996 resultados para marine hydrokinetic devices
Resumo:
Pycnadenoides pagrosomi Yamaguti, 1938 and P. reversati n. sp. from Pagrus auratus (Sparidae) and P. invenustus n. sp. from Nemadactylus valenciennesi (Cheilodactylidae) are described from the temperate marine waters off south-west Western Australia and south-east Queensland. The difference in the anterior extent of the vitelline follicles observed in P. reversati n. sp. recovered from off south-east Queensland waters and the material from off Western Australia is discussed. P. reversati n. sp. is distinguished from P. pagrosomi mainly in the position of the genital pore and in the arrangement of the testes, and from P. invenustus n. sp. in the posterior extent of the cirrus-sac. P. reversati belongs to the group of species with a short cirrus-sac and P. invenustus to the group with the cirrus-sac reaching into the anterior hindbody.
Resumo:
An opecoelid, Bartoliella pritchardae n. g., n. sp., is described from the intestine of Epinephelides armatus from Western Australia. The new genus has been assigned to the subfamily Opecoelininae Gibson & Bray, 1984, bringing the number of genera in the subfamily to two. Although the new genus is similar to Opecoelina Manter, 1934 morphologically, the pedunculate ventral sucker and complete absence of a cirrus-sac necessitate the erection of a new genus. A formal re-definition of the subfamily is given, based on the diagnoses of the genera Opecoelina and Bartoliella n. g.
Resumo:
A new species of Allopodocotyle Pritchard, 1966 is described from the intestine and pyloric caeca of Parequula melbournensis (Gerreidae) caught from the waters off South and Western Australia. The new species is distinguished from other species by its larger eggs, broader form, pre-bifurcal genital pore and a number of other measurable features that are discussed. Of the species that share morphological similarities with Allopodocotyle skoliorchis n. sp., it is the only species known from a gerreid; all the other species are from serranids.
Resumo:
A new species of Podocotyloides is described from Sillago bassensis caught off the coast of Western Australia. This is the second report of a species of this genus from Australian waters but the first of a new species. P. victori n. sp. is one of four species whose vitelline follicles extend into the forebody. It is distinguished from the other three species with vitelline follicles in the forebody by its relatively shorter forebody, smaller eggs and bipartite seminal vesicle. Pedunculotrema Fischthal & Thomas, 1970 is reduced to synonymy with Podocotyloides Yamaguti, 1934.
Resumo:
We investigate coherent electron transport through a parallel circuit of two quantum dots (QDs), each of which has a single tunable. energy level. Electrons tunnelling via each dot from the left lead interfere with each other at the right lead. It is shown that due to the quantum interference of tunnelling electrons the double QD device is magnetically polarized by coherent circulation of electrons on the closed path through the dots and the leads. By varying the energy level of each dot one can make the magnetic states of the device be up-, non- or down-polarized. It is shown that for experimentally accessible temperatures and applied biases the magnetic polarization currents Should be sufficiently large to observe with current nanotechnology.
Resumo:
Although the 12-lead electrocardiogram has become an essential medical and research tool, many current and envisaged applications would benefit from simpler devices, using 3-lead ECG configuration. This is particularly true for Ambient Assisted Living (in a broad perspective). However, the chest anatomy of female patients, namely during pregnancy, can hamper the adequate placement of a 3-lead ECG device and, very often, electrodes are placed below the chest rather than at the precise thoracic landmarks. Thus, the aim of this study was to compare the effect of electrode positioning on the ECG signal of pregnant women and provide guidelines for device development. The effect of breast tissue on the ECG signal was investigated by relating breast size with the signal-to-noise ratio, root mean square and R-wave amplitude. Results show that the 3-lead ECG should be placed on the breast rather than under the breast and indicate positive correlation between breast size and signal-to-noise ratio.
Resumo:
Objective: To describe the importance of training multiple sclerosis (MS) patients with auxiliary walking devices (walking stick, crutch, or wheelchair) in a way that achieves a better quality of life (QOL). Design: Exploratory and descriptive. Setting: General hospital in Portugal.
Resumo:
Heart failure is the final stage of most of cardiac diseases. It is a complex syndrome in which the patients should have the following features: symptoms of heart failure, typically shortness of breath at rest or during exertion, and/or fatigue; signs of fluid retention such as pulmonary congestion or ankle swelling; and objective evidence of an abnormality of the structure or function of the heart at rest. This progressive syndrome as a high incidence and prevalence and poor prognosis: four-year mortality is around 50% with 40% of the patients admitted to hospital dying or readmitted within a year. With ageing, many patients will develop chronic heart failure, which, because of its symptoms, patient’s awareness of their risk of dying, and the effects of therapy, together with frequent hospitalizations, has considerable impact on patient’s health-related quality of life.
Resumo:
In this paper we present results on the optimization of multilayered a-SiC:H heterostructures for wavelength-division (de) multiplexing applications. The non selective WDM device is a double heterostructure in a glass/ITO/a-SiC:H (p-i-n) /a-SiC:H(-p) /a-Si:H(-i')/a-SiC:H (-n')/ITO configuration. The single or the multiple modulated wavelength channels are passed through the device, and absorbed accordingly to its wavelength, giving rise to a time dependent wavelength electrical field modulation across it. The effect of single or multiple input signals is converted to an electrical signal to regain the information (wavelength, intensity and frequency) of the incoming photogenerated carriers. Here, the (de) multiplexing of the channels is accomplished electronically, not optically. This approach offers advantages in terms of cost since several channels share the same optical components; and the electrical components are typically less expensive than the optical ones. An electrical model gives insight into the device operation.
Resumo:
In this review paper different designs based on stacked p-i'-n-p-i-n heterojunctions are presented and compared with the single p-i-n sensing structures. The imagers utilise self-field induced depletion layers for light detection and a modulated laser beam for sequential readout. The effect of the sensing element structure, cell configurations (single or tandem), and light source properties (intensity and wavelength) are correlated with the sensor output characteristics (light-to-dark sensivity, spatial resolution, linearity and S/N ratio). The readout frequency is optimized showing that scans speeds up to 104 lines per second can be achieved without degradation in the resolution. Multilayered p-i'-n-p-i-n heterostructures can also be used as wavelength-division multiplexing /demultiplexing devices in the visible range. Here the sensor element faces the modulated light from different input colour channels, each one with a specific wavelength and bit rate. By reading out the photocurrent at appropriated applied bias, the information is multiplexed or demultiplexed and can be transmitted or recovered again. Electrical models are present to support the sensing methodologies.
Resumo:
In this paper we present results on the optimization of device architectures for colour and imaging applications, using a device with a TCO/pinpi'n/TCO configuration. The effect of the applied voltage on the color selectivity is discussed. Results show that the spectral response curves demonstrate rather good separation between the red, green and blue basic colors. Combining the information obtained under positive and negative applied bias a colour image is acquired without colour filters or pixel architecture. A low level image processing algorithm is used for the colour image reconstruction.