981 resultados para fixed path methods


Relevância:

30.00% 30.00%

Publicador:

Resumo:

BACKGROUND: People with disabilities have difficulties in obtaining work. However, evidence suggests that those with disabilities derive substantial mental health benefits from employment. This paper assesses how the relationship between work and mental health is influenced by psychosocial job quality for people working with a disability. METHODS: The study design was a longitudinal cohort with 13 annual waves of data collection, yielding a sample of 122,883 observations from 21,848 people. Fixed-effects within-person regression was used to control for time invariant confounding. The Mental Component Summary (MCS) of the Short Form 36 (SF-36) measure was used as the primary outcome measure. The main exposure was a six-category measure of psychosocial job quality and employment status (including 'not in the labour force' [NILF] and unemployment). Disability status ('no waves of disability reported' and 'all contributed waves with reported disability') was assessed as an effect modifier. We also conducted a secondary analysis on respondents contributing both disability and non-disability waves. RESULTS: For those with no disability, the greatest difference in mental health (compared to optimal employment) occurs when people have the poorest quality jobs (-2.12, 95% CI -2.48, -1.75, p < 0.001). The relative difference in mental health was less in relation to NILF and unemployment (-0.39 and -0.66 respectively). For those with consistent disability, the difference in mental health when employed in an optimal job was similar between the poorest quality jobs (-2.25, 95% CI -3.84, -0.65, p = 0.006), NILF (-2.84, 95% CI -4.49, -1.20, p = 0.001) or unemployment (-2.56, 95% CI -4.32, -0.80, p = 0.004). These results were confirmed by the secondary analysis. CONCLUSIONS: Efforts to improve psychosocial job quality may have significant mental health benefits for people with disabilities. This will contribute to the economic viability of disability employment insurance schemes in Australia and other high-income countries.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Background: In bovines, more efficient management practices are important for maximizing profitability. In order to increase the pregnancy rates in artificial insemination (AI) programs, several hormonal protocols were developed to synchronize the follicular wave and the moment of ovulation in beef and dairy cattle. In dairy cattle, detection of estrus can be difficult due to a number of factors including the incidence of silent estrus. Hormonal treatments designed to control both luteal and follicular function has permitting efficient synchronizations of time of ovulation. Thus, the AI can be performed in a large number of animals on a fixed schedule without the need for detection of estrus. Using these management techniques, the fixed-time artificial insemination (TAI) can overcome the problem of accurate estrus detection and help in reducing the incidence of repeat breeding. In addition, with TAI in cattle operations, it is possible to facilitate management practices and commercialization, and to reduce the time and semen wasting with animals inseminated at incorrect times. The investigation of practical and efficient TAI protocols is important for reducing the labor and animal handling of TAI in dairy cattle, as well as for increasing the profitability of the cattle management system. This study was carried out in order to investigate the effectiveness of TAI in dairy heifers treated with a practical progesterone-based protocol.Materials, Methods & Results: This experiment was conducted at the university farm located in southwestern Brazil, during May 2009. Thirty-nine cycling crossbred dairy heifers were employed in this study. All animals received a single intramuscular injection of estradiol benzoate and intravaginal progesterone releasing device in a random stage of the estrous cycle (Day 0). on day 7 the animals were treated with PGF2a analogue and on day 9 the device was removed. Forty-eight hours after the device removal (day 11) a synthetic analogue of GnRH was administered and the animals were fixed-time artificially inseminated at the time of GnRH injection. The inseminations were performed using four different batches from the same Holstein bull. Among the heifers that were synchronized (87.2%), 30.8% ovulated until 24 h after TAI and 56.4% ovulated between 24 and 32 h after TAI. The conception rate was 61.5%. No effects of ovulation time in conception rates were detected. The conception rate from heifers that ovulated until 24 h after TAI was 58.3% and from heifers that ovulated between 24 and 32 h after TAI was 77.3%. The mean of ovulatory follicle in heifers that ovulated until 24 h was 14.3 mm and in heifers that ovulated between 24 and 32 h was 11.9 mm.Discussion: Taking together, the findings of the present study, along with those of others, emphasize the concept that development of practical methods for TAI offers significant advantages to dairy producers if conception rates are close or greater to those obtained after breeding at detected estrus. Thus, the results of the present study reinforce the possibility of making dairy cattle production more cost-effective using TAI. In conclusion, with the progesterone-based TAI protocol of the present experiment all synchronized animals ovulated up to 32 h after GnRH+TAI and no effects of ovulation time related to conception rate was detected. The exogenous control of luteal and follicular development facilitated the reproductive management and animal handling. Also, inseminating the heifers at the moment of GnRH injection in a progesterone-based TAI protocol is a practical strategy and provided satisfactory results regarding ovulation and conception rates in dairy heifers.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Self-organizing maps (SOM) are artificial neural networks widely used in the data mining field, mainly because they constitute a dimensionality reduction technique given the fixed grid of neurons associated with the network. In order to properly the partition and visualize the SOM network, the various methods available in the literature must be applied in a post-processing stage, that consists of inferring, through its neurons, relevant characteristics of the data set. In general, such processing applied to the network neurons, instead of the entire database, reduces the computational costs due to vector quantization. This work proposes a post-processing of the SOM neurons in the input and output spaces, combining visualization techniques with algorithms based on gravitational forces and the search for the shortest path with the greatest reward. Such methods take into account the connection strength between neighbouring neurons and characteristics of pattern density and distances among neurons, both associated with the position that the neurons occupy in the data space after training the network. Thus, the goal consists of defining more clearly the arrangement of the clusters present in the data. Experiments were carried out so as to evaluate the proposed methods using various artificially generated data sets, as well as real world data sets. The results obtained were compared with those from a number of well-known methods existent in the literature

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The present essay shows strategies of improvement in a well succeded evolutionary metaheuristic to solve the Asymmetric Traveling Salesman Problem. Such steps consist in a Memetic Algorithm projected mainly to this problem. Basically this improvement applied optimizing techniques known as Path-Relinking and Vocabulary Building. Furthermore, this last one has being used in two different ways, in order to evaluate the effects of the improvement on the evolutionary metaheuristic. These methods were implemented in C++ code and the experiments were done under instances at TSPLIB library, being possible to observe that the procedures purposed reached success on the tests done

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The conventional Newton and fast decoupled power flow (FDPF) methods have been considered inadequate to obtain the maximum loading point of power systems due to ill-conditioning problems at and near this critical point. It is well known that the PV and Q-theta decoupling assumptions of the fast decoupled power flow formulation no longer hold in the vicinity of the critical point. Moreover, the Jacobian matrix of the Newton method becomes singular at this point. However, the maximum loading point can be efficiently computed through parameterization techniques of continuation methods. In this paper it is shown that by using either theta or V as a parameter, the new fast decoupled power flow versions (XB and BX) become adequate for the computation of the maximum loading point only with a few small modifications. The possible use of reactive power injection in a selected PV bus (Q(PV)) as continuation parameter (mu) for the computation of the maximum loading point is also shown. A trivial secant predictor, the modified zero-order polynomial which uses the current solution and a fixed increment in the parameter (V, theta, or mu) as an estimate for the next solution, is used in predictor step. These new versions are compared to each other with the purpose of pointing out their features, as well as the influence of reactive power and transformer tap limits. The results obtained with the new approach for the IEEE test systems (14, 30, 57 and 118 buses) are presented and discussed in the companion paper. The results show that the characteristics of the conventional method are enhanced and the region of convergence around the singular solution is enlarged. In addition, it is shown that parameters can be switched during the tracing process in order to efficiently determine all the PV curve points with few iterations. (C) 2003 Elsevier B.V. All rights reserved.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The parameterized fast decoupled power flow (PFDPF), versions XB and BX, using either theta or V as a parameter have been proposed by the authors in Part I of this paper. The use of reactive power injection of a selected PVbus (Q(PV)) as the continuation parameter for the computation of the maximum loading point (MLP) was also investigated. In this paper, the proposed versions obtained only with small modifications of the conventional one are used for the computation of the MLP of IEEE test systems (14, 30, 57 and 118 buses). These new versions are compared to each other with the purpose of pointing out their features, as well as the influence of reactive power and transformer tap limits. The results obtained with the new approaches are presented and discussed. The results show that the characteristics of the conventional FDPF method are enhanced and the region of convergence around the singular solution is enlarged. In addition, it is shown that these versions can be switched during the tracing process in order to efficiently determine all the PV curve points with few iterations. A trivial secant predictor, the modified zero-order polynomial, which uses the current solution and a fixed increment in the parameter (V, theta, or mu) as an estimate for the next solution, is used for the predictor step. (C) 2003 Elsevier B.V. All rights reserved.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The aim of this study was to evaluate the application of PCR technique for the detection of BoHV-5 in routinely formalin-fixed, paraffin-embedded brain tissues in 20 naturally infected calves affected by fatal meningoencephalitis. Brains were divided into two halves, one kept fresh for virus isolation and PCR assay, targeting the glycoprotein C gene from BoHV-5 genome. The other half brain, corresponding to posterior cortex region, was submitted to formalin fixation and embedded into paraffin blocks for microscopic evaluation and total DNA isolation. Most of the slides showed severe multifocal non-supurative encephalitis with neuronal degeneration, neurophagia, and no acidophilic intranuclear inclusions could be found in neurons and glial. The 20 fresh samples were confirmed, by virus isolation and PCR assay, as having the BoHV-5 virus and, respective glicoprotein C sequence, while 15 of 20 formalin-fixed, paraffin-embedded samples were considered positive for the same analysis. The results revealed the first description of PCR efficiency, applied to formalin-fixed, paraffin-embedded brain collected from naturally infected calves, improving the detection of BoHV-5 from archival samples in South America. (c) 2007 Published by Elsevier B.V.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Purpose: Three-dimensional finite element analysis was used to evaluate the effect of vertical and angular misfit in three-piece implant-supported screw-retained fixed prostheses on the biomechanical response in the peri-implant bone, implants, and prosthetic components. Materials and Methods: Four three-dimensional models were fabricated to represent a right posterior mandibular section with one implant in the region of the second premolar (2PM) and another in the region of the second molar (2M). The implants were splinted by a three-piece implant-supported metal-ceramic prosthesis and differed according to the type of misfit, as represented by four different models: Control = prosthesis with complete fit to the implants; UAM (unilateral angular misfit) = prosthesis presenting unilateral angular misfit of 100 pm in the mesial region of the 2M; UVM (unilateral vertical misfit) = prosthesis presenting unilateral vertical misfit of 100 pm in the mesial region of the 2M; and TVM (total vertical misfit) = prosthesis presenting total vertical misfit of 100 pm in the platform of the framework in the 2M. A vertical load of 400 N was distributed and applied on 12 centric points by the software Ansys, ie, a vertical load of 150 N was applied to each molar in the prosthesis and a vertical load of 100 N was applied at the 2PM. Results: The stress values and distribution in peri-implant bone tissue were similar for all groups. The models with misfit exhibited different distribution patterns and increased stress magnitude in comparison to the control. The highest stress values in group UAM were observed in the implant body and retention screw. The groups UVM and TVM exhibited high stress values in the platform of the framework and the implant hexagon, respectively. Conclusions: The three types of misfit influenced the magnitude and distribution of stresses. The influence of misfit on peri-implant bone tissue was modest. Each type of misfit increased the stress values in different regions of the system. INT J ORAL MAXILLOFAC IMPLANTS 2011;26:788-796

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Objective: The purpose of this study was to perform histological and histometric analyses of the repair process of autogenous bone grafts fixed at rat calvaria with ethyl-cyanoacrylate adhesive. Material and Methods: Thirty-two rats were divided into two groups (n=16), Group I - Control and Group II - Adhesive. Osteotomies were made at the right parietal bone for graft obtainment using a 4-mm-diameter trephine drill. Then, the bone segments were fixed with the adhesive in the parietal region of the opposite side to the donor site. After 10 and 30 days, 8 animals of each group were euthanized and the calvarias were laboratorially processed for obtaining hematoxylin and eosin-stained slides for histological and histometric analyses. Results: An intense inflammatory reaction was observed at the 10-day period. At 30 days, this reaction was less intense, despite the presence of adhesive at the recipient-site/graft interface. Graft incorporation to the recipient site was observed only at the control group, which maintained the highest graft size at 10 and 30 days. Conclusions: Although the fragment was stable, the presence of adhesive in Group II did not allow graft incorporation to the recipient site, determining a localized, discrete and persistent inflammatory reaction.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The use of glycol methacrylate (GMA) avoids some technical artifacts, which are usually observed in paraffin-embedded sections, providing good morphological resolution. on the other hand, weak staining have been mentioned during the use of different methods in plastic sections. In the present study, changes in the histological staining procedures have been assayed during the use of staining and histochemical methods in different GMA-embedded tissues.Samples of tongue, submandibular and sublingual glands, cartilage, portions of respiratory tract and nervous ganglion were fixed in 4% formaldehyde and embedded in glycol methacrylate. The sections of tongue and nervous ganglion were stained by H&E. Picrosirius, Toluidine Blue and Sudan Black B methods were applied, respectively, for identification of collagen fibers in submandibular gland, sulfated glycosaminoglycans in cartilage (metachromasia) and myelin lipids in nervous ganglion. Periodic Acid-Schiff (PAS) method was used for detection of glycoconjugates in submandibular gland and cartilage while AB/PAS combined methods were applied for detection of mucins in the respiratory tract. In addition, a combination of Alcian Blue (AB) and Picrosirius methods was also assayed in the sublingual gland sections.The GMA-embedded tissue sections showed an optimal morphological integrity and were favorable to the staining methods employed in the present study. In the sections of tongue and nervous ganglion, a good contrast of basophilic and acidophilic structures was obtained by H&E. An intense eosinophilia was observed either in the striated muscle fibers or in the myelin sheaths in which the lipids were preserved and revealed by Sudan Black B. In the cartilage matrix, a strong metachromasia was revealed by Toluidine Blue in the negatively-charged glycosaminoglycans. In the chondrocytes, glycogen granules were intensely positive to PAS method. Extracellular glycoproteins were also PAS positive in the basal membrane and in the region occupied by the lamina externa and reticular fibers surrounding each smooth muscle cells of the blood vessels. In the epithelial cells of the respiratory tract, acid and neutral mucins were histochemically detected by AB and PAS methods, respectively. Moreover, granules containing acid and neutral mucins were revealed in purple by AB and PAS concomitantly. In the sublingual gland sections, a distinct affinity of acid mucins by AB (in turquoise-blue) and collagen fibers by Picrosirius (in red) was obtained when these methods were combined. Although some routine dyes used in paraffin sections have showed a weak stain in historesin sections, our results showed that different dyes could be applied in GMA sections if modified staining procedures were assayed. Therefore, appropriate staining contrast and, thus, detection of one or different substances in a same section can be acquired in association to the good morphological resolution provided by GMA. (C) 2003 Elsevier Ltd. All rights reserved.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Objectives: To verify the consequences of implant-supported fixed oral rehabilitation on the quality of life (QL) of elderly individuals.Material and methods: Fifteen patients were studied, being 10 females and five males; all were aged > 60 years, were completely edentulous, wore removable dentures on both arches, and were treated with implant-supported fixed dentures. Three QL questionnaires were applied, two related to the oral conditions (Oral Impact on Daily Performance - OIDP - and Oral Health Impact Profile, short version - OHIP-14) and one dealing with global aspects (World Health Organization Quality of Life - WHOQOL-BREF), before 3, 6, and 18 months after surgical placement of implants.Results: Scores in the OIDP and OHIP-14 questionnaires were better after dental treatment. The WHOQOL-BREF was less sensitive, confirming the higher reliability of specific questionnaires (focal) compared with general questions in such situations.Conclusion: Treatment with implant-supported fixed prostheses improved QL in the elderly; these effects are better detected by specific instruments focused on the subject.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Objectives: The present study used strain gauge analysis to perform an in vitro evaluation of the effect of axial loading on 3 elements of implant-supported partial fixed prostheses, varying the type of prosthetic cylinder and the loading points. Material and methods: Three internal hexagon implants were linearly embedded in a polyurethane block. Microunit abutments were connected to the implants applying a torque of 20 Ncm, and prefabricated Co-Cr cylinders and plastic prosthetic cylinders were screwed onto the abutments, which received standard patterns cast in Co-Cr alloy (n=5). Four strain gauges (SG) were bonded onto the surface of the block tangentially to the implants, SG 01 mesially to implant 1, SG 02 and SG 03 mesially and distally to implant 2, respectively, and SG 04 distally to implant 3. Each metallic structure was screwed onto the abutments with a 10 Ncm torque and an axial load of 30 kg was applied at five predetermined points (A, B, C, D, E). The data obtained from the strain gauge analyses were analyzed statistically by RM ANOVA and Tukey's test, with a level of significance of p<0.05. Results: There was a significant difference for the loading point (p=0.0001), with point B generating the smallest microdeformation (239.49 mu epsilon) and point D the highest (442.77 mu epsilon). No significant difference was found for the cylinder type (p=0.748). Conclusions: It was concluded that the type of cylinder did not affect in the magnitude of microdeformation, but the axial loading location influenced this magnitude.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Purpose: To evaluate the flexural strength of two fixed dental prosthesis (FDP) designs simulating frameworks of adhesive fixed partial prostheses, reinforced or not by glass fiber.Materials and Methods: Forty specimens, made with composite resin, were divided into 4 groups according to the framework design and the presence of fiber reinforcement: A1 - occlusal support; A2: occlusal support + glass fiber; B1: occlusal and proximal supports; B2: occlusal and proximal supports + glass fiber. The specimens were subjected to the three-point bending test, and the data were submitted to two-way ANOVA and Tukey's test (5%).Results: Group A2 (97.9 +/- 38 N) was statistically significantly different from all other experimental groups, presenting a significantly lower mean flexural strength.Conclusion: The use of glass fibers did not improve the flexural strength of composite resin, and designs with occlusal and proximal supports presented better results than designs simulating only occlusal support.