A hybrid waveguide Bragg grating in optical fiber was fabricated and characterized, showing thermal responsivity of 211pm/°C. Proposed being used in fiber sensor, it demonstrates enhanced resolution by 20x and 2x for temperature and strain.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The microchannelled chirped fibre Bragg grating (MCFBG) was fabricated using femtosecond laser processing and HF-etching. Intrinsical refractive-index sensitivity induced by the microchannel makes MCFBGs ideal for biochemical sensing.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

We demonstrate a liquid level sensor based on the surrounding medium refractive index (SRI) sensing using of an excessively tilted fibre Bragg grating (ETFBG). The sensor has low thermal cross sensitivity and high SRI responsivity.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A 1.2 µm (height) × 125 µm (depth) × 500 µm (length) microslot along a fiber Bragg grating was engraved across the optical fiber by femtosecond laser patterning and chemical etching. By filling epoxy in the slot and subsequent UV curing, a hybrid waveguide grating structure with a polymer core and glass cladding was fabricated. The obtained device is highly thermally responsive with linear coefficient of 211 pm/°C.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A low-cost high-resolution wavelength-division-multiplexing (WDM) interrogation system operating around 800 nm region with operational bandwidth up to 60 nm and resolution of 12.7 pm utilizing a tilted fiber Bragg grating (TFBG) and a CCDarray detector has been implemented. The system has been evaluated for interrogating fiber Bragg grating based strain, temperature sensors, giving sensitivities of 0.59 pm/µe and 5.6 pm/°C, which are in good agreement with previously reported values. Furthermore, the system has been utilized to detect the refractive index change of sample liquids, demonstrating a capability of measuring index change as small as 10¯5. In addition, the vectorial expression of phase match condition and fabrication of TFBG have been discussed.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

We report on the fabrication and characterisation of a Bragg grating in multimode microstructured polymer optical fibre with a Bragg wavelength of 827nm. This is the smallest Bragg wavelength reported to date for a polymer optical fibre grating and the relatively low loss of the fibre at this wavelength considerably enhances the utility of the device compared to gratings at longer wavelengths.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Purpose To investigate the utility of uncorrected visual acuity measures in screening for refractive error in white school children aged 6-7-years and 12-13-years. Methods The Northern Ireland Childhood Errors of Refraction (NICER) study used a stratified random cluster design to recruit children from schools in Northern Ireland. Detailed eye examinations included assessment of logMAR visual acuity and cycloplegic autorefraction. Spherical equivalent refractive data from the right eye were used to classify significant refractive error as myopia of at least 1DS, hyperopia as greater than +3.50DS and astigmatism as greater than 1.50DC, whether it occurred in isolation or in association with myopia or hyperopia. Results Results are presented from 661 white 12-13-year-old and 392 white 6-7-year-old school-children. Using a cut-off of uncorrected visual acuity poorer than 0.20 logMAR to detect significant refractive error gave a sensitivity of 50% and specificity of 92% in 6-7-year-olds and 73% and 93% respectively in 12-13-year-olds. In 12-13-year-old children a cut-off of poorer than 0.20 logMAR had a sensitivity of 92% and a specificity of 91% in detecting myopia and a sensitivity of 41% and a specificity of 84% in detecting hyperopia. Conclusions Vision screening using logMAR acuity can reliably detect myopia, but not hyperopia or astigmatism in school-age children. Providers of vision screening programs should be cognisant that where detection of uncorrected hyperopic and/or astigmatic refractive error is an aspiration, current UK protocols will not effectively deliver.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

We demonstrate a novel glucose sensor based on an optical fiber grating with an excessively tilted index fringe structure and its surface modified by glucose oxidase (GOD). The aminopropyltriethoxysilane (APTES) was utilized as binding site for the subsequent GOD immobilization. Confocal microscopy and fluorescence microscope were used to provide the assessment of the effectiveness in modifying the fiber surface. The resonance wavelength of the sensor exhibited red-shift after the binding of the APTES and GOD to the fiber surface and also in the glucose detection process. The red-shift of the resonance wavelength showed a good linear response to the glucose concentration with a sensitivity of 0.298nm(mg/ml)-1 in the very low concentration range of 0.0∼3.0mg/ml. Compared to the previously reported glucose sensor based on the GOD-immobilized long period grating (LPG), the 81° tilted fiber grating (81°-TFG) based sensor has shown a lower thermal cross-talk effect, better linearity and higher Q-factor in sensing response. In addition, its sensitivity for glucose concentration can be further improved by increasing the grating length and/or choosing a higher-order cladding mode for detection. Potentially, the proposed techniques based on 81°-TFG can be developed as sensitive, label free and micro-structural sensors for applications in food safety, disease diagnosis, clinical analysis and environmental monitoring.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A potential low cost novel sensing scheme for monitoring absolute strain is demonstrated. The scheme utilizes a synthetic heterodyne interrogation technique working in conjunction with a linearly chirped, sinusoidally tapered, apodized Bragg grating sensor. The interrogation technique is relatively simple to implement in terms of the required optics and the peripheral electronics. This scheme generates an output signal that has a quasi-linear response to absolute strain with a static strain resolution of ~±20 με and an operating range of ~1000 με.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Summary form only given. A novel method for tuning the second and the third order dispersion using a simple multi-point bending device has been demonstrated. A simple model has been developed that allows to calculate the exact bending profile required for compensation for the given values of dispersion and dispersion slope.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

We present numerical modeling based on a combination of the Bidirectional Beam Propagation Method and Finite Element Method that completely describes the wavelength spectra of point by point femtosecond laser inscribed fiber Bragg gratings, showing excellent agreement with experiment. We have investigated the dependence of different spectral parameters such as insertion loss, all dominant cladding and ghost modes and their shape relative to the position of the fiber Bragg grating in the core of the fiber. Our model is validated by comparing model predictions with experimental data and allows for predictive modeling of the gratings. We expand our analysis to more complicated structures, where we introduce symmetry breaking; this highlights the importance of centered gratings and how maintaining symmetry contributes to the overall spectral quality of the inscribed Bragg gratings. Finally, the numerical modeling is applied to superstructure gratings and a comparison with experimental results reveals a capability for dealing with complex grating structures that can be designed with particular wavelength characteristics. (C) 2010 Optical Society of America

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Taste acuity for the bitter taste of 6-n-propylthiouracil (PROP) is a heritable trait. Some individuals perceive concentrated levels of PROP to taste extremely bitter (supertasters) or moderately bitter (medium tasters), whereas others detect only a mild taste or none at all (non-tasters). Heightened PROP acuity has been reported to be associated with greater acuity for a variety of compounds found in ordinary foods, although there are some inconsistent findings. The extent to which these compounds are perceived may affect food likes/dislikes and dietary intake. The majority of studies have tended to measure food likes and intake using questionnaires or laboratory preparations of a single taste quality. The present study used food diaries and sensory responses to real foods to be better able to generalise to real eating situations. There was no substantial evidence that genetically mediated taste acuity for PROP had a direct influence on food likes/dislikes or intake, although there was evidence that dietary restraint could have influenced these findings among the female samples. However; investigation of PROP tasting among individuals with coronary heart disease (CHD) and a control group suggested that PROP acuity could function as a genetic taste marker for heart disease and potentially other diet-related conditions. CHD was associated with decreased PROP acuity among men. This is consistent with the findings that decreased PROP acuity tended to be associated with increased likelihood to be a smoker and higher body mass index. It is concluded that there is not a simple and direct relationship between PROP tasting ability and food choice. An interaction between PROP acuity and other mediating factors may be involved in a more complex model of food choice. The evidence that PROP taste acuity may function as a genetic taste marker for coronary heart disease could have wide implications for understanding the aetiology, and ultimately the prevention, of diet-related disease.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

We describe how an acousto-optic tunable filter can be used to both demultiplex the signals from multiple fibre Bragg grating sensors and simultaneously provide wide bandwidth signal demodulation in a system using interferometric wavelength shift detection. In an experimental demonstration, the approach provided a noise limited strain resolution of 24.9 n epsilon Hz(-1/ 2) at 15 Hz.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

We present a thorough study on the development of a polymer optical fibre-based tuneable filter utilizing an intra-core Bragg grating that is electrically tuneable, operating at 1.55 µm. The Bragg grating is made tuneable using a thin-film resistive heater deposited on the surface of the fibre. The polymer fibre was coated via the photochemical deposition of a Pd/Cu metallic layer with the procedure induced by VUV radiation at room temperature. The resulting device, when wavelength tuned via Joule heating, underwent a wavelength shift of 2 nm for a moderate input power of 160 mW, a wavelength to input power coefficient of -13.4 pm mW-1 and time constant of 1.7 s-1. A basic theoretical study verified that for this fibre type one can treat the device as a one-dimensional system. The model was extended to include the effect of input electrical power changes on the refractive index of the fibre and subsequently to changes in the Bragg wavelength of the grating, showing excellent agreement with the experimental measurements.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Distributive tactile sensing is a method of tactile sensing in which a small number of sensors monitors the behaviour of a flexible substrate which is in contact with the object being sensed. This paper describes the first use of fibre Bragg grating sensors in such a system. Two systems are presented: the first is a one-dimensional metal strip with an array of four sensors, which is capable of detecting the magnitude and position of a contacting load. This system is favourably compared experimentally with a similar system using resistive strain gauges. The second system is a two-dimensional steel plate with nine sensors which is able to distinguish the position and shape of a contacting load, or the positions of two loads simultaneously. This system is compared with a similar system using 16 infrared displacement sensors. Each system uses neural networks to process the sensor data to give information concerning the type of contact. Issues and limitations of the systems are discussed, along with proposed solutions to some of the difficulties.