913 resultados para photoelectronic device
Resumo:
Testing of a complex software is time consuming. Automated tools are available quite a lot for desktop applications, but for embedded systems a custom-made tool is required Building a complete test framework is a complicated task. Therefore, the test platform was built on top of an already existing tool, CANoe. CANoe is a tool for CAN bus analysis and node simulation. The functionality of CANoe was extended with LabVIEW DLL. The LabVIEW software was used for simulating hardware components of the embedded device As a result of the study, a platform was created where tests could be automated. Of the current test plan, 10 percent were automated and up to 60 percent could be automated with the current functionality.
Resumo:
Raspberry Pi is a low-cost computer created with educational purposes. It uses Linux and, most of times, freeware applications, particularly a software for viewing DICOM images. With an external monitor, the supported resolution (1920 × 1200 pixels) allows for the set up of simple viewing workstations at a reduced cost.
Resumo:
We present here the first part of the literature review regarding our study object, the Open Device Labs. The research on ODLs emerges from the observation of worldwide non-profit movement, which, through mutual collaboration, information and devices sharing, proposes a final improvement on user’s experience with the web and app.
Resumo:
A photometric procedure was developed for determination of aflatoxin B1 in peanuts by TLC-CCD technique. The quantification and detection limit were 1.2 μg kg-1 and 0.4 ng per spot, respectively, with mean recovery of 98%. The CCD camera is sufficiently sensitive to detect small changes in spots fluorescence intensity and the results for performance confirmed the efficiency of the method. Another important property of CCD detector is its linearity for a wide range of luminous stimulus determined by analysis of five-point calibration curves using the intensity of AFB1 fluorescence versus AFB1 concentration (0.8 to 4.8 ng per spot). The method was applied to the analysis of thirty nine peanut samples and aflatoxin B1 levels ranged from 16 to 115 μg kg-1. The TLC-CCD and the photometric procedure developed in this study demonstrated to be a simple and efficient tool for quantitative analyses of AFB1 in peanut samples.
Resumo:
This report describes a simple, inexpensive and highly effective instructional model based on the use of a tablet device to enable the real-time projection of the instructor's digitally handwritten annotations to teach chemistry in undergraduate courses. The projection of digital handwriting allows the instructor to build, present and adapt the class contents in a dynamic fashion and to save anything that is annotated or displayed on the screen for subsequent sharing with students after each session. This method avoids the loss of continuity and information that often occurs when instructors switch between electronic slides and white/chalk board during lessons. Students acknowledged that this methodology allows them to follow the instructor's cognitive process and the progressive development of contents during lectures as the most valuable aspect of the implemented instructional model.
Resumo:
Background: Pacemaker implantation (PMI) may predispose to venous thromboembolism (VTE) and obstruction (VO). This prospective study aimed at quantifying changes in venous calibers, and at determining the incidence of symptomatic and asymptomatic VTE/VO after PMI. Further goals included an assessment of the role of transesophageal echocardiography (TEE) in the diagnosis of lead-related central venous thrombi (CVT), and determination of predictors for VTE/VO. Methods: 150 (mean age 67; 61% male) consecutive patients with first PMI were enrolled and followed for 6 months. Contrast venography was performed at baseline and 6 months after PMI to measure venous diameters, and to detect stenosis, total occlusions and thrombi. TEE was conducted in 66 patients. Based on clinical suspicion, work-up for pulmonary embolism (PE) or acute deep vein thrombosis (DVT) were performed as needed. A total of 50 cases underwent longer-term (mean 2.4 years) follow-up venography. All cases with VTE/VO during the initial 6 months, and their matched controls, were selected for a case-control study focused on possible predictive role of laboratory and patient-related factors for the development of VTE/VO. Results: 10 (7 %) patients were found to have baseline venous abnormalities (e.g. 8 obstructions). Mean venous diameters diminished significantly during the first 6 months, but no further reduction occurred in late follow-up. New VO was discovered in 19 patients (14 %; 14 stenosis, 5 total occlusions; all asymptomatic). Small non-obstructive thrombi were found in 20/140 (14 %) 6-month venograms. TEE at 6 months disclosed CVT in 6 (9 %) patients. One (0.7 %) patient had acute symptomatic upper-extremity DVT, and PE was discovered in 5/150 (3.3 %) patients during the first 6 months with no further cases thereafter. At 6 months, the total number of cases with VTE/VO amounted to 47 (31.3 %). Additionally, the later 2-year venograms (n=50) disclosed 4 (8 %) total occlusions and 1 (2 %) stenosis. In the case-control study, no parameter was predictive of venous end-points as a single variable, but there appeared to be significant clustering of traditional VTE risk-factors among the cases. Laboratory parameters showed a definite acute hypercoagulative state induced by PMI, but its degree did not predict subsequent development of VTE/VO. Conclusions: This study shows that VTE/VO is relatively common after PMI with an overall incidence of at least 30 %. Although the majority of the lesions are asymptomatic and clinically benign, cases of PE were also encountered, and totally occluded veins may hamper future upgrading or replacement of pacing system. Venous complications seem difficult to prognosticate as firm predictors were not identified from a wide range of parameters analyzed in this study, although clustering of classic VTE risk factors may be a predisposing factor. Parameters related to implantation procedure or pacing systems and the severity of implantation-induced trauma did not emerge as predictors.
Resumo:
The subject being analyzed of this Master’s Thesis is a development of a service that is used to define a current location of a mobile device. The service utilized data that is obtained from own GPS receiver in some possible cases and as well data from mobile devices which can be afforded for the current environment for acquisition of more precise position of the device. The computation environment is based on context of a mobile device. The service is implemented as an application for communicator series Nokia N8XX. The Master’s Thesis presents theoretical concept of the method and its practical implementation, architecture of the application, requirements and describes a process of its functionality. Also users’ work with application is presented and recommendations for possible future improvements are made.
Resumo:
Recently most of the mobile phone manufacturer companies started to pay extra attention to their websites. This research investigates the sources of value creation on the mobile phone manufacturers’ website and the affect visiting the manufacturers’ website has on brand loyalty and brand satisfaction. The results show a correlation between positive website usage experience, brand loyalty and brand satisfaction. Moreover there is a relation between Novelty, Efficiency, Lock-in and the perceived usefulness the manufacturers’ website has on the mobile phone device. And finally the main reason behind Finnish student’s mobile phone brand loyalty is its country of origin.
Resumo:
Diplomityön tavoitteena oli kehittää Wipak Oy:n valmistamille sterilointipakkauksille tulevaisuuden pakkauskonsepti. Sterilointipakkaukset luokitellaan lääkelaitedirektiivin mukaan lisätarvikkeiksi luokan 1 lääkelaitteille, ja tämä näkökulma oli vahvasti mukana konseptin kehityksessä. Lähtökohtana pakkauskonseptin suunnittelulle oli tuotteiden arvoketjussa, eli pakata tuotteet siten että pakkausten avulla voidaan tuottaa lisäarvoa arvoketjun toimijoille. Tavoitteena oli parantaa pakkausten viestintää, toimivuutta/tehokkuutta toimitusketjussa sekä vahvistaa brändin imagoa myynti- ja kuljetuspakkauksen avulla. Lääkinnälliset laitteet ja tarvikkeet ovat lainsäädännön ja normien avulla tarkasti säädeltyjä. Näiden normien vaatimukset asettavat perusteet myynti- ja kuljetuspakkausten kehittämiselle. Tämän lisäksi suunnittelussa on huomioitu asiakkaiden toiveet ja kehitystarpeet. Kirjallisuusosuudessa on keskitytty lääkinnällisten laitteiden pakkausyksiköiden toimintoihin sekä niiden kehitysnäkymiin. Pääpaino on ollut pakkausmerkintöjen ja jäljitettävyyden kehittämisellä, koska tietojen automaattisen tunnistuksen hyödyntäminen lääkintälaitteiden pakkausten arvoketjussa on kasvava trendi. Manuaalisesti tehtävät tuotevirtojen kirjaukset ketjun eri toimijoiden osalta lisäävät riskejä jäljitettävyyden kannalta ja aiheuttavat lisätyötä ja – kustannuksia ketjun kaikille osapuolille. Ehdotus uudesta pakkauskonseptista on kehitetty näiden tietojen pohjalta. Ehdotuksessa on huomioitu lainsäädännöstä ja ketjun toimijoilta tulevat tarpeet, sekä alan tulevaisuuden kehitysnäkymät. Ehdotetun pakkauskonseptin avulla saadaan lisättyä myynti- ja kuljetuspakkausten tehokkuutta, parannettua jäljitettävyyttä ja helpotettu arvoketjun alavirran toimijoiden työtä lisäämällä erillinen sisäpakkaus myyntiyksikön sisälle. Työssä on lisäksi selvitetty pakkauskonseptin kustannusvaikutukset tuotteiden hintaan. Lopussa on ehdotettu jatkotoimenpiteet suunnitelman implementoimisesta käytäntöön.
Resumo:
Due to the importance of the environment on animal production and thus environmental control, the study aims to build a system for monitoring and control the meteorological variables, temperature and relative humidity, low cost, which can be associated with an evaporative cooling system (ECS). The system development included all the stages of assembly, test and laboratory calibration, and later the validation of the equipment carried in the field. The validation step showed results which allowed concluding that the system can be safely used in the monitoring of these variables. The controller was efficient in management of the microclimate in the waiting corral and allowed the maintenance of the air temperature within the comfort range for dairy cattle in pre-milking with averaged 25.09 ºC during the afternoon. The equipment showed the lower cost (R$ 325.76) when compared to other middle market (R$ 450.00).
Resumo:
OBJECTIVE: to present our experience with scheduled reoperations in 15 patients with intra-abdominal sepsis. METHODS: we have applied a more effective technique consisting of temporary abdominal closure with a nylon mesh sheet containing a zipper. We performed reoperations in the operating room under general anesthesia at an average interval of 84 hours. The revision consisted of debridement of necrotic material and vigorous lavage of the involved peritoneal area. The mean age of patients was 38.7 years (range, 15 to 72 years); 11 patients were male, and four were female. RESULTS: forty percent of infections were due to necrotizing pancreatitis. Sixty percent were due to perforation of the intestinal viscus secondary to inflammation, vascular occlusion or trauma. We performed a total of 48 reoperations, an average of 3.2 surgeries per patient. The mesh-zipper device was left in place for an average of 13 days. An intestinal ostomy was present adjacent to the zipper in four patients and did not present a problem for patient management. Mortality was 26.6%. No fistulas resulted from this technique. When intra-abdominal disease was under control, the mesh-zipper device was removed, and the fascia was closed in all patients. In three patients, the wound was closed primarily, and in 12 it was allowed to close by secondary intent. Two patients developed hernia; one was incisional and one was in the drain incision. CONCLUSION: the planned reoperation for manual lavage and debridement of the abdomen through a nylon mesh-zipper combination was rapid, simple, and well-tolerated. It permitted effective management of severe septic peritonitis, easy wound care and primary closure of the abdominal wall.
Resumo:
The authors present a especially constructed, lightweight, collapsible, portable and low cost model device for skills training in laparoscopic.