865 resultados para message compliance
Resumo:
Large Dynamic Message Signs (DMSs) have been increasingly used on freeways, expressways and major arterials to better manage the traffic flow by providing accurate and timely information to drivers. Overhead truss structures are typically employed to support those DMSs allowing them to provide wider display to more lanes. In recent years, there is increasing evidence that the truss structures supporting these large and heavy signs are subjected to much more complex loadings than are typically accounted for in the codified design procedures. Consequently, some of these structures have required frequent inspections, retrofitting, and even premature replacement. Two manufacturing processes are primarily utilized on truss structures - welding and bolting. Recently, cracks at welding toes were reported for the structures employed in some states. Extremely large loads (e.g., due to high winds) could cause brittle fractures, and cyclic vibration (e.g., due to diurnal variation in temperature or due to oscillations in the wind force induced by vortex shedding behind the DMS) may lead to fatigue damage, as these are two major failures for the metallic material. Wind and strain resulting from temperature changes are the main loads that affect the structures during their lifetime. The American Association of State Highway and Transportation Officials (AASHTO) Specification defines the limit loads in dead load, wind load, ice load, and fatigue design for natural wind gust and truck-induced gust. The objectives of this study are to investigate wind and thermal effects in the bridge type overhead DMS truss structures and improve the current design specifications (e.g., for thermal design). In order to accomplish the objective, it is necessary to study structural behavior and detailed strain-stress of the truss structures caused by wind load on the DMS cabinet and thermal load on the truss supporting the DMS cabinet. The study is divided into two parts. The Computational Fluid Dynamics (CFD) component and part of the structural analysis component of the study were conducted at the University of Iowa while the field study and related structural analysis computations were conducted at the Iowa State University. The CFD simulations were used to determine the air-induced forces (wind loads) on the DMS cabinets and the finite element analysis was used to determine the response of the supporting trusses to these pressure forces. The field observation portion consisted of short-term monitoring of several DMS Cabinet/Trusses and long-term monitoring of one DMS Cabinet/Truss. The short-term monitoring was a single (or two) day event in which several message sign panel/trusses were tested. The long-term monitoring field study extended over several months. Analysis of the data focused on trying to identify important behaviors under both ambient and truck induced winds and the effect of daily temperature changes. Results of the CFD investigation, field experiments and structural analysis of the wind induced forces on the DMS cabinets and their effect on the supporting trusses showed that the passage of trucks cannot be responsible for the problems observed to develop at trusses supporting DMS cabinets. Rather the data pointed toward the important effect of the thermal load induced by cyclic (diurnal) variations of the temperature. Thermal influence is not discussed in the specification, either in limit load or fatigue design. Although the frequency of the thermal load is low, results showed that when temperature range is large the restress range would be significant to the structure, especially near welding areas where stress concentrations may occur. Moreover stress amplitude and range are the primary parameters for brittle fracture and fatigue life estimation. Long-term field monitoring of one of the overhead truss structures in Iowa was used as the research baseline to estimate the effects of diurnal temperature changes to fatigue damage. The evaluation of the collected data is an important approach for understanding the structural behavior and for the advancement of future code provisions. Finite element modeling was developed to estimate the strain and stress magnitudes, which were compared with the field monitoring data. Fatigue life of the truss structures was also estimated based on AASHTO specifications and the numerical modeling. The main conclusion of the study is that thermal induced fatigue damage of the truss structures supporting DMS cabinets is likely a significant contributing cause for the cracks observed to develop at such structures. Other probable causes for fatigue damage not investigated in this study are the cyclic oscillations of the total wind load associated with the vortex shedding behind the DMS cabinet at high wind conditions and fabrication tolerances and induced stresses due to fitting of tube to tube connections.
Resumo:
This report contains information about Iowa's public drinking water program for the calendar year 2014. Included in the report are descriptions of Iowa's systems, monitoring and reporting requirements of the systems, and violations incurred during the year. This report meets the federal Safe Drinking Water Act's requirement of an annual report on violations of national primary drinking water regulations by public water supply systems in Iowa.
Resumo:
Cytomegalovirus (CMV) remains a major cause of morbidity in solid organ transplant patients. In order to reduce CMV morbidity, we designed a program of routine virological monitoring that included throat and urine CMV shell vial culture, along with peripheral blood leukocyte (PBL) shell vial quantitative culture for 12 weeks post-transplantation, as well as 8 weeks after treatment for acute rejection. The program also included preemptive ganciclovir treatment for those patients with the highest risk of developing CMV disease, i.e., with either high-level viremia (>10 infectious units [IU]/106 PBL) or low-level viremia (<10 IU/106 PBL) and either D+/R- CMV serostatus or treatment for graft rejection. During 1995-96, 90 solid organ transplant recipients (39 kidneys, 28 livers, and 23 hearts) were followed up. A total of 60 CMV infection episodes occurred in 45 patients. Seventeen episodes were symptomatic. Of 26 episodes managed according to the program, only 4 presented with CMV disease and none died. No patient treated preemptively for asymptomatic infection developed disease. In contrast, among 21 episodes managed in non-compliance with the program (i.e., the monitoring was not performed or preemptive treatment was not initiated despite a high risk of developing CMV disease), 12 episodes turned into symptomatic infection (P=0.0048 compared to patients treated preemptively), and 2 deaths possibly related to CMV were recorded. This difference could not be explained by an increased proportion of D+/R- patients or an increased incidence of rejection among patients with episodes treated in non-compliance with the program. Our data identify compliance with guidelines as an important factor in effectively reducing CMV morbidity through preemptive treatment, and suggest that the complexity of the preemptive approach may represent an important obstacle to the successful prevention of CMV morbidity by this approach in the regular healthcare setting.
Resumo:
School dental screening of all high schools in Iowa that have participated. A state summary.
Resumo:
School dental screening of all high schools in Iowa that have participated. A state summary.
Resumo:
OBJECTIVE: To determine whether infusion line compliance contributes to irregular drug delivery during vertical displacement of syringe pumps. DESIGN: Five different commercially available infusion lines were studied at infusion rates of 0.5, 1.0, and 1.5 ml/h. Zero drug delivery time was measured after acute line loop formation (70 cm) using an electronic balance. Compliance of each infusion line was calculated using a pressure transducer and measurement of the occlusion release bolus at 300 mmHg occlusion pressure. Finally, the influence of infusion line compliance on drug delivery during acute lowering of the syringe pump was studied using low- and high-compliance infusion lines. RESULTS: Acute line loop formation resulted in zero drug delivery time from 5.1 +/- 1.5 to 44.0 +/- 6.8 s at flow rates of 0.5 ml/h. Increased flow rates significantly reduced loop-induced flow variability. A close correlation was found between zero drug delivery time and calculated infusion line compliance at 0.5 ml/h (linear regression R2 = 0.79). Lowering of the syringe pump 50 cm prolonged zero drug delivery time from 295.8 +/- 20.7 s with the low-compliance tube to 463.3 +/- 24.0 s with the high-compliance infusion line. CONCLUSIONS: Infusion line compliance contributes to irregular drug delivery associated with vertical displacement of syringe pumps. Siphoning of the infusion line during patient care should be avoided, and flow rates of 1 ml/h or higher are recommended. Low-compliance infusion lines are indicated whenever highly short-acting vasoactive drugs at low delivery rates are administered.
Resumo:
School dental screening of all high schools in Iowa that have participated. A state summary.
Resumo:
School dental screening of all high schools in Iowa that have participated. A state summary.
Resumo:
School dental screening of all high schools in Iowa that have participated. A state summary.
Resumo:
School dental screening of all high schools in Iowa that have participated. A state summary.
Resumo:
School dental screening of all high schools in Iowa that have participated. A state summary.
Resumo:
The enormous success of Linux in the consumer electronics industry has unfortunately led to a dramatic increase in license violations in devices. In this talk we will shortly look at the backgrounds of these violations, tooling to help uncover violations and what is needed to prevent future violations from happening.
Resumo:
Hand hygiene compliance of patients receiving hemodialysis treatment is a contemporary discussion topic among health care professionals in the Nephrology Clinic of Helsinki University City Hospital. The purpose of the Final Thesis is to review patient hand hygiene in terms of risks its lack entails and based on the evidence based findings to design an end product as a poster. The poster can be utilised in the Nephrology Clinic's nursing environment to educate and motivate patients to pay specifid attention to the importance of hand hygiene. The method used was a systematic literature review. The most important evidence based findings were extracted from the chosen thirteen scientific articles. All articles were searched from the Cumulative Index to Nursing and Allied Health Literature electronic database. The gathered information was then used to build the content of a patient education tool that for this project was defined as a Poster. The findings in this study showed that transmission of bloodborne infections, like Hepatitis B or C virus can occur through a vascular access and that the consequences of this can be very fatal. Additionally, environmental surfaces such as furniture, door knobs and dialysis machine control knobs were all possible infection sources for the patient receiving hemodialysis treatment. Adherence to good hand hygiene behaviour lowered the risk for infections. The end product of this study is a poster that is targeted to patients undergoing hemodialysis treatment. Using a health promotion agenda in the Poster, it is hoped that patients will pay more attention to the importance of hand hygiene and that they will be more motivated to use aseptic methods such as alcohol based hand rubs in the hemodialysis setting.