960 resultados para light sources
Resumo:
This study evaluated color change, stability, and tooth sensitivity in patients submitted to different bleaching techniques. Material and methods: In this study, 48 patients were divided into five groups. A half-mouth design was conducted to compare two in-office bleaching bleaching techniques (with and without light activation): G1: 35% hydrogen peroxide (HP) (Lase Peroxide - DMC Equipments, Sao Carlos, SP, Brazil) + hybrid light (HL) (LED/Diode Laser, Whitening Lase II DMC Equipments, Sao Carlos, SP, Brazil); G2: 35% HP; G3: 38% HP (X-traBoost - Ultradent, South Jordan UT, USA) + HL; G4: 38% HP; and G5: 15% carbamide peroxide (CP) (Opalescence PF - Ultradent, South Jordan UT, USA). For G1 and G3, HP was applied on the enamel surface for 3 consecutive applications activated by HL. Each application included 3x3' HL activations with 1' between each interval; for G2 and G4, HP was applied 3x15' with 15' between intervals; and for G5, 15% CP was applied for 120'/10 days at home. A spectrophotometer was used to measure color change before the treatment and after 24 h, 1 week, 1, 6, 12, 18 and 24 months. A VAS questionnaire was used to evaluate tooth sensitivity before the treatment, immediately following treatment, 24 h after and finally 1 week after. Results: Statistical analysis did not reveal any significant differences between in-office bleaching with or without HL activation related to effectiveness; nevertheless the time required was less with HL. Statistical differences were observed between the result after 24 h, 1 week and 1, 6, 12, 18 and 24 months (integroup). Immediately, in-office bleaching increased tooth sensitivity. The groups activated with HL required less application time with gel. Conclusion: All techniques and bleaching agents used were effective and demonstrated similar behaviors.
Resumo:
Aiming to compare the effect of different light sources for dental bleaching on vascular permeability of dental pulps, forty-eight incisors were used. The bleaching agent (35% hydrogen peroxide) was activated by halogen light; LED (Light Emitting Diode) or LED, followed by laser phototherapy (LPT) (lambda = 780 nm; 3 J/cm(2)). After the bleaching procedures, the animals received an intra-arterial dye injection and one hour later were sacrificed. The teeth were diaphanized and photographed. The amount of blue stain content of each dental pulp was quantified using a computer imaging program. The data was statistically compared (p <= 0.05). The results showed a significant higher (p <= 0.01) dye content in the groups bleached with halogen light, compared with the control, LED and LED plus LPT groups. Thus, tooth bleaching activated by LED or LED plus LPT induces lesser resulted in increased vascular permeability than halogen light.
Resumo:
Aiming to compare the effect of different light sources for dental bleaching on vascular permeability of dental pulps, forty-eight incisors were used. The bleaching agent (35 % hydrogen peroxide) was activated by halogen light; LED (Light Emitting Diode) or LED, followed by laser phototherapy (LPT) (λ = 780 nm; 3 J/cm²). After the bleaching procedures, the animals received an intra-arterial dye injection and one hour later were sacrificed. The teeth were diaphanized and photographed. The amount of blue stain content of each dental pulp was quantified using a computer imaging program. The data was statistically compared (p < 0.05). The results showed a significant higher (p < 0.01) dye content in the groups bleached with halogen light, compared with the control, LED and LED plus LPT groups. Thus, tooth bleaching activated by LED or LED plus LPT induces lesser resulted in increased vascular permeability than halogen light.
Resumo:
Introduction: Laser hair removal is becoming an increasingly popular alternative to traditional methods such as shaving, waxing, among other methods. Semiconductor diode lasers are considered the most efficient light sources available and are especially well suited for clinical applications including hair reduction. The effectiveness of laser hair reduction depends on many variables, including the skin type of the patient. Material and Methods: A patient with Fitzpatrick Skin Type IV was submitted to laser hair removal of the arms with a high-power diode laser system with long pulses with a wavelength of 800 nm, a fluence of 40 J/cm2 and a pulse width of 20 ms. A 12-month follow-up assessment was performed and included photography and questionnaire. Results: Hypopigmentation was observed after a single laser hair removal section. After 6 months with the area totally covered, a gradual suntan with a sun screen lotion with an SPF of 15 was prescribed by the dermatologist. After 12 months of the initial treatment, a complete recovery of the hypopigmentation was achieved. Conclusion: Although a safe procedure, lasers for hair removal may be associated with adverse side effects including undesired pigment alterations. Before starting a laser hair removal treatment, patients seeking the eradication of hair should be informed that temporary, and possibly permanent, pigmentary changes may occur.
Resumo:
The European Committee for Standardization is working on a standard for the application of IPM (Integrated Pest Management) in museums and cultural heritage facilities. Since one of the aims of this research was to verify the approach against pests adopted in Italian conservation facilities, a survey was conducted. The results show that for the Italian museums, archives, libraries and historical houses pests are a problem, but IPM is unknown and prevention programmes to avoid damages caused by them, are not applied. In the most of cases pests problems are solved only when the risk is high and damages are visible. Also entomological monitoring, which represents a crucial part of IPM and could be very useful, is not included among the ordinary prevention activities. In addition, at present, the scientific researches on entomological traps, whether light or pheromones, for “cultural heritage pests” is extremely poor and only recently the behaviour and/or the physiology of the insects “of museums” have been investigated. For these reasons, tests to increase the traps using are performed. In particular, S. paniceum behaviour towards different attraction systems was investigated and the results indicate that the light traps efficiency could be improved using specific wavelengths and light sources.
Resumo:
In dieser Arbeit wird die Entwicklung und experimentelle Umsetzung einer kontinuierlichen, kohärenten Lichtquelle im vakuumultravioletten Wellenlängenbereich um 122 nm präsentiert. Diese basiert auf der nichtlinearen optischen Summenfrequenzmischung dreier Fundamentallaserstrahlen in einer mit Quecksilberdampf gefüllten Hohlfaser. Die Wellenlängen der fundamentalen Laser sind dabei an der Niveaustruktur des Quecksilbers orientiert, um eine mehrfach resonante Überhöhung der nichtlinearen Suszeptibilität zu erreichen. Der transversale Einschluss der Lichtfelder in der Faser verlängert die Wechselwirkungszone mit dem nichtlinearen Medium um mehrere Größenordnungen gegenüber dem Regime fokussierter Strahlen und erlaubt so signifikante Steigerungen der Mischeffizienz.rnrnIm Zuge dieser Arbeit wurde neben einer umfassenden mathematischen Analyse des nichtlinearen Mischprozesses unter Einfluss der Fasercharakteristika eine Apparatur zur Erzeugung und Detektion vakuumultravioletter Strahlung entwickelt. Die Generierung ausreichend hoher Dampfdichten innerhalb des 50 µm durchmessenden Faserkerns konnten spektroskopisch nachgewiesen werden.rnrnDas erste erfolgreiche Summenfrequenzmischen zu 121,26 nm in der Faser wurde demonstriert. Die erzielten Mischeffizienzen sind bereits mit denen vergleichbar, welche unter Verwendung fokussierter Strahlen erreicht werden, obwohl eine Phasenanpassung in der Faser bisher nicht möglich war. Die Ergebnisse dieser Arbeit markieren damit einen wichtigen Schritt hin zu Leistungssteigerungen kohärenter, kontinuierlicher vakuumultravioletter Lichtquellen.rnrnEine solche Quelle wird für zukünftige Laserkühlung von magnetisch gefangenem Antiwasserstoff auf dem Lyman-Alpha Übergang, sowie die Rydberganregung von Calciumionen in einer Paulfalle zur Implementierung quantenlogischer Operationen benötigt.rnrnFerner hat eine Untersuchung der, für eine effiziente Konversion essentiellen, 6^1S_0 - 7^1S_0 Zwei-Photonen Resonanz in Quecksilber Hinweise auf eine bis dato experimentell nicht beobachtete, auf einer Mehr-Photonen Anregung beruhende Licht-induzierte Drift ergeben.
Resumo:
Vitiligo is a relatively common acquired disorder, characterized by progressive loss of melanocytes from the epidermis and the epidermal appendages. The disease is associated with considerable morbidity because of a major impact on the quality of life. The treatment for vitiligo is generally unsatisfactory and challenging. There are a variety of therapeutic possibilities including topical corticosteroids, topical calcineurin inhibitors, as well as phototherapy with Psoralen plus UVA (PUVA), narrow-band UVB, and a 308-nm excimer laser and/or lamps. Furthermore, surgical methods encompass grafting and transplantation while depigmentation treatments and psychological support may also be considered. The objective is to assess the effect of the 380-nm excimer laser in the treatment of vitiligo based on the available studies and case series. We searched the relevant literature about vitiligo and excimer laser published between 1990 and 2012 using the MEDLINE database. We reviewed all relevant articles about 308-nm excimer laser and light sources assessing their efficacy in the management of vitiligo as well as their side effects. The value of combination treatment methods was also analyzed. The available studies provide strong evidence that the excimer laser represents the most effective approach to treat vitiligo compared to ordinary phototherapy. Excimer laser is relatively safe and effective for localized disease. UV-sensitive areas respond best as well as a short duration of the disease. More frequent treatments achieve better results. Compared to other treatment modalities, the excimer laser most likely constitutes the treatment of choice for localized vitiligo. Its efficacy can be further improved in combination with other therapies such as corticosteroids, pimecrolimus, or tacrolimus.
Resumo:
The efficacy of photodynamic therapy (PDT) with 5-aminolevulinate and methyl aminolevulinate in the treatment of actinic keratosis has been demonstrated in a large number of clinical studies over the last several years. Here, we recapitulate the major findings, comparing the various photosensitizers, light sources and therapeutic regimens, and present a retrospective analysis of 142 own cases treated with 259 PDTs. In addition, we also discuss the value of PDT in comparison with cryotherapy or 5-fluorouracil. The efficacy and the low risk of side effects of PDT have resulted in a high patient preference in clinical trials.
Resumo:
Interactive TV technology has been addressed in many previous works, but there is sparse research on the topic of interactive content broadcasting and how to support the production process. In this article, the interactive broadcasting process is broadly defined to include studio technology and digital TV applications at consumer set-top boxes. In particular, augmented reality studio technology employs smart-projectors as light sources and blends real scenes with interactive computer graphics that are controlled at end-user terminals. Moreover, TV producer-friendly multimedia authoring tools empower the development of novel TV formats. Finally, the support for user-contributed content raises the potential to revolutionize the hierarchical TV production process, by introducing the viewer as part of content delivery chain.
Resumo:
This year marks the 20th anniversary of functional near-infrared spectroscopy and imaging (fNIRS/fNIRI). As the vast majority of commercial instruments developed until now are based on continuous wave technology, the aim of this publication is to review the current state of instrumentation and methodology of continuous wave fNIRI. For this purpose we provide an overview of the commercially available instruments and address instrumental aspects such as light sources, detectors and sensor arrangements. Methodological aspects, algorithms to calculate the concentrations of oxy- and deoxyhemoglobin and approaches for data analysis are also reviewed. From the single-location measurements of the early years, instrumentation has progressed to imaging initially in two dimensions (topography) and then three (tomography). The methods of analysis have also changed tremendously, from the simple modified Beer-Lambert law to sophisticated image reconstruction and data analysis methods used today. Due to these advances, fNIRI has become a modality that is widely used in neuroscience research and several manufacturers provide commercial instrumentation. It seems likely that fNIRI will become a clinical tool in the foreseeable future, which will enable diagnosis in single subjects.
Resumo:
Tiled projector displays are a common choice for training simulators, where a high resolution output image is required. They are cheap for the resolution that they can reach and can be configured in many different ways. Nevertheless, such kinds of displays require geometric and color correction so that the composite image looks seamless. Display correction is an even bigger challenge when the projected images include dark scenes combined with brighter scenes. This is usually a problem for railway simulators when the train is positioned inside a tunnel and the black offset effect becomes noticeable. In this paper, a method for fast photometric and geometric correction of tiled display systems where dark and bright scenes are combined is presented. The image correction is carried out in two steps. First, geometric alignment and overlapping areas attenuation for brighter scenes is applied. Second, in the event of being inside a tunnel, the brightness of the scene is increased in certain areas using light sources in order to create the impression of darkness but minimizing the effect of the black offset
Resumo:
Mealiness is a textural attribute related to an internal fruit disorder that involves quality loss. It is characterised by the combination of abnormal softness of the fruit and absence of free juiciness in the mouth when eaten by the consumer. Recent research concluded with the development of precise instrumental procedure to measure a scale of mealiness based on the combination of several rheological properties and empirical magnitudes. In this line, time-domain laser reflectance spectroscopy (TDRS) is a medical technology, new in agrofood research, which is capable of obtaining physical and chemical information independently and simultaneously, and this can be of interest to characterise mealiness. Using VIS & NIR lasers as light sources, TDRS was applied in this work to Golden Delicious and Cox apples (n=90), conforming several batches of untreated samples and storage-treated (20°C & 95%RH) to promote the development of mealiness. The collected database was clustered into different groups according to their instrumental test values (Barreiro et al, 1998). The optical coefficients were used as explanatory variables when building discriminant analysis functions for mealiness, achieving a classification score above 80% of correctly identified mealy versus fresh apples.
Resumo:
In SSL general illumination, there is a clear trend to high flux packages with higher efficiency and higher CRI addressed with the use of multiple color chips and phosphors. However, such light sources require the optics provide color mixing, both in the near-field and far-field. This design problem is specially challenging for collimated luminaries, in which diffusers (which dramatically reduce the brightness) cannot be applied without enlarging the exit aperture too much. In this work we present first injection molded prototypes of a novel primary shell-shaped optics that have microlenses on both sides to provide Köhler integration. This shell is design so when it is placed on top of an inhomogeneous multichip Lambertian LED, creates a highly homogeneous virtual source (i.e, spatially and angularly mixed), also Lambertian, which is located in the same position with only small increment of the size (about 10-20%, so the average brightness is similar to the brightness of the source). This shell-mixer device is very versatile and permits now to use a lens or a reflector secondary optics to collimate the light as desired, without color separation effects. Experimental measurements have shown optical efficiency of the shell of 95%, and highly homogeneous angular intensity distribution of collimated beams, in good agreement with the ray-tracing simulations.
Resumo:
En la búsqueda de dispositivos cada vez más eficientes, de larga duración y bajo coste de mantenimiento en el mundo de la iluminación, aparecen los LEDs. Estos pequeños dispositivos van poco a poco sustituyendo a las bombillas tradicionales de incandescencia, tomando un papel cada vez más importante entre las fuentes de iluminación. Las primeras funciones prácticas que tuvieron estos LEDs fueron como indicadores, y sus primeros usos fueron en pantallas de calculadoras, electrodomésticos, etcétera, y más adelante, con el desarrollo de nuevos materiales, se empezaron a utilizar como dispositivos de iluminación. Ha sido en estos últimos años cuando se ha producido un salto cuantitativo gracias a la aparición de los POWER LED (LEDs de potencia) o de alto brillo, que son los que han permitido ampliar el uso de estos dispositivos como fuentes de iluminación en, por ejemplo, hogares, alumbrado público, e incluso llegando a sustituir los faros halógenos de vehículos por iluminación LED en algunos modelos. Es por ello que mientras su potencia lumínica va aumentado, su rango de utilización también lo hace. Para caracterizar estas fuentes lumínicas y otras a las que se les pueden dar diferentes usos, se desarrolla este proyecto mediante el análisis de su espectro. Para ello, además, se hará un análisis del resto de instrumentación necesaria que forma parte del proyecto. Este análisis abarca el estudio del propio espectrómetro tanto a nivel de hardware como de software, que modificaremos según los intereses del proyecto. También se estudiará la fibra óptica y el driver para controlar los dispositivos LEDs de potencia, así como los propios LEDs. Para ello se medirán las características de estos LEDs y se compararán con las facilitadas por el fabricante. ABSTRACT. Searching for more efficient, long lasting an low-maintenance devices in lighting world, LEDs appear. These small devices are gradually replacing traditional incandescent bulbs. LEDs are taking an increasingly important role between the light sources. At the begining they were only used as indicators and their first use were in screens calculators, appliances, etc., and later, with the development of new materials, were progressively used as lighting devices. Nowadays a great development has happened in LED lighting with the apparition of the POWER LED or high bright. Power LEDs are allowed to extend the use of these devices as lighting sources for example for homes, street lighting, and even coming to replace halogen headlights LED lighting in vehicles of some models. That's the reason the more their lighting power increases the more their use increases too. The aim of this project is to characterize these light sources and others that can be given different uses by analyzing its spectrum. Moreover, necessary instruments will also be analysed. This study involves both hardware and software spectrometer analysis itself by modifying its software according to the interests of the project. Furthermore, optical fiber and the driver to control LED power devices will be studied by measuring LEDs characteristics and comparing with those provided by the manufacturer.
Resumo:
Mealiness is a textural attribute related to an internal fruit disorder that involves quality loss. It is characterised by the combination of abnormal softness of the fruit and absence of free juiciness in the mouth when eaten by the consumer. Recent research concluded with the development of precise instrumental procedure to measure a scale of mealiness based on the combination of several rheological properties and empirical magnitudes. In this line, time-domain laser reflectance spectroscopy (TDRS) is a new medical technology, used to characterise the optical properties of tissues, and to locate affected areas like tumours. Among its advantages compared to more traditional spectroscopic techniques, there is the feasibility to asses simultaneously and independently two optical parameters: the absorption of the light inside the irradiated body, and the scattering of the photons across the tissues, at each wavelength, generating two coefficients (µa, absorption coeff.; and µ's, transport scattering coeff.). If it is assumed that they are related respectively to chemical components and to physical properties of the sample, TDRS can be applied to the quantification of chemicals and the measurement of the rheological properties (i.e. mealiness estimation) at the same time. Using VIS & NIR lasers as light sources, TDRS was applied in this work to Golden Delicious and Cox apples (n=90), conforming several batches of untreated samples and storage-treated (20°C & 95%RH) to promote the development of mealiness. The collected database was clustered into different groups according to their instrumental test values (Barreiro et al, 1998). The optical coefficients were used as explanatory variables when building discriminant analysis functions for mealiness, achieving a classification score above 80% of correctly identified mealy versus fresh apples.