967 resultados para mini-slump


Relevância:

20.00% 20.00%

Publicador:

Resumo:

The retromolar triangle is a triangular area located in the mandible, posteriorly to the last molar. This region, due its thickness and bone density, is widely used for the installation of devices that provide an anchorage system for the movement of the lower molars. The aim of this research is to provide morphometric data of the mucosa thickness of the retromolar triangle. Twenty-five patients of portuguese nationality, with indication for extraction of the impacted lower third molar (right and/or left), were studied. In the region of the retromolar triangle were demarcated 3 points corresponding to the vertices of a triangle whose the base was torned for the distal face of the lower third molar and the lenght of the sides corresponded to vestibulolingual dimension of the same tooth, then was demarcated a fourth point corresponding to the geometric center of the triangle. Then, using a finger spreader with silicone stop were measured the mucosal tickness at each point. The data obtained were tabulated and analyzed. The lowest average value found was 5.5mm on the right side and the highest average value found was 7.13mm on the left side. Considering the mean values obtained at the points of the retromolar triangle mucosa measured in this study, we conclude that the retromolar triangle shows thick mucosa, so the mini-implants indicated for this region should have a long transmucosal neck.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Pós-graduação em Agronomia (Horticultura) - FCA

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Orthodontic mini-implants are used in clinical practice to provide efficient and aesthetically-pleasing anchorage. AIM: To evaluate the hardness Vickers hardness and chemical composition of mini-implant titanium alloys from five commercial brands. METHODS: Thirty self-drilling mini-implants, six each from the following commercial brands, were used: Neodent NEO, Morelli MOR, Sin SIN, Conexão CON, and Rocky Mountain RMO. The hardness and chemical composition of the titanium alloys were performed by the Vickers hardness test and energy dispersive X-ray spectroscopy, respectively. RESULTS: Vickers hardness was significantly higher in SIN implants than in NEO, MOR, and CON implants. Similarly, VH was significantly higher in RMO implants than in MOR and NEO ones. In addition, VH was higher in CON implants than in NEO ones. There were no significant differences in the proportions of titanium and aluminum in the mini-implant alloy of the five commercial brands. Conversely, the proportion of vanadium differed significantly between CON and MOR/NEO implants. CONCLUSIONS: Mini-implants of different brands presented distinct properties of hardness and composition of the alloy.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Production of mini vegetables in organic system is a good alternative to improve profit, but there are no researches about the optimum plant density for these cultivars in Brazilian conditions. Two experiments were conducted to evaluate the production of mini lettuce cultivars in different plant densities. Experiment 1 was conducted from January 1th (sowing) to February 10th (harvesting), 2012. The experimental design was completely randomized blocks, with six treatments in factorial scheme, 3 mini lettuce cultivars (Tudela, Renoir and Sartre) x 2 spacing between plants (16 and 20 cm), with eight replications and plots (2.04 m(2)) with six rows, spaced 15 cm. Experiment 2 was conducted from June 6th (sowing) to July 18th (harvesting), 2012. The cultivars Sartre and Renoir were evaluated under four plant densities (444,444; 333,333; 266,667 and 200,000 plants ha(-1), corresponding to spacing of 15x15, 15x20, 25x15 and 25x20 cm, respectively). Eight treatments were defined by a factorial scheme 2 (cultivars) x 4 (plant densities) and arranged in a completely randomized block design, with nine replications and plots with 2.04 m2. The evaluated characteristics in both experiments were total and marketable fresh weight per plant, plant dry weight, plant diameter and height, marketable yield and discard percentage. In first experiment, during the summer, cultivar Sartre showed the highest marketable fresh weight (72 g plant(-1)). Heaviest plants (91.6 g plant(-1)) were obtained with the higher plant spacing, but the highest yield (2.51 kg m(-2)) was obtained with the smaller spacing. In winter, plants with higher total (190 g plant(-1)) and marketable (146 g planta(-1)) fresh weight were obtained with cultivar Sartre, and the same was observed in low plant density. However, the higher plant density, the higher the yield.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This study investigated the biomechanical behavior of screwed partial fixed prosthesis supported by implants with different diameters (2.5 mm; 3.3 mm and 3.75 mm) by using a photoelastic analysis. Six photoelastic models were fabricated in PL-2 resin as single crowns or splinted 3-unit piece. Models were positioned in a circular polariscope and 100-N axial and oblique (45 degrees) loads were applied in the occlusal surface of the crowns by using a universal testing machine (EMIC). The stresses were photographically recorded and qualitatively analyzed using a software (Adobe Photoshop). Under axial loading, the number of fringes was inversely proportional to the diameter of the implants in the single crown models. In the splinted 3-unit piece, the 3.75-mm implant promoted lower number of fringes regardless of loading area application. Under oblique loading, a slight increase of fringes number was observed for all groups. The standard implant diameter promoted better stress distribution than the narrow and mini diameter implants. Additionally, the splinted crowns showed a more uniform stress distribution.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In the last decade mini-screws have gained popularity in orthodontics field and a correct placement of mini-screws is a critical point to the success of the skeletal anchorage. A careful clinical and radiographic diagnostic before insertion mini-screw is an essential requirement to achieve the central point of the radicular septum. The correct application of these pre-surgical procedures should avoid possible iatrogenic damages in periodontal ligament, dental roots, nasomaxillary cavities, or even important vascular tissues. As of today, periapical radiographs is a regular pre surgical procedure during mini-screw insertion technique. Nevertheless, accurate execution of the radiographic parallax technique can offer to us useful and precise radiographic images, to decide the right local insertion of mini-screws in to the septum bone. The purpose of this paper is to describe the ¬application of new positioning circular guides in conjunction with a ¬parallax radiographic protocol before placement of orthodontic mini-screws.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The introduction of more efficient diagnostic methods, new techniques in surgery and transplantation, antibiotics and chemotherapeutics more potent and novel materials for prostheses, catheters and probes significantly increased the life expectancy and quality of life of critically ill patients, on the other hand, hospital-acquired infections emerged as important iatrogenic complications. Invasive infections are a growing problem in public health hospitals in Brazil and worldwide. Among the various etiological agents found in the hospital environment, the genus Candida has been the third most frequently isolated pathogen. In general, invasive fungal infections are associated with high morbidity and mortality, difficulties in diagnosis, antimicrobial resistance, length of hospital stay and increased hospital costs. This mini review of the literature describes about epidemiology of hospital infection of Candida species, as well as its virulence factors and drugs resistance

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The use of images as a mean of human knowledge transmission dates from the earliest records of visual communication with the cave paintings. Throughout history, the communicating function remained and was extended for a variety of approaches, including illustration, which plays an important role by transmitting a content to be communicated on a creative and unique way. The advertising area relies largely on the communicative power of illustration, using it as a visual aid on different ways and medias. The advertising pieces aimed at the automotive sector – especially those developed by BMW for the Mini Cooper model – broadly employs illustrations to spread the word about the product and its attributes, seeking to communicate it using an original way. With a qualitative approach to the case study, this article analyzes the illustrations produced by the South African design studio Am I Collective as part of a video prepared by South African advertising agency Blackriver FC as a celebration campaign for the fifty years of vehicle Mini Cooper, celebrated on 2009, and it aims to identify the illustrations visuals and compositions used in the construction of the covered temporal panorama.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Good morning. It's my very great pleasure to welcome you to this third annual mini-symposium in Redox Biology.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The objective of this work is to evaluate the efficiency of the mini-cuttings technique in the vegetative propagation of half-sibs of angico-vermelho (Anadenanthera macrocarpa(Benth) Brenan) regarding to the productive capacity and survival of mini-stumps, rooting of the apical and intermediate mini-cuttings treated with different doses of IBA (0, 2000, 4000 and 6000 mg L-1) as well as to determine the speed of rooting in the greenhouse. The mini-stumps were obtained from seedlings of the six progenies of Anadenanthera macrocarpa half-sibs. The mini-stumps presented productivity from 1,2 to 3,7 mini-cuttings/mini-stump/collection and survival of 84% to 98% after six harvests. The apical mini-cuttings were higher than the intermediate, more prone to root, but the IBA had no significant effect on the rooting of the progenies. The results of the rooting speed showed variation among the progenies.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Mini-implant insertion requires accurate surgical technique. This study shows an insertion technique using only tooth crown references; its scientific basis is evaluated radiographically. The sample consisted of 213 inter-radicular septa, evaluated in 53 bitewing radiographs. The proximal contour of adjacent tooth crowns was used to define septum width. The midpoint of the septum width was linked to the interdental contact point to determine septum midline. The distances from septum midline to "mesial and distal teeth were measured to evaluate the septum midline centralization degree in two different septum heights. The difference between mesial and distal distances represented the septum midline deviation degree. The mesial and distal distances were compared by t-tests, and the septum midline deviation was correlated with septum height using Pearson's correlation test. The mesial and distal distances were not statistically different in the midpoint of the septum height, but they were different at the apical septum height. There was a moderate correlation (r = 0.45) between septum midline deviation and septum height. The tooth crown references evaluated on interproximal radiographs determine a high centralization degree of the septum midline on which the insertion site could be defined. The greater centralization degree was observed at the coronal septum area.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

It is possible to determine the optimum time for permanence of vegetative propagules (mini-cuttings) inside a greenhouse for rooting, and this value can be used to optimize the structure of the nursery. The aim of this study was to determine the dynamics of adventitious rooting in mini-cuttings of three clones of Eucalyptus benthamii x Eucalyptus dunnii. Sprouts of H12, H19 and H20 clones were collected from mini-stumps that were planted in gutters containing sand and grown in a semi-hydroponic system. The basal region of the mini-cuttings was immersed in 2,000 mg L-1 indole-3-butyric acid (IBA) solution for 10 seconds. The rooting percentage of the mini-cuttings, the total length of the root system and the rooting rate per mini-cutting were also evaluated at 0 (time of planting), 7, 14, 21, 28, 35, 42, 49 and 56 days. We used logistic and exponential regression to mathematically model the speed of rhizogenesis. The rooting percentage was best represented as a logistic model, and the total length of the root system was best represented as an exponential model. The clones had different speeds of adventitious rooting. The optimum time for permanence of the mini-cuttings inside the greenhouse for rooting was between 35 and 42 days, and varied depending on the genetic material.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Objective: To verify if mini-implant mobility is affected by the presence of periodontopathogens, frequently associated with peri-implantitis. Materials and Methods: The surfaces of 31 mini-implants used for skeletal anchorage in orthodontic patients were evaluated. Polymerase chain reaction was used for identification of the presence of DNA from three different periodontopathogens (P. intermedia [Pi], A. actinomycetemcomitans [Aa], and P. gingivalis [Pg]) in 16 mini-implants without mobility (control group) and 15 mini-implants with mobility (experimental group). Results: The results showed that Pi was present in 100% of the samples, from both groups: Aa was found in 31.3% of the control group and in 13.3% of the experimental group. Pg was detected in 37.4% of the control group and in 33.3% of the experimental group. The Fisher exact test and the odds ratio (OR) values for Aa and Pg (OR = 0.34; 95% confidence interval [CI]: 0.05-2.10 and OR = 0.61; 95% Cl: 0.13-2.79, respectively) showed no significant association (P > .05) between the periodontopathogens studied and the mobility of the mini-implants. Conclusions: It can be concluded that the presence of Aa, Pi, and Pg around mini-implants is not associated with mobility. (Angle Orthod. 2012;82:591-595.)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Seven sides of cadaver heads were used to compare the surgical exposures provided by the mini-modified orbitozygomatic (MOz) and supra-orbital (SO) approaches. The Optotrak 3020 computerized tracking system (Northern Digital, Waterloo, ON, Canada) was utilized to evaluate the area of anatomical exposure defined by six points: (1) ipsilateral sphenoid ridge; (2) most distal point of the ipsilateral middle cerebral artery (MCA); (3) most distal point of the ipsilateral posterior cerebral artery (PCA); (4) most distal point of the contralateral PCA; (5) most distal point of the contralateral MCA; and (6) contralateral sphenoid ridge. Additionally, angles of approach for the ipsilateral MCA bifurcation, ipsilateral ICA bifurcation, basilar artery tip, contralateral MCA and ICA bifurcation and anterior communicating artery (AcomA) were evaluated, first for SO and then for MOz. An image guidance system was used to evaluate the limits of surgical exposure. No differences in the area of surgical exposure were noted (p > 0.05). Vertical angles were significantly wider for the ipsilateral and contralateral ICA bifurcation, AcomA, contralateral MCA and basilar tip (p < 0.05) for MOz. No differences in horizontal angles were observed between the approaches for the six targets (p > 0.05). There were no differences in the limits of exposure. MOz affords no additional surgical working space. However, our results demonstrate systematically that vertical exposure is improved. The MOz should be performed while planning an approach to these regions and a wider exposure in the vertical axis is needed. (C) 2012 Elsevier Ltd. All rights reserved.