264 resultados para multiplexed
Resumo:
Thesis (Ph.D.)--University of Washington, 2013
Resumo:
In this paper digital part of a self-calibrating quadrature-receiver is described, containing a digital calibration-engine. The blind source-separation-based calibration-engine eliminates the RF-impairments in real-time hence improving the receiver's performance without the need for test/pilot tones, trimming or use of power-hungry discrete components. Furthermore, an efficient time-multiplexed calibration-engine architecture is proposed and implemented on an FPGA utilising a reduced-range multiplier structure. The use of reduced-range multipliers results in substantial reduction of area as well as power consumption without a compromise in performance when compared with an efficiently designed general purpose multiplier. The performance of the calibration-engine does not depend on the modulation format or the constellation size of the received signal; hence it can be easily integrated into the digital signal processing paths of any receiver.
Resumo:
The RP protein (RPP) array approach immobilizes minute amounts of cell lysates or tissue protein extracts as distinct microspots on NC-coated slide. Subsequent detection with specific antibodies allows multiplexed quantification of proteins and their modifications at a scale that is beyond what traditional techniques can achieve. Cellular functions are the result of the coordinated action of signaling proteins assembled in macromolecular complexes. These signaling complexes are highly dynamic structures that change their composition with time and space to adapt to cell environment. Their comprehensive analysis requires until now relatively large amounts of cells (>5 x 10(7)) due to their low abundance and breakdown during isolation procedure. In this study, we combined small scale affinity capture of the T-cell receptor (TCR) and RPP arrays to follow TCR signaling complex assembly in human ex vivo isolated CD4 T-cells. Using this strategy, we report specific recruitment of signaling components to the TCR complex upon T-cell activation in as few as 0.5 million of cells. Second- to fourth-order TCR interacting proteins were accurately quantified, making this strategy specially well-suited to the analysis of membrane-associated signaling complexes in limited amounts of cells or tissues, e.g., ex vivo isolated cells or clinical specimens.
Resumo:
Point-of-care (POC) tests offer potentially substantial benefits for the management of infectious diseases, mainly by shortening the time to result and by making the test available at the bedside or at remote care centres. Commercial POC tests are already widely available for the diagnosis of bacterial and viral infections and for parasitic diseases, including malaria. Infectious diseases specialists and clinical microbiologists should be aware of the indications and limitations of each rapid test, so that they can use them appropriately and correctly interpret their results. The clinical applications and performance of the most relevant and commonly used POC tests are reviewed. Some of these tests exhibit insufficient sensitivity, and should therefore be coupled to confirmatory tests when the results are negative (e.g. Streptococcus pyogenes rapid antigen detection test), whereas the results of others need to be confirmed when positive (e.g. malaria). New molecular-based tests exhibit better sensitivity and specificity than former immunochromatographic assays (e.g. Streptococcus agalactiae detection). In the coming years, further evolution of POC tests may lead to new diagnostic approaches, such as panel testing, targeting not just a single pathogen, but all possible agents suspected in a specific clinical setting. To reach this goal, the development of serology-based and/or molecular-based microarrays/multiplexed tests will be needed. The availability of modern technology and new microfluidic devices will provide clinical microbiologists with the opportunity to be back at the bedside, proposing a large variety of POC tests that will allow quicker diagnosis and improved patient care.
Resumo:
Les réseaux de nanotrous sont des structures plasmoniques ayant un énorme potentiel en tant que transducteurs pour la conception de biocapteurs. De telles structures sont prometteuses pour l’élaboration de biocapteurs capable d’effectuer du criblage à haut débit. L’intérêt de travailler avec des réseaux de nanotrous est dû à la simplicité d’excitation des polaritons de plasmons de surface en transmission directe, à la sensibilité et à la facilité de fabrication de ces senseurs. L’architecture de tels réseaux métalliques permet la conception de nanostructures ayant de multiples propriétés plasmoniques. L’intensité, la signature spectrale et la sensibilité du signal plasmonique sont grandement affectées par l’aspect physique du réseau de nanotrous. L’optimisation du signal plasmonique nécessite ainsi un ajustement du diamètre des trous, de la périodicité et de la composition métallique du réseau. L'agencement de l'ensemble de ces paramètres permet d'identifier une structure optimale possédant une périodicité de 1000 nm, un diamètre des nanotrous de 600-650 nm et un film métallique ayant une épaisseur de 125 nm d'or. Ce type de transducteur a une sensibilité en solution de 500-600 nm/RIU pour des bandes plasmoniques situées entre 600-700 nm. L'intérêt de travailler avec cette structure est la possibilité d'exciter les plasmons de polaritons de surface (SPPs) selon deux modes d'excitation : en transmission exaltée (EOT) ou en réflexion totale interne par résonance des plasmons de surface (SPR). Une comparaison entre les propriétés plasmoniques des senseurs selon les modes d'excitation permet de déterminer expérimentalement que le couplage de la lumière avec les ondes de SPP de Bloch (BW-SPPs) en transmission directe résulte en un champ électromagnétique davantage propagatif que localisé. D'un point de vue analytique, la biodétection de l'IgG en SPR est 6 fois plus sensible par rapport au mode EOT pour une même structure. Une étude du signal plasmonique associé au BW-SPP pour un certain mode de diffraction démontre que la distance de pénétration de ces structures en EOT est d'environ 140 nm. La limite de détection de l'IgG humain pour un réseau de nanotrous de 1000 nm de périodicité est d'environ 50 nM en EOT. Ce mémoire démontre la viabilité des réseaux de nanotrous pour effectuer de la biodétection par criblage à haut débit lors de prochaines recherches. L'investigation de l'effet de l'angle d'excitation en transmission exaltée par rapport au signal plasmonique associé au mode (1,0) d'un réseau de nanotrous de 820 nm d'or démontre que la sensibilité en solution n'est pas proportionnelle à la sensibilité en surface du senseur. En fait, une optimisation de l'angle d'incidence pour le mode (1,0) de diffraction des BW-SPP permet d'amplifier la sensibilité en surface du senseur jusqu'à 3-fois pour un angle de 13,3°. Ce mémoire démontre ainsi la nécessité d'optimiser l'angle d'excitation et les propriétés physiques du senseur afin de développer un transducteur de grande sensibilité basé sur l'excitation en transmission de réseaux de nanotrous.
Resumo:
La présente thèse avait pour mandat d’examiner la question suivante : quels sont les indices visuels utilisés pour catégoriser le sexe d’un visage et comment sont-ils traités par le cerveau humain? La plupart des études examinant l’importance de certaines régions faciales pour la catégorisation du sexe des visages présentaient des limites quant à leur validité externe. L’article 1 visait à investiguer l’utilisation des indices achromatiques et chromatiques (sur l’axe xy) dans un contexte de plus grande validité externe. Pour ce faire, nous avons utilisé la technique Bubbles afin d’échantillonner l’espace xy de visages en couleurs n’ayant subi aucune transformation. Afin d’éviter les problèmes liés à la grande répétition des mêmes visages, nous avons utilisé un grand nombre de visages (c.-à-d. 300 visages caucasiens d’hommes et de femmes) et chaque visage n’a été présenté qu’une seule fois à chacun des 30 participants. Les résultats indiquent que la région des yeux et des sourcils—probablement dans le canal blanc-noir—est l’indice le plus important pour discriminer correctement le genre des visages; et que la région de la bouche—probablement dans le canal rouge-vert—est l’indice le plus important pour discriminer rapidement et correctement le genre des visages. Plusieurs études suggèrent qu’un indice facial que nous n’avons pas étudié dans l’article 1—les distances interattributs—est crucial à la catégorisation du sexe. L’étude de Taschereau et al. (2010) présente toutefois des données allant à l’encontre de cette hypothèse : les performances d’identification des visages étaient beaucoup plus faibles lorsque seules les distances interattributs réalistes étaient disponibles que lorsque toutes les autres informations faciales à l’exception des distances interattributs réalistes étaient disponibles. Quoi qu’il en soit, il est possible que la faible performance observée dans la condition où seules les distances interattributs étaient disponibles soit explicable non par une incapacité d’utiliser ces indices efficacement, mais plutôt par le peu d’information contenue dans ces indices. L’article 2 avait donc comme objectif principal d’évaluer l’efficacité—une mesure de performance qui compense pour la faiblesse de l’information disponible—des distances interattributs réalistes pour la catégorisation du sexe des visages chez 60 participants. Afin de maximiser la validité externe, les distances interattributs manipulées respectaient la distribution et la matrice de covariance observées dans un large échantillon de visages (N=515). Les résultats indiquent que les efficacités associées aux visages ne possédant que de l’information au niveau des distances interattributs sont un ordre de magnitude plus faibles que celles associées aux visages possédant toute l’information que possèdent normalement les visages sauf les distances interattributs et donnent le coup de grâce à l’hypothèse selon laquelle les distances interattributs seraient cuciale à la discrimination du sexe des visages. L’article 3 avait pour objectif principal de tester l’hypothèse formulée à la fin de l’article 1 suivant laquelle l’information chromatique dans la région de la bouche serait extraite très rapidement par le système visuel lors de la discrimination du sexe. Cent douze participants ont chacun complété 900 essais d’une tâche de discrimination du genre pendant laquelle l’information achromatique et chromatique des visages était échantillonnée spatiotemporellement avec la technique Bubbles. Les résultats d’une analyse présentée en Discussion seulement confirme l’utilisation rapide de l’information chromatique dans la région de la bouche. De plus, l’utilisation d’un échantillonnage spatiotemporel nous a permis de faire des analyses temps-fréquences desquelles a découlé une découverte intéressante quant aux mécanismes d’encodage des informations spatiales dans le temps. Il semblerait que l’information achromatique et chromatique à l’intérieur d’une même région faciale est échantillonnée à la même fréquence par le cerveau alors que les différentes parties du visage sont échantillonnées à des fréquences différentes (entre 6 et 10 Hz). Ce code fréquentiel est compatible avec certaines évidences électrophysiologiques récentes qui suggèrent que les parties de visages sont « multiplexées » par la fréquence d’oscillations transitoires synchronisées dans le cerveau.
Resumo:
Coded OFDM is a transmission technique that is used in many practical communication systems. In a coded OFDM system, source data are coded, interleaved and multiplexed for transmission over many frequency sub-channels. In a conventional coded OFDM system, the transmission power of each subcarrier is the same regardless of the channel condition. However, some subcarrier can suffer deep fading with multi-paths and the power allocated to the faded subcarrier is likely to be wasted. In this paper, we compute the FER and BER bounds of a coded OFDM system given as convex functions for a given channel coder, inter-leaver and channel response. The power optimization is shown to be a convex optimization problem that can be solved numerically with great efficiency. With the proposed power optimization scheme, near-optimum power allocation for a given coded OFDM system and channel response to minimize FER or BER under a constant transmission power constraint is obtained
Resumo:
The towed array electronics is essentially a multichannel real time data acquisition system. The major challenges involved in it are the simultaneous acquisition of data from multiple channels, telemetry of the data over tow cable (several kilometres in some systems) and synchronization with the onboard receiver for accurate reconstruction. A serial protocol is best suited to transmit the data to onboard electronics since number of wires inside the tow cable is limited. The best transmission medium for data over large distances is the optical fibre. In this a two step approach towards the realization of a reliable telemetry scheme for the sensor data using standard protocols is described. The two schemes are discussed in this paper. The first scheme is for conversion of parallel, time-multiplexed multi-sensor data to Ethernet. Existing towed arrays can be upgraded to ethernet using this scheme. Here the last lap of the transmission is by Ethernet over Fibre. For the next generation of towed arrays it is required to digitize and convert the data to ethernet close to the sensor. This is the second scheme. At the heart of this design is the Analog-to-Ethernet node. In addition to a more reliable interface, this helps in easier fault detection and firmware updates in the field for the towed arrays. The design challenges and considerations for incorporating a network of embedded devices within the array are highlighted
Resumo:
The progress in microsystem technology or nano technology places extended requirements to the fabrication processes. The trend is moving towards structuring within the nanometer scale on the one hand, and towards fabrication of structures with high aspect ratio (ratio of vertical vs. lateral dimensions) and large depths in the 100 µm scale on the other hand. Current procedures for the microstructuring of silicon are wet chemical etching and dry or plasma etching. A modern plasma etching technique for the structuring of silicon is the so-called "gas chopping" etching technique (also called "time-multiplexed etching"). In this etching technique, passivation cycles, which prevent lateral underetching of sidewalls, and etching cycles, which etch preferably in the vertical direction because of the sidewall passivation, are constantly alternated during the complete etching process. To do this, a CHF3/CH4 plasma, which generates CF monomeres is employed during the passivation cycle, and a SF6/Ar, which generates fluorine radicals and ions plasma is employed during the etching cycle. Depending on the requirements on the etched profile, the durations of the individual passivation and etching cycles are in the range of a few seconds up to several minutes. The profiles achieved with this etching process crucially depend on the flow of reactants, i.e. CF monomeres during the passivation cycle, and ions and fluorine radicals during the etching cycle, to the bottom of the profile, especially for profiles with high aspect ratio. With regard to the predictability of the etching processes, knowledge of the fundamental effects taking place during a gas chopping etching process, and their impact onto the resulting profile is required. For this purpose in the context of this work, a model for the description of the profile evolution of such etching processes is proposed, which considers the reactions (etching or deposition) at the sample surface on a phenomenological basis. Furthermore, the reactant transport inside the etching trench is modelled, based on angular distribution functions and on absorption probabilities at the sidewalls and bottom of the trench. A comparison of the simulated profiles with corresponding experimental profiles reveals that the proposed model reproduces the experimental profiles, if the angular distribution functions and absorption probabilities employed in the model is in agreement with data found in the literature. Therefor the model developed in the context of this work is an adequate description of the effects taking place during a gas chopping plasma etching process.
Resumo:
High-speed semiconductor lasers are an integral part in the implemen- tation of high-bit-rate optical communications systems. They are com- pact, rugged, reliable, long-lived, and relatively inexpensive sources of coherent light. Due to the very low attenuation window that exists in the silica based optical fiber at 1.55 μm and the zero dispersion point at 1.3 μm, they have become the mainstay of optical fiber com- munication systems. For the fabrication of lasers with gratings such as, distributed bragg reflector or distributed feedback lasers, etching is the most critical step. Etching defines the lateral dimmensions of the structure which determines the performance of optoelectronic devices. In this thesis studies and experiments were carried out about the exist- ing etching processes for InP and a novel dry etching process was de- veloped. The newly developed process was based on Cl2/CH4/H2/Ar chemistry and resulted in very smooth surfaces and vertical side walls. With this process the grating definition was significantly improved as compared to other technological developments in the respective field. A surface defined grating definition approach is used in this thesis work which does not require any re-growth steps and makes the whole fabrication process simpler and cost effective. Moreover, this grating fabrication process is fully compatible with nano-imprint lithography and can be used for high throughput low-cost manufacturing. With usual etching techniques reported before it is not possible to etch very deep because of aspect ratio dependent etching phenomenon where with increasing etch depth the etch rate slows down resulting in non-vertical side walls and footing effects. Although with our de- veloped process quite vertical side walls were achieved but footing was still a problem. To overcome the challenges related to grating defini- tion and deep etching, a completely new three step gas chopping dry etching process was developed. This was the very first time that a time multiplexed etching process for an InP based material system was demonstrated. The developed gas chopping process showed extra ordinary results including high mask selectivity of 15, moderate etch- ing rate, very vertical side walls and a record high aspect ratio of 41. Both the developed etching processes are completely compatible with nano imprint lithography and can be used for low-cost high-throughput fabrication. A large number of broad area laser, ridge waveguide laser, distributed feedback laser, distributed bragg reflector laser and coupled cavity in- jection grating lasers were fabricated using the developed one step etch- ing process. Very extensive characterization was done to optimize all the important design and fabrication parameters. The devices devel- oped have shown excellent performance with a very high side mode suppression ratio of more than 52 dB, an output power of 17 mW per facet, high efficiency of 0.15 W/A, stable operation over temperature and injected currents and a threshold current as low as 30 mA for almost 1 mm long device. A record high modulation bandwidth of 15 GHz with electron-photon resonance and open eye diagrams for 10 Gbps data transmission were also shown.
Resumo:
While protein microarray technology has been successful in demonstrating its usefulness for large scale high-throughput proteome profiling, performance of antibody/antigen microarrays has been only moderately productive. Immobilization of either the capture antibodies or the protein samples on solid supports has severe drawbacks. Denaturation of the immobilized proteins as well as inconsistent orientation of antibodies/ligands on the arrays can lead to erroneous results. This has prompted a number of studies to address these challenges by immobilizing proteins on biocompatible surfaces, which has met with limited success. Our strategy relates to a multiplexed, sensitive and high-throughput method for the screening quantification of intracellular signalling proteins from a complex mixture of proteins. Each signalling protein to be monitored has its capture moiety linked to a specific oligo âtag’. The array involves the oligonucleotide hybridization-directed localization and identification of different signalling proteins simultaneously, in a rapid and easy manner. Antibodies have been used as the capture moieties for specific identification of each signaling protein. The method involves covalently partnering each antibody/protein molecule with a unique DNA or DNA derivatives oligonucleotide tag that directs the antibody to a unique site on the microarray due to specific hybridization with a complementary tag-probe on the array. Particular surface modifications and optimal conditions allowed high signal to noise ratio which is essential to the success of this approach.
Resumo:
In this paper, we consider the ATM networks in which the virtual path concept is implemented. The question of how to multiplex two or more diverse traffic classes while providing different quality of service requirements is a very complicated open problem. Two distinct options are available: integration and segregation. In an integration approach all the traffic from different connections are multiplexed onto one VP. This implies that the most restrictive QOS requirements must be applied to all services. Therefore, link utilization will be decreased because unnecessarily stringent QOS is provided to all connections. With the segregation approach the problem can be much simplified if different types of traffic are separated by assigning a VP with dedicated resources (buffers and links). Therefore, resources may not be efficiently utilized because no sharing of bandwidth can take place across the VP. The probability that the bandwidth required by the accepted connections exceeds the capacity of the link is evaluated with the probability of congestion (PC). Since the PC can be expressed as the CLP, we shall simply carry out bandwidth allocation using the PC. We first focus on the influence of some parameters (CLP, bit rate and burstiness) on the capacity required by a VP supporting a single traffic class using the new convolution approach. Numerical results are presented both to compare the required capacity and to observe which conditions under each approach are preferred
Resumo:
An in silico screen of 41 of the 81 coding regions of the Nicotiana plastid genome generated a shortlist of 12 candidates as DNA barcoding loci for land plants. These loci were evaluated for amplification and sequence variation against a reference set of 98 land plant taxa. The deployment of multiple primers and a modified multiplexed tandem polymerase chain reaction yielded 85–94% amplification across taxa, and mean sequence differences between sister taxa of 6.1 from 156 bases of accD to 22 from 493 bases of matK. We conclude that loci should be combined for effective diagnosis, and recommend further investigation of the following six loci: matK, rpoB, rpoC1, ndhJ, ycf5 and accD.
Resumo:
C-reactive protein (CRP) is an acute phase protein whose levels are increased in many disorders. There exists, in particular, a great deal of interest in the correlation between blood serum levels and the severity of risk for cardiovascular disease. A sensitive, label-free, non-amplified and reusable electrochemical impedimetric biosensor for the detection of CRP in blood serum was developed herein based on controlled and coverage optimised antibody immobilization on standard polycrystalline gold electrodes. Charge transfer resistance changes were highly target specific, linear with log. CRP. concentration across a 0.5-50. nM range and associated with a limit of detection of 176. pM. Significantly, the detection limits are better than those of current CRP clinical methods and the assays are potentially cheap, relatively automated, reusable, multiplexed and highly portable. The generated interfaces were capable not only of comfortably quantifying CRP across a clinically relevant range of concentrations but also of doing this in whole blood serum with interfaces that were, subsequently, reusable. The importance of optimising receptor layer resistance in maximising assay sensitivity is also detailed. © 2012.
Resumo:
Routing and wavelength assignment (RWA) is an important problem that arises in wavelength division multiplexed (WDM) optical networks. Previous studies have solved many variations of this problem under the assumption of perfect conditions regarding the power of a signal. In this paper, we investigate this problem while allowing for degradation of routed signals by components such as taps, multiplexers, and fiber links. We assume that optical amplifiers are preplaced. We investigate the problem of routing the maximum number of connections while maintaining proper power levels. The problem is formulated as a mixed-integer nonlinear program and two-phase hybrid solution approaches employing two different heuristics are developed