971 resultados para neutralization assay


Relevância:

20.00% 20.00%

Publicador:

Resumo:

The observation that murine thymocytes increase their proliferation to interleukin 1 (IL-1) in the presence of phytohemagglutinin (PHA) when pre-incubated with interleukin 2 (IL-2) allowed the introduction of a modified assay for the measurement of IL-1 or the search of thymocyte-inducing proliferative activities in biological samples. Pre-incubation of thymocytes for 24 hr with 50 u/ml IL-2, followed by washings, elicited their maximal response to IL-1 in the usual lymphocyte activating factor (LAF) assay. This suggests that sequential events lead to thymocyte activation. The responsiveness is three to five fold greater than, and the total time of assay is the same as that of the LAF assay. Interestingly, pre-incubation with IL-2 renders thymocytes more sensitive than responsive to crude monocyte conditioned media. The use of the MTT colorimetric method for the assessment of thymocyte proliferation, and of the lectin jacalin as a co-mitogen are suggested as alternatives to be used in co-stimulatory assays.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Studies were done to evaluate comparatively the traditional HA assay and a more recently introduced lectin-neuraminidase (LN) methodologyin search of a simple and sensitive assay for virus detection during laboratorial diagnosis. The results proved the value of LN assay as a sensitive methodologyfor detection of virus particles, presenting results at least equal to those obtained by HA (hemagglutination) assay, with significant values of accumulated frequencies for LN/HA factors (ratios between LN and HA titers) higher than two. The accumulated values of frequencies for LN/HA factors as high as four were very significant, 72.7 (per cent) for influenzavirus and 60.7 (per cent) for Newcastle disease virus (NDV), moreover accumulated frequencies for LN/HA factors even as high as 32 were due to influenzavirus (45.4 per cent) and NDV (7.2 per cent) samples. After the storage period, most of those concentraded samples that even did not present HA titers could be detected through LN assay, demonstrating a lower threshold for virus detection.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

BACKGROUND: Enterovirus (EV) is the most frequent cause of aseptic meningitis (AM). Lack of microbiological documentation results in unnecessary antimicrobial therapy and hospitalization. OBJECTIVES: To assess the impact of rapid EV detection in cerebrospinal fluid (CSF) by a fully-automated PCR (GeneXpert EV assay, GXEA) on the management of AM. STUDY DESIGN: Observational study in adult patients with AM. Three groups were analyzed according to EV documentation in CSF: group A=no PCR or negative PCR (n=17), group B=positive real-time PCR (n=20), and group C=positive GXEA (n=22). Clinical, laboratory and health-care costs data were compared. RESULTS: Clinical characteristics were similar in the 3 groups. Median turn-around time of EV PCR decreased from 60h (IQR (interquartile range) 44-87) in group B to 5h (IQR 4-11) in group C (p<0.0001). Median duration of antibiotics was 1 (IQR 0-6), 1 (0-1.9), and 0.5 days (single dose) in groups A, B, and C, respectively (p<0.001). Median length of hospitalization was 4 days (2.5-7.5), 2 (1-3.7), and 0.5 (0.3-0.7), respectively (p<0.001). Median hospitalization costs were $5458 (2676-6274) in group A, $2796 (2062-5726) in group B, and $921 (765-1230) in group C (p<0.0001). CONCLUSIONS: Rapid EV detection in CSF by a fully-automated PCR improves management of AM by significantly reducing antibiotic use, hospitalization length and costs.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Since 1984, DNA tests based on the highly repeated subtelomeric sequences of Plasmodium falciparum (rep 20) have been frequently used in malaria diagnosis. Rep 20 is very specific for this parasite, and is made of 21 bp units, organized in repeated blocks with direct and inverted orientation. Based in this particular organization, we selected a unique consensus oligonucleotide (pf-21) to drive a PCR reaction coupled to hybridization to non-radioactive labeled probes. The pf-21 unique oligo PCR (pf-21-I) assay produced DNA amplification fingerprints when was applied on purified P. falciparum DNA samples (Brazil and Colombia), as well as in patient's blood samples from a large area of Venezuela. The performance of the Pf-21-I assay was compared against Giemsa stained thick blood smears from samples collected at a malaria endemic area of the Bolívar State, Venezuela, at the field station of Malariología in Tumeremo. Coupled to non-radioactive hybridization the pf-21-I performed better than the traditional microscopic method with a r=1.7:1. In the case of mixed infections the r value of P. falciparum detection increased to 2.5:1. The increased diagnostic sensitivity of the test produced with this homologous oligonucleotide could provide an alternative to the epidemiological diagnosis of P. falciparum being currently used in Venezuela endemic areas, where low parasitemia levels and asymptomatic malaria are frequent. In addition, the DNA fingerprint could be tested in molecular population studies

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Herpes simplex ocular infection is a major cause of corneal blindness. Local antiviral treatments exist but are associated with corneal toxicity, and resistance has become an issue. We evaluated the biodistribution and efficacy of a humanized anti-herpes simplex virus (anti-HSV) IgG FAb fragment (AC-8; 53 kDa) following repeated topical administration. AC-8 was found in the corneal epithelium, anterior stroma, subepithelial stromal cells, and retinal glial cells, with preferential entry through the ocular limbus. AC-8 was active against 13 different strains of HSV-1, with 50% and 90% mean effective concentrations (MEC(50) and MEC(90), respectively) ranging from 0.03 to 0.13 μg/ml, indicating broad-spectrum activity. The in vivo efficacy of AC-8 was evaluated in a mouse model of herpes-induced ocular disease. Treatment with low-dose AC-8 (1 mg/ml) slightly reduced the ocular disease scores. A greater reduction of the disease scores was observed in the 10-mg/ml AC-8-treated group, but not as much as with trifluridine (TFT). AC-8 treatment reduced viral titers but less than trifluridine. AC-8 did not display any toxicity to the cornea or other structures in the eye. In summary, topical instillation of an anti-HSV FAb can be used on both intact and ulcerated corneas. It is well tolerated and does not alter reepithelialization. Further studies to improve the antiviral effect are needed for AC-8 to be considered for therapeutic use.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Mouse mammary tumor virus (MMTV) infection establishes chronic germinal centers and a lifelong neutralizing Ab response. We show that removal of the draining lymph node after establishment of the germinal center reaction led to complete loss of neutralizing Abs despite comparable infection levels in peripheral lymphocytes. Importantly, in the absence of neutralization, only the exocrine organs mammary gland, salivary gland, pancreas, and skin showed strikingly increased infection, resulting in accelerated mammary tumor development. Induction of stronger neutralization did not influence chronic infection levels of peripheral lymphoid organs but strongly inhibited mammary gland infection and virus transmission to the next generation. Taken together, we provide evidence that a tight equilibrium in virus neutralization allows limited infection of exocrine organs and controls cancer development in susceptible mouse strains. These experiments show that a strong neutralizing Ab response induced after infection is not able to control lymphoid MMTV infection. Strong neutralization, however, is capable of blocking amplification of mammary gland infection, tumor development, and virus transmission to the next generation. The results also indicate a role of neutralization in natural resistance to MMTV infection.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Cytomegalovirus (CMV) infection has historically been a major complication among immunocompromised patients, such as solid-organ and stem-cell transplant recipients and patients with advanced HIV infection. While the introduction of antiretroviral therapy has almost eradicated CMV infection in HIV-infected patients, CMV disease remains a significant problem in transplant recipients once antiviral prophylaxis is discontinued. QuantiFERON(®)-CMV allows the assessment of cellular immunity against CMV by detecting the production of IFN-γ following in vitro stimulation with CMV antigens. Preliminary studies have shown a correlation between a lack of detectable cell-mediated immunity measured by the QuantiFERON-CMV assay and a higher incidence of CMV infection and disease in immunocompromised patients. Measurement of cell-mediated immunity against CMV appears to be a promising strategy to identify patients at highest risk for the development of CMV disease and, therefore, to individualize preventive strategies for CMV in transplant recipients.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The proteasome plays an essential role in the production of MHC class I-restricted antigenic peptides. Recent results have indicated that several peptidases, including tripeptidyl peptidase II and puromycin-sensitive aminopeptidase, could act downstream of the proteasome by trimming NH(2)-terminal extensions of antigenic peptide precursors liberated by the proteasome. In this study, we have developed a solid-phase peptidase assay that allowed us to efficiently purify and immobilize proteasome, tripeptidyl peptidase II, and puromycin-sensitive aminopeptidase. Whereas the first peptidase was active against small fluorogenic peptides, the latter two could also digest antigenic peptide precursors and could be used repeatedly with different precursors. Using three distinct antigenic peptide precursors, we found that tripeptidyl peptidase II never cleaved within the antigenic peptide sequence, suggesting that, aside from its proteolytic activities, it may also play a role in protecting antigenic peptides from complete hydrolysis in the cytosol. This method should be valuable for high throughput screenings of substrate specificity and potential inhibitors.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Dans cette étude, nous avons testé la performance diagnostique d'une nouvelle technique d'analyse multiplexée qui permet la détection d'anticorps de différentes spécificités dans la même réaction. En l'absence de gold standard, nous avons choisi de comparer la performance diagnostique de l'analyse avec deux méthodes de référance que sont l'IF et EIA, et avec un consensus déterminé selon une règle de majorité entre les trois méthodes.¦393 sérums analysés par IF, conservés par congélation, ont été décongelés pour être analysés par EIA et BBA. Pour chaque sérum, les anticorps recherchés ont été les anti-VCA (Viral Capsid Antigen) IgM, anti-VCA IgG et anti-EBNA (Epstein-Barr Nuclear Associated) IgG. Les échantillons ont été classés en cinq groupes selon les résultats de l'IF : séronégatifs, infections aiguës, infections anciennes et deux types d'indéterminés.¦Pour chaque méthode, le résultat numérique (index ou titre) des analyses est converti en termes de positif, négatif ou douteux. Pour le résultat de chaque type d'anticorps, un consensus est établi selon une règle de majorité entre les trois méthodes, permettant une interprétation du stade de l'infection. Puis l'interprétation de chacune des méthodes a été comparée au consensus. Nous avons également comparé les trois méthodes les unes aux autres concernant la détection des anticorps.¦Globalement, nous observons une bonne corrélation qualitative entre les trois approches pour détecter les anti-VCA IgG et IgM. Pour pour les anti-EBNA IgG, il y a une divergence notable entre l'IF et les deux autres méthodes, l'IF apparaissant moins sensible que les autres méthodes, résultant en un nombre accru d'interprétations indéterminées du stade de l'infection.¦L'origine de cette divergence ne peut être due à une perte d'anticorps liée au stockage de longue durée des échantillons. En effet, EIA et BBA restent plus sensibles que IF, dont l'analyse a été faite sur des sérums frais.¦Cette divergence ne semble pas non plus être due aux différents antigènes utilisés par les trois méthodes. EIA et BBA utilisent le même antigène recombinant EBNA-1, alors que l'IF utilise des "cellules lymphoïdes choisies pour leur production sélective d'antigènes EBNA". Ces cellules sont probablement des cellules infectées par EBV qui devraient exprimer plus d'antigènes de latence que seul EBNA-1. Cette différence devrait donc plutôt en principe résulter en une meilleure sensibilité de l'IF par rapport aux deux autres méthodes.¦Les anti-EBNA IgG peuvent disparaître chez les patients immunocompromis chez qui se produit une réactivation d'EBV. Nous avons donc recherché le status immunitaire des patients du groupe dont les sérums étaient négatifs pour anti-EBNA IgG en IF et positifs par les autres méthodes: seulement 28 des 70 patients étaient immunocompromis.¦Par conséquent, il est probable que dans la majorité de ces résultats discordants, les anticorps anti-EBNA IgG détectés par BBA et EIA sont de vrais positifs non décelés par l'IF.¦En conclusion, BBA est meilleur que la méthode de référance qu'est l'IF, et est égal à EIA en ce qui concerne la performance diagnostique. En outre, ces deux nouvelles méthodes offrent une économie de temps en raison de manipulations moindres, et ne requièrent aucune formation en microscopie à fluorescence. Elles sont également plus économes en échantillons que IF. BBA a l'avantage de n'avoir besoin que de deux analyses pour donner un diagnostique, alors que IF et EIA ont en besoin d'une par anticorps. Enfin, BBA dispose de contrôles internes permettant de reconnaître les liaisons non antigène-spécifiques des anticorps. Par contre, BBA nécessite l'achat d'un lecteur par cytométrie de flux assez coûteux.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A crude antigenic preparation of Babesia bigemina was used to develop an ELISA for the detection of IgM antibodies. Optimal dilutions of the antigen, using positive and negative reference sera, were determined by checkerboard titrations. Negative sera from cattle imported from tick-free areas, serum samples collected from infected B. bigemina cattle were used to validate the test. The specificity was 94% and sensitivity of the Elisa 87.5%. Sera from 385 cattle deriving from areas free from tick-borne diseases, which were submitted to a preimmunization process, were screened by this technique. The Elisa detected seroconversion on the 14th day post-inoculation in animals either infested with Boophilus microplus ticks (infected with B. bigemina), or inoculated with B. bigemina infected blood. Antibody titers decreased after day 33; however, all animals remained positive until the end of the experiment (124 days). The ELISA described may prove to be an appropriate serological test for the detection of IgM antibodies against B. bigemina.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

An enzyme-linked immunosorbent assay was standardized for the detection of cryptococcal antigen in serum and cerebrospinal fluid. The system was evaluated in clinical samples from patients infected by human immunodeficiency virus with and without previous cryptococcosis diagnosis. The evaluated system is highly sensitive and specific, and when it was compared with latex agglutination there were not significant differences. A standard curve with purified Cryptococcus neoformans antigen was settled down for the antigen quantification in positive samples.