910 resultados para quantification géométrique


Relevância:

20.00% 20.00%

Publicador:

Resumo:

1. Extracts of the liver fluke, Fasciola hepatica from three different hosts (cow, sheep, rat) have been subjected to radioimmunoassay using antisera to 6 mammalian regulatory peptides.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

1. Tachykinin immunoreactivity has been localized, quantified and chromatographically-characterized in the brain, stomach, intestine and skin of Rana temporaria.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Purpose: To analyse the currently existing methods to infer the extent of cellular DNA damage induced by ionizing radiation when the pulsed field gel electrophoresis (PFGE) technique is used.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A sensitive and specific monoclonal ELISA for the determination of tissue bound furazolidone metabolite 3-amino-2-oxazolidinone (AOZ) is described. The procedure enables the detection of AOZ in matrix supernatant after homogenisation, protease treatment, acid hydrolysis and derivatisation of AOZ released from the tissue by o-nitrobenzaldehyde. The formed p-nitrophenyl 3-amino-2-oxazolidinone (NPAOZ) is determined by ELISA calibrated with matrix-matched standards in the concentration range of 0.05-5.0 mu g l(-1). The assay was validated according to criteria set down by Commission Decision 2002/657/EC for the performance and validation of analytical methods for chemical residues. Detection capability, set on the basis of acceptance of no false negative results, was 0.4 mu g kg(-1) for shrimp, poultry, beef and pork muscle. This sensitivity approaches the established confirmatory LC-MS/MS able to quantify tissue-bound AOZ at levels as low as 0.3 mu g kg(-1). An excellent correlation of results obtained by ELISA and LC/MS-MS within the concentration range 0-32.1 mu g kg(-1) was found in the naturally contaminated shrimp samples (r = 0.999, n = 8). A similar con-elation was found for the incurred poultry samples within the concentration range of 0-10.5 mu g kg(-1) (r = 0.99, n = 8). (c) 2005 Elsevier B.V All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

An increasing number of publications on the dried blood spot (DBS) sampling approach for the quantification of drugs and metabolites have been spurred on by the inherent advantages of this sampling technique. In the present research, a selective and sensitive high-performance liquid chromatography method for the concurrent determination of multiple antiepileptic drugs (AEDs) [levetiracetam (LVT), lamotrigine (LTG), phenobarbital (PHB)], carbamazepine (CBZ) and its active metabolite carbamazepine-10,11 epoxide (CBZE)] in a single DBS has been developed and validated. Whole blood was spotted onto Guthrie cards and dried. Using a standard punch (6. mm diameter), a circular disc was punched from the card and extracted with methanol: acetonitrile (3:1, v/v) containing hexobarbital (Internal Standard) and sonicated prior to evaporation. The extract was then dissolved in water and vortex mixed before undergoing solid phase extraction using HLB cartridges. Chromatographic separation of the AEDs was achieved using Waters XBridge™ C18 column with a gradient system. The developed method was linear over the concentration ranges studied with r=0.995 for all compounds. The lower limits of quantification (LLOQs) were 2, 1, 2, 0.5 and 1. µg/mL for LVT, LTG, PHB, CBZE and CBZ, respectively. Accuracy (%RE) and precision (%CV) values for within and between day were

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Purpose: The authors sought to quantify neighboring and distant interpoint correlations of threshold values within the visual field in patients with glaucoma. Methods: Visual fields of patients with confirmed or suspected glaucoma were analyzed (n = 255). One eye per patient was included. Patients were examined using the 32 program of the Octopus 1-2-3. Linear regression analysis among each of the locations and the rest of the points of the visual field was performed, and the correlation coefficient was calculated. The degree of correlation was categorized as high (r > 0.66), moderate (0.66 = r > 0.33), or low (r = 0.33). The standard error of threshold estimation was calculated. Results: Most locations of the visual field had high and moderate correlations with neighboring points and with distant locations corresponding to the same nerve fiber bundle. Locations of the visual field had low correlations with those of the opposite hemifield, with the exception of locations temporal to the blind spot. The standard error of threshold estimation increased from 0.6 to 0.9 dB with an r reduction of 0.1. Conclusion: Locations of the visual field have highest interpoint correlation with neighboring points and with distant points in areas corresponding to the distribution of the retinal nerve fiber layer. The quantification of interpoint correlations may be useful in the design and interpretation of visual field tests in patients with glaucoma.