs. 64%, respectively). Metabolic PET imaging was superior to CT for defining the extent of chest wall tumors, particularly for tumors with a diameter >5.5 cm. PET can complement CT in planning full-thickness chest wall resection for malignancies, but its true value remains to be determined in larger, prospective studies.
Resumo:
Use of radiolabeled nucleotides for tumor imaging is hampered by rapid in vivo degradation and low DNA-incorporation rates. We evaluated whether blocking of thymidine (dThd) synthesis by 5-fluoro-2'-deoxyuridine (FdUrd) could improve scintigraphy with radio-dThd analogues, such as 5-iodo-2'-deoxyuridine (IdUrd). We first show in vitro that coincubation with FdUrd substantially increased incorporation of [125I]IdUrd and [3H]dThd in the three tested human glioblastoma lines. Flow cytometry analysis showed that a short coincubation with FdUrd (1 h) produces a signal increase per labeled cell. We then measured biodistribution 24 h after i.v. injection of [125I]IdUrd in nude mice s.c. xenografted with the three glioblastoma lines. Compared with animals given [125I]IdUrd alone, i.v. preadministration for 1 h of 10 mg/kg FdUrd increased the uptake of [125I]IdUrd in the three tumors 4.8-6.8-fold. Compatible with previous reports, there were no side effects in mice observed for 2 months after receiving such a treatment. The tumor uptake of [125I]IdUrd was increased < or =13.6-fold when FdUrd preadministration was stepwise reduced to 1.1 mg/kg. Uptake increases remained lower (between 1.7- and 5.8-fold) in normal proliferating tissues (i.e., bone marrow, spleen, and intestine) and negligible in quiescent tissues. DNA extraction showed that 72-80% of radioactivity in tumor and intestine was bound to DNA. Scintigraphy of xenografted mice was performed at different times after i.v. injection of 3.7 MBq [125I]IdUrd. Tumor detection was significantly improved after FdUrd preadministration while still equivocal after 24 h in mice given [125I]IdUrd alone. Furthermore, background activity could be greatly reduced by p.o. administration of KClO4 in addition to potassium iodide. We conclude that FdUrd preadministration may improve positron or single photon emission tomography with cell division tracers, such as radio-IdUrd and possibly other dThd analogues.
Resumo:
Immunoscintigraphy (IS) consists of in vivo body structure imaging using a specific labelled antibody to an antigen concentrated in the structure under study. Technically, the image contrast is better when IS is performed with a computerized emission tomography system. High concentrations of carcinoembryonic antigen (CEA) have been reported in medullary thyroid carcinoma and thyroglobulin (Tg) is a marker for differentiated thyroid carcinoma. We used injections of 131-I labelled monoclonal antibodies to CEA and Tg to detect thyroid tumours. A feasibility trial using anti-CEA antibodies gave very encouraging results. However, only tumours larger than 10 cm3 could be detected. Contradictory results were obtained using anti-Tg antibodies but this data must be considered as preliminary. Various means of improving the method and the concept of accessibility of the antigen to the antibody in vivo are discussed. This study shows IS to be a promising experimental technique. Further studies are required to define its clinical indications before it can be advocated for routine use.