951 resultados para measurement data
Resumo:
We propose a new method for fitting proportional hazards models with error-prone covariates. Regression coefficients are estimated by solving an estimating equation that is the average of the partial likelihood scores based on imputed true covariates. For the purpose of imputation, a linear spline model is assumed on the baseline hazard. We discuss consistency and asymptotic normality of the resulting estimators, and propose a stochastic approximation scheme to obtain the estimates. The algorithm is easy to implement, and reduces to the ordinary Cox partial likelihood approach when the measurement error has a degenerative distribution. Simulations indicate high efficiency and robustness. We consider the special case where error-prone replicates are available on the unobserved true covariates. As expected, increasing the number of replicate for the unobserved covariates increases efficiency and reduces bias. We illustrate the practical utility of the proposed method with an Eastern Cooperative Oncology Group clinical trial where a genetic marker, c-myc expression level, is subject to measurement error.
Resumo:
Molybdenum isotopes are increasingly widely applied in Earth Sciences. They are primarily used to investigate the oxygenation of Earth's ocean and atmosphere. However, more and more fields of application are being developed, such as magmatic and hydrothermal processes, planetary sciences or the tracking of environmental pollution. Here, we present a proposal for a unifying presentation of Mo isotope ratios in the studies of mass-dependent isotope fractionation. We suggest that the δ98/95Mo of the NIST SRM 3134 be defined as +0.25‰. The rationale is that the vast majority of published data are presented relative to reference materials that are similar, but not identical, and that are all slightly lighter than NIST SRM 3134. Our proposed data presentation allows a direct first-order comparison of almost all old data with future work while referring to an international measurement standard. In particular, canonical δ98/95Mo values such as +2.3‰ for seawater and −0.7‰ for marine Fe–Mn precipitates can be kept for discussion. As recent publications show that the ocean molybdenum isotope signature is homogeneous, the IAPSO ocean water standard or any other open ocean water sample is suggested as a secondary measurement standard, with a defined δ98/95Mo value of +2.34 ± 0.10‰ (2s). Les isotopes du molybdène (Mo) sont de plus en plus largement utilisés dans les sciences de la Terre. Ils sont principalement utilisés pour étudier l'oxygénation de l'océan et de l'atmosphère de la Terre. Cependant, de plus en plus de domaines d'application sont en cours de développement, tels que ceux concernant les processus magmatiques et hydrothermaux, les sciences planétaires ou encore le suivi de la pollution environnementale. Ici, nous présentons une proposition de présentation unifiée des rapports isotopiques du Mo dans les études du fractionnement isotopique dépendant de la masse. Nous suggérons que le δ98/95Mo du NIST SRM 3134 soit définit comme étant égal à +0.25 ‰. La raison est que la grande majorité des données publiées sont présentés par rapport à des matériaux de référence qui sont similaires, mais pas identiques, et qui sont tous légèrement plus léger que le NIST SRM 3134. Notre proposition de présentation des données permet une comparaison directe au premier ordre de presque toutes les anciennes données avec les travaux futurs en se référant à un standard international. En particulier, les valeurs canoniques du δ98/95Mo comme celle de +2,3 ‰ pour l'eau de mer et de -0,7 ‰ pour les précipités de Fe-Mn marins peuvent être conservés pour la discussion. Comme les publications récentes montrent que la signature isotopique moyenne du molybdène de l'océan est homogène, le standard de l'eau océanique IAPSO ou tout autre échantillon d'eau provenant de l'océan ouvert sont proposé comme standards secondaires, avec une valeur définie du δ98/95 Mo de 2.34 ± 0.10 ‰ (2s).
Resumo:
In spring 2012 CERN provided two weeks of a short bunch proton beam dedicated to the neutrino velocity measurement over a distance of 730 km. The OPERA neutrino experiment at the underground Gran Sasso Laboratory used an upgraded setup compared to the 2011 measurements, improving the measurement time accuracy. An independent timing system based on the Resistive Plate Chambers was exploited providing a time accuracy of ∼1 ns. Neutrino and anti-neutrino contributions were separated using the information provided by the OPERA magnetic spectrometers. The new analysis profited from the precision geodesy measurements of the neutrino baseline and of the CNGS/LNGS clock synchronization. The neutrino arrival time with respect to the one computed assuming the speed of light in vacuum is found to be δtν≡TOFc−TOFν=(0.6±0.4 (stat.)±3.0 (syst.)) ns and δtν¯≡TOFc−TOFν¯=(1.7±1.4 (stat.)±3.1 (syst.)) ns for νμ and ν¯μ, respectively. This corresponds to a limit on the muon neutrino velocity with respect to the speed of light of −1.8×10−6<(vν−c)/c<2.3×10−6 at 90% C.L. This new measurement confirms with higher accuracy the revised OPERA result.
Resumo:
This paper presents the performance of the ATLAS muon reconstruction during the LHC run with pp collisions at √s = 7–8 TeV in 2011–2012, focusing mainly on data collected in 2012. Measurements of the reconstruction efficiency and of the momentum scale and resolution, based on large reference samples of J/ψ → μμ, Z → μμ and ϒ → μμ decays, are presented and compared to Monte Carlo simulations. Corrections to the simulation, to be used in physics analysis, are provided. Over most of the covered phase space (muon |η| < 2.7 and 5 ≲ pT ≲ 100 GeV) the efficiency is above 99% and is measured with per-mille precision. The momentum resolution ranges from 1.7% at central rapidity and for transverse momentum pT ≅ 10 GeV, to 4% at large rapidity and pT ≅ 100 GeV. The momentum scale is known with an uncertainty of 0.05% to 0.2% depending on rapidity. A method for the recovery of final state radiation from the muons is also presented.
Resumo:
The OPERA detector, designed to search for νμ → ντ oscillations in the CNGS beam, is located in the underground Gran Sasso laboratory, a privileged location to study TeV-scale cosmic rays. For the analysis here presented, the detector was used to measure the atmospheric muon charge ratio in the TeV region. OPERA collected chargeseparated cosmic ray data between 2008 and 2012. More than 3 million atmospheric muon events were detected and reconstructed, among which about 110000 multiple muon bundles. The charge ratio Rμ ≡ Nμ+/Nμ− was measured separately for single and for multiple muon events. The analysis exploited the inversion of the magnet polarity which was performed on purpose during the 2012 Run. The combination of the two data sets with opposite magnet polarities allowedminimizing systematic uncertainties and reaching an accurate determination of the muon charge ratio. Data were fitted to obtain relevant parameters on the composition of primary cosmic rays and the associated kaon production in the forward fragmentation region. In the surface energy range 1–20 TeV investigated by OPERA, Rμ is well described by a parametric model including only pion and kaon contributions to themuon flux, showing no significant contribution of the prompt component. The energy independence supports the validity of Feynman scaling in the fragmentation region up to 200 TeV/nucleon primary energy.
Resumo:
Lovell and Rouse (LR) have recently proposed a modification of the standard DEA model that overcomes the infeasibility problem often encountered in computing super-efficiency. In the LR procedure one appropriately scales up the observed input vector (scale down the output vector) of the relevant super-efficient firm thereby usually creating its inefficient surrogate. An alternative procedure proposed in this paper uses the directional distance function introduced by Chambers, Chung, and Färe and the resulting Nerlove-Luenberger (NL) measure of super-efficiency. The fact that the directional distance function combines features of both an input-oriented and an output-oriented model, generally leads to a more complete ranking of the observations than either of the oriented models. An added advantage of this approach is that the NL super-efficiency measure is unique and does not depend on any arbitrary choice of a scaling parameter. A data set on international airlines from Coelli, Perelman, and Griffel-Tatje (2002) is utilized in an illustrative empirical application.