688 resultados para pedicle screw


Relevância:

10.00% 10.00%

Publicador:

Resumo:

Trabalho Final de Mestrado para obtenção do grau de Mestre em Engenharia Mecânica

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Fungal contamination in composting facilities has been associated with increased respiratory and skin pathologies among compost workers. In this study we aim to characterize the fungal contamination caused by Aspergillus genera within a totally indoor composting plant located in Portugal. Air samples of 50L were collected from 6 sampling sites through an impaction method. Surfaces samples were collected by swabbing the surfaces of the same indoor sites. Pre-treatment and waste screw were the sampling sites of the analyzed composting plant with the highest Aspergillus load in the air. Globally, the genus Aspergillus presented the highest prevalence both in the air from (90.6%), and surfaces from the same sampling sites (60.8%). The results obtained in this study claim the attention to the need of further research regarding the fungal contamination dur to Aspergillus genus in composting plants.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Os objectivos principais deste estudo são a caracterização de uma das linhas de extrusão existentes na Cabelte, nomeadamente a linha de extrusão de referência EP5, composta por duas extrusoras. Pretende-se fazer a determinação de indicadores energéticos e de processo e a optimização do consumo energético, no que diz respeito à energia consumida e às perdas térmicas relativas a esta linha. Para fazer a monitorização da linha de extrusão EP5 foi colocado no quadro geral dessa linha um equipamento central de medida de forma a ser possível a sua monitorização. No entanto, para a extrusora auxiliar as medições foram efectuadas com uma pinça amperimétrica e um fasímetro. Foram também efectuados ensaios onde foi avaliada a quantidade de material transformada, para isso foi utilizado um equipamento de pesagem, doseador gravimétrico aplicado nas extrusoras. As medições de temperatura para os cálculos das perdas térmicas da extrusora principal e para a caracterização dos materiais plásticos, foram efectuadas utilizando um termómetro digital. Foram efectuados ensaios de débito às extrusoras auxiliar e principal e foi estudada a variação do factor de potência em função da rotação do fuso. Na perspectiva do utilizador final a optimização para a utilização racional de energia está na redução de encargos da factura de energia eléctrica. Essa factura não depende só da quantidade mas também do modo temporal como se utiliza essa energia, principalmente a energia eléctrica, bastante dependente do período em que é consumida. Uma metodologia diferente no planeamento da produção, contemplando o fabrico dos cabos com maior custo específico nas horas de menor custo energético, implicaria uma redução dos custos específicos de 18,7% para o horário de verão e de 20,4% para o horário de inverno. Os materiais de revestimento utilizados (PE e PVC), influenciam directamente os custos energéticos, uma vez que o polietileno (PE) apresenta sempre valores de entalpia superiores (0,317 kWh/kg e 0,281 kWh/kg)) e necessita de temperaturas de trabalho mais elevadas do que o policloreto de vinilo (PVC) (0,141 kWh/kg e 0,124 kWh/kg). O consumo específico tendencialmente diminui à medida que aumenta a rotação do fuso, até se atingir o valor de rotação óptimo, a partir do qual esta tendência se inverte. O cosφ para as duas extrusoras em estudo, aumenta sempre com o aumento de rotação do fuso. Este estudo permitiu avaliar as condições óptimas no processo de revestimento dos cabos, de forma a minimizarmos os consumos energéticos. A redução de toda a espécie de desperdícios (sobre consumos, desperdício em purgas) é uma prioridade de gestão que alia também a eficácia à eficiência, e constitui uma ferramenta fundamental para assegurar o futuro da empresa. O valor médio lido para o factor de potência (0,38) da linha EP5, valor extremamente baixo e que vem associado à energia reactiva, além do factor económico que lhe está inerente, condiciona futuras ampliações. A forma de se corrigir o factor de potência é instalando uma bateria de condensadores de 500 kVAr. Considerando o novo sistema tarifário aplicado à energia reactiva, vamos ter um ganho de 36167,4 Euro/ano e o período de retorno de investimento é de 0,37 ano (4,5 meses). Esta medida implica também uma redução anual na quantidade de CO2 emitida de 6,5%. A quantificação das perdas térmicas é importante, pois só desta forma se podem definir modos de actuação de forma a aumentar a eficiência energética. Se não existir conhecimento profundo dos processos e metodologias correctas, não podem existir soluções eficientes, logo é importante medir antes de avançar com qualquer medida de gestão.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Trabalho Final de Mestrado para obtenção do grau de Mestre em Engenharia Mecânica

Relevância:

10.00% 10.00%

Publicador:

Resumo:

A low cost method (LCM) to produce a gaseous environment for the isolation of Helicobacter pylori, was compared with the standard Gas Park system. The LCM uses a carbonated antacid tablet, a plastic bag with tap water, a candle, and a wide-mouthed glass jar provided with a tight-fitting metalic screw cap and a rubber gasket. Antral gastric biopsies from 153 cases were incubated by duplicate on blood agar plates and treated with the two methods. In 95 cases the agent was isolated from both, and only from the standard method in 10 cases; the opposite condition was found in five cases, and 43 were negative. That difference is not significant (Pearson's X²= 93.25 p > 0,05)

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Na presente dissertação é proposto o desenvolvimento de um novo sistema de calibração de roscados de exteriores através de visão computacional. A calibração de roscados de exterior consiste na obtenção do diâmetro efectivo, do diâmetro exterior e do passo, e no cálculo da incerteza expandida correspondente. Actualmente, a calibração é efectuada com o auxílio de máquinas universais (SIP), na qual o diâmetro efectivo é obtido através de um modelo matemático, pois não se consegue obtê-lo directamente. O sistema de calibração por visão computacional tem como objectivo obter-se o diâmetro efectivo directamente, assim como as restantes características. A vantagem deste novo sistema será para roscados com dimensões inferiores a 2 mm, que não se conseguem medir utilizando a SIP. A desvantagem é referente a diâmetros superiores a 2 mm, devido à resolução obtida com a câmara utilizada. Este sistema foi validado por comparação com a calibração utilizando como equipamento calibrador a SIP. Ao longo da dissertação irão ser explicados todos os passos dados para a calibração de roscados de exterior.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Exenteration of the orbit is a disfiguring and destructive procedure; it is generally performed for orbital malignancies and often provides a significant reconstructive challenge. Our purpose was to evaluate the clinical indications for orbital exenteration in a tertiary referral center and to assess the reconstructive options employed. A retrospective nonrandomized analysis was performed, selecting all patients undergoing orbital exenteration over a 5-year period, between January 2005 and January 2010. Patient demographics, tumor characteristics, and reconstructive techniques used were evaluated. Twenty patients with a mean age of 76.5 years underwent total orbital exenteration. Basal cell carcinoma was the main operative indication (45%), followed by squamous cell carcinoma (15%). Reconstructive techniques included cover of the raw orbital cavity with a temporal muscular flap in all cases followed with split skin grafting (25%), bilaterally pedicle V-Y advancement flap (10%) and a fasciocutaneous island flap of the retroauricular region (65%). Twenty percent of patients had local complications and all were treated in a satisfactory fashion. Eyelid skin tumors remain an important cause of orbital exenteration. Temporal muscle flap is a reliable and stable reconstructive solution after orbital exenteration and additional aid is supplied with skin grafts or local flaps. This technique ensures a good aesthetic outcome and better situation for later complementary treatments and minimal associated donor site morbidity.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Flexor hallucis longus (FHL) transfer is a well-established treatment option in failed Achilles tendon (AT) repair and has been routinely performed as an open procedure. We detail the surgical steps needed to perform an arthroscopic transfer of the FHL for a chronic AT rupture. The FHL tendon is harvested as it enters in its tunnel beneath the sustentaculum tali; a tunnel is then drilled in the calcaneus as near to the AT footprint as possible. By use of a suture-passing device, the free end of the FHL is advanced to the plantar aspect of the foot. After adequate tension is applied to the construct, the tendon is fixed in place with an interference screw in an inside-out fashion. This minimally invasive approach is a safe and valid alternative to classic open procedures with the obvious advantages of preserving the soft-tissue envelope and using a biologically intact tendon.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

With the purpose of standardization of an hemoculture technique presenting a higher positive rate in the parasitological diagnosis of chronic Chagas' disease in patients with reactive serology (IFT, HA, CFT) the following schedule was used. Thirty ml of venous blood was collected with heparin and the plasma was separated by centrifugation (2.000 rpm/30'). The packed cells were washed with LIT medium or PBS which was then removed by centrifugation (2.000 rpm/15'). This material was sampled in 6 screw-tubes 18x200 with 6 ml of LIT medium and incubated at 28°C. These incubated cultures at 28°C were examined after 15, 30, 45 and 60 days. When the hemoculture was not immediately processed after blood collection, the plasma was removed and the sediment enriched with LIT medium and preserved at 4°C. The Xenodiagnosis was performed according to Schenones method used here as a reference technique. Among the various groups of patients examined by both techniques the best results obtained were: 55.08% ofpositivity for hemocultures against 27.5% forxenodiagnosis (X² = 4.54, p = 0.05), with a tubepositivity of 26.6%. Recommendation for screening trials of drug assays is the repetition of method on a same patient 2 or more times in different occasions, as used in xenodiagnosis.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The contribution of the sternocleidomastoid branch of the occipital artery (superior arterial pedicle - SAP) to the irrigation of the sternocleidomastoid muscle (SCM) was evaluated in fresh human cadavers by injecting radiological dye and a resin for microvasculature corrosion casts. From its insertion in the mastoid process of the temporal bone, the SCM was divided into superior, medium, and inferior thirds. In most of the SCM, The SAP are formed by two longitudinal parallel branches. In all specimens, the radiological dye injected into the SAP reached or trespassed the middle part of the studied SCM. The SAP was poorly distributed in the lowermost region of the inferior third of the SCM, suggesting the contribution of other arteries or pedicles. The corrosion casts of the microvasculature showed a profuse network of microscopic vessels in those levels where the SAP was detected.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Allthough infrequent, digestive fistulae in HIV/AIDS patients have been reported throughout the digestive tract from the esophagus to the anus, with predominance of esophageal fistulae. AIDS/HIV-associated opportunistic infections may invade the digestive system and lead to fistula formation. Tuberculosis is the most common infection associated with these esophageal fistulae. We report here one case of bile duct-duodenal fistula in a female AIDS patient with associated abdominal Mycobacterium tuberculosis infection compromising lymphnodes of the hepatic pedicle where the fistula was found. According to the reviewed literature, this is the third case of bile duct-duodenal fistula associated with abdominal tuberculosis in AIDS patient, and the first where both the fistula and the tuberculosis infection were diagnosed at laparotomy for acute abdomen. Whether the AIDS patient with abdominal pain needs or not a laparotomy to treat an infectious disease is often a difficult matter for the surgeon to decide, as most of the times appropriate medical treatment will bring more benefit.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

As increasingly more sophisticated materials and products are being developed and times-to-market need to be minimized, it is important to make available fast response characterization tools using small amounts of sample, capable of conveying data on the relationships between rheological response, process-induced material structure and product characteristics. For this purpose, a single / twin-screw mini-extrusion system of modular construction, with well-controlled outputs in the range 30-300 g/h, was coupled to a in- house developed rheo-optical slit die able to measure shear viscosity and normal-stress differences, as well as performing rheo-optical experiments, namely small angle light scattering (SALS) and polarized optical microscopy (POM). In addition, the mini-extruder is equipped with ports that allow sample collection, and the extrudate can be further processed into products to be tested later. Here, we present the concept and experimental set-up [1, 2]. As a typical application, we report on the characterization of the processing of a polymer blend and of the properties of extruded sheets. The morphological evolution of a PS/PMMA industrial blend along the extruder, the flow-induced structures developed and the corresponding rheological characteristics are presented, together with the mechanical and structural characteristics of produced sheets. The application of this experimental tool to other material systems will also be discussed.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Microinjection molding of polymer composites with carbon nanotubes (CNT) requires previous production of the nanocomposites, often by melt extrusion. Each processing step has a thermo-mechanical effect on the polymer melt, conveying different properties to the final product. In this work, polyamide 6 and its composites with pristine and functionalized CNT (f-CNT) were processed by a mini twin-screw extrusion, followed by microinjection molding. The morphology induced on the polymer by each process was analyzed by differential scanning calorimetry and wide angle X-ray diffraction. Calorimetric analysis showed a secondary crystallization for the microinjected materials, absent for the extruded materials. The characterization of microinjected polyamide 6 by X-ray diffraction revealed a large contribution of the c phase to the total crystallinity, mainly in the skin region, while the nanocomposites and extruded materials were characterized by a larger contribution of the a phase. Functionalization of CNT did not affect significantly the polymer morphology compared to composites with pristine CNT.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Understanding the mixing process of complex composite materials is fundamental in several industrial processes. For instance, the dispersion of fillers in polymer melt matrices is commonly employed to manufacture polymer composites, using a twin-screw extruder. The effectiveness of the filler dispersion depends not only on the complex flow patterns generated, but also on the polymer melt rheological behavior. Therefore, the availability of a numerical tool able to predict mixing, taking into account both fluid and particles phases would be very useful to increase the process insight, and thus provide useful guidelines for its optimization. In this work, a new Eulerian-Lagrangian numerical solver is developed OpenFOAM® computational library, and used to better understand the mechanisms determining the dispersion of fillers in polymer matrices. Particular attention will be given to the effect of the rheological model used to represent the fluid behavior, on the level of dispersion obtained. For the Eulerian phase the averaged volume fraction governing equations (conservation of mass and linear momentum) are used to describe the fluid behavior. In the case of the Lagrangian phase, Newton’s second law of motion is used to compute the particles trajectories and velocity. To study the effect of fluid behavior on the filler dispersion, several systems are modeled considering different fluid types (generalized Newtonian or viscoelastic) and particles volume fraction and size. The results obtained are used to correlate the fluid and particle characteristics on the effectiveness of mixing and morphology obtained.