926 resultados para metallic tube
Resumo:
This paper reports the effects of fluid therapy in goats through nasogastric route with an electrolyte solution composed by concentrations of sodium, potassium and chloride similar to goat plasma (140mmol/L of Na+, 4.5mmol/L of K+, 110mmol/L of Cl-). Four Alpine Chamoisee goats, two of them with evident leakage of the rumen cannulas, were used in a crossover experimental design of two periods and two groups. In one group the two goats were submitted to a treatment protocol to induce dehydration before the fluid therapy, whereas the other group was not. Fluid therapy consisted supplying 10mL/kg/h of the electrolyte solution during 8 hours. No signs of discomfort or stress were observed. The dehydration model employed caused a mild dehydration indicated by decrease in feces humidity, body weight and abdominal circumference, and increase in plasma total solids concentration. During fluid therapy globular volume and plasma total solids decreased, whereas % body weight and abdominal circumference increased. No signs of hyperhydration were observed and serum electrolytes (Na+, Cl-, K+) presented no significant alterations in both groups. Fluid therapy proposed in this study was efficient to treat dehydration, even for rumen cannulated animals with evident leakage, and can be administrated safely with no electrolyte imbalance.
Resumo:
The objective of the present work is the experimental determination of pressure drop coefficients (loss coefficients) for elliptic and circular sections in one, two and three-row arrangements of plate fin and tube heat exchangers. The experiments permitted to correlate the dimensionless loss coefficient with the flow Reynolds number in the rectangular channel formed by the plate fins. The experimental technique consisted of the measurement of the longitudinal pressure distribution along the flow channel, for several values of air mass flow rate. The total number of data runs, each one characterized by the flow Reynolds number, was 216. The present geometry is used in compact heat exchangers for air conditioning systems, heaters, radiators, and others. Also, it is verified the influence of the utilization of elliptic tubes, instead of circular ones, in the pressure drop. The measurements were performed for Reynolds numbers ranging from 200 to 1900.
Resumo:
This study has a technical and applied character. A PVC structured wall pipe can be produced by spirally winding a ribbed sheet having a male-female lock, chemically welded by an adhesive. These pipes are "flexible" and are used mainly in underground installations, to convey fluids in free duct regime. Initial studies have indicated that the buckling resistance of the ribs from the sheet coiling to the tube manufacturing is the critical design parameter. This study presents the theoretical analytical development in order to obtain the critical buckling moment of these sheets. This analysis uses concepts initially developed to calculate buckling resistance in monosymmetrical profiles that are very used in the metallic structure industry. Since the material used was PVC, that has different mechanical properties than steel and aluminum, it was necessary to consider the differences in the analytical treatment. It is important to emphasize that the results obtained are product of the co-operative work of engineers from industry and university.
Resumo:
Työssä kehitetään standardin EN 12952 mukaisille vesiputkikattiloiden paineenalaisille osille lujuuslaskentaohjelma. Lisäksi perehdytään putkisto-osien mitoituksen lujuusopilliseen pohjaan ja tarkastellaan vastaako standardin mitoitus sitä. Standardin EN 13480 mukaisille metallisille teollisuusputkistoille on kohdeyrityksellä käytössään mitoitusohjelma. Näin ollen työssä vertaillaan standardin EN 12952 ja EN 13480 mukaisia putkisto-osien mitoituksia. Vertailun perusteella selvitetään mitkä putkistokomponentit voidaan mitoittaa olemassa olevalla ohjelmalla. Joidenkin putkisto-osien mitoitus on standardeissa yhtenevä. Suunnittelujännitys määritetään kuitenkin eri tavalla kyseisissä standardeissa. Tämän takia kaikki yrityksen tarvitsemat putkistokomponentit ovat kirjattu kehitettyyn laskentaohjelmaan. Koska putkistokomponenttien mitoitus on yhtenevä monelta osin kyseisissä standardeissa, vertaillaan ohjelmien antamia tuloksia toisiinsa. Näin voidaan todeta kehitetty laskentaohjelma toimivaksi.
Resumo:
The emergence of multidrug-resistant strains of Mycobacterium tuberculosis has increased the need for rapid drug susceptibility tests, which are needed for adequate patient treatment. The objective of the present study was to evaluate the mycobacteria growth indicator tube (MGIT) system to detect multidrug-resistant M. tuberculosis strains. The MGIT system was compared with two standard methods (proportion and resistance ratio methods). One hundred clinical M. tuberculosis isolates [25 susceptible to isoniazid (INH) and rifampicin (RIF), 20 resistant to INH, 30 resistant to INH-RIF, and 25 resistant to INH-RIF and other drugs] obtained in the State of São Paulo were tested for INH and RIF susceptibility. Full agreement among the tests was found for all sensitive and all INH-resistant strains. For RIF-resistant strains results among the tests agreed for 53 (96.4%) of 55 isolates. Results were obtained within 6 days (range, 5 to 8 days), 28 days and 12 days when using MGIT, the proportion method and the resistance ratio methods, respectively. The MGIT system presented an overall agreement of 96% when compared with two standard methods. These data show that the MGIT system is rapid, sensitive and efficient for the early detection of multidrug-resistant M. tuberculosis.
Resumo:
Important advances have been made in understanding the genetic processes that control skeletal muscle formation. Studies conducted on quails detected a delay in the myogenic program of animals selected for high growth rates. These studies have led to the hypothesis that a delay in myogenesis would allow somitic cells to proliferate longer and consequently increase the number of embryonic myoblasts. To test this hypothesis, recently segmented somites and part of the unsegmented paraxial mesoderm were separated from the neural tube/notochord complex in HH12 chicken embryos. In situ hybridization and competitive RT-PCR revealed that MyoD transcripts, which are responsible for myoblast determination, were absent in somites separated from neural tube/notochord (1.06 and 0.06 10-3 attomol MyoD/1 attomol ß-actin for control and separated somites, respectively; P<0.01). However, reapproximation of these structures allowed MyoD to be expressed in somites. Cellular proliferation was analyzed by immunohistochemical detection of incorporated BrdU, a thymidine analogue. A smaller but not significant (P = 0.27) number of proliferating cells was observed in somites that had been separated from neural tube/notochord (27 and 18 for control and separated somites, respectively). These results confirm the influence of the axial structures on MyoD activation but do not support the hypothesis that in the absence of MyoD transcripts the cellular proliferation would be maintained for a longer period of time.
Resumo:
Non-metallic implants made of bioresorbable or biostable synthetic polymers are attractive options in many surgical procedures, ranging from bioresorbable suture anchors of arthroscopic surgery to reconstructive skull implants made of biostable fiber-reinforced composites. Among other benefits, non-metallic implants produce less interference in imaging. Bioresorbable polymer implants may be true multifunctional, serving as osteoconductive scaffolds and as matrices for simultaneous delivery of bone enhancement agents. As a major advantage for loading conditions, mechanical properties of biostable fiber-reinforced composites can be matched with those of the bone. Unsolved problems of these biomaterials are related to the risk of staphylococcal biofilm infections and to the low osteoconductivity of contemporary bioresorbable composite implants. This thesis was focused on the research and development of a multifunctional implant model with enhanced osteoconductivity and low susceptibility to infection. In addition, the experimental models for assessment, diagnostics and prophylaxis of biomaterial-related infections were established. The first experiment (Study I) established an in vitro method for simultaneous evaluation of calcium phosphate and biofilm formation on bisphenol-Aglycidyldimethacrylate and triethylenglycoldimethacrylate (BisGMA-TEGDMA) thermosets with different content of bioactive glass 45S5. The second experiment (Study II) showed no significant difference in osteointegration of nanostructured and microsized polylactide-co-glycolide/β-tricalcium phosphate (PLGA /β-TCP) composites in a minipig model. The third experiment (Study III) demonstrated that positron emission tomography (PET) imaging with the novel 68Ga labelled 1,4,7,10-tetraazacyclododecane-1,4,7,10-tetraacetic acid (DOTA) CD33 related sialic-acid immunoglobulin like lectins (Siglec-9) tracer was able to detect inflammatory response to S. epidermidis and S. aureus peri-implant infections in an intraosseous polytetrafluoroethylene catheter model. In the fourth experiment (Study IV), BisGMATEGDMA thermosets coated with lactose-modified chitosan (Chitlac) and silver nanoparticles exhibited antibacterial activity against S. aureus and P. aeruginosa strains in an in vitro biofilm model and showed in vivo biocompatibility in a minipig model. In the last experiment (Study V), a selective androgen modulator (SARM) released from a poly(lactide)-co-ε-caprolactone (PLCL) polymer matrix failed to produce a dose-dependent enhancement of peri-implant osteogenesis in a bone marrow ablation model.
Resumo:
Radiotherapy is one of the main approaches to cure prostate cancer, and its success depends on the accuracy of dose planning. A complicating factor is the presence of a metallic prosthesis in the femur and pelvis, which is becoming more common in elderly populations. The goal of this work was to perform dose measurements to check the accuracy of radiotherapy treatment planning under these complicated conditions. To accomplish this, a scale phantom of an adult pelvic region was used with alanine dosimeters inserted in the prostate region. This phantom was irradiated according to the planned treatment under the following three conditions: with two metallic prostheses in the region of the femur head, with only one prosthesis, and without any prostheses. The combined relative standard uncertainty of dose measurement by electron spin resonance (ESR)/alanine was 5.05%, whereas the combined relative standard uncertainty of the applied dose was 3.35%, resulting in a combined relative standard uncertainty of the whole process of 6.06%. The ESR dosimetry indicated that there was no difference (P>0.05, ANOVA) in dosage between the planned dose and treatments. The results are in the range of the planned dose, within the combined relative uncertainty, demonstrating that the treatment-planning system compensates for the effects caused by the presence of femur and hip metal prostheses.
Resumo:
Alfa Laval Aalborg Oy designs and manufactures waste heat recovery systems utilizing extended surfaces. The waste heat recovery boiler considered in this thesis is a water-tube boiler where exhaust gas is used as the convective heat transfer medium and water or steam flowing inside the tubes is subject to cross-flow. This thesis aims to contribute to the design of waste heat recovery boiler unit by developing a numerical model of the H-type finned tube bundle currently used by Alfa Laval Aalborg Oy to evaluate the gas-side heat transfer performance. The main objective is to identify weaknesses and potential areas of development in the current H-type finned tube design. In addition, numerical simulations for a total of 15 cases with varying geometric parameters are conducted to investigate the heat transfer and pressure drop performance dependent on H-type fin geometry. The investigated geometric parameters include fin width and height, fin spacing, and fin thickness. Comparison between single and double tube type configuration is also conducted. Based on the simulation results, the local heat transfer and flow behaviour of the H-type finned tube is presented including boundary layer development between the fins, the formation of recirculation zone behind the tubes, and the local variations of flow velocity and temperature within the tube bundle and on the fin surface. Moreover, an evaluation of the effects of various fin parameters on heat transfer and pressure drop performance of H-type finned tube bundle has been provided. It was concluded that from the studied parameters fin spacing and fin width had the most significant effect on tube bundle performance and the effect of fin thickness was the least important. Furthermore, the results suggested that the heat transfer performance would increase due to enhanced turbulence if the current double tube configuration is replaced with single tube configuration, but further investigation and experimental measurements are required in order to validate the results.
Resumo:
A large amount of fly ash is produced in power plants and a big fraction of it ends up as waste to landfills. Disposal of fly ash to landfills is expensive for power plants due to for example waste taxation. However fly ash can utilized in different applications. Possibility of utilizing fly ash can be increased by granulation which also removes the dustiness problems of ash. This Thesis deals with the prerequisites for commercialization of a new granulation technique, tube granulation. Tube granulation technique utilizes water, calcium oxide in fly ash plus carbon dioxide and heat from flue gas. This Thesis determines the necessary auxiliary equipment for tube granulation, approaches for process dimensioning and implementation of the granulation process into a continuous power plant process. In addition, the economic benefits of tube granulation are examined from the user’s perspective. A continuous tube granulation process requires the following auxiliary systems to function: ash system, water feed system and flue gas system. Implementation of tube granulation system into a power plant process depends on the specific power plant but a general principle is that fly ash should be obtained to the granulator as fresh as possible and flue gas should be taken from the pressure side of a flue gas fan. Dimensioning of the process can be examined for example in terms of degree of filling and residence time in the granulator or in terms of granule drying. Determining the optimal dimensioning parameters requires pilot tests with the granulator.
Resumo:
Référence bibliographique : Rol, 60179
Resumo:
Comprend : Bouche, pharynx, oesophage, estomac, intestin, anus
Resumo:
Thesis (M. Sc.) - Brock University, 1978.