950 resultados para internal audit function


Relevância:

30.00% 30.00%

Publicador:

Resumo:

Economic Dispatch (ED) problems have recently been solved by artificial neural networks approaches. In most of these dispatch models, the cost function must be linear or quadratic. Therefore, functions that have several minimum points represent a problem to the simulation since these approaches have not accepted nonlinear cost function. Another drawback pointed out in the literature is that some of these neural approaches fail to converge efficiently towards feasible equilibrium points. This paper discusses the application of a modified Hopfield architecture for solving ED problems defined by nonlinear cost function. The internal parameters of the neural network adopted here are computed using the valid-subspace technique, which guarantees convergence to equilibrium points that represent a solution for the ED problem. Simulation results and a comparative analysis involving a 3-bus test system are presented to illustrate efficiency of the proposed approach.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Groups of Wistar rats were fed with ration doped with uranyl nitrate at concentration A ranging from 0.5 to 100 ppm, starting after the weaning period and lasting until the postpuberty period when the animals were sacrificed. Uranium in the ashes of bones was determined by neutron activation analysis. It was found that the uranium concentration in the bones. as a function of A, exhibits a change in its slope at similar to20 ppm-a probable consequence of the malfunctioning of kidneys. The uranium transfer coefficient was obtained and an analytical expression was fitted into the data. thus allowing extrapolation down to low doses. Internal and localized doses were calculated. Absorbed doses exceeded the critical dose. even for the lowest uranium dosage.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

We have measured internal friction and frequency as a function of temperature in molybdenum containing oxygen and nitrogen in solid solution. These measurements were performed by a torsion pendulum operating in the temperature range of 300 K to 700 K with oscillation frequency about 1.0 Hz. The results showed the complex relaxation process identifying the stress induced ordering of oxygen and nitrogen atom around the molybdenum atoms of the metallic matrix.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The aim of this study was to demonstrate that hypertrophied cardiac muscle is more sensitive to volume-overload than normal cardiac muscle. We assessed the mechanical function of isolated left ventricular papillary muscle from male spontaneously hypertensive rats (SHR) and age-matched normotensive Wistar-Kyoto rats (WKY) Submitted to volume overload caused by aortocaval fistula (ACF) for 30 days. Muscles were perfused with Krebs-Henseleit solution at 28degreesC and Studied isometrically at a Stimulation rate of 0.2 Hz. The ACF increased the right and left ventricular weight-to-body weight ratio in WKY rats; it also promoted right ventricular hypertrophy and further increased the basal hypertrophy in the left ventricle from SHR. The arterial systolic pressure was greater in SHR than in WKY rats, and decreased with ACF in both groups. Developed tension (DT) and maximum rate of DT (+dT/dt) were greater in the SHR-control than in the WKY-control (P<0.05); the time from peak tension to 50% relaxation (RT1/2) was similar in these animals. ACE did not change any parameters ill the SHR group and increased the resting tension in the WKY group. However, the significant difference observed between myocardial contraction performance in WKY-controls and SHR-controls disappeared when the SHR-ACF and WKY-controls were compared. Furthermore, RT1/2 increased significantly ill the SHR-ACF in relation to the WKY-controls. In conclusion, the data lead LIS to infer that volume-overload for 30 days promotes more mechanical functional changes in hypertrophied muscle than in normal cardiac muscle.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Internal friction and frequency measurements as a function of temperature have been carried out in Nb and Nb-Zr policrystalline samples, using a torsion pendulum in the temperature range between 300K and 700K the heating rate was 1K/min and the pressure was kept better than 5x10(-3) mbar. Metals with bce lattice containing solute atoms dissolved interstitially often show anelastic behaviour due to a process know as stress-induced ordering responsible for the appearance of Snoek peaks. In the Nb sample it has been identified two constituent peaks corresponding to the interstitial-matrix interactions (Nb-O and Nb-N), but for the Nb-Zr samples with interstitial solute concentrations very close to those measured for the unalloyed Nb, it was not observed any mechanical relaxation peaks due to the presence of oxygen and nitrogen in solid solution.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

There is still controversy about the relation between changes in myocardial contractile function and global left ventricular (LV) performance during stable concentric hypertrophy. To clarify this, we analyzed LV function in vivo and myocardial mechanics in vitro in rats with pressure overload-induced cardiac hypertrophy. Male Wistar rats (70 g) Underwent ascending aortic stenosis for 8 weeks (group AAS, n = 9). LV performance wits assessed by transthoracic echocardiography Under anesthesia. Myocardial function Was studied in isolated papillary muscle preparations during isometric contraction. The data were compared with age- and sex-matched sham-operated rats (group C, 11 = 9). LV weight-to-body weight ratio (C: 2.13 +/- 0.14 mg/g; AAS: 3.24 +/- 0.44) LV relative wall thickness (C: 0.18 +/- 0.02; AAS: 0.33 +/- 0.09), and LV fractional shortening (C: 54 +/- 5%; AAS: 70 +/- 8%) were increased in group AAS (P<0.05). Echocardio-graphic analysis also indicated a significant association (r = 0.74 P<0.001) between the percent fractional shortening index and LV relative wall thickness. The performance of AAS isolated In muscle revealed that active tension (C: 6.6 +/- 1.7 g/mm(2); AAS: 6.5 +/- 1.5 g/mm(2)) and maximum rate of tension development (C: 69 +/- 21 g/mm(2)/s AAS: 69 +/- 18 g/mm(2)/s) were not significantly different Front group C (P>0.05). In conclusion, compensated pressure-overload myocardial hypertrophy is associated with preserved myocardial function and increased ventricular performance. The improved LV function might be due to the ventricular remodeling, characterized by an increased relative wall thickness.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

30.00% 30.00%

Publicador:

Resumo:

This work was carried out to determine the internal and external structures of Atta bisphaerica (Forel) nests. Six nests were excavated and during excavation, all data referring to chambers and tunnels were recorded. Three nests had been internally cement-moulded, which enabled a better view of the chamber and tunnel structures. Atta bisphaerica nests presented a similar structural pattern, varying only in the number of chambers as a function of external mound area. Chambers were spherical with two communication tunnels. Internal tunnels had an elliptical section, sometimes circular, indirectly linked to chambers through ramifications and directly through short tunnels. Entrance holes were linked to the area of highest chamber concentration by tunnels from the elliptical section, which led to the nest in a radial manner. Knowledge of the colony's three-dimensional architecture permits successful application of chemical control processes, reduces the quantity of product applied, and consequently diminishes costs and environmental damage.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The importance of thrombosis and anticoagulation in clinical practice is rooted firmly in several fundamental constructs that can be applied both broadly and globally. Awareness and the appropriate use of anticoagulant therapy remain the keys to prevention and treatment. However, to assure maximal efficacy and safety, the clinician must, according to the available evidence, choose the right drug, at the right dose, for the right patient, under the right indication, and for the right duration of time. The first International Symposium of Thrombosis and Anticoagulation in Internal Medicine was a scientific program developed by clinicians for clinicians. The primary objective of the meeting was to educate, motivate and inspire internists, cardiologists and hematologists by convening national and international visionaries, thought-leaders and dedicated clinician-scientists in Sao Paulo, Brazil. This article is a focused summary of the symposium proceedings. © Springer Science+Business Media, LLC 2009.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Objective: Biological and mechanical implant-abutment connection complications and failures are still present in clinical practice, frequently compromising oral function. The purpose of this study was to evaluate the reliability and failure modes of anterior single-unit restorations in internal conical interface (ICI) implants using step-stress accelerated life testing (SSALT). Materials and methods: Forty-two ICI implants were distributed in two groups (n = 21 each): group AT-OsseoSpeed™ TX (Astra Tech, Waltham, MA, USA); group SV-Duocon System Line, Morse Taper (Signo Vinces Ltda., Campo Largo, PR, Brazil). The corresponding abutments were screwed to the implants and standardized maxillary central incisor metal crowns were cemented and subjected to SSALT in water. Use-level probability Weibull curves and reliability for a mission of 50,000 cycles at 200 N were calculated. Differences between groups were assessed by Kruskal-Wallis along with Bonferroni's post-hoc tests. Polarized-light and scanning electron microscopes were used for failure analyses. Results: The Beta (β) value derived from use level probability Weibull calculation was 1.62 (1.01-2.58) for group AT and 2.56 (1.76-3.74) for group SV, indicating that fatigue was an accelerating factor for failure of both groups. The reliability for group AT was 0.95 and for group SV was 0.88. Kruskal-Wallis along with Bonferroni's post-hoc tests showed no significant difference between the groups tested (P > 0.27). In all specimens of both groups, the chief failure mode was abutment fracture at the conical joint region and screw fracture at neck's region. Conclusions: Reliability was not different between investigated ICI connections supporting maxillary incisor crowns. Failure modes were similar. © 2012 John Wiley & Sons A/S.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)