969 resultados para electromechanical coupling coefficient
Resumo:
High transverse momentum jets produced in pp collisions at a centre of mass energy of 7 TeV are used to measure the transverse energy--energy correlation function and its associated azimuthal asymmetry. The data were recorded with the ATLAS detector at the LHC in the year 2011 and correspond to an integrated luminosity of 158 pb−1. The selection criteria demand the average transverse momentum of the two leading jets in an event to be larger than 250 GeV. The data at detector level are well described by Monte Carlo event generators. They are unfolded to the particle level and compared with theoretical calculations at next-to-leading-order accuracy. The agreement between data and theory is good and provides a precision test of perturbative Quantum Chromodynamics at large momentum transfers. From this comparison, the strong coupling constant given at the Z boson mass is determined to be αs(mZ)=0.1173±0.0010 (exp.) +0.0065−0.0026 (theo.).
Resumo:
Tese de Doutoramento em Engenharia de Materiais.
Resumo:
OBJECTIVE: To compare the heart weight and the heart weight/body weight coefficient of adults with and without chronic malnutrition. METHODS: In an initial case series of 210 autopsies performed in adults, we recorded body and heart weights and calculated the heart weight/body weight coefficients (HW/BW x 100). The exclusion criteria were as follows: positive serology for Chagas' disease, edema, obesity, heart diseases, hepatopathies, nephropathies, and systemic arterial hypertension. Malnutrition was characterized as a body mass index <18.5kg/m². Differences with p<0.05 were considered significant. RESULTS: Individuals in the malnourished (n=15) and control (n=21) groups were statistically different, respectively, in regard to body mass index (15.9±1.7 versus 21.3±2.5kg/m²), heart weight (267.3±59.8 versus 329.1±50.4g), and the HW/BW coefficient (0.64±0.12 versus 0.57±0.09%). A positive and significant correlation was observed between heart weight and body mass index (r=0.52), and between heart weight and body weight (r=0.65). CONCLUSION: Malnourished individuals have lighter hearts and a greater HW/BW coefficient than non-malnourished individuals do. These findings indicate a possible preservation of the myocardium in relation to the intensity of weight loss associated with the probable relative increase in cardiac connective tissue and heart blood vessels.
Resumo:
Magdeburg, Univ., Fak. für Naturwiss., Diss., 2014
Resumo:
Magdeburg, Univ., Fak. für Mathematik, Diss., 2015
Resumo:
We consider multidimensional backward stochastic differential equations (BSDEs). We prove the existence and uniqueness of solutions when the coefficient grow super-linearly, and moreover, can be neither locally Lipschitz in the variable y nor in the variable z. This is done with super-linear growth coefficient and a p-integrable terminal condition (p & 1). As application, we establish the existence and uniqueness of solutions to degenerate semilinear PDEs with superlinear growth generator and an Lp-terminal data, p & 1. Our result cover, for instance, the case of PDEs with logarithmic nonlinearities.
Resumo:
L’objectiu d’aquest projecte es basa en l’obtenció de filtres passa banda mitjançant acobladors ressonants en l’ordre dels GHz, amb un ampla de banda fraccional del 30%. En un primer disseny es presentarà l’estudi del coeficient d’acoblament entre partícules ressonants i tot seguit s’introduirà una capacitat interdigital per a augmentar l’acoblament. Mitjançant el nou disseny es demostrarà que es pot arribar a resultats òptims tant en simulacions com a l’hora de fabricar el dispositiu.
Resumo:
The main purpose of this work is to give a survey of main monotonicity properties of queueing processes based on the coupling method. The literature on this topic is quite extensive, and we do not consider all aspects of this topic. Our more concrete goal is to select the most interesting basic monotonicity results and give simple and elegant proofs. Also we give a few new (or revised) proofs of a few important monotonicity properties for the queue-size and workload processes both in single-server and multi- server systems. The paper is organized as follows. In Section 1, the basic notions and results on coupling method are given. Section 2 contains known coupling results for renewal processes with focus on construction of synchronized renewal instants for a superposition of independent renewal processes. In Section 3, we present basic monotonicity results for the queue-size and workload processes. We consider both discrete-and continuous-time queueing systems with single and multi servers. Less known results on monotonicity of queueing processes with dependent service times and interarrival times are also presented. Section 4 is devoted to monotonicity of general Jackson-type queueing networks with Markovian routing. This section is based on the notable paper [17]. Finally, Section 5 contains elements of stability analysis of regenerative queues and networks, where coupling and monotonicity results play a crucial role to establish minimal suficient stability conditions. Besides, we present some new monotonicity results for tandem networks.
Resumo:
Projecte de recerca elaborat a partir d’una estada a la University of Nottingham, Gran Bretanya, entre març i abril del 2007. Aquest treball s’ha centrat en l’aplicació de compostos derivats de la D-(+)-glucosa, de la D-(+)-fructosa i la D-galactosa com a lligands de catalitzadors homogenis quirals en dos reaccions asimètriques: addició 1,2 a aldehids catalitzada per níquel i addició 1,4 conjugada catalitzada per coure.(veure figura adjunta al final del document). En primer lloc, s’ha estudiat l’aplicació dels compostos L1-L6 a les reaccions d’addició 1,2 a aldehids catalitzades per níquel. S’ha observat que la selectivitat del procés depèn principalment del grup funcional unit a l’esquelet del lligand, de les propietats estèriques del substituent en la funció oxazolina i de l’estructura del substrat. S’ha obtingut fins a un 59% d’excés enantiomèric utilitzant el precursor de catalitzador que conté el lligand L3a. En segon lloc, aquest treball descriu l’aplicació de les tres famílies de compostos (L1-L11) com a lligands en la reacció d’addició 1,4 catalitzada per coure de compostos organometàl•lics a diferents enones amb diferents propietats estèriques. L’ús de les llibreries de compostos fosfit-oxazolina (L1-L5) i fosfit-fosforamidit (L6) han proporcionat bones enantioselectivitats (fins a 80%) en l’addició de reactius de trialquilalumini a diferents enones. En canvi, la llibreria de compostos monofosfit (L7-L11) ha mostrat bones activitats però enantioselectivitats fins a 57%.
How do technical change and technological distance influence the size of the Okun’s Law coefficient?
Resumo:
How does technical change influence the size of the Okun’s Law coefficient? Using a nonlinear version of Okun’s Law augmented with technical change and technological distance, we show that the impact of output movements on unemployment variations is influenced by the imitation or innovation origins of technical change
Resumo:
L-Type Ca(2+) and K(ATP) Channels in Pacing-Induced Cardioprotection. AIMS: The L-type Ca(2+) channel, the sarcolemmal (sarcK(ATP)), and mitochondrial K(ATP) (mitoK(ATP)) channels are involved in myocardial preconditioning. We aimed at determining to what extent these channels can also participate in pacing-induced cardioprotection. METHODS: Hearts of 4-day-old chick embryos were paced in ovo during 12 hour using asynchronous intermittent ventricular stimulation at 110% of the intrinsic rate. Sham operated and paced hearts were then submitted in vitro to anoxia (30 minutes) and reoxygenation (60 minutes). These hearts were exposed to L-type Ca(2+) channel agonist Bay-K-8644 (BAY-K) or blocker verapamil, nonselective K(ATP) channel antagonist glibenclamide (GLIB), mitoK(ATP) channel agonist diazoxide (DIAZO), or antagonist 5-hydroxydecanoate. Electrocardiogram, electromechanical delay (EMD) reflecting excitation-contraction (E-C) coupling, and contractility were determined. RESULTS: Under normoxia, heart rate, QT duration, conduction, EMD, and ventricular shortening were similar in sham and paced hearts. During reoxygenation, arrhythmias ceased earlier and ventricular EMD recovered faster in paced hearts than in sham hearts. In sham hearts, BAY-K (but not verapamil), DIAZO (but not 5-hydroxydecanoate) or GLIB accelerated recovery of ventricular EMD, reproducing the pacing-induced protection. By contrast, none of these agents further ameliorated recovery of the paced hearts. CONCLUSION: The protective effect of chronic asynchronous pacing at near physiological rate on ventricular E-C coupling appears to be associated with subtle activation of L-type Ca(2+) channel, inhibition of sarcK(ATP) channel, and/or opening of mitoK(ATP) channel.
Resumo:
The sedimentation coefficient of a secretory IgA found in bovine colostrum and saliva is compared with that of IgG and IgM from the same colostrum. The IgA fraction gives a value of 10.8 S, whereas the major part of the IgG has a value of 7.1 S and the IgM 19.2 S. The sedimentation coefficient of the free secretory piece has also been determined: its value is 4.95 S.
Resumo:
WHAT'S KNOWN ON THE SUBJECT? AND WHAT DOES THE STUDY ADD?: The AMS 800 urinary control system is the gold standard for the treatment of urinary incontinence due to sphincter insufficiency. Despite excellent functional outcome and latest technological improvements, the revision rate remains significant. To overcome the shortcomings of the current device, we developed a modern electromechanical artificial urinary sphincter. The results demonstrated that this new sphincter is effective and well tolerated up to 3 months. This preliminary study represents a first step in the clinical application of novel technologies and an alternative compression mechanism to the urethra. OBJECTIVES: To evaluate the effectiveness in continence achievement of a new electromechanical artificial urinary sphincter (emAUS) in an animal model. To assess urethral response and animal general response to short-term and mid-term activation of the emAUS. MATERIALS AND METHODS: The principle of the emAUS is electromechanical induction of alternating compression of successive segments of the urethra by a series of cuffs activated by artificial muscles. Between February 2009 and May 2010 the emAUS was implanted in 17 sheep divided into three groups. The first phase aimed to measure bladder leak point pressure during the activation of the device. The second and third phases aimed to assess tissue response to the presence of the device after 2-9 weeks and after 3 months respectively. Histopathological and immunohistochemistry evaluation of the urethra was performed. RESULTS: Bladder leak point pressure was measured at levels between 1091 ± 30.6 cmH2 O and 1244.1 ± 99 cmH2 O (mean ± standard deviation) depending on the number of cuffs used. At gross examination, the explanted urethra showed no sign of infection, atrophy or stricture. On microscopic examination no significant difference in structure was found between urethral structure surrounded by a cuff and control urethra. In the peripheral tissues, the implanted material elicited a chronic foreign body reaction. Apart from one case, specimens did not show significant presence of lymphocytes, polymorphonuclear leucocytes, necrosis or cell degeneration. Immunohistochemistry confirmed the absence of macrophages in the samples. CONCLUSIONS: This animal study shows that the emAUS can provide continence. This new electronic controlled sequential alternating compression mechanism can avoid damage to urethral vascularity, at least up to 3 months after implantation. After this positive proof of concept, long-term studies are needed before clinical application could be considered.
Resumo:
Analyzing the relationship between the baseline value and subsequent change of a continuous variable is a frequent matter of inquiry in cohort studies. These analyses are surprisingly complex, particularly if only two waves of data are available. It is unclear for non-biostatisticians where the complexity of this analysis lies and which statistical method is adequate.With the help of simulated longitudinal data of body mass index in children,we review statistical methods for the analysis of the association between the baseline value and subsequent change, assuming linear growth with time. Key issues in such analyses are mathematical coupling, measurement error, variability of change between individuals, and regression to the mean. Ideally, it is better to rely on multiple repeated measurements at different times and a linear random effects model is a standard approach if more than two waves of data are available. If only two waves of data are available, our simulations show that Blomqvist's method - which consists in adjusting for measurement error variance the estimated regression coefficient of observed change on baseline value - provides accurate estimates. The adequacy of the methods to assess the relationship between the baseline value and subsequent change depends on the number of data waves, the availability of information on measurement error, and the variability of change between individuals.
Resumo:
Objectifs : Le coefficient de diffusion apparente (ADC) est utilisé pour le suivi des lésions hépatiques malignes traitées. Cependant, l'ADC est généralement mesuré dans la lésion entière, alors que cela devrait être réalisé dans la zone la plus restreinte (ZLPR), cette dernière représentant potentiellement du résidu tumoral. Notre objectif était d'évaluer la variabilité inter/intraobservateur de l'ADC dans la tumeur entière et dans la ZLPR. Matériels et méthodes : Quarante patients traités par chimioembolisation ou radiofréquence ont été évalués. Après consensus, deux lecteurs ont indépendamment mesuré l'ADC de la lésion entière et de la ZLPR. Les mêmes mesures ont été répétées deux semaines plus tard. Le test de Spearman et la méthode de Bland-Altman ont été utilisées. Résultats : La corrélation interobservateur de l'ADC dans la lésion entière et dans la ZLPR était de 0,962 et de 0,884. La corrélation intraobservateur était de 0,992 et de 0,979, respectivement. Les limites de variabilité interobservateur (mm2/sec*10 - 3) étaient entre -0,25/+0,28 dans la lésion entière et entre -0,51/+0,46 dans la ZLPR. Les limites de variabilité intraobservateur étaient respectivement : -0,25/+0,24 et -0,43/+0,47. Conclusion : La corrélation inter/intraobservateur dans les mesures d'ADC est bonne. Toutefois, une variabilité limitée existe et doit être considérée lors de l'interprétation des valeurs d'ADC des tumeurs hépatiques.