920 resultados para measurement techniques of Aerosoles
Resumo:
This paper presents a review of the time-domain polarization measurement techniques for the condition assessment of aged transformer insulation. The polarization process is first described with appropriate dielectric response theories and then commonly used polarization methods are described with special emphasis on the most widely used return voltage(rv) measurement. Most recent emphasis has been directed to techniques of determining moisture content of insulation indirectly by measuring rv parameters. The major difficulty still lies with the accurate interpretation of return voltage results. This paper investigates different thoughts regarding the interpretation of rv results for different moisture and ageing conditions. Other time domain polarization measurement techniques and their results are also presented in this paper.
Resumo:
Dissertation presented to obtain the degree of Doctor of Philosophy in Electrical Engineering, speciality on Perceptional Systems, by the Universidade Nova de Lisboa, Faculty of Sciences and Technology
Resumo:
Dissertação apresentada para obtenção do Grau de Doutor em Ciências da Educação, pela Faculdade de Ciências e Tecnologia da Universidade Nova de Lisboa
Resumo:
Analytical, numerical and experimental models have been developed over time to try to characterize and understand the metal cutting process by chip removal. A true knowledge of the cutting process by chip removal is required by the increasing production, by the quality requirements of the product and by the reduced production time, in the industries in which it is employed. In this thesis an experimental setup is developed to evaluate the forces and the temperature distribution in the tool according to the orthogonal cutting model conditions, in order to evaluate its performance and its possible adoption in future works. The experimental setup is developed in a CNC lathe and uses an orthogonal cutting configuration, in which thin discs fixed onto a mandrel are cut by the cutting insert. In this experimental setup, the forces are measured by a piezoelectric dynamometer while temperatures are measured by thermocouples placed juxtaposed to the side face of the cutting insert. Three different solutions are implemented and evaluated for the thermocouples attachment in the cutting insert: thermocouples embedded in thermal paste, thermocouples embedded in copper plate and thermocouples brazed in the cutting insert. From the tests performed in the experimental setup it is concluded that the adopted forces measurement technique shows a good performance. Regarding to the adopted temperatures measurement techniques, only the thermocouples brazed in the cutting insert solution shows a good performance for temperature measurement. The remaining solutions show contact problems between the thermocouple and the side face of the cutting insert, especially when the vibration phenomenon intensifies during the cut. It is concluded that the experimental setup does not present a sufficiently robust and reliable performance, and that it can only be used in future work after making improvements in the assembly of the thermocouples.
Resumo:
OBJECTIVE: Local heating increases skin blood flow SkBF (thermal hyperemia). In a previous study, we reported that a first local thermal stimulus could attenuate the hyperemic response to a second one applied later on the same skin spot, a phenomenon that we termed desensitization. However, other studies found no evidence for desensitization in similar conditions. The aim of the present work was to test whether it was related to differences in instrumentation. METHODS: Twenty-eight healthy young males were studied. Two pairs of heating chambers, one custom-made (our study) and one commercial (other groups), were affixed to forearm skin. SkBF was measured with single-point laser-Doppler flowmetry (LDF) (780nm) in one pair, and laser-Doppler imaging (LDI) (633nm) in the other. A temperature step from 34 to 41°C, was applied for 30minutes and repeated after two hours. RESULTS: During the second thermal challenge, the plateau SkBF was lower than during the first thermal and was observed with each of the four combinations of SkBF measurement techniques and heating equipment (p<0.05 for all conditions, range -9% to -16% of the initial value). CONCLUSION: Desensitization of thermal hyperemia is not specific to peculiar operating conditions.
Resumo:
Knowledge of the spatial distribution of hydraulic conductivity (K) within an aquifer is critical for reliable predictions of solute transport and the development of effective groundwater management and/or remediation strategies. While core analyses and hydraulic logging can provide highly detailed information, such information is inherently localized around boreholes that tend to be sparsely distributed throughout the aquifer volume. Conversely, larger-scale hydraulic experiments like pumping and tracer tests provide relatively low-resolution estimates of K in the investigated subsurface region. As a result, traditional hydrogeological measurement techniques contain a gap in terms of spatial resolution and coverage, and they are often alone inadequate for characterizing heterogeneous aquifers. Geophysical methods have the potential to bridge this gap. The recent increased interest in the application of geophysical methods to hydrogeological problems is clearly evidenced by the formation and rapid growth of the domain of hydrogeophysics over the past decade (e.g., Rubin and Hubbard, 2005).
Resumo:
Hypoglycaemia is a major cause of neonatal morbidity and may induce long-term developmental sequelae. Clinical signs of hypoglycaemia in neonatal infants are unspecific or even absent, and therefore, precise and accurate methods for the assessment of glycaemia are needed. Glycaemia measurement in newborns has some particularities like a very low limit of normal glucose concentration compared to adults and a large range of normal haematocrit values. Many bedside point-of-care testing (POCT) systems are available, but literature about their accuracy in newborn infants is scarce and not very convincing. In this retrospective study, we identified over a 1-year study period 1,324 paired glycaemia results, one obtained at bedside with one of three different POCT systems (Elite? XL, Ascensia? Contour? and ABL 735) and the other in the central laboratory of the hospital with the hexokinase reference method. All three POCT systems tended to overestimate glycaemia values, and none of them fulfilled the ISO 15197 accuracy criteria. The Elite XL appeared to be more appropriate than Contour to detect hypoglycaemia, however with a low specificity. Contour additionally showed an important inaccuracy with increasing haematocrit. The bench analyzer ABL 735 was the most accurate of the three tested POCT systems. Both of the tested handheld glucometers have important drawbacks in their use as screening tools for hypoglycaemia in newborn infants. ABL 735 could be a valuable alternative, but the blood volume needed is more than 15 times higher than for handheld glucometers. Before daily use in the newborn population, careful clinical evaluation of each new POCT system for glucose measurement is of utmost importance.
Resumo:
The integration of geophysical data into the subsurface characterization problem has been shown in many cases to significantly improve hydrological knowledge by providing information at spatial scales and locations that is unattainable using conventional hydrological measurement techniques. The investigation of exactly how much benefit can be brought by geophysical data in terms of its effect on hydrological predictions, however, has received considerably less attention in the literature. Here, we examine the potential hydrological benefits brought by a recently introduced simulated annealing (SA) conditional stochastic simulation method designed for the assimilation of diverse hydrogeophysical data sets. We consider the specific case of integrating crosshole ground-penetrating radar (GPR) and borehole porosity log data to characterize the porosity distribution in saturated heterogeneous aquifers. In many cases, porosity is linked to hydraulic conductivity and thus to flow and transport behavior. To perform our evaluation, we first generate a number of synthetic porosity fields exhibiting varying degrees of spatial continuity and structural complexity. Next, we simulate the collection of crosshole GPR data between several boreholes in these fields, and the collection of porosity log data at the borehole locations. The inverted GPR data, together with the porosity logs, are then used to reconstruct the porosity field using the SA-based method, along with a number of other more elementary approaches. Assuming that the grid-cell-scale relationship between porosity and hydraulic conductivity is unique and known, the porosity realizations are then used in groundwater flow and contaminant transport simulations to assess the benefits and limitations of the different approaches.
Resumo:
BACKGROUND Several studies in recent years have evaluated Health Related Quality of Life (HRQoL) of patients with primary hyperparathyroidism (PHPT). No disease specific questionnaires are available to assess the impact of the disease. The aim of this research is to describe the development of a new disease specific Quality of Life (QoL) questionnaire for use specifically with PHPT patients. METHODS A conceptual model was developed describing the impact of the disease and its symptoms on QoL domains. A literature review was conducted to identify the most relevant domains. A focus group with experts was used to validate the domains; 24 patients were also interviewed to complement the information from the patient's perspective. A content analysis of the interviews was performed to identify items related with the impact of the disease, leading to PHPQoL-V.1 which was presented to a sample of 67 patients. Reliability was assessed by Cronbach's coefficient alpha and item-total score correlations. Validity was assessed by a factor analysis performed to determine the number of domains. Rasch analysis was carried out in order to refine the questionnaire items. RESULTS 259 items were extracted from the interviews that were subsequently reduced to 34 items. Cronbach's coefficient alpha was 0.92. The factor analysis extracted two domains (physical and emotional). After Rasch analysis the questionnaire PHPQoL-V.2 kept 16 items (9 physical and 7 emotional). The questionnaire was developed in a Spanish population and the final version was translated to English through translation and back-translation. CONCLUSION The first disease specific HRQoL questionnaire for PHPT patients (PHPQoL-16) has been developed. Validation studies designed to assess measurement properties of this tool are currently underway.
Resumo:
Background: The COSMIN checklist (COnsensus-based Standards for the selection of health status Measurement INstruments) was developed in an international Delphi study to evaluate the methodological quality of studies on measurement properties of health-related patient reported outcomes (HR-PROs). In this paper, we explain our choices for the design requirements and preferred statistical methods for which no evidence is available in the literature or on which the Delphi panel members had substantial discussion. Methods: The issues described in this paper are a reflection of the Delphi process in which 43 panel members participated. Results: The topics discussed are internal consistency (relevance for reflective and formative models, and distinction with unidimensionality), content validity (judging relevance and comprehensiveness), hypotheses testing as an aspect of construct validity (specificity of hypotheses), criterion validity (relevance for PROs), and responsiveness (concept and relation to validity, and (in) appropriate measures).Conclusions: We expect that this paper will contribute to a better understanding of the rationale behind the items, thereby enhancing the acceptance and use of the COSMIN checklist.
Resumo:
Background: The COSMIN checklist is a tool for evaluating the methodological quality of studies on measurement properties of health-related patient-reported outcomes. The aim of this study is to determine the inter-rater agreement and reliability of each item score of the COSMIN checklist (n = 114). Methods: 75 articles evaluating measurement properties were randomly selected from the bibliographic database compiled by the Patient-Reported Outcome Measurement Group, Oxford, UK. Raters were asked to assess the methodological quality of three articles, using the COSMIN checklist. In a one-way design, percentage agreement and intraclass kappa coefficients or quadratic-weighted kappa coefficients were calculated for each item. Results: 88 raters participated. Of the 75 selected articles, 26 articles were rated by four to six participants, and 49 by two or three participants. Overall, percentage agreement was appropriate (68% was above 80% agreement), and the kappa coefficients for the COSMIN items were low (61% was below 0.40, 6% was above 0.75). Reasons for low inter-rater agreement were need for subjective judgement, and accustom to different standards, terminology and definitions.Conclusions: Results indicated that raters often choose the same response option, but that it is difficult on item level to distinguish between articles. When using the COSMIN checklist in a systematic review, we recommend getting some training and experience, completing it by two independent raters, and reaching consensus on one final rating. Instructions for using the checklist are improved.
Resumo:
Background: Choosing an adequate measurement instrument depends on the proposed use of the instrument, the concept to be measured, the measurement properties (e.g. internal consistency, reproducibility, content and construct validity, responsiveness, and interpretability), the requirements, the burden for subjects, and costs of the available instruments. As far as measurement properties are concerned, there are no sufficiently specific standards for the evaluation of measurement properties of instruments to measure health status, and also no explicit criteria for what constitutes good measurement properties. In this paper we describe the protocol for the COSMIN study, the objective of which is to develop a checklist that contains COnsensus-based Standards for the selection of health Measurement INstruments, including explicit criteria for satisfying these standards. We will focus on evaluative health related patient-reported outcomes (HR-PROs), i.e. patient-reported health measurement instruments used in a longitudinal design as an outcome measure, excluding health care related PROs, such as satisfaction with care or adherence. The COSMIN standards will be made available in the form of an easily applicable checklist.Method: An international Delphi study will be performed to reach consensus on which and how measurement properties should be assessed, and on criteria for good measurement properties. Two sources of input will be used for the Delphi study: (1) a systematic review of properties, standards and criteria of measurement properties found in systematic reviews of measurement instruments, and (2) an additional literature search of methodological articles presenting a comprehensive checklist of standards and criteria. The Delphi study will consist of four (written) Delphi rounds, with approximately 30 expert panel members with different backgrounds in clinical medicine, biostatistics, psychology, and epidemiology. The final checklist will subsequently be field-tested by assessing the inter-rater reproducibility of the checklist.Discussion: Since the study will mainly be anonymous, problems that are commonly encountered in face-to-face group meetings, such as the dominance of certain persons in the communication process, will be avoided. By performing a Delphi study and involving many experts, the likelihood that the checklist will have sufficient credibility to be accepted and implemented will increase.
Resumo:
Highway noise is one of the most pressing of the surface characteristics issues facing the concrete paving industry. This is particularly true in urban areas, where not only is there a higher population density near major thoroughfares, but also a greater volume of commuter traffic (Sandberg and Ejsmont 2002; van Keulen 2004). To help address this issue, the National Concrete Pavement Technology Center (CP Tech Center) at Iowa State University (ISU), Federal Highway Administration (FHWA), American Concrete Pavement Association (ACPA), and other organizations have partnered to conduct a multi-part, seven-year Concrete Pavement Surface Characteristics Project. This document contains the results of Part 1, Task 2, of the ISU-FHWA project, addressing the noise issue by evaluating conventional and innovative concrete pavement noise reduction methods. The first objective of this task was to determine what if any concrete surface textures currently constructed in the United States or Europe were considered quiet, had long-term friction characteristics, could be consistently built, and were cost effective. Any specifications of such concrete textures would be included in this report. The second objective was to determine whether any promising new concrete pavement surfaces to control tire-pavement noise and friction were in the development stage and, if so, what further research was necessary. The final objective was to identify measurement techniques used in the evaluation.
Resumo:
Objective: To evaluate the safety of the performance of the traditional and protected collection techniques of tracheal aspirate and to identify qualitative and quantitative agreement of the results of microbiological cultures between the techniques. Method: Clinical, prospective, comparative, single-blind research. The sample was composed of 54 patients of >18 years of age, undergoing invasive mechanical ventilation for a period of ≥48 hours and with suspected Ventilator Associated Pneumonia. The two techniques were implemented in the same patient, one immediately after the other, with an order of random execution, according to randomization by specialized software. Results: No significant events occurred oxygen desaturation, hemodynamic instability or tracheobronchial hemorrhage (p<0.05) and, although there were differences in some strains, there was qualitative and quantitative agreement between the techniques (p<0.001). Conclusion: Utilization of the protected technique provided no advantage over the traditional and execution of both techniques was safe for the patient.
Resumo:
Abstract Accurate characterization of the spatial distribution of hydrological properties in heterogeneous aquifers at a range of scales is a key prerequisite for reliable modeling of subsurface contaminant transport, and is essential for designing effective and cost-efficient groundwater management and remediation strategies. To this end, high-resolution geophysical methods have shown significant potential to bridge a critical gap in subsurface resolution and coverage between traditional hydrological measurement techniques such as borehole log/core analyses and tracer or pumping tests. An important and still largely unresolved issue, however, is how to best quantitatively integrate geophysical data into a characterization study in order to estimate the spatial distribution of one or more pertinent hydrological parameters, thus improving hydrological predictions. Recognizing the importance of this issue, the aim of the research presented in this thesis was to first develop a strategy for the assimilation of several types of hydrogeophysical data having varying degrees of resolution, subsurface coverage, and sensitivity to the hydrologic parameter of interest. In this regard a novel simulated annealing (SA)-based conditional simulation approach was developed and then tested in its ability to generate realizations of porosity given crosshole ground-penetrating radar (GPR) and neutron porosity log data. This was done successfully for both synthetic and field data sets. A subsequent issue that needed to be addressed involved assessing the potential benefits and implications of the resulting porosity realizations in terms of groundwater flow and contaminant transport. This was investigated synthetically assuming first that the relationship between porosity and hydraulic conductivity was well-defined. Then, the relationship was itself investigated in the context of a calibration procedure using hypothetical tracer test data. Essentially, the relationship best predicting the observed tracer test measurements was determined given the geophysically derived porosity structure. Both of these investigations showed that the SA-based approach, in general, allows much more reliable hydrological predictions than other more elementary techniques considered. Further, the developed calibration procedure was seen to be very effective, even at the scale of tomographic resolution, for predictions of transport. This also held true at locations within the aquifer where only geophysical data were available. This is significant because the acquisition of hydrological tracer test measurements is clearly more complicated and expensive than the acquisition of geophysical measurements. Although the above methodologies were tested using porosity logs and GPR data, the findings are expected to remain valid for a large number of pertinent combinations of geophysical and borehole log data of comparable resolution and sensitivity to the hydrological target parameter. Moreover, the obtained results allow us to have confidence for future developments in integration methodologies for geophysical and hydrological data to improve the 3-D estimation of hydrological properties.